| Sl. No. | Item Description |
| 1 | Dismantling Roofing (c)Mud roofing with wooden planks laid over battens. |
| 2 | Earthwork in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in15cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres |
| 3 | Cement concrete 1:2:4 mixing by mechanical means using concrete mixer volumetric type (below footing) |
| 4 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth (isolated footing +PB1)) |
| 5 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer asper IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in super structure (for columns+ SB1+ARCH BEAM+ROOF SLAB) |
| 6 | Cold twisted detormed (Ribbed/ Tor steel)Bars (Fe550grade as per IS1786-2008) , for R.C.C works,where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 7 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) isolated footing+ pb1+Column upto SB1 |
| 8 | Centering and shuttering for columns |
| 9 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels ( sb1) |
| 10 | Centering and shuttering for arches of varandah,door and windows openings |
| 11 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc |
| 12 | First class burnt brickwork laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level (for parapet wall+arch filling) |
| 13 | Earth filling b (i) Earthwork (exclusive of compensation for earth) in excavation in ordinary soil or soil containing gravel or kankar upto 40% and filling in 15 cm layers in foundation and plinth including ramming watering and consolidating under floors with earth brought from a distance not exceeding 30 metres |
| 14 | 12.5 mm thick cement plaster 1:4 |
| 15 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Soluble Salt Technology (thickness to be specified by the manufacturer)with water absorption’s less than 0.08% and conforming to IS:15622 of approved make in allcolours and shades, laid on 20 mm thick cement mortar 1:4(1 cement: 4 fine sand), complete. (Soluble salt Print Penetration should be upto 1 to 2 mm after the tiles are fired & polished ).Size 600 x 600 mm |
| 16 | Providing and laying 60mm thick factory made cement concrete interlocking Paving blocks of M 35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRCSP63-2014 andof approved size and design/ shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in Charge |
| 17 | Providing and applying plaster of paris (ISI marked such as JK,Kohinoor,Maharaja etc.) putting 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge |
| 18 | Wall painting with plastic emulsion paint of approved brand and manufacturer to givean even shade (two or more coats) |
| 19 | Cement concrete 1:8:16 ( b ii )With stone aggregates 40mm gauge mixing by mechanical means using concretemixer volumetric type |
| 20 | Deodar wood doors shutter windows shutter including hinges,screw and cords etc. Complete fixed in position Panelled, glazed or glazed and panelled 40 mm thick (Single Leaf) |
| 21 | Dressed or moulded three brick cornice laid in cement sand mortar 1:4 including 12.5 mm thick cement plaster 1:4 or pointing as required |
| 22 | Providing and laying four courses of water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown type bitumen grade 85/25 applied hot at 1.20Kg.Per sqm of area for each courses econd course on roofing felt type 3 grade-1 (Hession base self finished bitumen felt)and fourth and final course of stonegr it 6 mm and down size orpea sizes grit spread at 0.006cum per Sqm including preparation of surface complete. |
| 23 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked), overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge conduit PVC pipe 20mm/25mm dia. ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fanbox (1.6 mm thick shape hexagonal), Circular junction Boxes(Four way PVC 1 ½\\" deep for walls and CI3 \\"deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq.mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface) -: Wiring fan point (With fan box) |
| 24 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked), overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge conduit PVC pipe 20mm/25mm dia. ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fanbox (1.6 mm thick shape hexagonal), Circular junction Boxes(Four way PVC 1 ½\\" deep for walls and CI3 \\"deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq.mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface) -: Wiring light point |
| 25 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked), overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge conduit PVC pipe 20mm/25mm dia. ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fanbox (1.6 mm thick shape hexagonal), Circular junction Boxes(Four way PVC 1 ½\\" deep for walls and CI3 \\"deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq.mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface) -: Wiring 6Amp. wall socket point |
| 26 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked), overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge conduit PVC pipe 20mm/25mm dia. ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fanbox (1.6 mm thick shape hexagonal), Circular junction Boxes(Four way PVC 1 ½\\" deep for walls and CI3 \\"deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq.mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface)-: Wiring 6Amp. Plug control comprising wall socket point |
| 27 | Providing & placing in position on terrace (at all floor levels)HDPE water storage tanks of approved make (to the approval of Engineer in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple layer tanks |
| 28 | Providing&fixinginpositiononterrace(atall floor levels) HDPE tank cover for water storage tanks of approved make (to the approval of Engineer-in-charge) complete in all respect |
| 29 | Providing and fixing in position automatic brass Ball Cock in tanks |
| 30 | Providing and fixing in position G.I. Tank Nippleof approvedmake (to theapproval of Engineer-in-charge) in PVCWater storage tanks complete in all respect G.I. tank nipple 25mm i/d |
| 31 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) withwaste coupling complete in all respect |
| 32 | Providing and fixing PTMT Bottletrap 31mm single piece moulded with height of 270mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25mm minimum water seal, weighing not less than 260 gms of approved make(to the approval of Engineer-in-charge) for wash hand basin and sink complete inall respect. |
| 33 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipesasper IS15778(ISImarked with the prior approval of Engineer-in Charge),havingthermalstabilityforhot& cold water supply, including all CPVC plain&brass threaded fittings i/c fixing thepipewithclamps at 1.00mspacing includingjointingofpipes&fittings,with onestepCPVCsolventcementandtesting of pipes complete as per direction of Engineer-in-Charge. (CPVCSDR11Pipe& fitting16mmo/d) |
| 34 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB‘s/ RCBO‘s/ RCCB‘s: Supply and erection of sheet metal Double Door Distribution Boards IP43 IK09 metal door (dust protected) as per IS8623-1&3, IEC61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral earthbars,cement bars, spill protector, color coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of waysfor mounting miniature circuit breakers/ RCBO‘s/ RCCB‘s in the distribution board (For SP&N distribution board with provision DP MCB‘s/RCCB‘s/RCBO‘s as incomer andSPMCB‘s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB‘s/RCCB‘s/RCBO‘s as incomer and SPMCB‘s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc: SP&N Double Door Distribution Board 8 way each |
| 35 | MINIATURE BREAKERS: CIRCUIT Supply and erection of Miniature Circuit Breaker MCB‘s for circuit protection against overload and short circuit current fault suitable for 240/ 415volts 50cycles AC supply with breaking capacity of 10kA,Curve-Cand low watt losses as per IS/IEC 60898-1, energy limitationclass-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs :- MCB Single pole 6-32amp. (10kA, curve-C) |
| 36 | MINIATURE BREAKERS: CIRCUIT Supply and erection of Miniature Circuit Breaker MCB‘s for circuit protection against overload and short circuit current fault suitable for 240/ 415volts 50cycles AC supply with breaking capacity of 10kA,Curve-Cand low watt losses as per IS/IEC 60898-1, energy limitationclass-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs :- MCB Double pole 50, 63amp. (10kA, curve-C) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued