Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #57271090

Tender For Repair & Renovation Of Gauge Hut At Rd 322585 Of Rajasthan Feeder

Issued by Government Departments · Firozepur, Punjab
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Sep 2026
0 days left
EMD
18063
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Firozepur → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair & Renovation Of Gauge Hut At Rd 322585 Of Rajasthan Feeder

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 14-Sep-2026 Corrigencum3 Date 16-Sep-2026
2 10-Sep-2026 Corrigendum2 Date 14-Sep-2026
3 07-Sep-2026 Corrigendum1 Date 10-Sep-2026

BOQ

Name of Work:- Repair & Renovation of Gauge Hut at RD 322585 of Rajasthan Feeder
Sl. No. Item Description
1Dismantling Roofing (c)Mud roofing with wooden planks laid over battens.
2Earthwork in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in15cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres
3Cement concrete 1:2:4 mixing by mechanical means using concrete mixer volumetric type (below footing)
4Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth (isolated footing +PB1))
5Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer asper IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in super structure (for columns+ SB1+ARCH BEAM+ROOF SLAB)
6Cold twisted detormed (Ribbed/ Tor steel)Bars (Fe550grade as per IS1786-2008) , for R.C.C works,where not including in the complete rate of RCC including binding, bending and placing in position complete
7Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) isolated footing+ pb1+Column upto SB1
8Centering and shuttering for columns
9Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels ( sb1)
10Centering and shuttering for arches of varandah,door and windows openings
11Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc
12First class burnt brickwork laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level (for parapet wall+arch filling)
13Earth filling b (i) Earthwork (exclusive of compensation for earth) in excavation in ordinary soil or soil containing gravel or kankar upto 40% and filling in 15 cm layers in foundation and plinth including ramming watering and consolidating under floors with earth brought from a distance not exceeding 30 metres
1412.5 mm thick cement plaster 1:4
15Providing and laying vitrified floor tiles in different sizes in light colour shades made using Soluble Salt Technology (thickness to be specified by the manufacturer)with water absorption’s less than 0.08% and conforming to IS:15622 of approved make in allcolours and shades, laid on 20 mm thick cement mortar 1:4(1 cement: 4 fine sand), complete. (Soluble salt Print Penetration should be upto 1 to 2 mm after the tiles are fired & polished ).Size 600 x 600 mm
16Providing and laying 60mm thick factory made cement concrete interlocking Paving blocks of M 35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRCSP63-2014 andof approved size and design/ shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in Charge
17Providing and applying plaster of paris (ISI marked such as JK,Kohinoor,Maharaja etc.) putting 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge
18Wall painting with plastic emulsion paint of approved brand and manufacturer to givean even shade (two or more coats)
19Cement concrete 1:8:16 ( b ii )With stone aggregates 40mm gauge mixing by mechanical means using concretemixer volumetric type
20Deodar wood doors shutter windows shutter including hinges,screw and cords etc. Complete fixed in position Panelled, glazed or glazed and panelled 40 mm thick (Single Leaf)
21Dressed or moulded three brick cornice laid in cement sand mortar 1:4 including 12.5 mm thick cement plaster 1:4 or pointing as required
22Providing and laying four courses of water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown type bitumen grade 85/25 applied hot at 1.20Kg.Per sqm of area for each courses econd course on roofing felt type 3 grade-1 (Hession base self finished bitumen felt)and fourth and final course of stonegr it 6 mm and down size orpea sizes grit spread at 0.006cum per Sqm including preparation of surface complete.
23RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked), overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge conduit PVC pipe 20mm/25mm dia. ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fanbox (1.6 mm thick shape hexagonal), Circular junction Boxes(Four way PVC 1 ½\\" deep for walls and CI3 \\"deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq.mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface) -: Wiring fan point (With fan box)
24RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked), overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge conduit PVC pipe 20mm/25mm dia. ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fanbox (1.6 mm thick shape hexagonal), Circular junction Boxes(Four way PVC 1 ½\\" deep for walls and CI3 \\"deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq.mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface) -: Wiring light point
25RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked), overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge conduit PVC pipe 20mm/25mm dia. ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fanbox (1.6 mm thick shape hexagonal), Circular junction Boxes(Four way PVC 1 ½\\" deep for walls and CI3 \\"deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq.mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface) -: Wiring 6Amp. wall socket point
26RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked), overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge conduit PVC pipe 20mm/25mm dia. ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fanbox (1.6 mm thick shape hexagonal), Circular junction Boxes(Four way PVC 1 ½\\" deep for walls and CI3 \\"deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq.mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface)-: Wiring 6Amp. Plug control comprising wall socket point
27Providing & placing in position on terrace (at all floor levels)HDPE water storage tanks of approved make (to the approval of Engineer in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple layer tanks
28Providing&fixinginpositiononterrace(atall floor levels) HDPE tank cover for water storage tanks of approved make (to the approval of Engineer-in-charge) complete in all respect
29Providing and fixing in position automatic brass Ball Cock in tanks
30Providing and fixing in position G.I. Tank Nippleof approvedmake (to theapproval of Engineer-in-charge) in PVCWater storage tanks complete in all respect G.I. tank nipple 25mm i/d
31Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) withwaste coupling complete in all respect
32Providing and fixing PTMT Bottletrap 31mm single piece moulded with height of 270mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25mm minimum water seal, weighing not less than 260 gms of approved make(to the approval of Engineer-in-charge) for wash hand basin and sink complete inall respect.
33CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipesasper IS15778(ISImarked with the prior approval of Engineer-in Charge),havingthermalstabilityforhot& cold water supply, including all CPVC plain&brass threaded fittings i/c fixing thepipewithclamps at 1.00mspacing includingjointingofpipes&fittings,with onestepCPVCsolventcementandtesting of pipes complete as per direction of Engineer-in-Charge. (CPVCSDR11Pipe& fitting16mmo/d)
34SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB‘s/ RCBO‘s/ RCCB‘s: Supply and erection of sheet metal Double Door Distribution Boards IP43 IK09 metal door (dust protected) as per IS8623-1&3, IEC61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral earthbars,cement bars, spill protector, color coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of waysfor mounting miniature circuit breakers/ RCBO‘s/ RCCB‘s in the distribution board (For SP&N distribution board with provision DP MCB‘s/RCCB‘s/RCBO‘s as incomer andSPMCB‘s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB‘s/RCCB‘s/RCBO‘s as incomer and SPMCB‘s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc: SP&N Double Door Distribution Board 8 way each
35MINIATURE BREAKERS: CIRCUIT Supply and erection of Miniature Circuit Breaker MCB‘s for circuit protection against overload and short circuit current fault suitable for 240/ 415volts 50cycles AC supply with breaking capacity of 10kA,Curve-Cand low watt losses as per IS/IEC 60898-1, energy limitationclass-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs :- MCB Single pole 6-32amp. (10kA, curve-C)
36MINIATURE BREAKERS: CIRCUIT Supply and erection of Miniature Circuit Breaker MCB‘s for circuit protection against overload and short circuit current fault suitable for 240/ 415volts 50cycles AC supply with breaking capacity of 10kA,Curve-Cand low watt losses as per IS/IEC 60898-1, energy limitationclass-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs :- MCB Double pole 50, 63amp. (10kA, curve-C) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57271090
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 16-09-2026
Authority
Authority Name Water Resources Department
Work Description Tender for Repair & Renovation Of Gauge Hut At Rd 322585 Of Rajasthan Feeder
Basic Detail
Tender No 08/Rajasthan/FZR/2026-27
Bidding Type Tender
Location
City Firozepur
State Punjab
Key Dates
Publish Date 14 Sep 2026
Submission Date 16 Sep 2026
Open Date 16 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 18063
Exemption Not Available
Document List
BOQ_355246.xls
e2defb57-4930-48d4-b264-a20d3b5ce823.html
SBDGaugeHutAfterRetender.pdf
Tendernotice_1 (13).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 16, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Sep 14, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 10, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Sep 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Today

Tender Documents

Download All (ZIP) ↓
xls

BOQ_355246.xls

html

e2defb57-4930-48d4-b264-a20d3b5ce823.html

pdf

SBDGaugeHutAfterRetender.pdf

pdf

Tendernotice_1 (13).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders