Tender For Construction Of Bolangir Rural Works Division Building In The District Of Bolangir For The Year 2025-26
Tender Value
1.43 Crore
Estimated cost
Bid Submission
18 Sep 2026
4 days left
EMD
1.43 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Balangir → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Bolangir Rural Works Division Building In The District Of Bolangir For The Year 2025-26
BOQ
| Sl. No. | Item Description |
| 1 | Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment) including cost of all materials, labour, T&P etc complete in all respect and as per direction of the Engineer-in-charge. / Ground Floor |
| 2 | Earth work in excavation of foundation trenches in hard soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lifts with sundries & T&P required for the work complete including cost of all labour,labour cess,T&P,sundries etc. as directed by the Engineer in charge. / Ground Floor |
| 3 | Drain |
| 4 | Internal Road |
| 5 | Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge / Ground Floor |
| 6 | Drain |
| 7 | Internal Road |
| 8 | Cement Concrete (1:3:6) using 40mm size hard granite C.B. metal approved quality from approved quarry including cost, carriage, royalty, cost of all labour. etc complete and as directed by E.I.C. / Ground Floor |
| 9 | Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties and taxes of all materials with labour,labour cess and T&P etc. required for the work complete as per the direction of the Engineer-in-charge. / Ground Floor |
| 10 | Providing and lying plain cement concrete of proportion (1:4:8) in foundation and floors using Portland slag cement (PSC) with 40 mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge. |
| 11 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, and royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge / Ground Floor |
| 12 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. / Ground Floor |
| 13 | First Floor |
| 14 | Head Room(G+1) |
| 15 | Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. / Ground Floor |
| 16 | First Floor |
| 17 | R.C.C. M-20 grade with 20mm and down grade C.B. chips of approved quality from approved quarry including hoisting, laying hire charges of concrete mixture, vibrator, watering, curing and cost of all materials and labour, centering shuttering etc complete but excluding cost of reinforcement. / Ground Floor / Footing |
| 18 | Ground Floor /Column |
| 19 | Ground Floor /Plinth Beam |
| 20 | Ground Floor /Lintel |
| 21 | Ground Floor /Roof Beam |
| 22 | Ground Floor /Roof Slab |
| 23 | Ground Floor /Chajja |
| 24 | Ground Floor /StairCase |
| 25 | First Floor / Column |
| 26 | First Floor / Lintel |
| 27 | First Floor / Roof Beam |
| 28 | First Floor / Roof Slab |
| 29 | First Floor / Chajja |
| 30 | First Floor / StairCase |
| 31 | Head Room / Column |
| 32 | Head Room / Beam |
| 33 | Head Room / Roof Slab |
| 34 | Drain |
| 35 | Providing 25 mm thick grading concrete (1:2:2) on roof slab with 6.7mm & down grades size hard granite crusher broken chips using 2% water proofing cement compound (Make -sika/fosroc/Equivalent) on new work. / Ground Floor |
| 36 | First Floor |
| 37 | Head Room |
| 38 | Straightening, cutting, bending bent up or coiled rods, including cranking, hooking, welding or jointing the M.S. rods or tor confirming to I.S. 432 (Plain) and 1785 (Tor) steel and binding, tying the grills, hoisting, lowering and placing in proper position required for R.C.C. works including cost, conveyance and taxes of M.S. rods or tor steel and binding wires of 18 to 20 gauge and cost of all labour etc.complete in all respect. / Ground Floor |
| 39 | First Floor |
| 40 | Head Room |
| 41 | Drain |
| 42 | 12mm thick C.P.(1:6) on brick masonary to the smooth surface including watering, curing, cost, carriage, royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C. / Ground Floor |
| 43 | First Floor |
| 44 | Head Room |
| 45 | 16mm thick C.P. (1:6) over brick masonary to the smooth surface including watering, curing cost, carriage, royalty, and taxes of all materials, cost of all labour, etc complete as per the direction of E.I.C. / Ground Floor |
| 46 | First Floor |
| 47 | Head Room |
| 48 | 6 mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chiping and slury treatment including watering, curing cost, carriage, royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C. / Ground Floor |
| 49 | First Floor |
| 50 | Head Room |
| 51 | Supplying, fitting and fixing Vitrified tile in floors of approved make confirmating to IS:13755 laid on 20 mm thick cement mortar (1:4) and filling joints with white cement of approved quality including cost of all materials, etc. required for the work all complete as per direction of E.I.C. / Ground Floor |
| 52 | First Floor |
| 53 | Fixing Vitrified tiles in dados skirting and risers of steps on 12mm thick CP (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including cost, carriage, cost of all labour etc. complete. / Ground Floor |
| 54 | First Floor |
| 55 | Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40 sqm. (20mm thick) of approved make in floors laid on 20 mm thick cement mortar (1:4) and filling joints with slurry including cost of all materials, labour T&P etc. required for the work all complete incl. rubbing as per direction of the Engineer-in-charge / Ground Floor |
| 56 | First Floor |
| 57 | Supplying, fitting & fixing of Chequered tiles in floors of approved make laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge / Ground Floor |
| 58 | Priming 1 coat with wall primer water bond cement primer including all labour, materials etc. complete. / Ground Floor |
| 59 | First Floor/ External Wall |
| 60 | First Floor/ Internal Wall |
| 61 | Head Room / External Wall |
| 62 | Head Room/ Internal Wall |
| 63 | Wall Painting two coats with approved Plastic Emulsion Paint including all labour, materials etc. complete. / Ground Floor |
| 64 | First Floor |
| 65 | Head Room |
| 66 | Wall painting two coat with any approved weather coat paint including cost of all materials, labour and T&P require for the work etc. complete as directed by the E.I.C. / Ground Floor |
| 67 | First Floor |
| 68 | Head Room |
| 69 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, taxes, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge / Ground Floor |
| 70 | First Floor |
| 71 | Head Room |
| 72 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. / Ground Floor |
| 73 | First Floor |
| 74 | Priming one coat with any approved primmer (To Receive Enamel paint) including cost of primer & labour to give an even shade etc. complete. / Ground Floor |
| 75 | First Floor |
| 76 | Head Room |
| 77 | Painting two coats with approved enamel paints of approved colour, shade including sand papering, polishing the surface, cost, conveyances of all materials and cost of all labour etc, complete as per specification & direction of E.I.C. / Ground Floor |
| 78 | First Floor |
| 79 | Head Room |
| 80 | Supplying, fiting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fitting and fixture etc. complete / Ground Floor |
| 81 | First Floor |
| 82 | Dressed seasoned sal wood work framed and fixed (wrought and put up) in frames of doors, windows & ventilabours / Ground Floor |
| 83 | First Floor |
| 84 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. / Ground Floor |
| 85 | First Floor |
| 86 | Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -charge. in Ground Floor / Ground Floor |
| 87 | First Floor |
| 88 | Providing fitting and fixing of Gypsum false ceilling with Aluminium anodised T Section No. 3215 with 2'-0\\" center to center, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 2'-0\\"x2'-0\\" suspended from ceiling etc complete. / Ground Floor |
| 89 | First Floor |
| 90 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 5000 m as per Technical Specification Clause 301.5 and as per the direction of EIC. |
| 91 | Construction of Granular Sub-base by providing coarsed graded materials,spreading in uniform layer by mortar grader on prepared surface mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the density, complete as per Clause - 401. |
| 92 | Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. |
| 93 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018. |
| 94 | Dismantling brick or stone masonry in lime or cement mortar under 3mtr height / Ground Floor |
| 95 | First Floor |
| 96 | Dismantling and removing R.C.C. columns, beams, slab, staircase, landing and lintels including stacking the useful materials for reuse and removing the debris within 50m lead. Per 1 cum / Ground Floor |
| 97 | First Floor |
| 98 | Dismantaling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead. / Ground Floor |
| 99 | First Floor |
| 100 | Carriage of by mechanical means within 5KM lead |
| 101 | GPH Works: Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes confirming to ASTM-D- 1785/89 (Sch-80) and pipe fittings of the following nominal borewith clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer-in-charge. |
| 102 | 110mm dia PVC P Trap |
| 103 | 110mm dia PVC Nahani Trap |
| 104 | 110mm dia PVC Door Bend |
| 105 | 110mm dia PVC S/J/D |
| 106 | 110mm dia PVC D/J/D |
| 107 | 110mm dia PVC Offset |
| 108 | 110mm dia PVC Plain bend |
| 109 | 110mm diaPVC cowl |
| 110 | 125mm dia C.P. Grating |
| 111 | Supplying all materials labour T&P and cutting holes through brick masonary walls for taking HCI/PVC and fittings including making good the damages etc. all complete as per P.H. specification and direction of E.I.C. (a)375mm thick wall |
| 112 | (b)250mm thick wall |
| 113 | Supplying all materials labour T & P and fixing wash down water closet (Anglo Indian water closet) with integral S or P trap to the floor with wooden plug and chromium plated crews including jointing the trap with soil pipe in cement mortar (1:1) etc. all complete as per specification and direction of E.I.C.E.W.C. with P Trap with sheet cover |
| 114 | Supplying all materials, labour, T&P and fixing vitrous China-Half Stall wall urinal [Magnum Urinal] including connecting the urinal with waste pipeby means of white lead mixed with chopped hemp etc all complete as per specification and direction of the E.I.C. |
| 115 | Supplying all materials,labour,T&P and fixing glazed earth ware squatting plate size (600 x 350x100/ 450x355x100) mm with integral flushing pipe including embedding the plate in 25 mmC.M (1:8) laid over 150 mm C.C (1:4:8) using 40mm h.g metal etc all complete as per specification and direction of the E.I.C. |
| 116 | Supplying all materials,labour, T&P and providing marble slab in urinal partition wall including cutting grooves in wall and making good the damages including watering curing etc as per specification and direction of the E.I.C |
| 117 | Supplying all materials, labour,T&P and fixing wash basing with hole for pillar taps with C.I./M.S. brackets painted white including holes in walls and making good the damages etc. all complete as per P.H. specification and direction of E.I.C.550mmx400mm WHB with 32mm dia cp west,west pipe,brackets and connection pipe.(make-parry ware) |
| 118 | Supplying all materials, labour T & P and fixing mirror of superior glass mounted on 6mm thick A.C. sheet or plywood sheet and fixing to wooden plugs with C.P. screws and washers complete as per P.H. specification and direction of E.I.C.600mmx450mm B.E. Mirror |
| 119 | Supplying all materials,labour T&P and fixing standard size CP towel ring complete with CP Brass brackets fixed to wooden plugs with CP screws as per P.H. specification and direction of E.I.C.C.P. towel Ring |
| 120 | Supplying all materials, labour, T&P and fixing standard sized Soap Dispensor of Hindware/Jaquar/Parryware complete with all as per specification and direction of the Engineer in charge. Soap dispense with Glass Bottle. |
| 121 | Providing fitting fixing Al door with anodized Al door section of 9202 as vertical member, 9201 as top, 9200 as bottom and middle member with frame section as 9221 with tapered clip no 4660 and frame to be completed by means of jointing angle no 1855 including cost of labour T&P hire charges of drilling machine labour charges etc complete with cost of laminated board. and as per direction of the Engineer in charge. |
| 122 | Supplying all materials labour T&P and fixing Ciramic digital tiles in floors, threads,landing on 25mm thick bed of cm(1:1)jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing complete including cost of precast tiles etc. all complete as per specification and directiof E.I.C.In GF |
| 123 | In FF |
| 124 | Supplying all materials labour T & P and fixing porcelain glazed tiles in dados skirting and risers of steps on 12mm thick C.P. (1:3) jointed with neat cement slurry mixed with pigments to match the shade of tiles including rubbing & polishing complete including cost of tiles etc. all complete as per spcificaiton and direction of E.I.C.In GF |
| 125 | In FF |
| 126 | Supplying all materials,labour,T&P and constructing inspection chamber of the following sizes with cc(1:3:6)using 40mm size hg metal on bed,1st class KB Brickwork in cm(1:6)moulding&shaping the channel inside and benching with cc(1:1.5:3)using 12mm size hg chips,12mm thick CP(1:3)with punning to inside,cement flush pointing (1:3)to outside,RCC cover slab in cc(1:1.5:3)using 12mm size hg. chips with RCC man hole cover,e.w in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing, conveyance of all materials to site,payment of royality,taxes etc. all complete as per approved specification and direction of E.I.C. Inside size 760mmx760mmx 460mm |
| 127 | Supplying all materials labour T & P and laying P.V.C. pipe sewer line, Grade-A of the following internal dia in trenches (to level or slope) and jointing with gasket & stiff mixture or C.M. (1:1), C.C.(1:3:6) with 40mm size h.g. metal on bed of the trench and hunching or allround concrete encasing with C.C. (1:4:8) using 40mm size h.g. metal including curing, conveyance to workside, payment of royality, taxes etc. and testing all complete as per approved drawing, specification and direction of E.I.C.160mm dia p.v.c.pipe with hunch top |
| 128 | Supplying all labour T & P and constructing soakway pit of the following sizes with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B. Brickwork in C.M.(1:6) for the remaining height at top, 12mm thick C.P. (1:4) inside and outside over masonary brick work, gravel packing in the rear of well steining R.C.C. cover slab in C.C. (1:1.5:3) using 12mm size h.g. chips fitted handles including e.w. in open well excavation in all kinds of soil and refilling the cavity around the pit & painting the iron works, wattering, curing, conveyance of all meterails to worksite, payment of royality, taxes etc. all complete as per approved drawing, specification and direction of E.I.C.1.20m dia x 2.00m deep soak pit. |
| 129 | Earth work in all kinds of soil in excavation of foundation trenches within 50m initial lead including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth as per direction of E.I.C.Initial lift upto 1.50m |
| 130 | From 1.50m to 3.00m depth |
| 131 | Supplying all materials labour T&P and filling foundation and plinth with river sand well watered and rammed including conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per the direction of E.I.C. |
| 132 | Supplying all materials,labour,T&P and providing cc(1:3:6)with 40mm H.G metal including watering,curing and conveyance of all materials to site payment of royalry,taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 133 | Supplying all materials labour T&P and providing cc(1:1.5:3)using 12mm hg chips including watering,curing,conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 134 | Supplying all materials labour T&P and providing brick work with Flyash brickwork in cm(1:4) F&P having crushing strength not less than 75kg/cm2 with dimensional tolerance +/- 8% including watering, curing conveyance all materials to worksite payment of royality taxes etc. all complete as per specification direction of E.I.C. |
| 135 | Supplying all materials labour T&P and providing rigid and smooth centering & shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C |
| 136 | Supplying all materials labour T&P and providing M.S. reinforcement for RCC works including cutting,bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 137 | Supplying all materials labour T&P and providing RCC(1:1.5:3)using 12mm hg chips for RCC works including hoisting,laying,watering, curing,conveyance of all materials to work site, payment of royality, taxes etc. all complete as per specification and direction of E.I.C |
| 138 | Supplying all materials, labour T&P and providing 12mm thicks C.P. (1:3)with punning on brick / stone work including watering,curing conveyance of all materials to work site, payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 139 | Supplying all materials labour T&P and fixing of RCC baffle wall precast with CC(1:1.5:3)using 12mm b.h.g. chips and fitted to septic tank as per P.H. specification and direction E.I.C. |
| 140 | Supplying all materials,labour,T&P and providing fitting & fixing PVC Tee in wall including fitting the necessary with cc(1:1.5:3)with 12mm size hg chips all complete including watering,curing,conveyance of all materials to worksite, payment of royality,taxes etc. all complete as per specification and direction of E.I.C.(a) 110mmx110mm x110mm PVC Tee |
| 141 | Supplying all materials labour T&P and Providing cement flush pointing (1:3)to brick masonary including watering,curing, conveyance of all materials to work site etc. all complete as per specification and direction of E.I.C. |
| 142 | Supplying all materials labour T& P and providing 500 x 500 x 100mm thick RCC precast M.H cover in C.C (1:1.5:3) using 12mm h.g. chips placing the cover on the MH/S tank & finishing smooth all complete as per specification and direction of E.I.C |
| 143 | Filling in foundation & plinth with excavated materials including watering, and ramming as per direction of E.I.C. |
| 144 | Supplying all materials,labour,T&P and construction of masonry staging with providing 1st class KB brick work in cm(1:6)of 0.46mtr height in staging,12mm CP in cm(1:6),RCC Beam of 0.25mx0.30mx 2.60m in cc(1:1.5:3)using 12mm size HG chips including centering, shuttering, bending and binding of rod etc watering,curring, conveyance of all materials to work site,payment of royalty,taxes etc all complete as per P.H specification and direction of the E.I.C.1000 lits capacity on the roof of 1st floor |
| 145 | Supplying all materials, labour, T&P and Fitting & Fixing of Rotational moulded polythene cylindrical vertical water storage tankconforming to 12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts, including hoisting upto a height of 5mtr above GL and placing the tank in required position including conveyance of all materials to work site, payment of royalty,taxes etc all complete as per P.H specification and direction of the E.I.C.1000ltr. Capacity Water Storage Tank |
| 146 | Supplying all materials,labour,T&P and fitting & fixing 10ltr. capacity low level flushing cystern with a pair of clamps complete with fittings 32mm dia PVC flush bend,15mm dia, pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cystern and closet and connecting inlet pipe with supply main etc. all connecting inlet pipe with supply main etc. all complete as per specification and direction of E.I.C. 10Ltr. Capacity low level cistern |
| 147 | Supplying all materials labour T&P and providing Fitting and fixing of water coolerwith inbuilt water purification Pure Chill 120PSS UV of size 750x570x1350mm height with water storage capacity of 120litres along with 2no. Of faucets 1 for cold water and 1 for normal water including a flow of 1.50ltr/minute etc all complete as per approved Drawing,specification and direction of E.I.C.Aquaguard pure chill 120PSS UV |
| 148 | Supplying all materials,labour,T&P providing and fixing to wall or ceiling and floor PVC pipe conforming to ASTM-D-1785/89(sch-80)and pipe fitting of the following nominal bore with clamps including making good the wall,ceiling and floor testing all complete as per specification and direction of E.I.C. 40mm dia PVC(ASTM) pipe (External) |
| 149 | 32mm dia PVC(ASTM) pipe(External) |
| 150 | 25mm dia PVC(ASTM) pipe(Internal) |
| 151 | 20mm dia PVC(ASTM) pipe(Internal) |
| 152 | Supplying all materials,labour,T&P cutting holes through brick/stone masonry works including making good the damages in cm(1:4) for taking GI/PVC pipe & fitting etc. all complete as per PH specification and direction of E.I.C / Ground Floor |
| 153 | In FF |
| 154 | Supplying all materials, labour, T & P and cutting grooves in pucca floors and walls for taking G.I. / PVC pipes and making good the damages as per direction of E.I.C. / Ground Floor |
| 155 | In FF |
| 156 | Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per PH specification and direction of E.I.C.(Jaquar make) 15mm dia C.P.L.B. Bib cock |
| 157 | 15mm dia C.P. Two way Bibcock |
| 158 | 15mm dia C.P. Pillar cock long neck |
| 159 | 15mm dia C.P. angle stopcock |
| 160 | 15mm dia Health Faucet & 1.0m long Flexible pipe |
| 161 | 40mm dia U-PVC Ball Valve[Metal Ball] |
| 162 | 32mm dia U-PVC Ball Valve[Metal Ball] |
| 163 | 15mm dia C.P. Extension Piece |
| 164 | 15mm dia C.P. Flange |
| 165 | Supplying all materials,labour,T&P and fitting and fixing of ISI mark 1HP single phase vertical water cool submersible pump set with discharge1800/2200lit./Hour & a head-55/70mtr.of reputed make (CRI/KSB/Texmo or Equivelent)Including cost conveyance and taxes etc. all completes as per P.H. Specification and direction of E.I.C. |
| 166 | Supplying all materials,labour,T&P and fitting & fixing of 1.0HP single phase vertical submersible pump set with commissioning and testing etc. all completes as per P.H. Specification and direction of E.I.C. |
| 167 | Supplying all materials,labour,T&P and fitting & fixing of ISI mark DOL. starter of reputed make like B.C.H. or equivalent for 1HP single phase vertical submersible pump set including all cost conveyance & taxes etc. all completes as per P.H. Specification and direction of E.I.C. |
| 168 | Supplying all materials labour T&P and fitting&fixing of 1.5mm2 3core copper flat suitable cable having ISI mark of reputed company like BCH/Finolex or equivalent & connecting the pump starter including cost conveyance & taxes etc. all completes as per P.H. Specification and direction of E.I.C. |
| 169 | Supplying all materials labour T&P and fitting & fixing plastic rope with MS well cover,MS Clamp,stainless steel short piece,Bend & socket, union including all cost conveyance & taxes etc. all completes as per P.H. Specification direction of E.I.C. |
| 170 | Supplying all materials labour T&P and fitting & fixing of HDPE pipes and pipe fittings with making connection to pump set including all cost conveyance & taxes etc. all completes as per P.H. Specification direction of E.I.C.32mm dia H.D.P.E. pipe |
| 171 | 200MMX125MM SIZE BORE WELL:-Labour for drilling and perfectly vertical bore hole of specified dia. For a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs as required suit the site condition as per the direction of E.I.C. including use of own rigs with its accessories,tools & plants and consumable etc. for lowering of 125mm dia. P.V.C. pipes for housing fitted with sockets with or the necessity for soft ,medium,hard and boulderwith out well screen as per formation (G.I/P.V.C.)casing pipes if required to prevent collapse over burden is to be provided by the contractor including lowrering and withdrawing after completion of the tubles as per direction of E.I.C.Drilling of 200mm. dia. Bore o mtr to 45mt |
| 172 | Drilling 150mm dia. Bore 45 mtr to 225mtr& above |
| 173 | Lowering the folloing size G.I./ P.V.C. pipes with without slotted pipes as per the necessary from ground level up to 30mtrs. Depth and fitted and fixed up in perfectly vertical position including cutting, and threading pipe and slotted pipe and supply and fixing all jointing materials tools and plants etc. complete and keeping the top plugging tube wells to prevent entry of foreign materials from above.Lowring of 200 mm dia pipes |
| 174 | Cost of 200 mm dia P.V.C. casing pipe |
| 175 | .Cleaning and developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of E.I.C.Developing the tube well |
| 176 | supplying of all materials,labours,T&P and fitting&fixing of 5KVA Voltage stabiliser having voltage range from 50volt to 290volt sutable to run 1.00HP sumersible pump set including electrial connection form the existing mains &with the controal panels of the pump set etc.all complete as per specification and direction of E.I.C. |
| 177 | Supplying all materials labour,T&P and fitting&fixing of IM-II hand pump with CI cylinder set with 12mm/16mm dia bright steel connecting rod and 32mm dia. GI pipes 8nos each 3.0mtr length including lowering and cost of all materials etc. all complete as per direction of E.I.C. |
| 178 | Supplying all materials labour T&P and construction of tube well platform as per UNICEF drawing and design etc. all complete as per specification and direction of E.I.C. |
| 179 | Supplying all materials labour T&P and construction of platform drain as per UNICEF design etc. all complete as per specification and direction of E.I.C. |
| 180 | Supplying all materials,labour,T&P and constructing soak way pit of the following size with precast RCC rings joined loose gravel backing in the rear of well steining,RCC cover slab in cc(1:1.5:3) using 12mm HG chips,fitted with iron lifting handles including earthwork in openwell excavation in all kind of soil and refilling of cavity around the pit & painting the iron work,watering,curing, conveyance of all materials to worksite,payment of royalty,taxes etc all complete as per approved specification and direction of the E.I.C. (a)1.22m dia x 2.10m deep soak pit |
| 181 | ELECTRICAL WORK:- MAIN DB Supply & fixing of 100A TPN Panel board 1. 100A 4P 30KA MCCB with Spreader,rotary handle, and UV relaease(Make- Legrand/Seimens/L&T/C&S/Havells)-1 No 2.100A Change over(Manual) with auxillary contact,operating handle and output shorting link(Make- Legrand/Seimens/L&T/C&S/Havells)-1 No 3. 100A cupper bus bar- 2set 4.63A 4P MCB(Make- Legrand/Seimens/L&T/C&S/Havells)-6Nos. 5.40A 4P MCB(Make- Legrand/Seimens/L&T/C&S/Havells)-4Nos. 6.SPD(Type1+2,50kA,3P+N)(Make- Legrand/Seimens/L&T/C&S/Havells)-1No 7.6-32 C Series SP MCB(Make- Legrand/Seimens/L&T/C&S/Havells)-4 Nos 8. Digital Volt meter & Ameter three phase-2Nos 9. All accesories & Connection (Rating & Danger borad) |
| 182 | Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire = Finollex / L & T/ Anchor/ Havels/ V-Guard/ Greatwhite / Polycab) Group A (1.1.1) |
| 183 | -do- .... Group B (1.1.2) |
| 184 | -do- .... Group C (1.1.3) |
| 185 | S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required.2 Modular box with base & cover (1.24.2) |
| 186 | 4 Modular box with base & cover (1.24.3) |
| 187 | 6 Modular box with base & cover (1.24.4) |
| 188 | 8 Modular box with base & cover (1.24.5) |
| 189 | 12 Modular box with base & cover (1.24.6) |
| 190 | S/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board (1.25.1+1.25.4) |
| 191 | S/F of 6 Modular GI box in recess with suitable size of Modular base cover in front including providing and fixing 2 nos 3 pin 5/6 amp. Modular Socket out let & 5/6amp. Modular type switch,connection,painting etc. as required.(2X1.25.1+2X1.25.4)+6 MODULE |
| 192 | S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required (1.25.3+1.25.5)+4 MODULE BOX |
| 193 | S/F of computer board (Modular Type) consisting of 3 nos. of 5 amp plug and switch and 6 amp MCB, Indicator complete with wiring on 12 module M.S.box with B.k.cover(1.24.6 + 3 x (1.25.1+ 1.25.4) + 2.6.1)+Indicator |
| 194 | Wiring for circuit I sub main wiring alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS- 694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required ( Make of wire- Finolex/ / Anchor/ Havels/ V-guard / HPL / L&T / Gratewhite / Polycab). -do- 2x1.5sqmm +1x1.5sqmm ( 1.8.1 ) |
| 195 | -do-2x2.5sqmm +1x1.5sqmm ( 1.8.2 ) |
| 196 | -do- 2x4sqmm +1x1.5sqmm ( 1.8.3 ) |
| 197 | -do- 4x4sqmm +2x2.5sqmm ( 1.8.9 ) |
| 198 | S/Fof 'C' series SP MCB of 5A to 32 Amp rating 240Volt \\"B\\" series MCB for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP)(2.6.1) |
| 199 | S/F of 4 way (4+12) TPN MCB DB Single door (2.5.1) |
| 200 | S/F of 6 way (6+18) TPN MCB DB double door (2.5.6) |
| 201 | S/F of 40A FOUR POLE MCB C Type( Make - HAVELLS /Anchor/Greatwhite/L&T) |
| 202 | S/F of 63A FOUR POLE MCB C Type ( Make - HAVELLS /Anchor/Greatwhite/L&T) |
| 203 | S/F of Call bell/ Buzzer ISI marked sutiable for DC/AC single Phase 230 volts complete as required.(1.30) |
| 204 | S/F of batten holder BK angle holder ISI marked including connection etc instead of ceiling rose (Make: Cona / Anchor / Havells / Greatwhite / Preeti / HPL) (1.29-1.28) |
| 205 | Earthing with G.I. earth pipe 3 metre long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arragement and watering pipe etc. with charcoal and salt as required.(3.2) |
| 206 | Supply and laying 6 SWG G.I wire in recess for loop earthing as required ( 3.17) |
| 207 | S/F of 1200mm A.C. Ceiling fan (1Star) with all accessories and connections with out fan regulator (Make:Usha-Striker One/Neo/Crompton- highspeed/Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/ Great White-ALDOUS/Pollycab-Vital HS) |
| 208 | S/F of electric step ceiling fan regulater in existing switch box including connection with 1.5sqmm FR PVC insulated single core multistrand copper conductor earthing the regulator as required.(1.25a) |
| 209 | S/F of Fan hok S'type made of 16mm MS rod as per specificationn |
| 210 | S/F of extra down rod 20mm Dia (1.41)(20CM) |
| 211 | S/F of 20-25 wt. LED St. Light fitting with LED Electronic driver with all accessories & connection( Make- Crompton/Phillips/HPL/Polycab/Havells ) |
| 212 | S/F of 60 wt. LED St. Light fitting with LED Electronic driver with all accessories & connection( Make- Crompton / Phillips/ HPL/ Polycab / Havells ) |
| 213 | S/F of 18-25 watt LED Tube light fitting compoete with all connection. including fixing and all accessories as per direction of Engineer-In-charge (Make: Havels / Phillps / Crompton / Polycab / HPL) |
| 214 | Supply & fixing of 15W LED Ceiling Light (S)(Make- Havells/panasonic Bajaj/philips/Wipro) all accessories. |
| 215 | Supply & fixing of 24W LED Ceiling Light (S)(Make- Havells/panasonic Bajaj/philips/Wipro) all accessories. |
| 216 | Supply of instalation, Testing commissioning of 12 Watt. LED bulb(Make: Havels / Phillps / Crompton / Polycab / HPL) |
| 217 | S/F of 6 pin 15A modular socket on 2 Modular Metal box for A.C (1.25.5) |
| 218 | S/F of 32A C series D.P. MCB for A.C (make: Legrand/Anchor/Havels/HPL) |
| 219 | S/F of 25A Moter Starter switch for A.C (Make: Havells / Anchor/Le-Grand) |
| 220 | SITC of 1.5 Ton 5 star BEE Rating Inverter type split A.C. M/C with all accessories and connections and installation (Make - LG/ O General/Daikin) |
| 221 | S/F of 4KVA Voltage stabilizer(110-300) upto 1.5 Ton AC(Make-Microtech/V-Guard) |
| 222 | S/F of 300 Exhaust fan with all accessoriesand connections (Make Usha-Aero Clean Plus DBB/ Polycab-Fresh on DBB/ Cropmton-Trans Air12\\" reversible/ Havells-Ventil Air DS(HS)/ Anchor-Anmol Delus R/ Orient-Power Flow DBB) |
| 223 | S/F of 2000 VA Inverter with 2 nos. 180 Ah Tubular battery including trally arrangement (Make: Microtake/ Luminous/Exide) |
| 224 | S/F of 900 VA Inverter with 1 no. 180 Ah Tubular battery including trally arrangement (Make: Microtake/ Luminous) |
| 225 | S/F of 400mm Wall fan with all accessories and connections (Make-Usha-Maxx Air Ultra/Polycab-Arey HS/Cropmton-WM Hiflowave/ Havells-Accelero HS/ Anchor-Altrix HS- OWH/ Orient-Wall43/ Great White-WYNO WF ) |
| 226 | wiring to sub main with 1*1.5 mm2 single core multi strand copper wire for inverter wiring (1x1.5mm) |
| 227 | Supply of 3.5core 35sqmm PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade Armoured cable ( MAKE-HAVELLS/polycab/RR Kable/Rhino cable) |
| 228 | Laying of 35sq mm. 3½ Core cable on surface(5.5.2) |
| 229 | Laying of 35sq mm. 3½ Core cable in ground(5.1.2) |
| 230 | Supplying and making end termination with brass compression gland and aluminum lugs for 35sq mm. 3½ Core cable(5.8.21) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender