Road Transport and Highways Government Departments Closing in 2 days TDR #57267471

Tender For Construction Of Jamod (Khel Lon) To Isai Road Tq. Jalgaon Jamod Dist. Buldana Package No Mh-0779

Issued by Government Departments · Buldhana, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
15 Sep 2026
2 days left
EMD
2.28 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Buldhana → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Jamod (Khel Lon) To Isai Road Tq. Jalgaon Jamod Dist. Buldana Package No Mh-0779

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 04-Sep-2026 CSD Technical Bid 15-Sep-2026
2 04-Sep-2026 SE Amravati Other 15-Sep-2026

BOQ

Name of Work:- Construction of Jamod (Khel Lon) to Isai Road Tq. Jalgaon Jamod Dist. Buldana Package No MH-0779
Sl. No. Item Description
1Clearing grass and removal of rubbish up to a distance of 30 m outside the periphery of the area as per Technical Specification Clause 201. (PMGSY-SOR 2025-2026 Item No. 2.1)
2Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3 (PMGSY-SOR 2025-2026 Item No. 3.5 (iii) )
3Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 (PMGSY-SOR 2025-2026 Item No. 3.3)
4Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (PMGSY-SOR 2025-2026 Item No. 3.4)
5Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (PMGSY-SOR 2025-2026 Item No. 3.14)
6Cement Treated Soil Sub-Base/Base Providing, laying and spreading soil on a prepared sub-grade, pulverising, adding the designed quantity of cement to the spread soil, mixing in place with rotavator, grading with the motor grader and compacting with the road roller at OMC to achieve the desired unconfined compressive strength and to form a layer of sub-base/base as per Technical Specification Clause 404. (PMGSY-SOR 2025-2026 Item No. 4.6)
7Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (PMGSY-SOR 2025-2026 Item No.4.1 / A / (ii))
8Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. (PMGSY-SOR 2025-2026 Item No. 4.8 (2) (A))
9Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (PMGSY-SOR 2025-2026 Item No. 4.8 (3) (a))
10Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. (PMGSY-SOR 2025-2026 Item No.5.2(I))
11Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 (PMGSY-SOR 2025-2026 Item No.5.1(I))
12Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. (PMGSY-SOR 2025-2026 I.No. 5.9- Case II (II))
13Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 (PMGSY-SOR 2025-2026 Item No. 5.12- B)
14Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 (PMGSY-SOR 2025-2026 I.No. 10.10 (ii))
15Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 (PMGSY-SOR 2025-2026 I.No. 10.10 (iii))
16Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704 (PMGSY-SOR 2025-2026 Item No. 10.11)
17Providing and fixing of typical retro reflective MMGSY / PMGSY Project informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Three Plates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to two nos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the top level of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness 12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall confirm to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor. (SSR 2023-24 Item No. 10.23)
18Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor. (SSR 2023-24 Item No.10.24)
19MMGSY / PMGSY Maintenance Information Board- Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class- B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor. (SSR 2023-24 Item No.10.23)
20Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and TechnicalSpecification Clause 1701 (PMGSY-SOR 2025-2026 Item No. 10.3(B))
21Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701 (PMGSY-SOR 2025-2026 Item No. 10.2 (A-2))
22Providing and erecting direction and place identification retro- reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Tehnical Specification Clause 1701. (PMGSY-SOR 2025-2026 Item No. 10.3(A-ii))
23Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2 (PMGSY-SOR 2025-2026 Item No. 10.2(B))
24Providing Vertical Delineator having wide angle cube corner micro prismatic non metallic reflective sheeting confirming to Type XI of ASTM D4956 -09 with White Color and Red Color combination and having minimum of retro reflective exposed area of 125 Sq CM on top slots and 35 Sq CM on bottom slots and no edges shall be exposed for tampering. This tubular delineator shall have a core and shell construction, shell shall be made of tough, high impact resistant, injection-molded, thermoplastic outer body and the inner core shall consist of powder coated or painted Mild steel of minimum thickness 1.0mm.and core-shell structure shall be of height not less than 800 mm above the ground and width not less than 80 mm. The metallic core of the delineator shall extend 300mm beyond the shell length from bottom for installing in the ground. The extended portion shall have slots to insert anchoring rods for enhancing the concrete grip. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The engineering thermoplastic used for making the delineator body shall have minimum initial mechanical properties of 600J/m tested in accordance with ASTM D256 and shall retain at least 70% of these minimum initial values (PWD SSR Item No. 6.14)
25Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. ( PMGSY-SOR 2025-2026 Item No.11.1 (I) (i))
26Sand Filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9 (Item No. 11.2 (I))
27Providing & Placing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 (PMGSY-SOR 2025-2026 Item No. 11.4 (I) (i))
28Providing & Placing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PMGSY-SOR 2025-2026 Item No. 11.4 (I) (i)) P.C.C grade M 15
29Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 R.C.C grade M 30 (PMGSY-SOR 2025-2026 Item No. 11.4 (iii) (i))
30Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 P.C.C grade M 15 (PMGSY-SOR 2025-2026Item No. 12.5 (I) (i))
31Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. II.P.C.C grade M 20 PMGSY-SOR 2025-2026 Item No.12.5 - II-( i )
32Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 IV.R.C.C grade M 25 PMGSY-SOR 2025-2026 Item No.12.5 - IV
33Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 R.C.C. grade M 30 (PMGSY-SOR 2025-2026 Item No. 12.5)
34Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II. RCC Grade M 25 PMGSY-SOR 2025-2026 Item No. 13.1 - II
35Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 (PMGSY-SOR 2025-2026 Item No. 13.5)
36Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 (PMGSY-SOR 2025-2026 Item No.11.8)
37Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 (PMGSY-SOR 2025-2026 Item No.12.7)
38Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 (PMGSY SOR 25-26 Item No. 13.3)
39Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (PMGSY-SOR 2025-2026 Item No.9.3 (B))
40Providing and laying 600 mm dia reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. ( SSR Item No. 9.16)
41Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 (PMGSY-SOR 2025-2026 Item No. 12.9)
42Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete. ( SSR 2023-24 Item No.6.12)
43Removal of Telephone/Electric Poles and Lines Removal of telephone/electric poles with wires including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and upto a lead of 1000 m and stacking the serviceable and unserviceable material separately as per Technical Specification Clause 202. (PMGSY-SOR 2025-2026 Item No. 2.23)
44Laying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105 (ii) (PMGSY-SOR 2025-2026 Item No. 9.2 (ii))
45Providing and fixing stream lined M-20 grade RCC guard stone including mild steel bar reinforcement etc. complete. (PWD-SSR 2022-2023 Item no. 11.27) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57267471
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 15-09-2026
Authority
Authority Name Maharashtra Rural Road Development Association
Work Description Tender for Construction Of Jamod (Khel Lon) To Isai Road Tq. Jalgaon Jamod Dist. Buldana Package No Mh-0779
Basic Detail
Tender No CEMRRDA_SEAMR_BUL_MH0779
Bidding Type Tender
Location
City Buldhana
State Maharashtra
Key Dates
Publish Date 04 Sep 2026
Submission Date 15 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee 11800
EMD 2.28 Lakhs
Exemption Not Available
Document List
BOQ_235158.xls
f28a6b40-6543-41af-95e2-099f433fe56a.html
MH0779SBD.pdf
NIT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Sep 15, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_235158.xls

html

f28a6b40-6543-41af-95e2-099f433fe56a.html

pdf

MH0779SBD.pdf

pdf

NIT.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders