Power Boards / Undertakings / PSU Closing in 8 days TDR #57263157

Tender For De-Stringing Of Existing Panther Conductor And Stringing And Supply Of Htls Conductor Along With All Accessories Of (I) 132Kv Sonabil-Depota Transmission Line, (Ii) 132Kv Sonabil-Ghoramari Transmission Line (Iii)132Kv Ghoramari- Depotatran

Issued by Boards / Undertakings / PSU · Sonitpur, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Sep 2026
8 days left
EMD
64.35 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for De-Stringing Of Existing Panther Conductor And Stringing And Supply Of Htls Conductor Along With All Accessories Of (I) 132Kv Sonabil-Depota Transmission Line, (Ii) 132Kv Sonabil-Ghoramari Transmission Line (Iii)132Kv Ghoramari- Depotatransmission Line

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 11-Sep-2026 CORRIGENDUM-I Technical Bid 23-Sep-2026

BOQ

Name of Work:- De-stringing of existing Panther Conductor and Stringing and Supply of HTLS Conductor along with all accessories of (I) 132KV Sonabil-Depota Transmission line, (II) 132KV Sonabil-Ghoramari Transmission line (III)132KV Ghoramari- DepotaTransmission line
Sl. No. Item Description
1Supply of HTLS Conductor as per specification requirements.
2Single Suspension Hard ware fittings (Quantity included mandatory spares: 3 Nos)
3Single Tension Hard ware fittings(Quantity included mandatory spares: 4 Nos)
4Mid Span Joints(Quantity included mandatory spares: 1 No)
5Repair Sleeves(Quantity included mandatory spares: 1 No)
6Vibration Dampers(Quantity included mandatory spares: 6 Nos)
7Double Tension hardware fittings(Quantity included mandatory spares: 1 No)
890KN Disc insulator (Minimum Creepage Distance shall be 320 mm)
970KN Disc insulator (Minimum Creepage Distance shall be 320 mm)
10Double Suspension Hard ware fittings(Quantity included mandatory spares: 1 No)
11Dead end assembly(Quantity included mandatory spares: 4 Nos)
12Jumper Socket(Quantity included mandatory spares: 4 Nos)
13Supply of HTLS Conductor as per specification requirements.
14Single Suspension Hard ware fittings (Quantity included mandatory spares: 3 Nos)
15Single Tension Hard ware fittings(Quantity included mandatory spares: 4 Nos)
16Mid Span Joints(Quantity included mandatory spares: 1 No)
17Repair Sleeves(Quantity included mandatory spares: 1 No)
18Vibration Dampers(Quantity included mandatory spares: 6 Nos)
19Double Tension hardware fittings(Quantity included mandatory spares: 1 No)
2090KN Disc insulator (Minimum Creepage Distance shall be 320 mm)
2170KN Disc insulator (Minimum Creepage Distance shall be 320 mm)
22Double Suspension Hard ware fittings(Quantity included mandatory spares: 1 No)
23Dead end assembly(Quantity included mandatory spares: 4 Nos)
24Jumper Socket(Quantity included mandatory spares: 4 Nos)
25Preliminary survey including measurement of vertical clearance at maximum sag point, identification and replacement or repairirng of damaged stubs, tower members and earthing and collection of all required documents required for obtaining statutory permission from railways, highway Authorities and other Government bodies as per requirement.
26De-stringing of ACSR panther conductor of existing 132kV Sonabil-Depota line, re-rolling on empty drum, removing of hardware fittings, insulators and accessories, loading and unloading, transportation it to AEGCL store. Length Per Ckt = 17.73KMTotal Ckt Km or total de-stringing required is = 17.73 Km X 3 Ph = 53.19 Km
27Paving, stringing,tensioning, Clamping, jointing etc of HTLS conductor with non metallic core using tension pullar machine as per specification requirements in all the phases including hoisting of insulators, fittings of all necessary hardware & accessories i.e fittings, armour rods, vibration damper, supervision of installation and stringing etc. Length Per Ckt = 17.73KMTotal Ckt Km or total stringing required is = 17.73 Km X 3 Ph = 53.19 Km
28Dismantling of existing clamps, connectors and accessories from gantry to the Bus bar at the terminal Bay of respective Sub-Station (both ends) and reconnection with HTLS compatible connectors, conductor and clamps both supply and erection complete.
29Supply of HTLS Conductor as per specification requirements.
30Single Suspension Hard ware fittings (Quantity included mandatory spares: 2 Nos)
31Single Tension Hard ware fittings(Quantity included mandatory spares: 4 Nos)
32Mid Span Joints(Quantity included mandatory spares: 1 No)
33Repair Sleeves(Quantity included mandatory spares: 1 No)
34Vibration Dampers(Quantity included mandatory spares: 4 Nos)
35Double Tension hardware fittings(Quantity included mandatory spares: 1 No)
3690KN Disc insulator (Minimum Creepage Distance shall be 320 mm)
3770KN Disc insulator (Minimum Creepage Distance shall be 320 mm)
38Double Suspension Hard ware fittings(Quantity included mandatory spares: 1 No)
39Dead end assembly(Quantity included mandatory spares: 4 Nos)
40Jumper Socket(Quantity included mandatory spares: 4 Nos)
41Supply of HTLS Conductor as per specification requirements.
42Single Suspension Hard ware fittings (Quantity included mandatory spares: 2 Nos)
43Single Tension Hard ware fittings(Quantity included mandatory spares: 4 Nos)
44Mid Span Joints(Quantity included mandatory spares: 1 No)
45Repair Sleeves(Quantity included mandatory spares: 1 No)
46Vibration Dampers(Quantity included mandatory spares: 4 Nos)
47Double Tension hardware fittings(Quantity included mandatory spares: 1 No)
4890KN Disc insulator (Minimum Creepage Distance shall be 320 mm)
4970KN Disc insulator (Minimum Creepage Distance shall be 320 mm)
50Double Suspension Hard ware fittings(Quantity included mandatory spares: 1 No)
51Dead end assembly(Quantity included mandatory spares: 4 Nos)
52Jumper Socket(Quantity included mandatory spares: 4 Nos)
53Preliminary survey including measurement of vertical clearance at maximum sag point, identification and replacement or repairirng of damaged stubs, tower members and earthing and collection of all required documents required for obtaining statutory permission from railways, highway Authorities and other Government bodies as per requirement.
54De-stringing of ACSR panther conductor of existing 132kV Sonabil-Ghoramari line, re-rolling on empty drum, removing of hardware fittings, insulators and accessories, loading and unloading, transportation it to AEGCL store. Length Per Ckt= 8.96 KMTotal Ckt Km or total de-stringing required is = 8.96 Km X 3 Ph = 26.88 Km
55Paving, stringing,tensioning, Clamping, jointing etc of HTLS conductor with non metallic core using tension pullar machine as per specification requirements in all the phases including hoisting of insulators, fittings of all necessary hardware & accessories i.e fittings, armour rods, vibration damper, supervision of installation and stringing etc. Length Per Ckt= 8.96 KMTotal Ckt Km or total stringing required is = 8.96 Km X 3 Ph = 21.69 Km
56Dismantling of existing clamps, connectors and accessories from gantry to the Bus bar at the terminal Bay of respective Sub-Station (both ends) and reconnection with HTLS compatible connectors, conductor and clamps both supply and erection complete.
57Supply of HTLS Conductor as per specification requirements.
58Single Suspension Hard ware fittings (Quantity included mandatory spares: 3 Nos)
59Single Tension Hard ware fittings(Quantity included mandatory spares: 4 Nos)
60Mid Span Joints(Quantity included mandatory spares: 1 No)
61Repair Sleeves(Quantity included mandatory spares: 1 No)
62Vibration Dampers(Quantity included mandatory spares: 5 Nos)
63Double Tension hardware fittings(Quantity included mandatory spares: 1 No)
6490KN Disc insulator (Minimum Creepage Distance shall be 320 mm)
6570KN Disc insulator (Minimum Creepage Distance shall be 320 mm)
66Double Suspension Hard ware fittings(Quantity included mandatory spares: 1 No)
67Dead end assembly(Quantity included mandatory spares: 4 Nos)
68Jumper Socket(Quantity included mandatory spares: 4 Nos)
69Supply of HTLS Conductor as per specification requirements.
70Single Suspension Hard ware fittings (Quantity included mandatory spares: 3 Nos)
71Single Tension Hard ware fittings(Quantity included mandatory spares: 4 Nos)
72Mid Span Joints(Quantity included mandatory spares: 1 No)
73Repair Sleeves(Quantity included mandatory spares: 1 No)
74Vibration Dampers(Quantity included mandatory spares: 5 Nos)
75Double Tension hardware fittings(Quantity included mandatory spares: 1 No)
7690KN Disc insulator (Minimum Creepage Distance shall be 320 mm)
7770KN Disc insulator (Minimum Creepage Distance shall be 320 mm)
78Double Suspension Hard ware fittings(Quantity included mandatory spares: 1 No)
79Dead end assembly(Quantity included mandatory spares: 4 Nos)
80Jumper Socket(Quantity included mandatory spares: 4 Nos)
81Preliminary survey including measurement of vertical clearance at maximum sag point, identification and replacement or repairirng of damaged stubs, tower members and earthing and collection of all required documents required for obtaining statutory permission from railways, highway Authorities and other Government bodies as per requirement.
82De-stringing of ACSR panther conductor of existing 132kV Depota-Ghoramari line, re-rolling on empty drum,removing of hardware fittings,insulators and accessories, loading and unloading, transportation it to AEGCL store. Length Per Ckt = 14.297KM.Total Ckt Km or total de-stringing required is = 14.297 Km X 3 Ph = 42.891 Km
83Paving, stringing,tensioning, Clamping, jointing etc of HTLS conductor with non metallic core using tension pullar machine as per specification requirements in all the phases including hoisting of insulators, fittings of all necessary hardware & accessories i.e fittings, armour rods, vibration damper, supervision of installation and stringing etc.Length Per Ckt = 14.297KM.Total Ckt Km or total stringing required is = 14.297 Km X 3 Ph = 42.891 Km
84Dismantling of existing clamps, connectors and accessories from gantry to the Bus bar at the terminal Bay of respective Sub-Station (both ends) and reconnection with HTLS compatible connectors, conductor and clamps both supply and erection complete. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57263157
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 23-09-2026
Authority
Authority Name Assam Electricity Grid Corporation Limited
Work Description Tender for De-Stringing Of Existing Panther Conductor And Stringing And Supply Of Htls Conductor Along With All Accessories Of (I) 132Kv Sonabil-Depota Transmission Line, (Ii) 132Kv Sonabil-Ghoramari Transmission Line (Iii)132Kv Ghoramari- Depotatransmission Line
Basic Detail
Tender No AEGCL/MD/CAR/HTLS/2026/BID/1
Bidding Type Tender
Location
City Sonitpur
State Assam
Key Dates
Publish Date 11 Sep 2026
Submission Date 23 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee 2000
EMD 64.35 Lakhs
Exemption Available
Document List
50531198-0494-441c-a51f-bde7ddcc121f.html
AddlDocu.pdf
BIDVol2.pdf
BOQ_84404.xls
HTLSVol1.pdf
Tendernotice_1 (22).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 23, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 8 days
Sep 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

50531198-0494-441c-a51f-bde7ddcc121f.html

pdf

AddlDocu.pdf

pdf

BIDVol2.pdf

xls

BOQ_84404.xls

pdf

HTLSVol1.pdf

pdf

Tendernotice_1 (22).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders