Tender For Special Repair Of Lt Line To Up Gradation Cable For 623 Sata Bty At Mil Stn Bhuj Under Ge (Army) Bhuj
Tender Value
26.50 Lakhs
Estimated cost
Bid Submission
19 Sep 2026
16 days left
EMD
53000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kachchh → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair Of Lt Line To Up Gradation Cable For 623 Sata Bty At Mil Stn Bhuj Under Ge (Army) Bhuj
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil complete as specified and as directed. |
| 2 | Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil complete as specified and as directed. |
| 3 | Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils complete as specified and as directed. |
| 4 | M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed.Note: Punned thickness shall only be measured and paid |
| 5 | Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables complete as specified and as directed. |
| 6 | S & F GI pipe, light grade, of size 80 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection complete as specified and as directed. |
| 7 | S & F GI pipe, light grade, of size 50 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed. |
| 8 | Dismantaling of any type and size ACSR conductor complete all as specified and directed. |
| 9 | Dismantaling of stay assembly including demolation of concrete etc complete all as specified and directed. |
| 10 | Dismantaling of insulator any size and any type complete all as specified and directed. |
| 11 | Dismantaling of cross arm of MS chanel or angle sections any type any size etc complete all as specified and directed. |
| 12 | Disconnecting, taking out, removing old existing unserviceable LT cable , overhead service cable of any size etc complete all as specified and directed. |
| 13 | Supplying ,Laying , jointing and testing XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of size 10X 2C laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed. |
| 14 | - ditto- here in before Item 13 but of size 4C core 16 Sqmm |
| 15 | - ditto- here in before Item 13 but of size 4C core 25 Sqmm |
| 16 | - ditto- here in before Item 13 but of size 3.5C core 35 Sqmm |
| 17 | - ditto- here in before Item 13 but of size 3.5C core 50 Sqmm |
| 18 | - ditto- here in before Item 13 but of size 3.5C core 70 Sqmm |
| 19 | - ditto- here in before Item 13 but of size 3.5 core 95 Sqmm |
| 20 | - ditto- here in before Item 13 but of size 3.5 core 150 Sqmm |
| 21 | Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box CPRI approved factory fabricated out door,double door cubicle/KIOSK type totally enclosed outer cage made out of 3.0 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm with height not less than 0.8 meter, suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, IP 65 , Gasket insulators, fasteners etc with hinged panel doors (covers) on two sides with handles , bottom gland plate and locking arrangement with latch door mechanism in front and back door, consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper busbar or conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and suitable capacity busbar , Air vent , PCC foundation 1:2:4 for foundation etc comprising for the following :-Location: MFP Near Transformer at SATA Unit |
| 22 | (a) Copper Bus Bar 600 A rating for 3 Phase and 300 A for Neutral - 01 Set |
| 23 | (b) MCCB 4 Pole thermal magnetic release 415 volts 400 A 36 KA,Ics=100%Icu -01(incoming), |
| 24 | (c)MCCB 4 pole thermal magnetic release 250 A, 36 KA,Ics=100%Icu -03 Nos |
| 25 | (d) MCCB 4 pole thermal magnetic release 200 A, 36 KA ,Ics=100%Icu -02 |
| 26 | (e) MCCB 4 pole thermal magnetic release 63 A, 16 KA ,Ics=100%Icu ,-02 nos |
| 27 | (g) Voltmeter digital type 0-500 V with inbuilt selector switch-01 No |
| 28 | (h) Ammeter digital type 0-500 A with in built selector switch and CTs-01 No |
| 29 | (i) 3 Line multifunctional meter-01(Nos) |
| 30 | All as per item no 21 here in before but LT Panel consisting of following items (Behind Trg Cell ) complete alla s specified and directed. |
| 31 | (a) Aluminium Bus Bar 400 A rating for 3 Phase and 200 A for Neutral - 01 Set |
| 32 | (b) MCCB 4 Pole thermal magnetic release 415 volts 250 A 36 KA,Ics=100%Icu , -01(incoming), |
| 33 | (c)MCCB 4 pole thermal magnetic release 415 Volts 200 A, 25 KA, Ics=100%Icu , -02 |
| 34 | (d)MCCB 4 pole thermal magnetic release 415 Volts 160 A, 25 KA, Ics=100%Icu -2 |
| 35 | (e)MCCB 4 pole thermal magnetic release 415 Volts 63A, 16 KA, Ics=100%Icu , -02 |
| 36 | (f) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) |
| 37 | (g) Voltmeter ammeter digital type 0-500 V with inbuilt selector switch-01 No |
| 38 | (h) 3 Line multifunctional meter-01(Nos) |
| 39 | All as per item no 21 here in before but LT Panel consisting of following items (Near Temple) complete as specified and as directed. |
| 40 | (a Aluminium Bus Bar 400 A rating for 3 Phase and 200 A for Neutral - 01 Set |
| 41 | (b) MCCB 4 Pole thermal magnetic release 415 volts 250 A 36 KA,Ics=100%Icu , -01(incoming), |
| 42 | (c)MCCB 4 pole thermal magnetic release 415 Volts 200 A, 25 KA, Ics=100%Icu , -01 |
| 43 | (d)MCCB 4 pole thermal magnetic release 415 Volts 160 A, 25 KA, Ics=100%Icu -2 |
| 44 | (e)MCCB 4 pole thermal magnetic release 415 Volts 63A, 16 KA, Ics=100%Icu , -01 |
| 45 | (f) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) |
| 46 | (g) Voltmeter ammeter digital type 0-500 V with inbuilt selector switch-01 No |
| 47 | (h) 3 Line multifunctional meter-01(Nos) |
| 48 | All as per item no 21 here in before but LT Panel consisting of following items (Near CO Office) complete as specified and as directed. |
| 49 | (a) Aluminium Bus Bar 400 A rating for 3 Phase and 200 A for Neutral - 01 Set |
| 50 | (b) MCCB 4 Pole thermal magnetic release 415 volts 200 A 36 KA,Ics=100%Icu , -02(incoming+1 standby), |
| 51 | (c)MCCB 4 pole thermal magnetic release 415 Volts 63A, 16 KA, Ics=100%Icu , -05 |
| 52 | (d) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) |
| 53 | (e) Voltmeter ammeter digital type 0-500 V with inbuilt selector switch-01 No |
| 54 | (f) 3 Line multifunctional meter-01(Nos) |
| 55 | All as per item no 21 here in before but LT Panel consisting of following items (Near RP Gate) complete as specified and as directed. |
| 56 | (a) Aluminium Bus Bus Bar 400 A rating for 3 Phase and 200 A for Neutral - 01 Set |
| 57 | (b) MCCB 4 Pole thermal magnetic release 415 volts 250 A 36 KA,Ics=100%Icu , -01(incoming), |
| 58 | (c)MCCB 4 pole thermal magnetic release 415 Volts 200 A, 25 KA, Ics=100%Icu , -01 |
| 59 | (d)MCCB 4 pole thermal magnetic release 415 Volts 63A, 16 KA, Ics=100%Icu , -04 |
| 60 | (e) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) |
| 61 | (f) Voltmeter ammeter digital type 0-500 V with inbuilt selector switch-01 No |
| 62 | (g) 3 Line multifunctional meter-01(Nos) |
| 63 | Supply, installing ,testing and commissioing factory made and tested LT Outdoor Street/Flood Light Control Panel having platform mounted,suitable for 415 Volts 3 Phase and neutral 4 wire,50 HZ AC supply system shall be dust and vermin proof,protection class(IP-65) and made of CRCA sheet steel enclusure 3.15 mm thick suitable framework/Support made out of 40x40x5 mm MS Iron angle frame ,front opening type with aprons for cable entry,with proper ferrul and cable gland,internal wiring with PVC insulated multistranded copper conductor FRLS Cable of adequate size but not less than 4 sqmm,minimum 0.5 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc complete as specified and as directed. Note : The contractor shall submit detail Schematic Layout of the Panel Board for approval from Engr-in-Charge before procurement.The scope of work also comprising of the following :-(i) RYB Phase indicating LED type -01 set. (ii) MCB TPN 40Amps 4 polez,10 KA,50 HZ,415 Volts-01 No (iii) Power contactor 3 Pole,40 Amps.50 Hz,415 Volts-01 No. (iv) Time switch Digital Type,one dial daily,240/415 Volts,50 Hz-01 No. (v) Auto/Manual selector switch 6A-01 No.(vi) RYB Phase indicating light LED Type -03 No. |
| 64 | M&L ,earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth strip 32X6 mm by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.5 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed. |
| 65 | Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.(ii) Earthing strip and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule. |
| 66 | Note :- (i) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge. |
| 67 | M&L for road cutting of any thickness with depth of 0.6m depth and 0.1m width and laying of pipe and drawing cable and PCC 1:3:6 for road cutting all as per specfied and dirrected. |
| 68 | Supply and fix in replacement sheet metal enclosure powder painted MCCB DB VTPN 415 Volts 8 way double door vertical type with 200 Amps rated bus bar din rail neutral link with suitable for MCCB as incomer and concealed in wall all as specified and directed. Make : Havells cat part No-DHDLVDRWAOFO08 or equilant of Legrand,Schnider. |
| 69 | Supply and fix in replacement sheet metal enclosure powder painted MCCB DB VTPN 415 Volts 4 way double door vertical type with 200 Amps rated bus bar din rail neutral link with suitable for MCCB as incomer and concealed in wall all as specified and directed. Make : Havells cat part No-DHDLVDRWAOFO04 or equilant Legtand,Schnider. |
| 70 | S & F TPN DB, 415 volts, 4 way double door, With provision for TP 63A MCB as incomer and SP / TP MCBs as outgoing With neutral bars & earth bars complete all as specified and directed including making good to the disurbed surface matching with the existing also fixing MCB to the panel complete all as specified and directed. |
| 71 | Supply & fix in replacement sheet metal enclosure powder coated for MCB DB SPN 8 way double door with din rail and bus bar including making good to the disurbed surface matching with the existing complete all as specified and directed. |
| 72 | Supply and fix MCCB 415 volts 25 KA Four pole 100 Amps fixed type complete all as specified and directed. |
| 73 | Supply and fix MCCB 415 volts 25 KA Four pole 160 Amps fixed type complete alla s specified and directed. |
| 74 | Supply and fixing in replacement TPN 63 Amps 4P 415V 10KA 'B' curve complete with connection testing and commissioning complete all as specified and directed. |
| 75 | Supply and fix in replacement MCB SP 240 volts 6 to 32 Amps breaking capacity 10 KA 'B' Series rating complete all as specified and directed. |
| 76 | Supply and fix in replacement MCB SPN 240 volts 40 Amps breaking capacity 10 KA 'B' Series rating complete all as specified and directed. |
| 77 | Supply and drawing through the pole for making connections to the light fittings, three core, PVC insulated and sheated, Heavy duty,1100 volts grade,multistranded copper conductor (FRLS) cable 3Cx1.5 sqmm complete all as specified and directed. |
| 78 | Supply and fixing PVC pipe 25/20 mm through FRP Junction to street light clamp on the pole including all connecting accessories to the pole complete all as specified and directed. |
| 79 | Supply and fixing PVC coated flexible pipe 40 mm for protection of cable etc complete all as specified and directed. |
| 80 | NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysSep 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer