Tender For Provn Of False Ceiling And Improvement In Bldg No T-35(Trg Shed) And T-36(Mi Room) Of Med Regt,Spl Repair Of Cgi Sheet False Ceiling,Roofing And Rewiring In Bldg No T-49,50,51,52 Of (I) Engr Sqn, Provn Of 01 X Security Post Of 413(I) Engr
Tender Overview
Project Description
Tender for Provn Of False Ceiling And Improvement In Bldg No T-35(Trg Shed) And T-36(Mi Room) Of Med Regt,Spl Repair Of Cgi Sheet False Ceiling,Roofing And Rewiring In Bldg No T-49,50,51,52 Of (I) Engr Sqn, Provn Of 01 X Security Post Of 413(I) Engr Sqn &Spl Repair Of Existing Bdy Wall Of 3 ( I ) Armed Bde At Ratnuchak Mil Stn Under Ge Kaluchak.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling AC corrugated, semi corrugated sheets in roof covering complete all as specified and directed. |
| 2 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 MPs as in roof covering fixed with self tapping screws or L-type or J-type or cranked hook bolts complete all as specified and directed. |
| 3 | S&F pre painted galvalume aluminium zinc coating GI based corrugated /profile steel sheet 0.50 mm thick of an colour having tensile strength of 550 MPs as in ridge of roof fixed with self tapping screws or L-type or J-type or cranked hook bolts complete all as specified and directed. |
| 4 | S&F 600x600 mm grid frame of galvanised iron powder coated section incl supply and fixing 4 mm thick non asbestos designer E board and comprising of under mentioned section etc for grid frame (a) Suspended GI main runner 32x24 mm bulb Tee section fixed with 4mm dia GI bar @ 1200 c/c level shall be adjusted with fly/bionet screws. (b) Placed in position cross Tee 600 mm long and 24x26 mm bulb Tee section @ 605 mm c/c using shape and bionet fixing arrangement to secure main runners. (c) Ceiling GI 26x24 mm size bulb section installed 605 mm long in between cross Tee. (d) GI coated angle 24x24 mm fixed with PVC rawl plugs and GI screws to secure with walls. (e) All the fixing details shown on drg No CEPZ/STD/809/07 dt 03-11-2007 and as per manufacturer instructions as approved by GE |
| 5 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 6 | M&L for 15 mm thick rendering in CM 1:6 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 7 | M&L for 15 mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces with WPC finished even and smooth without using extra cement complete all as specified and directed. |
| 8 | M&L for prepartion of surace and applying two coat of oil bound distemper over wall puty surface on walls complete all as specitied and directed. |
| 9 | M & L Complete removal of the existing treatment and applying one coat of oil bound distemper on walls over wall putty complete all as specified and directed. |
| 10 | M&L Preparation new plastered surfaces and applying two coat of external weather proof paint over one coat of primer using mechanical vaccume machine. complete all as specified and directed. |
| 11 | M&L Complete removal of of existing treatment from wall, finishing the undulated surface by cement putty and applying two coats of weather proof paint over a coat of primer using mechanical vaccume machine.complete all as specified and directed. |
| 12 | M&L for applying one coats of synthetic enamelled paint on steel or iron surface based materials of any description , not other wise described over 10 cm width or girth including preparation of old surfaces. complete all as specified and directed. |
| 13 | Demolition of brickwork/stone masonary built in cement mortar including all quoins, arches, pillars, but excluding pre-cast concrete articles; complete all as specified and directed. |
| 14 | M&L Brickwork with sub class `B` old size brick straight or curved on plan exc 6 mtr mean radius built in cement Mortar 1:6 complete all as specified and directed. |
| 15 | Excavationover areas and not exc 1.5m in depth for the foundation and getting out in any type of soil ,complete all as specified and directed |
| 16 | Excavation over area in any type of soil and exc 1.5m in depth but not exc 3.0 m in depth for foundation and getting out in any type of soil complete all as specified and directed. |
| 17 | Returning filling in soil including spreading leveling watering and well ramming in layers not exceeding 25 cum ,complete all as specified and directed |
| 18 | Removal of excavated material as soils not exceeding 50m and at a level not exceeding 1.5m above the starting point and depositing .,complete all as specified and directed |
| 19 | M&L PCC 1:3:6 type D-2(40 mm graded stone agg) as in fdn , filling sub base to flooring ,mass concrete etc complete all as specified and directed |
| 20 | M&L Form work to sides of concrete fdn footing base of columns and raft beams sides and soffits (if any) of plinth beams ,complete all as specified and directed |
| 21 | M&L Form work to sides of pillars, posts, struts, pier, columns square, rectangular or polygonal rough finished surface of concrete ,complete all as specified and directed |
| 22 | M&L Form work to sides and soffits of floor or roof beams beam , lintels, cantilevers, shelves etc with rough finished ,complete all as specified and directed |
| 23 | M&L Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter,complete all as specified and directed |
| 24 | M&L Formwork to staircases with sloping or stepped soffits including risers and stringers(excluding landing) complete all as specified and directed |
| 25 | M&L Form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works not exc 20 cm wide and sides of PCC/RCC bands exc 10 cm but n.exc 20 cm wide with rough finished ,complete all as specified and directed |
| 26 | M&L Reinforced cement concrete M-25 (Nominal mix) using 20 mm graded crushed stone agggregate as in foundation beam, plinth beam base for columns etc complete all as specified and directed. |
| 27 | M&L Reinforced cement concrete M-25 (Nominal mix) using 20 mm graded crushed stone agggregate as in columns pillars posts etc complete all as specified and directed. |
| 28 | M&L Reinforced cement concrete M-25 (Nominal mix) using 20 mm gradd crushed stone agggregate as in beams, cantilevers, bressummers, lintel over 1.5 m span ,complete all as specified and directed |
| 29 | M&L RCC (Nominal mix) M-25 as in slabs supported on walls beams and columns in floors, roofs, landings, balcony, canopies, deck slabs and in shelves and the like ,complete all as specified and directed |
| 30 | M&L RCC (Nominal mix) M-25 as stairways including steps (square or spandril), string pieces, carriages, etc., completeall as specified and directed |
| 31 | M&L TMT bars (Fe 500), 10mm dia and over in reinforcement cut to length,bent to shape reqd, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (anealed) not less than 0.9mm dia or securing with clips,complete all as specified and directed |
| 32 | M&L TMT bars (Fe 500), 6 mm to 8 mm dia in reinforcement cut to length,bent to shape reqd, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (anealed) not less than 0.9mm dia or securing with clips ,complete all as specified and directed |
| 33 | All as per Ser Item No 32 here-in-before but 8 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders ,complete all as specified and directed |
| 34 | M & L for Brick work with sub class 'B' bricks having crushing strength not less than 100 kg/sqcm straight of curved on plan exceeding 6 m mean radius built in cement mortar 1:6 ,complete all as specified and directed |
| 35 | Hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick watered and well rammed to a true surface ,complete all as specified and directed |
| 36 | M&L for 100 mm thick cement concrete type C-2, 1:3:6 using 40 mm graded crushed stone aggregates in sub base to floor finishes ,complete all as specified and directed |
| 37 | M&L 75 mm thick PCC 1:3:6 type C-2 (40mm graded aggregate) as in plinth protection laid to an outward slope of not less than 1:12, cast in panels not exceeding 2.0 sqm areas with 6 mm wide joints. The joint shall be filled with mastic filling and 10 mm wide joints between the walls and plinth protection shall be filled with mastic filling and finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 38 | M&L Rendering 5 mm thick on fair face of concrete surface in CM 1:4 finished even and smooth without using extra cement ,complete all as specified and directed |
| 39 | M&L Rendering 15 mm thick on fair face of brick work or concrete surface in CM 1:4 (with water proofing compound, WPC measured & paid seprately) finished even and smooth without using extra cement ,complete all as specified and directed |
| 40 | Supply only liquid water proofing compound/admixture, ISI marked complete all as specified and directed. |
| 41 | M&L Rendering 5 mm thick on concrete surface as in ceiling in CM 1:3 finished even and smooth without using extra cement ,complete all as specified and directed |
| 42 | M&L PCC 1:2:4 type B-1 using 20 mm graded aggregates as in anchoring hold fast, parapets, coping, apex plates, bed plates and the like including weathering slightly rounded or chamfered angles and throating etc. complete all as specified and directed. |
| 43 | S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete complete all as specified and directed. |
| 44 | M&L for preparing newly plastered surfaces and applying three coats of white wash as in walls etc ,complete all as specified and directed Please Enable Macros to View BoQ information |
| 45 | M&L for preparing newly plastered surfaces and applying three coats of white wash as in walls etc ,complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender