Rural Development Government Departments Closing in 6 days TDR #57253868

Tender For Up-Gradation Of Health Infrastructure At Phc Building Muktapasi Of Kamakhynagaar Block In The District Of Dhenkanal Under Ama Hospital Inititatives_2Nd Phase

Issued by Government Departments · Dhenkanal, Odisha
Tender Value
66.74 Lakhs
Estimated cost
Bid Submission
04 Sep 2026
6 days left
EMD
68430
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dhenkanal → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Up-Gradation Of Health Infrastructure At Phc Building Muktapasi Of Kamakhynagaar Block In The District Of Dhenkanal Under Ama Hospital Inititatives_2Nd Phase

BOQ

Name of Work:- Up-gradation of Health Infrastructure at PHC building Muktapasi of Kamakhynagaar Block in the district of Dhenkanal under AMA HOSPITAL INITITATIVES_2nd Phase
Sl. No. Item Description
1Earth work in excavation in foundation in Stoney earth & gravel mixed with stone boulders with all leads and lifts including dressing and levelling the bed in layers not exceeding 0.3 m in depth including dewatering if necessary with cost of all labour and T&P work etc. Complete as per direction of Engineer-in-charge
2Earth work in excavation in foundation in Stoney earth & gravel mixed with stone boulders with all leads and lifts including dressing and levelling the bed in layers not exceeding 0.3 m in depth including dewatering if necessary with cost of all labour and T&P work etc. Complete as per direction of Engineer-in-charge
3Supplying, filling in F&P with clean course good river sand including watering, ramming, poking & compacting & cost, conveyance royalties, taxes of all materials, labour, T&P etc. Complete as per direction of Engineer-in-charge.
4Providing and laying P.C.C. of (1:3:6) with 2.5cm to 4 cm size crusher broken hard black granite metal with cost, conveyance, royalties, taxes of all materials, all labour,T&P etc. Complete as per direction of Engineer -in-charge. (A.C.C, Ultratech, Dalmia cement Use)
5Fly Ash Brick masonary in C.M. (1:6) in F & P including cost, conveyance, royalties, taxes of all materials, labour, T&P etc. Complete as per direction of the Engineer-in-charge.
6Fly Ash Brick masonary in C.M. (1:6) in superstructure including cost, conveyance, royalties, taxes of all materials, labour, T&P etc. Complete as per direction of the Engineer-in-charge.
7Providing16mm thick cement plaster in C. M. (1:6) finished smooth to inside surface including cost conveyance, royalty, taxes of all materials, labour, T&P etc. complete as per direction of the Engineer-in-charge.
812mm thick cement plastering (1:4) including punning and two coats of bitumen paniting with watering and curing etc. complete.
9Providing 12mm thick cement plaster with C.M. (1:6) finished smooth over kerb wall and patches including cost, conveyance, royalty & taxes of materials, labour, T&P etc. complete as per direction of the Engineer-in-charge.
106mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry treatment.
11Fixing of tiles in fioors,walls,treads landings etc on 25mm thick bed of c.m(1:1) with neat cement slury mixed with pigment to match the shade of the tiles including cost of tiles etc complete. ( Double Charge Premium) (Vetrified Tiles)
12Granite Tiles 10mm thick
13Supplying, fitting & Fixing tyles in dadoes skirting & riser of step on12mm thick C.P (1:3 ) jointed with neat cement slury, to match the shades of the tile including rubbing & polishing including cost of all etc complete
14Supplying, fitting & fixing M.S. window, grills, Grill doors & M.S. doors made of M.S.Angle & flats including fixing to walls with C.C.(1:2:4) with cost of all labour, T&P etc complete. (M.S Door)
15M.S Window
16M.S Grill
17Supplying and fixing-Fixing of Un-plasticised poly vinyl chloride (UPVC) (FENESTA/NCL VEKA LTD.) Casenent Door-60-Series duly manufactured using UPVC reinforced profiles of 60mm x 55mm x 2.5mm for outer frames 102mm x 60mm x 2.5mm casement Door Sash profile and 74mm x 60mm x 2.5mm mullion peofile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 2.0 mm prefabricated & welded through fusion welding the door sash shall be fitted with 12mm thick WPC Board of Greenply make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No. per set of sashes and th esystem isto be installed at the site using anchor fasteners, silicon rubber sealant,easy glazing/deglazing at site etc. including cost and conveyance of all material, accessories, labour charges, materials and product conforming to ASTM D 638-14,EN-447-95 and other applicable codes and standards. (Ref.-Office of the Engineer-In-Chife (CIVIL), Odisha Nirman Soudha,Bhubaneswar. Lt. No-16100)
18Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.
19Cement washing one coat including cost of all material and labouretc. Complete.
20Providing Plastic Emulsion two coatsover a coat of primer & over a coat of putty wall surface to make an even shade including cost, conveyance, royalties, taxes of all materials, labour, T&P etc. Complete as per direction of Engineer-in-charge.
21Painting TWO COATS to wall surface with weather paint over a coat of Priming of approved shade to give an even surfaceincluding cost conveyance
22Painting two coats with any approved Enamel Paint on wood/iron work including cost of all materials etc. complete.
23Cement Concrete (1:2:4) using 12mm size B.H.G.C.B. chips including cost conveyance royalaties Taxes of all materials etc complete
24Providing, supplying, fitting and fixing of stainless steel railing of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr C/C and stainless steel pipe bracing of size 32mm z 6mm circular pipe in three rows in stair case as per approved quality and design including cost, conveyance, taxes of all materials, cost of all labour, T&P etc. Complete as per direction of the Engineer-in-charge. (Ramp)
251' Ring & Sky Light
26Multi colour Branding as per norm & specification of HWC with approved quality weather paint including cost of materials, labour charges, T & P, etc. in complete
27Supplying, fitting and fixing Interlocking Paver Block including cost of all materials, takes labour T&P etc required for the work. per 1 sqm (Data for 9.3 sq.mt.)
28Construction of granular Sub-base by providing Granular sub-base Close Graded Grading-VI material as per table 400-1 ,spreading in unifrom layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC , and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for road & Bridge works(4th. Revision) .
29Providing and laying R.C.C. work in M-20 grade with 20mm and down grade black hard granite crusher broken stone chips of approved quality from quarry with smooth centering and shuttering hoisting and laying in layers including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. complete as per direction of the Engineer-in-charge. (A.C.C, Ultratech, Dalmia cement Use) (Base of Column)
30Plinth Band
31Column & Beam
32Roof slab
33Lintel(10\\")
34Chajja
35Roof Beam
36Providing M. S. Reinforcement for R.C.C. work including cutting, bending, binding & tying the grills & placing in position with cost of M. S. Rod and binding wire of 18 to 20 gauge including cost of all materials, labour, T&P etc. Complete as per direction of the Engineer-in-charge.
37providing fitting and fixing M.S. square Pipe for roof frame with flat with cost of all materials etc.
38Supplying and fixing G.C.I sheeet on roof drilling hole in wind ties including fixing of ridges valley wind ties etc excluding cost of fittings.
39Supplying, fitting and fixing chequre tile in floors of approved make conformaing to IS:13755 laid on 25 mm thick cement mortar (1:1) and filling joints with white cement of approved quality including cost of all materials, etc. required for the work all complete as per direction of E.I.C.
40Supplying, fitting and fixing Granite tile in floors of approved make conformaing to IS:13755 laid on 25 mm thick cement mortar (1:1) and filling joints with white cement of approved quality including cost of all materials, etc. required for the work all complete as per direction of E.I.C.
41Supplying fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification.
42Providing & fixing Anti-skid Ceramic floor tiles in floors treads or steps and landing on 20mm thick bed of cement mortar 1:4 (1cement : 4sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including cleaning complete
43Fixing Ceramic wall tiles in dados,skirting and in rises of steps on 12mm thick bed of cement plaster (1:3) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile.
44(EI) Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire = Finollex / L & T/ Anchor/ Havels/ V-Guard/ Greatwhite / Polycab) Group A (1.1.1)
45-do- .... Group B (1.1.2)
46-do- .... Group C (1.1.3)
47S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required.2 Modular box with base & cover (1.24.2)
488 Modular box with base & cover (1.24.5)
4912 Modular box with base & cover (1.24.6)
50S/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board (1.25.1+1.25.4)
51S/F of 6 Modular GI box in recess with suitable size of Modular base cover in front including providing and fixing 2 nos 3 pin 5/6 amp. Modular Socket out let & 5/6amp. Modular type switch,connection,painting etc. as required.(2X1.25.1+2X1.25.4)+6 MODULE
52S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required (1.25.3+1.25.5)+4 MODULE BOX
53S/F of computer board (Modular Type) consisting of 3 nos. of 5 amp plug and switch and 6 amp MCB, Indicator complete with wiring on 12 module M.S.box with B.k.cover(1.24.6 + 3 x (1.25.1+ 1.25.4) + 2.6.1)+Indicator
54Wiring for circuit I sub main wiring alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS- 694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required ( Make of wire- Finolex/ / Anchor/ Havels/ V-guard / HPL / L&T / Gratewhite / Polycab). -do- 2x1.5sqmm +1x1.5sqmm ( 1.8.1 )
55-do-2x2.5sqmm +1x1.5sqmm ( 1.8.2 )
56-do- 2x4sqmm +1x1.5sqmm ( 1.8.3 )
57-do- 4x6sqmm +2x2.5sqmm ( 1.8.10 )
58S/Fof 'B' series SP MCB of 5A to 32 Amp rating 240Volt \\"B\\" series MCB for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP)(2.6.1)
59S/F of Call bell/ Buzzer ISI marked sutiable for DC/AC single Phase 230 volts complete as required.(1.30)
60S/F of batten holder BK angle holder ISI marked including connection etc instead of ceiling rose (Make: Cona / Anchor / Havells / Greatwhite / Preeti / HPL) (1.29-1.28)
61Earthing with G.I. earth pipe 3 metre long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arragement and watering pipe etc. with charcoal and salt as required.(3.2)
62Supply and laying 6 SWG G.I wire in recess for loop earthing as required ( 3.17)
63S/F of 1200mm A.C. Ceiling fan (1Star) with all accessories and connections with out fan regulator (Make:Usha-Striker One/Neo/Crompton- highspeed/Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/ Great White-ALDOUS/Pollycab-Vital HS)
64S/F of electric step ceiling fan regulater in existing switch box including connection with 1.5sqmm FR PVC insulated single core multistrand copper conductor earthing the regulator as required.(1.38)
65S/F of 18-25 watt LED Tube light fitting compoete with all connection.\ including fixing and all accessories as per direction of Engineer-In-charge (Make: Havels / Phillps / Crompton / Polycab / HPL)
66Supply of instalation, Testing commissioning of 13 Watt. LED bulb
67S/F of 15A modular socket on 2 Modular Metal box for A.C
68S/F of 32A C series D.P. MCB for A.C (make: Legrand/Anchor/Havels/HPL)
69S/F of 25A Moter Starter switch for A.C (Make: Havells / Anchor/Le-Grand)
70S/F of 2000 VA Inverter with 2 nos. 180 Ah Tubular battery including trally arrangement (Make: Microtake/ Luminous/Exide)
71Fire bucket MS Capacity 9/10 Liters(Make:Life guard/Equivalent)
72Fire bucket stand suitable for 4 buckets(Make:Life guard/Equivalent)
73S/F of CO2 type fire Extinguisher of 4.5K.G. Capacity complete with delivery hose horn, Wheel type release valve,Locking rrangement,operation manual and bracket.operating temperature: -30 to +60(Brand Life guard or equivalent)
74S/F of 300 Exhaust fan with all accessoriesand connections (Make Usha-Aero Clean Plus DBB/ Polycab-Fresh on DBB/ Cropmton-Trans Air12\\" reversible/ Havells-Ventil Air DS(HS)/ Anchor-Anmol Delus R/ Orient-Power Flow DBB)
75S/F of Bamboo Bollard LED Garden Light (8W)( MAKE-HAVELLS/Equivalent).
76wiring to sub main with 1*1.5 mm2 single core multi strand copper wire for inverter wiring (1x1.5mm)
77S/F of 4 way (4+12) TPN MCB DB Single door (2.5.1)
78Supply of 3.5core 35sqmm PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade Armoured cable ( MAKE-HAVELLS/polycab/RR Kable/Rhino cable/equivalent)
79S/F of 40A FP 415V AC 10KA C Curve MCB( Make - Havells /Equivalent)
80MAIN DB Supply & fixing of 63A TPN Panel board 1. 63A 4P 30KA MCCB with Spreader,rotary handle, and UV relaease(Make- Legrand/Seimens/L&T/C&S)-1 No 2.63A Change over(Manual)-1 No 3. 63A COPPER bus bar- 2set 4.40A 4P MCB-6Nos. 5.SPD(Type1+2,50kA,3P+N)-1No 6.40A DP MCB- 4 nos 7.6-32 C Series SP MCB-4 Nos 8. Digital Volt meter & Ameter three phase-2Nos 9. All accesories & Connection (Rating & Danger borad)
81Laying of 35sq mm. 3½ Core cable on surface(5.5.2)
82Laying of 35sq mm. 3½ Core cable in ground(5.1.2)
83Supplying and making end termination with brass compression gland and aluminum lugs for 35sq mm. 3½ Core cable(5.8.21)
84S/F of following 2way single pole and neutral sheet steel MCB 250 V on recessed complete with tinned coper bus bar , neutral bar, earth bar,din bar, detachable gland plate, inter connections, phospatized and powder painted including earthing etc. as required(but without MCB)2 way single door(2.3.1 b)
85S/F of 32A rating \\"C\\" Series DP MCB (Make: L&T/Equivalent)
86Wiring for circuit/sub main alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20 mm dia non metallic heacy duty flexible conduit 1.6 mm wiring in existing conduit PVC conduit as required (make of wire-Finolex/L&T/Anchor/Havels/V-Guard).2x6 sqmm + 1 x 2.5 sqmm( 1.8.4)
87S/F of 'B/C/D' series SP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP) (2.6.1)
88S/F of 32A DP Switch with indicator(Make-Havells/Equivalent)
89Earthing with G.I. Earth pipe 3 mtr Long 40mm dia ISI marked including accessories & providing masonary enclosure with cover plate having locking arrangement & watering pipe with charcoal & salt as required (3.2 +3.3)
90Supply & laying 6 SWG G.I. wire in recess for loop earthing as required (3.17)
91Supply of cable for Street Light 3c X 1.5 sqmm FR PVC Round Sheathed Copper Conductor (MakePolycab or Equivalent )
92Provision of Armoured cable size 2x6sqmm (15)
93Laying of MV Cable upto 25sqmm in ground (5.1.1)
94Laying of MV cable upto 25sqmm on surface (5.5.1)
95S/F of 40 mm HDPE pipe for laying & protection of cable(Make:Sudhakar or Equivalent)
96Supply & Instalation of 7 meter octagonal Pole shall be designed to withstand the maximum wind speed as per IS 875.(Top 70 mm & Bottom 130 mm of 3 mm thickness with Base Plate (225X225X12mm) (MAKE-Bajaj/Utkarsh/RR Ispat/BPP )with Galvanised Double arm detachable 1.5 mtr bracket suitable for 70mm top. with 4 nos of Foundation bolts and nuts (20 mm dia 600-700mm Length) and anchor plate to be mounted on concrete Foundation (1.5'X1.5'X4' high) for errection of Pole firmly as per direction of Engineer in Charge.
97S/F of 60 wt. LED St. Light fitting with LED Electronic driver with all accessories & connection( Make- Crompton/Phillips/HPL/Polycab/Havells )
98Supply and installation of 6 mtr long hot dip galvanized Octagonal pole having base dia of 155 mm and top dia of 70 mm and plate thick ness of 4 mm or more complete with base plate 250x250x16mm and 4 nos. Jtype En 8 grade foundation bolts M24X750mm to withstand 180 KM / HR wind speed considering the weight & dimension of One no. Solar lights fixed on the top of the bracket . The Pole must be suiable to withstand 180 KM/Hr wind speed by considering the weight and wind expose area of one no Semi Integrated Solar lights at a height of 6 mtr above ground .Both the Octagonal Pole and EN8 grade fdn bolts must be manufactuered by Octagonal pole manufacturing company. Brackets & EN8 fdn bolts manufactured in third party Supplier/manufacturer shall not be acceptable.The necessary test reports of Octagonal Pole and EN8 grade fdn bolts must be submitted by the manufacturer for acceptance of product/TDS approval prior to start of the work.The pole manufacturer must submit the confirmation regarding 10 years or more design life of the pole. Construction of RCC foundation by using M20 grade RCC and Fe 415 grade reinforcement in the foundation by considering the SBC as 10 T per sq mtr and fixing the 4 nos. fdn bolts in that foundation for installation of pole with Solar light on that foundation. The work shall be excuted as per the direction of EIC Installation of 6 mtr pole and fixing the solar light on the top of the bracket so that all the solar lights shall be installed at a height of 6mtr above ground on that foundation by using suitable machinery by taking all safety precautions as per the direction of EIC. Make : - Utkarsh/RR Ispat/Vakrangee)
99Supply,installation,testing and commissioning of 40 W AIO Solar street lights having 100 Wp or more highly efficient Monocrystalline PV module & 12.8 V 42 Ah or more ( Lithium Ferrophosphate (LiFePo4) Battery having BIS ) which shall be inside the extruded aluminium luminaire housing (Theft retardant type), MPPT charge controller having > 92% efficiency & PIR Sensor. The initial lumen output of AIO street light shall be> 6400 lumen or more in CCT 6000K (+/-500K) (Lumen efficacy of 160 lm/w ) as per LM 79 report of NABL lab . The LED chip will be of OSRAM/NISCHIA/CREE/SEOUL Semiconductor only and should be with lenses for effective lighting distribution. The complete system & BMS should be designed to provide 2 days (24 Hrs) back up in dimming mode by activating PIR sensor and battery should be kept inside the luminaire and Mono Crystalline Panel (Made in India ) to be mounted on the top of the luminaire housing. The luminaire must be having IP 66 protection for critical component like (LED compartment, Driver compartment & Battery) . The AIO street light is having IK 08 .The luminaire should have the provision the tiltable/ adjustable mounting bracket to mount it on the top of the pole directly. Warranty on the AIO street lights must be 5 years .The solar lighting company must submit the warranty certificate in the department by mentioning 5 years warranty on complete lighting system against manufacturing defects. Solar lighting company has to repair/replace the lighting system if required against the manufacturing defect till compleiton of warranty period. The Agency/Contractor has to maintain the lighting system till the completion of warranty period by considering the periodical maintenance like panel cleaning in regular interval and rectifying the defect by engaging labour/machinery to make the lighting system operative till warranty period. The agency/contractor must submit declaration for maintaining the system till warranty period The following test reports/certifications must be submitted for the technical acceptance of the products .1. LM 79 REPORT NABL lab ) , 2. IK 08 (Report of NABL lab ), 3. IP 66 Report of NABL lab (The necessary test reports of NABL lab against the above must be submitted for any wattage of Solar Street lights for acceptance of product/TDS approval prior to start of the work. All the test reports must be in the name of Solar Lighting Company (Make:Crompton/Havells/Panasonic/Philips/Wipro)
100(PH) Earthwork in all kinds of soil in excavation of foundation trenches within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth etc all complete as per direction of the E.I.C. (Initial lift upto 1.5 mtr)
101From 1.5 mtr to 3.0 mtr depth
102Supplying all materials, labour, T&P and filling in foundation and plinth with river sand well watered and rammed including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per the direction of the E.I.C.
103Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
104Supplying all materials, labour, T&P and providing plain cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
105Supplying all materials,labour, T&P and providing Brick work with K.B.Brick having crushing strength not less than 75 Kg/CM2 with dimensional tolerence of +/- 8% in C.M including watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
106Supplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
107Supplying all materials, labour, T&P and providing cement punning on plastered surface including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
108Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling them after casting including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
109Supplying all materials, labour, T&P and providing M.S.reinforcements for RCC work including cutting, bending, binding, straightening and tying the grills and placing in position including cost of binding wire 18 to 20 gauge conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
110Supplying all materials, labour, T&P and providing Reinforced cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
111Supplying all materials, labour, T&P and making M.S. Step Iron in 20mm Dia M.S Steel bars and fixing into walls of Manhole/ Septic Tanks duly embeded in C.C(1:2:4) etc all complete as per P.H specification and direction of the E.I.C.
112Supplying all materials, labour, T&P and providing 50mm thick pre-cast R.C.C. baffle wall in R.C.C(1:1.5:3) including reinforcement cage using 12mm size HG chips fitted and fixed in position, finished smooth etc. complete including cutting grooves and mending good the damages etc all complete as per P.H specification and direction of the E.I.C.
113Supplying all materials, labour, T&P and providing 160mm dia P.V.C Tee inside the septic tank including cutting holes and duly embeded in P.C.C(1:1.5:3) using 12mm size HG chips fitted and fixed in position and mending good the damages etc all complete as per P.H specification and direction of the E.I.C.
114Supplying all materials, labour,T&P and providing 12mm thick cement flush pointing in C:M (1:3) to Brick Masonry works including watering curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
115Supplying all materials, labour,T&P and filling Foundation and Plinth with excavated earth including watering, ramming etc all complete as per direction of the E.I.C.
116Supplying all materials, labour T&P and fixing Ceramic Tiles in floors on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per specificat.
117Supplying all materials, labour T&P and fixing porcelain glazed tiles in dados skirting, on 12mm thick C.P. (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of Engineer-in-Charge.
118Providing fitting fixing Al door with anodized Al door section of 9202 as vertical member, 9201 as top, 9200 as bottom and middle member with frame section as 9221 with tapered clip no 4660 and frame to be completed by means of jointing angle no 1855 including cost of labour T&P hire charges of drilling machine labour charges etc complete with cost of laminated board. and as per direction of the Engineer in charge. 0.75 x 2.10 x 2
119Supplying all materials, labour, T&P and cutting holes through brick/stone masonary works including making good the damages in cm (1:4) for taking GI / PVC pipes and making good the damages etc all complete as per P.H specification and direction of the E.I.C. a) Cutting Hole (250 mm thick wall)
120Cutting Grooves in wall or floor
121Supplying all materials, labour T&P and fitting & fixing 10 Litres capacity low level cistern with a pair of cast iron of m.s. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float, c.p. brass handle, unions and couplings for connection with inlet, outlet and overflow pipe. 32 mm C.P flush bend 15mm PVC inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting inlet pipe with supply main etc. all complete as per specification and direction of E.I.C (Neycer/Cerra/ Parry ware/ Hindware)
122Supplying all materials, labour, T&P and fixing water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest etc all complete as per specification and direction of the E.I.C. a) 580mmx440mm size White Orissa pan (PARRYWARE, CERA, HINDWARE)
123European water closet with P trap plain with seat cover
124Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with C.I/M.S brackets painted white including holes in walls and making good the damages etc. all complete as per P.H specification and direction of E.I.C.-550mmx400mm size wash hand basin . (Cerra/ Parry ware/ Hindware)
125Fixing of Pedestrial for W.H.B
126Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with C.I/M.S brackets paintedwhite including holes in walls and making good the damages etc all complete as per specification and direction of the E.I.C. 610x510x200 mm stainless steel kitchen sink
127Supplying all materials, labour, T&P and fitting and fixing Brass/CP fittings of the following nominal bore with supply of all jointing materials etc. all complete as per specification and the direction of the E.I.C. (PLAZA/AMBAR) 15mm dia CP long body bib cock
12815mm dia CP short body bib cock
12915mm dia CP Two way angle/Bib Cock
13015mm dia CP Health Fuccet
13115mm dia CP Angle Stop Cock
13215 mm dia CP Pillar Cock
13315mm dia CP concealed stop cock
134a) Fixing of 20mmx450mm long CP towel rail
13525mm dia U-PVC Ball Valve[Metal Ball]
13632mm dia U-PVC Ball Valve[Metal Ball]
13715mm x 225mm long size CP shower arm
13815 mm dia CP Bib cock Elbow Action
13915 mm dia CP Pillar Cock Elbow Action
140450mmx125mm size plate Acrylic shelf
141CP towel ring
142Fixing of C.P Soap Holder
143Fixing of Glass Mirror 600mmx450mm size B.E mirror (fixed type)
14415 mm C.P flange
14515 mm C.P Extension piece 50 mm long
146Supplying Fitting fixing of Aquaguard cooler cum purifier (with all standard accessories) (Model-120 PSS RO + UV, Make-Uereka forbes ltd)
147Supplying all materials, labour, T&P and fitting and fixing U-PVC soil waste ventilating pipes of and fittings of the following outside diameter of 4kg/cm2 conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing etc all complete as per P.H specification and direction of the E.I.C. a) 110mm dia PVC SWR pipe
148110mm dia Plain bend
149110mm U-PVC door bend
150110mm U-PVC door Tee
151110mm dia cowl
152125mm dia CP grating
153110mm dia PVC P trap
154110mm dia PVC SWR Nahani trap without Jally
155110mm dia PVC SWR plain bend 450
156110mm PVC SWR plain Tee
15775 mm dia PVC SWR Pipe
15875mm PVC SWR plain bend
15975mm PVC SWR door bend
16075mm PVC SWR single equal door Tee
161Supplying all materials, labour, T&P and providing and fixing to wall or ceilling and floor PVC pipes conforming to (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor testing etc all complete as per P.H specification and direction of the E.I.C. a) 20mm dia C-PVC pipe (Internal)
16225mm dia ASTM/PVC pipe (External)
16332mm dia ASTM/PVC pipe (external)
164Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8 cm thick precast cover slab in CC (1:1.5:3) mix using 12 mm size H.G chips, foundation concrete (1:3:6) using 40 mm size HG metal on bed and around trap , !st class KB Brick work in CM (1:6) in F & P and inside 12 mm thick cement plaster (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap 150mmx150mm size C.I grating etc. all completed as per approved drawing, specification and direction of E.I.C. (a).Inside size 250mmx250mm
165Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizes with cement concrete (1:3:6) using 40 mm size HG metal on bed, 1st class KB Brick work in CM (1:6) moulding and shaping the channel inside and benching with C:C (1:1.5:3) using 12 mm size H.G chips, 12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in C.C(1:1.5:3) using 12 mm size H.G chips with RCC man hole cover, earth work excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved specification and direction of E.I.C Inside size 760mm x 760mm x 460mm
166Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class KB brick work in CM (1:6) for the remaining height at top, 12mm thick Cement Plaster (1:4) inside and outside over masonry brick work, gravel packing in the rear of well steining, RCC cover slab in CC (1:1.5:3) using 12mm HG chips, fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per approved specification and direction of the E.I.C. Construction of Soak way Pit Construction of Brick Soak way Pit (0.90 m dia x 2.10m Deep)
167Supplying all materials, labour, T&P and laying in trenches 4kg/cm2 U-PVC SWR soil waste ventilating pipes for sewer line of following dia in trenches (to slope or level)and jointing with supply of approved solvent cement by non-heat application method C.C (1:3:6) using 40mm size hard granite metal on bed of the trenches and all round concrete encashing with C:C (1:4:8) using 40 mm size H.G. metal, earthwork in excavation in trenches in all kinds of soil, refilling the same in a layer of 0.30mtr with watering, ramming and removing of surplus earth, testing the S.W. pipeline etc. all complete as per approved drawing, specification and direction of the E.I.C. Laying of 100 mm dia S.W Pipe line Haunch top
168Supplying all materials, labour, T&P and Fitting and Fixing of PVC water storage tank including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts, including hoisting upto a height of 5 mtr above G.Land placing the tank in required position including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 1000 Ltr capacity Sintex tank (1st Floor)
169Supplying all materials, labour, T&P and construction of masonry staging with providing 1st class K.B. Brick work in C.M.(1:6) of 0.46mtr height in staging, 12 mm cement plaster in C.M (1:6), R.C.C. Beam of 0.25mx0.30mx2.60m & roof slab of 1.40mx1.40m in C.C (1:1.5:3) using 12mm size H.G.Chips including centering, shuttering, bending and binding of rod etc watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 1000 Ltr capacit (1st Floor)
170Installation of pump setSupply of ISI mark 1.00 HP single phase vertical submersible pump set with discharge of 1800-2200 ltr/hour and a head of 45-60 Mtr of reputed make like KSB/TEXMO and equivlant including all cost conveyance and taxes etc all complete as per the direction of E.I.C.
171Supplying all labour, T&P and fitting abnd fixing of 1.00 HP single phase vertical submersible pump set with commissioning and testing etc all complete as per the direction of E.I.C.
172Supplying all labour, T&P and fitting abnd fixing of ISI mark DOL starter of reputed make like BCH or equivalent for 1.00 HP single phase submersible pump including all cost, conveyance of all taxes etc all complete as per the direction of E.I.C.
173BORE PROTECTION Supplying all materials, labour, T&P for construction of bore protection wall with providing sand filling, cement concrete (1:4:8) with HG metal & KB brick work in cement mortar (1:6) of 1.15 height, 16mm thick CP over the brick work, RCC slab of size 0.95 x 0.95 x 0.75 mtr avairage length in C 1:1.5:3, centering shutering including watering curing conveyance of all materials to work site with all cost, taxes etc all complete as per as per the direction of E.I.C. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57253868
AUTHORITY Government Departments
TENDER VALUE 66.74 Lakhs
LAST DATE 04-09-2026
Authority
Authority Name Rural Works Department
Work Description Tender for Up-Gradation Of Health Infrastructure At Phc Building Muktapasi Of Kamakhynagaar Block In The District Of Dhenkanal Under Ama Hospital Inititatives_2Nd Phase
Basic Detail
Tender No KNR-10/2026-27
Bidding Type Tender
Location
City Dhenkanal
State Odisha
Key Dates
Publish Date 29 Aug 2026
Submission Date 04 Sep 2026
Open Date 05 Sep 2026
Finance
Tender Value 66.74 Lakhs
Tender Fee 6000
EMD 68430
Exemption Available
Document List
4afea0c2-0cf2-4621-8b7f-8a77ab57a08a.html
BOQ_607491.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 29, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Sep 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

4afea0c2-0cf2-4621-8b7f-8a77ab57a08a.html

xls

BOQ_607491.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders