Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #57252994

Tender For Repair/Replacement Of Exhaust Fan/Geysers/Flame Proof Exhaust Fan/ Flame Prrof Wiring And Connected Work Alongwith Repair/ Replacement/ Cleaning Of Pvc Water Tank Etc At 901 Su Af Stn Nathatop

Issued by Statutory Bodies & Commissions/Committees · Udhampur, Jammu and Kashmir
Tender Value
25 Lakhs
Estimated cost
Bid Submission
14 Sep 2026
1 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Exhaust Fan/Geysers/Flame Proof Exhaust Fan/ Flame Prrof Wiring And Connected Work Alongwith Repair/ Replacement/ Cleaning Of Pvc Water Tank Etc At 901 Su Af Stn Nathatop

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 07-Sep-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-Sep-2026

BOQ

Name of Work:- REPAIR/REPLACEMENT OF EXHAUST FAN/GEYSERS/FLAME PROOF EXHAUST FAN/ FLAME PRROF WIRING AND CONNECTED WORK ALONGWITH REPAIR/ REPLACEMENT/ CLEANING OF PVC WATER TANK ETC AT 901 SU AF STN NATHATOP
Sl. No. Item Description
1Taking out Point wiring of any capacity and make from existing location including PVC/steel conduit fixed on roof/wall complete all as specified and directed.
2M&L in repair modular point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral including new PVC casing caping / conduit on surface for mounting of modular switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified.
3All as per serial item No 2.00 here-in-before but for 5 amp modular socket on independent board complete all as specified and directed
4All as per serial item No 2.00 here-in-before but for 5 amp modular socket on same board complete all as specified and directed
5All as per serial item No 2.00 here-in-before but for size 2.5 sqmm for 15 amp modular socket on independent board complete all as specified and directed
6Supply and fix modular switch , 1 way 6 Amp 1 module singe pole one way complete all as specified and directed
7Supply and fix modular switch , 1 way 16 Amp 1 module singe pole one way complete all as specified and directed
8Supply and fix modular socket outlet 3/5 pin, 16 amp, 2 module complete all as specified and directed.
9M&L in repair modular white cover outer plate/frame and metal flush box, 8 module complet all as specified and directed by Engr - in Charge
10M&L in repair modular white cover outer plate/frame and metal flush box, 6 module complet all as specified and directed by Engr - in Charge
11M&L in repair modular white cover outer plate/frame and metal flush box, 3 module complet all as specified and directed by Engr - in Charge
12M&L in repair modular white cover outer plate/frame and metal flush box, 1/2 module complet all as specified and directed by Engr - in Charge
13Supply and fix modular Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and as directed.
14M&L in repair point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral including PVC casing caping / conduit on surface for mounting of switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly including pressed steel sunken box, painted with one coat of red oxide primer and 3 mm thick top cover hylam sheet of required colour complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified.
15All as per serial item No 14 here-in-before but for 5 amp socket on independent board complete all as specified and directed
16All as per serial item No 14 here-in-before but for 5 amp socket on same board complete all as specified and directed
17All as per serial item No 13.00 here-in-before but for size 2.5 sqmm for 15 amp modular socket on independent board complete all as specified and directed
18Supply and fix Switch Piano,flush type 6 Amp single pole,oneway complete all as speciifed and as directed
19Supply and fix outlet socket 3 pin 16 amp fllush type compelete all as specified and directed.
20Supply and fix Switch Piano,flush type 16 Amp single pole,oneway conforming to IS-3854 complete all as speciifed and as directed
21Supply and fix Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and as directed.
22S&F in repair Recess mounting type fitting LED indoor luminaire powder coated, CRCA or powder coated aluminium panel 2' x 2' (Appx) system wattage 36 watt (cool white), minimum system lumen efficacy not less than 80 % , CRI not less than 80, colour temperature not less than 6000 K, power factor not less than 0.95, LED driver with constant output voltage and current at input voltage of 140volt to 285 volt AC, 50 HZ, Surge Protection>2 KV, IP protection IP 20, powder coated housing with ashthetic bottom frame, with excellent heat dissipation through high thermal conductivity, high efficiency transulence diffuser, suitable for any type of ceiling system including connection with PVC insulated copper conductor 3 core cable of 0.50 sqmm complete all as specified. Make Havells / crompton/ Philips
23Supply and fix in repairs LED Tube lights fitting Four feet 1 x 20 Watt LED Up-Down Batten(Yellow uplight relax mode and white downlight work mode), 220V AC, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy, with driver, holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge. (CAT PART NO: PHILIPS TWINGLOW 20W GU24)./ HAvells / Crompton
24Supply and fix in replacement of LED lights fitting Two feet 1x 10 Watt LED 6500 K, 220V,AC decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy, with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete inc taking down all as specified and directed by Engr-in-Charge. Make Havells / crompton/ Philips
25Supply, installation, testing and commissioning in repair of decorative wall light complete with powder-coated metal body, E27 lamp holder, wall mounting base, internal wiring, fixing screws, raw plugs, connector strip and all accessories required for complete installation. The fitting shall be mounted on wall/column as directed by the Engineer-in-Charge. LED lamp (if required), wiring from nearest junction box to the fitting, conduit and switch shall be measured and paid separately unless otherwise specified. including taking down old unsv tubelight Make: Philips cat no Muziris / Crompton/ havells
26Supply, Installation, Testing and Commissioning of LED Bedside Wall Light, wall-mounted type, complete with integrated LED (3 W or approved equivalent), flexible gooseneck reading arm, individual ON/OFF switch, die-cast aluminium/metal body with grey/black finish, electronic driver, mounting plate, internal wiring, fixing screws, rawl plugs and all accessories required for complete installation. The fitting shall be suitable for operation on 230 V AC, 50 Hz and installed as directed by the Engineer-in-Charge. inc taking down old unsv tube light Make: Philips / Crompton/ havells
27Supply only E27 bulb of warm white / CDL of minimum wattage of 9 watt for item ser no. 25, all as specified and directed by Engr-in-Charge.
28S&F sheet steel powder coated distribution board SPN 12 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, double door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB]
29M&L for in repair in repairs MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed.
30M&L for in repair MCB SP 6-32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed.
31M&L Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 2.5 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 2.5 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC concealed conduit , heavey duty and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 2.5sqmm cable and one RM of 2.5 sqmm cable as earth wire alongwith conduit shall be considered as one running metre for payment purpose.
32M&L in repair rigid non-metallic PVC conduit of dia not less than 20 mm including of boxes (junction/terminal) all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, fixing on roof/wall including fixing arragement like saddledd and other material complete all as specified and directed.
33Supply and fixing of inverter LED tube light fitting 20 watt with minimum 04 hours battery back up 26 Mah LI-ION battery voltage surge protection, backup lumen > 450 lumen batten with diffuser and including 20 watt LED height efficient, AC 220-240 V, 50 Hz and connecting with copper conductor flexible cable of size 0.50 sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed Engr-in-Charge. Make: Philips/ Wipro/Jaguar.
34Supply and fix in replacement of flame proof (FP) point wiring using approved colour coding as per IS for light/fan controlled by one way flame proof switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through ERW rigid steel in existing conduit ISI marked with all flame proof conduit fittings and accessories fixed is walls/ceiling with proper fixing arrangment including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified.
35Supply and fix in replacement of flame proof (FP) point wiring using approved colour coding as per IS for light/fan controlled by one way flame proof switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through ERW rigid steel in new conduit ISI marked with all flame proof conduit fittings and accessories fixed is walls/ceiling with proper fixing arrangment including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified.
36Supply and fix in replacement of flame proof (FP) point wiring using approved colour coding as per IS for light/fan controlled by one way flame proof switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through new ERW rigid steel on surface ISI marked with all flame proof conduit fittings and accessories fixed is walls/ceiling with proper fixing arrangment including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified.
37Supply and fix in replacement of flame proof (FP) point wiring using approved colour coding as per IS for light/fan controlled by one way flame proof switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through existing ERW rigid steel on surface ISI marked with all flame proof conduit fittings and accessories fixed is walls/ceiling with proper fixing arrangment including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified.
38Supply and fix in replacement of flame proof (FP) LED light fitting Four feet 1x/20 Watt 4 Feet, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
39Supply, Installation, Testing and Commissioning of 250 W LED Flameproof Light Fitting, suitable for installation in Zone 1 & Zone 2 hazardous areas (Gas Group IIA/IIB or as specified), with Ex d certified die-cast aluminium housing, toughened glass diffuser, IP66 protection, integrated LED driver, operating voltage 230 V AC, 50 Hz, colour temperature 5700 K /4000 K ± 500 K, CRI ≥70, efficacy ≥120 lm/W, corrosion-resistant epoxy powder-coated finish, complete with flameproof cable entry, mounting bracket, stainless steel hardware, glands, stopping plug, earthing terminals, all accessories, testing and commissioning, as required for satisfactory operation including taking down ol unsv Flameproof tubelight/ conventional light fitting and as directed by the Engineer-in-Charge.Make: Crompton/ Sudhir/Shyam.
40Supply, Installation, Testing and Commissioning of 150 W LED Flameproof Light Fitting, suitable for installation in Zone 1 & Zone 2 hazardous areas (Gas Group IIA/IIB or as specified), with Ex d certified die-cast aluminium housing, toughened glass diffuser, IP66 protection, integrated LED driver, operating voltage 230 V AC, 50 Hz, colour temperature 5700 K /4000 K ± 500 K, CRI ≥70, efficacy ≥120 lm/W, corrosion-resistant epoxy powder-coated finish, complete with flameproof cable entry, mounting bracket, stainless steel hardware, glands, stopping plug, earthing terminals, all accessories, testing and commissioning, as required for satisfactory operation including taking down ol unsv Flameproof tubelight/ conventional light fitting and as directed by the Engineer-in-Charge.
41Supply, Installation, Testing and Commissioning of 90 W LED Flameproof Light Fitting, suitable for installation in Zone 1 & Zone 2 hazardous areas (Gas Group IIA/IIB or as specified), with Ex d certified die-cast aluminium housing, toughened glass diffuser, IP66 protection, integrated LED driver, operating voltage 230 V AC, 50 Hz, colour temperature 5700 K /4000 K ± 500 K, CRI ≥70, efficacy ≥120 lm/W, corrosion-resistant epoxy powder-coated finish, complete with flameproof cable entry, mounting bracket, stainless steel hardware, glands, stopping plug, earthing terminals, all accessories, testing and commissioning, as required for satisfactory operation including taking down ol unsv Flameproof tubelight/ conventional light fitting and as directed by the Engineer-in-Charge.
42Supply and fix in replacement of flame proof (FP) rotary switch single pole on and off with cable termination box of 16 Amps rating 230 Volts complete all as specified and directed.
43M&L in repair Flame proof (FP) sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4 sqmm (nominal area) 1100 volts grade cable as earth wire including drawn through steel conduit , heavey duty and connected to main board and making good disturbed surface after taking out old unserviceable flame proof / non flame proof sub main wiring and disposing from site complete all as specified and as directedNote: Two runs each of 4 sqmm cable and one RM of 4 sqmm cable as earth wire shall be considered as one running metre for payment purpose.
44M&L in repair Flame proof (FP) sub main wiring using approved colour coding as per IS with four single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4 sqmm (nominal area) 1100 volts grade cable as earth wire including drawn through steel conduit , heavey duty and connected to main board and making good disturbed surface after taking out old unserviceable flame proof / non flame proof sub main wiring and disposing from site complete all as specified and as directedNote: four runs each of 4 sqmm cable and one RM of 4 sqmm cable as earth wire shall be considered as one running metre for payment purpose.
45Supply and fixing of Flame proof FH/199 FLP/WP flexible Metalic Conduit in SS304-300MM Length with3/4\\" ET(M)X3/4\\" ET complete all as specifeied and asd directed.
46Supply and fixing of Flame proof Bn/C/165FLP/WP Bends 90 degree or 45 degree for conduit with3/4\\" ET entries complete all as specified and as directed.
47S&F in recess on wall ERW Conduit of size 20/25mm, ISI marked, heavy duty with all Conduit Accessories and Making Good Surfaces to match the Exiting Treat-ment (as per Site requirement) including Taking down/out Old Unserviceable Conduit, complete all as per specified and as directed.
48Supplying & fixing flame proof, switch socket & plug combined made of aluminum alloy LM-6 having 2 pole + earth suitable for 250 volts supply and current rating of 16 Amps complete all as specified & directed.
49Supplying & fixing flame proof, switch socket & plug combined made of aluminum alloy LM-6 having 4 pole + earth suitable for 415 volts supply and current rating of 16 Amps complete all as specified & directed.
50Supply and fix in replacement of FLP/WP Lighting distribution panel board encloser single pole & neutral 230 volts 8 way complete with appropriate size bus bar and neutral link suitable for class 1 Zone 1 & Ex IIC suitable for & including following accessories including taking down old unsv normal / Flame proof DB : (i) incomming : MCB 2P,16 Amps/25Amps/25A-1NoOut going: MCB 1P ,6 Amps/10A- 6 Nos with internal busbar & wiring up to terminal
51Supply and fix in replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp complete all as specified and as directed.
52M&L disconnecting existing tanks of size 2000 Ltrs setting aside (for lowering if required) and cleaning of all scaling and dirt etc with bleaching powder and making it germ free including hoisting, reconnecting and refixing in position and writting date of cleaning and next due date with white paint complete all as specified and directed by Engr-in-charge.
53All as per serial item No 52 here-in-before but for capacity of PVC tank 1000 Ltrs complete all as specified and directed
54All as per serial item No 52 here-in-before but for capacity of PVC tank 500 Ltrs complete all as specified and directed
55Supply, installation, testing and commissioning of Triple Puff technology, 8 layer 500 - litre vertical polyethylene water storage tank, UV-stabilized, food-grade inner layer, rotationally moulded, suitable for potable water storage, complete with inlet, outlet, overflow, drain connections, airtight lid, all necessary fittings, supporting accessories, and fixing in position, including testing for leak-proof performance, including old unsv PVC tank complete as directed by the Engineer-in-Charge. Make Flowtex/ Sintex
56Supply, installation, testing and commissioning of Triple Puff technology, 8 layer 1000 - litre vertical polyethylene water storage tank, UV-stabilized, food-grade inner layer, rotationally moulded, suitable for potable water storage, complete with inlet, outlet, overflow, drain connections, airtight lid, all necessary fittings, supporting accessories, and fixing in position, including testing for leak-proof performance, including old unsv PVC tank complete as directed by the Engineer-in-Charge. Make Flowtex/ Sintex
57Supply and fix GI Nipple of 15 mm dia fixed on wall/roof including necessary connecion all as specified and as directed.
58All as per item No 57 hereinbefore but of 20 mm dia complete all as specified and directed.
59All as per item No 57 hereinbefore but of 25 mm dia complete all as specified and directed.
60All as per item No 57 hereinbefore but of 40 mm dia complete all as specified and directed.
61Taking down/removing existing damaged / unserviceable Nipple from the pipe line laid in trench/wall/roof complete all as specifed and directed.
62Supply and fix GI reducer of size 40 x 20 mm fixed on wall/trench/roof including necessary connection complete all as specified and directed.
63All as per item No 62 hereinbefore but of 25 x 15 mm dia complete all as specified and directed.
64All as per item No 62 hereinbefore but of 50 x 40 mm dia complete all as specified and directed.
65All as per item No 62 hereinbefore but of 80 x 40 mm dia complete all as specified and directed.
66All as per item No 62 hereinbefore but of 80 x 50 mm dia complete all as specified and directed.
67Taking down/removing existing damaged / unserviceable reducer from the pipe line laid in trench/wall/roof complete all as specifed and directed.
68Taking out burnt/damaged unserviceable exhaust fan 200 to 250 mm motor of any make and size for repair like motor, blower and fins including connecting/disconnecting of electric connection with all accessories complete all as specified.
69M&L for rewinding of fans motor of capacity 200 to 250 mm of any make with super enameled copper winding wire of appropriate size/same gauge as original including packing insulating material, soldering, varnishing, assembling and testing and refixing using etc of same places complete all as specified.
70S&F in replacement condenser/capacitor suitable for 230 volts single phase for exhaust fan/cabin fan/pedestal fan of capacity 2.5/ 3.15 mfd ISI mark suitable for ex fan of capacity 200 mm to 250 mm capacity including necessary connection complete all as specified.
71M&L in repair/replacement of exhaust Fan MS/iron body suitable for 200 mm to 250 mm and any make and repairing the following items of existing sizes.
72Supply and fix in replacement of exhaust fan Louver iron shutter for size 200 mm to 250 mm sweep along with fixing arrangement complete all as specified and directed
73Supply and fix in replacement of exhaust fan frame with nut bolts etc size 200 mm to 250 mm sweep complete all as specified and directed
74Taking out burnt/damaged unserviceable exhaust fan 300 to 450 mm motor of any make and size for repair like motor, blower and fins including connecting/disconnecting of electric connection with all accessories complete all as specified.
75M&L for rewinding of fans motor of capacity 300 to 450 mm of any make with super enameled copper winding wire of appropriate size/same gauge as original including packing insulating material, soldering, varnishing, assembling and testing and refixing using etc of same places complete all as specified.
76S&F in replacement condenser/capacitor suitable for 230 volts single phase for exhaust fan/cabin fan/pedestal fan of capacity 2.5/ 3.15 mfd ISI mark suitable for ex fan of capacity 300 mm to 450 mm capacity including necessary connection complete all as specified.
77M&L in repair/replacement of exhaust Fan MS / iron body suitable for 300 mm to 450 mm and any make and repairing the following items of existing sizes.
78Supply and fix in replacement of exhaust fan Louver iron shutter for size 300 mm to 450 mm sweep along with fixing arrangement complete all as specified and directed
79Supply and fix in replacement of exhaust fan frame with nut bolts etc size 300 mm to 450 mm sweep complete all as specified and directed
80S&F BLDC Exhaust fan of ize 250 mm sweep, single phase 230V AC, 1400 RPM plastic body with louvers including electric connection from ceiling rose to fan connector with PVC insulated 2 core copper cable of size 0.75 sq.mm complete all as directed.
81S&F Exhaust fan of size 300 mm sweep, single phase 230V AC, 1400 RPM plastic body with louvers including electric connection from ceiling rose to fan connector with PVC insulated 2 core copper cable of size 0.75 sq.mm complete all as directed.
82S&F Heavy duty Exhaust fan of size 300 mm sweep, single phase 230V AC, 1400 RPM metal body with louvers including electric connection from ceiling rose to fan connector with PVC insulated 2 core copper cable of size 0.75 sq.mm complete all as directed.
83S&F Exhaust fan of size 450 mm sweep, single phase 230V AC, 1400 RPM metal body with louvers including electric connection from ceiling rose to fan connector with PVC insulated 2 core copper cable of size 0.75 sq.mm complete all as directed.
84S&F Heavy duty Exhaust fan of size 450 mm sweep, single phase 230V AC, 1400 RPM metal body with louvers including electric connection from ceiling rose to fan connector with PVC insulated 2 core copper cable of size 0.75 sq.mm complete all as directed.
85M&L for cutting opening in to existing one brick thick walls for fixing the exhaust fan of size 250 mm in the required shape and making good the disturbed surfaces with cement mortar and finishing the surfaces to match the existing surfaces complete all as directed.
86All as per serial item No 85.00 here-in-before but for size 300 mm sweep complete all as specified and directed
87All as per serial item No 85.00 here-in-before but for size 450 mm sweep complete all as specified and directed
88M&L servicing for gysers of capacity 25 Ltrs for checking of general leakage of water from main body with cleaning inner tank, removing of sludge from element as per existing elements including connecting and disconneting of electric connection from existing location and refixing the same after completion of job complete all as specified and directed
89All as per item No 88.00 hereinbefore but capacity of geyser 50 Ltrs complete all as specified and directed.
90M&L for shifting of geyser from existing location to new location as per direction by Engr - in - charge of capacity as per existing including fixing arrangement like fastern, mounting pad with drilling of hole in roof/wall and making good surface complete all as specified and directed. Please Enable Macros to View BoQ information
91M&L for shifting of geyser from existing location to new location as per direction by Engr - in - charge of capacity as per existing including fixing arrangement like fastern, mounting pad with drilling of hole in roof/wall and making good surface complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57252994
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 14-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Exhaust Fan/Geysers/Flame Proof Exhaust Fan/ Flame Prrof Wiring And Connected Work Alongwith Repair/ Replacement/ Cleaning Of Pvc Water Tank Etc At 901 Su Af Stn Nathatop
Basic Detail
Tender No GEAFU-61/2026-27
Bidding Type Tender
Location
City Udhampur
State Jammu and Kashmir
Key Dates
Publish Date 07 Sep 2026
Submission Date 14 Sep 2026
Open Date 16 Sep 2026
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Not Available
Document List
BOQ_881870.xls
e34fd5d9-7fe0-4644-8d4e-9bb84e998193.html
TENDER61.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 14, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Sep 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Sep 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_881870.xls

html

e34fd5d9-7fe0-4644-8d4e-9bb84e998193.html

pdf

TENDER61.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders