Tender For Repair/Maint And Replacement Of Lt Panel, Feeder Pillar Boxes, Lt Poles, Lt Switch Gears, Lt Ug Cable With Allied Works In Roorkee Station, Under Ge Roorkee
Tender Overview
Project Description
Tender for Repair/Maint And Replacement Of Lt Panel, Feeder Pillar Boxes, Lt Poles, Lt Switch Gears, Lt Ug Cable With Allied Works In Roorkee Station, Under Ge Roorkee
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Sep-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Labour only for stretching, tightening, fixing and connecting existing ACSR conductor and GI wire of HT/LT overhead line of any size and type, including all necessary binding, jointing, sagging and making proper connections complete all as specified and directed. Measurement shall be made in Running Metre (RM) of conductor line 2 Conductors without GI wire |
| 2 | All as per item No 1 here-in-before but 5 Conductors with GI wire |
| 3 | All as per item No 1 here-in-before but 6 Conductors with GI wire |
| 4 | Supply, laying & testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100V grade, cross sectional are 3.5 core 240 sq.mm. |
| 5 | All as per item No 4 here-in-before but 3.5 core 185 sq.mm. |
| 6 | All as per item No 4 here-in-before but 3.5 core 150 sq.mm. |
| 7 | All as per item No 4 here-in-before but 3.5 core 120 sq.mm. |
| 8 | All as per item No 4 here-in-before but 3.5 core 95 sq.mm. |
| 9 | All as per item No 4 here-in-before but 3.5 core 70 sq.mm. |
| 10 | All as per item No 4 here-in-before but 3.5 core 50 sq.mm. |
| 11 | All as per item No 4 here-in-before but 3.5 core 35 Sqmm. |
| 12 | All as per item No 4 here-in-before but 4 core 25 sq.mm |
| 13 | All as per item No 4 here-in-before but 4 core 16 sq.mm. |
| 14 | All as per item No 4 here-in-before but 4 core 10 sq.mm. |
| 15 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for ducting and Laying in LT underground cable,depth for ducting and for finding of the cable fault in LT underground cable and returning filling (including reusing old bricks and sand) the same after rectification of the cable fault and Pole/stay in any type of soil complete all as specified and directed |
| 16 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed. |
| 17 | Removing surplus spoil to a distance not exceeding 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and directed. |
| 18 | Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 75 mm, inner dia 63 mm, confiming to IS-16205 (Part 24) with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed |
| 19 | Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 90 mm, inner dia 75 mm , confiming to IS-IS-16205 (Part 24) with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls / pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed |
| 20 | Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia120 mm, inner dia 103.5 mm , confiming to IS-IS-16205 (Part 24) with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls / pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed |
| 21 | M&L for Cutting existing wall/PCC hard standing or tile work of any type incl material and labour for laying of GI tube light grade 40 mm bore for cable protection with all fittings and making good all disturbed surfaces using the same material and finish to restore them to their original condition after completion of work. complete all as specified and directed |
| 22 | M & L for Horizontal Boring of holes under road, pavement, hard standing by trenchless technology using GI Pipe of 40 mm required dia and necessary machine suitable for 0.4 mpa working pressure complete all as specified and directed. Note :- GI pipe Light grade will be measeured and paid saperately under respected item. |
| 23 | M & L for Horizontal Boring of holes under road, pavement, hard standing by trenchless technology using GI Pipe of 80 mm required dia and necessary machine suitable for 0.4 mpa working pressure complete all as specified and directed. Note :- GI pipe Light grade will be measeured and paid saperately under respected item. |
| 24 | M & L for Horizontal Boring of holes under road, pavement, hard standing by trenchless technology using GI Pipe of 100mm required dia and necessary machine suitable for 0.4 mpa working pressure complete all as specified and directed. Note :- GI pipe Light grade will be measeured and paid saperately under respected item. |
| 25 | Taking down old rusted galvanized iron pipe and providing galvanized pipe 100 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, comple te all as specified and directed. |
| 26 | Taking down old rusted galvanized iron pipe and providing galvanized pipe 80 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. |
| 27 | Taking down old rusted galvanized iron pipe and providing galvanized pipe 40 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. |
| 28 | M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed. |
| 29 | M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed. |
| 30 | M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed. |
| 31 | M&L for earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level and covered surrounded from all sides with mixture of charcoal and common salt in alternate layers upto 15cm above top of plate and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber (chamber size not less than 300x300x300mm interier diamentions), RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc. complete all as specified and directed.NOTE: The unit rate includes earth strip and new GI protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point. |
| 32 | Material and labour for preparation of old painted surfaces using polish and painting two coats of aluminium paint on exposed surfaces to steel tubular 4 pole structure of 11 mtr including crossarms, Bracket etc including 5 Nos. of strip / bands painted with post office red and nevy blue colour (300 mm each) in alternate layer from coaping, marking of pole number with black synthetic enamel paint 2.5 cm height including in 6\\" dia circle complete all as directed. |
| 33 | All as per item No 32 here-in-before but LT/HT 2 pole structure |
| 34 | All as per item No 32 here-in-before but LT/HT Pole upto 11 mtr (Single pole). |
| 35 | All as per item No 32 here-in-before but LT/HT Pole upto 9 mtr (Single pole). |
| 36 | Supply & fix PVC Junction box of size 350x250x150 mm with Aluminium bus bars 04 Nos fixed on pole with the help of MS nuts bolts and MS clamps-2 Nos of size 40mm X 5mm thick with one No MCB SP 6 Amp capacity includes making suitable hole on pole to take out connections to fitting if required at site and PVC insulated sheathed multistranded copper conductor 3 core 1.5/2.5 Sqmm for making connection from junction box to security light fitting complete including cable glands for incoming and outgoing cables complete all as specified and directed |
| 37 | M&L for feeder pillar bus bar box of size of size 900x900x500mm of outdoor type, double door, both side openable, locking arrangement, kiosk type, powder coated, 3 mm thick MS sheet water proof hinged, having 4 Nos aluminium bus bar of 400 Amp duly colour coded mounted on porcelain insulator, with provn of 06 Nos outgoings including MCCB 200 Amps, 4 pole, 36 kA,= 01 No, LED indicator (RYB), 08 Nos, holes in bottom with plate for inlet and outlet cable with suitable size of brass cable gland and mild steel stand for mounting of panel board made of angle iron of size 50 mm X 50 mm X 6 mm, 1.05 metre high (450mm below ground level and 600mm above ground) along with necessary cement concrete for grouting of panel stand and connecting the panel with earthing complete all as specified and directed by Engineer-in-Charge.Note : (a) Feeder pillar box shall be got fabricated from CPRI approved and shall be from approved list of manufaturer only and depth of panel not less than 55CM.(b) Electric connection between MCCB and Busbar shall be with aluminium strip links duly colour coded.(c) PCC for foundation shall be paid in respective item of this schedule. Please Enable Macros to View BoQ information |
| 38 | M&L for feeder pillar bus bar box of size of size 900x900x500mm of outdoor type, double door, both side openable, locking arrangement, kiosk type, powder coated, 3 mm thick MS sheet water proof hinged, having 4 Nos aluminium bus bar of 400 Amp duly colour coded mounted on porcelain insulator, with provn of 06 Nos outgoings including MCCB 200 Amps, 4 pole, 36 kA,= 01 No, LED indicator (RYB), 08 Nos, holes in bottom with plate for inlet and outlet cable with suitable size of brass cable gland and mild steel stand for mounting of panel board made of angle iron of size 50 mm X 50 mm X 6 mm, 1.05 metre high (450mm below ground level and 600mm above ground) along with necessary cement concrete for grouting of panel stand and connecting the panel with earthing complete all as specified and directed by Engineer-in-Charge.Note : (a) Feeder pillar box shall be got fabricated from CPRI approved and shall be from approved list of manufaturer only and depth of panel not less than 55CM.(b) Electric connection between MCCB and Busbar shall be with aluminium strip links duly colour coded.(c) PCC for foundation shall be paid in respective item of this schedule. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents