Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #57251994

Tender For Provn Of Fly Proof Door Wooden In Bldg No Al 77 78 And 79 Of Otm Accn At 4 Garh Rif And Provn Of Two Wheeler Parking Shed At Ra Bazar (Fafa Jcos) And Provn Of Shed And Interlocking Tiling In Bungalow No P-5 Bldg No 14 At Joggers Park And P

Issued by Statutory Bodies & Commissions/Committees · Lucknow, Uttar Pradesh
Tender Value
39.14 Lakhs
Estimated cost
Bid Submission
19 Sep 2026
5 days left
EMD
78280
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Fly Proof Door Wooden In Bldg No Al 77 78 And 79 Of Otm Accn At 4 Garh Rif And Provn Of Two Wheeler Parking Shed At Ra Bazar (Fafa Jcos) And Provn Of Shed And Interlocking Tiling In Bungalow No P-5 Bldg No 14 At Joggers Park And Provn Of Chain Link Fencing Bldg No Al-99 And Provn Of 01 X Shed For New Religious Hall At Front Side Of 4 Garh Rif Under Ge (East) Lucknow

BOQ

Name of Work:- PROVN OF FLY PROOF DOOR WOODEN IN BLDG NO AL 77 78 AND 79 OF OTM ACCN AT 4 GARH RIF AND PROVN OF TWO WHEELER PARKING SHED AT RA BAZAR (FAFA JCOS) AND PROVN OF SHED AND INTERLOCKING TILING IN BUNGALOW NO P-5 BLDG NO 14 AT JOGGERS PARK AND PROVN OF CHAIN LINK FENCING BLDG NO AL-99 AND PROVN OF 01 X SHED FOR NEW RELIGIOUS HALL AT FRONT SIDE OF 4 GARH RIF UNDER GE (EAST) LUCKNOW
Sl. No. Item Description
1Surface excavation n.exe 30cm deep and averaging 15cm deep and getting out in soft/loose soil, complete all as specified and directed.
2Excavation in post holes (or similar holes) each not exc. 0.50 Cum, getting out, returning, filling and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm watering and removing surplus soil to a distance not exc. 50 m and making good surface as in soft / loose soil complete all as specified and directed.
3Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
4Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
5Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
6M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken bricks complete all as specified and directed.
7M & L for providing plain cement concrete, type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
8M & L for providing plain cement concrete, type B-2, 1:2:4 (using 40 mm graded stone aggregate) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed.
9M & L for providing plain cement concrete type B-0, 1:2:4, (using 12.5 mm graded stone aggregate), as in copings, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
10M & L for providing and laying at or near ground level factory made kerb stone/surface drain of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed
11M&L fly ash Brick work using old size bricks with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
12S & F of rolled mild steel sections as in main and cross beams, hip and jack rafter, purlins where connected to common rafters, running rails, guides for sliding doors fixed with angle cleat and other connecting plates conforming to Fe-410-W Grade E-250 complete all as specified and directed.
13S & F of mild steel work in hand rail, half round or other stock section or core for fixing of wooden hand rails, bluster, running bars, nosing of steps, wind ties, post and struts for fencing, flat iron fillets and the like including necessary cutting, drilling holes, notching etc. as required conforming to Fe-290 Grade E-165 complete all as specified and directed.
14S & F of steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS-1161(1979) grade St-240 complete all as specified and directed.
15S & F of mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe-290 Grade E-165 complete all as specified and directed.
16Supply only Chain link MS galvanisd fencing, any size or type made out of 3 mm dia GI wire to any type of standard, rails, straining bolts etc. complete all as specified and directed.
17Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed.
18S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
19S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
20M & L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and directed.
21All as per item No 20 above but on vertical surface over & including 10mm thick rendering in CM 1:4 complete all as speciified
22S & F of 18-20 mm thick granite (of any type and any shade) work (table rubbed and polished) for wall lining (veneering to wall) and the like, fixed over and including 10 mm thick cement plaster / screed in cement mortar 1:3 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab complete all as specified and directed.
23Rounding to edges of stone slabs one edge, such as in steps, cooking plateform incl making hole for gas pipe and other similar situation complete all as directed.
24M & L for providing 75mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor finished even and rough complete all as specified and directed.
25M & L for chequered cement concrete tiles 30cm x 30cm x25mm thick, set jointed and pointed in neat cement slurry, with mixture of white and grey cement in equal proportions and no pigments, laid over 15 mm thick screed bed in CM 1:6, floors, complete all as specified and directed.
26M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade With Grey Cement and pigment complete all as specified and directed.
27M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed
28M&L 15 mm thick rendering in CM 1:4 on external surfaces of walls, chajja, facia at any height with liquid water proofing compound, surface finished even and smooth without using extra cement.complete all as specified and directed.
29M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
30M & L preparation of new steel surfaces of any description exc 10 cm width or girth and applying two coat of Black Japan paint over a coat of red oxide primer complete all as specified and directed.
31S & F 1.5 mm thick powder coated aluminium partiton wall, partly panelled and partly glazed, size of aluminium section 44x44x1.5 mm th divided in square or rectangular (n exc 1.2 sqm each panel), top panel shall be glazed with 5.50 mm thick sheet glass any shade or tint / SS wire mesh with Aluminium Grill 75 x 75 mm size / 5 mm thick ACP sheet of any shade or colour as directed by Engr-in-Charge including necessary cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, with required EPDM rubber/ neoprene gasket complete all as specified.Note-The cost of glass, SS wire mesh and all above mentioned accessories also shall be deemed inclusive in quoted unit rate.
32M & L for premium wallpaper of 120-140 GSM of non woven material with adhesive with fire rating of ASTM Class A complete all as specified and directed.
33Taking down chowkhat with shutter (without taking off shutter from the frame) and area exc 1.5 sqm but n.exc 4 sqm each, complete, all as specified & directed.
34Taking down chowkhat with shutter (without taking off shutter from the frame) and area n.exc 1.50 sqm each, complete, all as specified & directed.
35S&F Pressed steel frames size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. incl filling cement concrete type B-1 (1:3:6) filling and compaction in frame complete all as specified.
36M & L for providing, fabricating, supplying and fixing only by authorised applicator as approved factory made HDHMR (High Density High Moisture Resistant TESA)both side BSL (Metalic) door shutters of 30 mm / 32 mm thickness or as per project requirement, manufactured from exterior grade high-density fibre homogeneous board made from plantation timbers such as eucalyptus, processed through drum debarker system for removal of bark, mud, grit and inferior fibres and refined through Z-shifter to eliminate oversized fibres and glue lumps; manufactured with homogeneous core (without layers) using advanced mat forming technology, bonded with in-house prepared synthetic resin and continuously hot pressed through 192-cylinder European press system ensuring multi-point pressure and temperature control for uniform density profile across length and width; having uniform density not less than 850 kg/m³ (±5%) ensuring high screw holding strength and structural stability; resin blended through European blow line technology for uniform fibre–resin distribution, equipped with online blow detector and online thickness calibration system for dimensional accuracy; termite and borer resistant, exterior grade high moisture resistant, suitable for routing and CNC machining; conforming to Grade–I of IS 12406:2003, ISI marked with Ecomark certification as per Ministry of Environment norms, IGBC compliant and FSC certified; factory calibrated and finished smooth for painting, polishing or other surface treatment, complete with cutting to size, edge finishing, necessary provisions for hardware and fixing in position including all labour, materials and incidental charges, complete as specified and directed by the Engineer-in-Charge.
37M & L for second class hardwood glazed and skeleton door shutters, 35mm thick, open rebated and prepared to receive glass, gauze, etc. (with sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beeds for securing glass etc.; and fitted to chowkats complete all as specified and directed.
38M & L for mild steel 300mm ordinary rat tail rod patttern springs includding roller and roller plate complete all as specified and directed.
39S&F Aluminium anodised barrel tower bolts of extruded section 200mm long complete all as specified and directed.
40M&L for 300mm aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts fixed complete all as specified and directed.
41S&F Aluminium handles cast type anodised of 150mm complete all as specified and directed.
42S&F 100 mm size Floor door stopper of aluminium alloy body and tongue, anodised, with rubber ends complete all as specified and directed.
43M&L preparing new untreated surfaces of wood and wood based materials of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer complete all as specified and directed.
44M & L for providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, Windows ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and directed.
45S & F 4.8mm thick sheet glass, ordinary quality and in square exc 0.5 sq.m in each pane in any position and complete all as specified and directed.
46S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or ss wire staples complete all as specified and directed.
47S&F for Powder coated Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws , including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed.
48Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
49M&L for Preparing of new plastered surface of wall and applying two coats of Oil emulsion distemper (OBD) of approved shade / tint over a coat of primer over a coat of min 1 mm thick putty complete all as specified and directed.
50Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over a coat of min 1 mm thick putty complete. Note- Primer and emmulsion to be carried out through air less spray machine (Mechanical means)
51M & L for Providing and applying minimum 1mm thick wall care putty over prepared surface to achive the surface even and smooth for painting complete all as specified and directed.
52M&L for Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core and removal of rubbish not exc. 50m complete all as specified and directed.
53M & L RCC type B-1 (1:2:4) using 20 mm graded stone aggregate on beams, cantilevers, lintel over 1.5 m Span complete all as specified and directed.
54M&L for TMT bars 10 mm dia and over for reinforcement cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, and binding with and incl MS wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-415 or Fe-500 complete all as specified and directed.
55M&L TMT bars of 6 to 8mm dia and over cut to lenth, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
56S & F of LED flood light 120 Watts, 230 V AC outdoor type with thermal management in multiple optics equipped IP 66 with impact and corrision resistant complete with driver and lamp aluminium die cast complete all as specified and directed.
57S & F aluminium conductor 10 Sqmm 2 core, heavy duty PVC sheated 1100 volts complete all as specified and directed.
58S&F of MCB Distribution Board, SPN 240 Volts, 4 way factory-assembled type, fabricated from powder-coated CRCA steel sheet, recess-mounted, complete with reversible double door, having a minimum degree of protection IP-43 and mechanical impact resistance IK-09, conforming to IS 61439 (Low-voltage switchgear and controlgear assemblies), provided with insulated tinned copper busbar of 100 Amp rating, separate neutral busbar and earth busbar, DIN rail, detachable gland plate, complete with all internal interconnections, earthing connections, and blanking plates for all unused ways/spaces complete all as specified and directed.
59Supply and fix in replacement of SP MCB 6 to 32 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10kA breaking capacity complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57251994
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 39.14 Lakhs
LAST DATE 19-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Fly Proof Door Wooden In Bldg No Al 77 78 And 79 Of Otm Accn At 4 Garh Rif And Provn Of Two Wheeler Parking Shed At Ra Bazar (Fafa Jcos) And Provn Of Shed And Interlocking Tiling In Bungalow No P-5 Bldg No 14 At Joggers Park And Provn Of Chain Link Fencing Bldg No Al-99 And Provn Of 01 X Shed For New Religious Hall At Front Side Of 4 Garh Rif Under Ge (East) Lucknow
Basic Detail
Tender No GE/E/LKO/T-67 OF 2026-27
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 29 Aug 2026
Submission Date 19 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 39.14 Lakhs
Tender Fee 500
EMD 78280
Exemption Available
Document List
5178128b-1b1f-4eb8-9f93-341aa016bbb8.html
BOQ_881881.xls
Tendernotice_1.pdf
TenderT67.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

5178128b-1b1f-4eb8-9f93-341aa016bbb8.html

xls

BOQ_881881.xls

pdf

Tendernotice_1.pdf

pdf

TenderT67.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders