Science and Technology Statutory Bodies & Commissions/Committees Closing in 16 days TDR #57250175

Tender For Ground Floor Raising Work At East Wing Neeri Unit In Csir C Us (Composite Work For Civil & Electrical).

Issued by Statutory Bodies & Commissions/Committees · Chennai, Tamil Nadu
Tender Value
19.40 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
16 days left
EMD
38800
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Ground Floor Raising Work At East Wing Neeri Unit In Csir C Us (Composite Work For Civil & Electrical).

BOQ

Name of Work:- Ground Floor Raising Work at East Wing NEERI Unit in CSIR C us (Composite work for Civil & Electrical).
Sl. No. Item Description
1Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
21:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources).
3REINFORCED CEMENT CONCRETE: Lintels, beams, plinth beams, girders, bressumers and cantilevers
4Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
5Thermo-Mechanically Treated bars of grade Fe-500D or more.
6Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using coarse aggregate as well as fine aggregate derived from natural sources and cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note:- Cement content considered in this item is @ 330 kg/cum.\\"Excess/ less cement used as per design mix is payable/recoverable separately).
7All works upto plinth level
8MASONRY WORK: Half brick masonary with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure above olinth level up to floor V level
9Cement morter 1:4 91 cement : 4 cparse sand)
10FLOORING: 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
11DISMANTLING AND DEMOLISHING : Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
12In cement mortar
13Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
14FINISHING : 12 mm cement plaster of mix :
151:4 (1 cement: 4 fine sand)
16Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
17Two coats
18Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
19With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
20Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
21Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
22White washing with lime to give an even shade :
23Old work (two or more coats)
24Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
25One or more coats on old work
26ALUMINIUM WORK : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
27Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
28Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
29For fixed portion
30Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
31Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain white color board for backing of cup boards and bathroom/kitchen cabinets etc. of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) &900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borerproof, water/moisture proof and fire retardant and fixing with stainless steel screws etc. all as per direction of Engineer-In Charge. (Note: stainless steel screws shall be paid separately)
3212 mm thick
33Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
34With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
35Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
36With stainless steel cover plate minimum 1.25 mm thickness
37Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
38Removing and refixing existing aluminium partition (frames, glass, boards, beading, sealant, etc.) without damage, stacking materials safely, and refixing in position with proper alignment, sealing joints, tightening screws, and cleaning, complete as directed by the Engineer-in-Charge.
39Checking, servicing, overhauling of steel casement windows (AGEW) / shutters for smooth operation the above rate does not include cost of any spare parts to be removed or replaced and the rate is only for servicing of the shutters)
40Filling in foundation and basement with crusher dust in layersnot exceeding 15 cm in depth each, including watering and throughly consolidating, etc., complete.
41Removing of wooden door frames and shutters to existing wall surface including replacement of bolts with screws, hold fast, lock and key facility etc. as required, all complete as per the direction of the Engineer-in-charge.
42Removing (Shifting) and Refixing Objects
43ElectricalWork: Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit,with modular switch,modular plate,suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc.as required.
44Group B
45Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
4615/16 A switch
476 pin 15/16 A socket outlet
48Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in Steel Structure with suitable clamping etc. as required.
496 Module
5012 Module
511 or 2 Module (75mmX75mm)
52Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
5332 mm
54Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.
552 Run of cable
56Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
573 x 2.5 sq. mm
583 x 4 sq. mm
593 x 6 sq. mm
606 x 6 sq. mm
61Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
622 X 10 sq. mm + 1 X 6 sq. mm earth wire
634 X 16 sq. mm + 2 X 6 sq. mm earth wire
64Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
65Brush Less Direct Current (BLDC) Fan with Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
661200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
67Supplying and fixing of 1 modular RJ 45 socket outlet with shutter in the existing Modular box, including connection ,testing as required as per site condition. Make:Legrand/Hager/Havells
68Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: Legrad/schinder/hager
69Single pole
70DP MCB
71TP MCB
72Supplying and fixing of following ways vertical type,415V,TPN MCCB distribution board of sheet steel,dust protected,duly powder painted,inclusive of 250A tinned copper bus bar, in steel structure surface with suitable fixing accessories or recess mounting, common neutral link,earth bar,din bar with provision for DPX 160 MCCB as incomer and SP/TP MCB's as outgoing mounting as required as per site condition. Make: Legrad/schinder/hager
7312 Way ,Double Door MCCB VTPN DB
74Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Legrad/schinder/hager
7512 Way ,SPNDouble Door DB
76SITC of 4 Pole,125A MCCB ,25KA,Thermal Magnetic protection unit in the existing MCCB DB including spredder for connection incoming and out going cables as reqired as per site condition.Make: Legrand ,Schinder and Hager.
77Supplying and fixing FP sheet steel enclosure on surface/ recess along with 32 A 415 V \\"C\\" curve FP MCB complete with connections, testing and commissioning etc. as required.Make: Legrand ,Schinder and Hager.
78Supplying and fixing DP sheet steel enclosure on surface/ recess along with 32 A 415 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.Make: Legrand ,Schinder and Hager.
79LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
80Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)
8140 watt
82Supplying and fixing of DLP PVC mini trucking system CMS 32 X 20 mm size without partition in the existing surface including suiatble fixing accessories, as required as per site condition. Make:Legrand
83Supplying and fixing of following size DLP PVC trucking system in the existing surface including suiatble fixing accessories, as required as per site condition. Make:Legrand
84105 x 50 MM DLP PVC trunking with flexible cover
85Separation partion for 105 x 50 MM DLP PVC Trunking system
86Cover joint for 85 mm
87Internal and External Angles 60 to 120 Degrees for 105 x 50 MM DLP PVC Trunking system
88End cap for 105 x 50 MM DLP PVC Trunking system
89Removing all the existing wiring,ceiling fans,tube light fittings (passage and rooms) , Power DBs and associated switchers in the existing surface(4 Rooms in NEERI Chemical room) and handed over to Enginner in charge.(Before quote te tender please visit the site) Note 1: The rates quoted for all items shall be incusive of Income Tax,GST TNCWW Cess etc.., as applicable. Note 2: SD @10% ,TNCWW Cess@1%, Income Tax 2% and TDS on GST 2% will be deducted from the bill. Note 3:The tenderers are requested to inspect the site and submit the tender before quoting. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57250175
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 19.40 Lakhs
LAST DATE 15-09-2026
Authority
Authority Name Council Of Scientific And Industrial Research
Work Description Tender for Ground Floor Raising Work At East Wing Neeri Unit In Csir C Us (Composite Work For Civil & Electrical).
Basic Detail
Tender No 476(2)734/2026-27/CW/EW
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 29 Aug 2026
Submission Date 15 Sep 2026
Open Date 16 Sep 2026
Finance
Tender Value 19.40 Lakhs
Tender Fee Ref. Documents
EMD 38800
Exemption Not Available
Document List
7bea565b-b9ff-4a60-aec6-1b190e0a07a2.html
BOQ_337405.xls
Tendernotice_1.pdf
Tendernotice_2 (2).pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Sep 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

7bea565b-b9ff-4a60-aec6-1b190e0a07a2.html

xls

BOQ_337405.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (2).pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender