Tender For Repairs / Maintenance Of Various Types Of Deep Freezer, Refrigerators At Certain Unit And Repair / Maintenance Of 3 X 30Tr Ac Plant, Cold Storage Plant, Split / Window Acs And Repair/Maint Of Water Supply Related And Electric Supply Of Var

Issued by Statutory Bodies & Commissions/Committees · Hyderabad, Telangana
Tender Value
41.50 Lakhs
Estimated cost
Bid Submission
19 Sep 2026
12 days left
EMD
83000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs / Maintenance Of Various Types Of Deep Freezer, Refrigerators At Certain Unit And Repair / Maintenance Of 3 X 30Tr Ac Plant, Cold Storage Plant, Split / Window Acs And Repair/Maint Of Water Supply Related And Electric Supply Of Various Types Of Related Items At Certain Unit Under Ge Golconda.

BOQ

Name of Work:- REPAIRS / MAINT OF VARIOUS TYPES OF DEEP FREEZER, REFRIGERATORS AT CERTAIN UNIT AND REPAIR / MAINTENANCE OF 3 X 30TR AC PLANT, COLD STORAGE PLANT, SPLIT / WINDOW ACs AND REPAIR/MAINT OF WATER SUPPLY RELATED AND ELECTRIC SUPPLY OF VARIOUS TYPES OF RELATED ITEMS AT CERTAIN UNIT UNDER GE GOLCONDA.
Sl. No. Item Description
1BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) File No 8156/E8 Tender Inviting Authority: GARRISON ENGINEER GOLCONDA Name of Work: REPAIRS / MAINT OF VARIOUS TYPES OF DEEP FREEZER, REFRIGERATORS AT CERTAIN UNIT AND REPAIR / MAINTENANCE OF 3 X 30TR AC PLANT, COLD STORAGE PLANT, SPLIT / WINDOW AC's AND REPAIR/MAINT OF WATER SUPPLY RELATED AND ELECTRIC SUPPLY OF VARIOUS TYPES OF RELATED ITEMS AT CERTAIN UNIT UNDER GE GOLCONDA. Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder including all TaxesRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES
2Taking out burnt / unserviceable compressor from existing Deep Freezer and S & F new sealed compressor unit including necessary welding/brazing/pressure testing with refrigerant after charging leak proof condition and testing complete for Deep freezers of any capacity complete all as specified and as directed.Note:- Rate quoted shall be inclusive of R-134a refrigerant gas charging, testing and commissioning.Make : Kirloskar/ Shriram/Voltas/Hitachi or techno commercially equivalent make as listed in list of makes as approved by GE.
3Taking out unserviceable deep freezer body complete including strainer with necessary brazing, Leak Testing suitable for Deep Freezer of existing capacity complete all as specified and as directed.
4S & Fix Over load protector complete suitable for Deep Freezer of any make/model of capacity 280/310 Ltrs including removal of old Unserviceable complete all as specified and as directed. Make : Shriram /Renutraul / Voltas or techno commercially equivalent make as listed in list of makes as approved by GE.
5S & Fix Thermostat set complete for Deep Freezer of any make/model of capacity 280/310 Ltrs including removing the old unserviceable complete all as specified and as directed. Make – Danfoss / Renutraul/Annapurna or techno commercially equivalent make as listed in list of makes as approved by GE.
6S & Fix Copper capillary tube including strainer with necessary brazing, Leak Testing suitable for Deep Freezer and taking out the old unserviceable one.
7Cleaning the gas system with CTC, rectification of leakages, M&L Charging gas with refrigerant gas including cutting/welding/brazing and leak testing with nitrogen, testing including commissioning complete for deep freezer 280/310 ltrs capacity complete all as specified and as directed.Note :- The rate towards Gas charging shall be included in the unit rate quoted.
8Taking out burnt / unserviceable compressor from existing refrigerator and S & F new sealed compressor unit including necessary welding/brazing/pressure testing with Nitrogen after charging leak proof condition and testing complete for refrigerator of 165 ltrs / 280 Ltrs capacity complete all as specified and as directed.. Note:- Rate quoted shall be inclusive of R-134a refrigerant gas charging, testing and commissioning complete all as specified and as directed. Make : kirloskar/Shriram/Voltas/OEM or techno commercially equivalent make as listed in list of makes as approved by GE.
9Taking out unserviceable refrigerator body complete capillary tube including strainer with necessary brazing, Leak Testing suitable for Refrigerators of existing capacity 165 to 310 Ltrs complete all as specified and as directed.
10S & F relay assembly and connecting with necessary wiring complete for Refrigerator of 165 to 286 ltrs capacity and taking down u/S one complete all as specified and as directed. Make:- LG/Godrej /Whrilfool or techno commercially equivalent make as listed in list of makes as approved by GE.
11S & Fix Thermostat set complete for Refrigerator of any make/model/capacity including removing the old unserviceable complete all as specified and as directed. Make – Danfoss / Renutraul/Annapurna or techno commercially equivalent make as listed in list of makes as approved by GE.
12S & Fix Over load protector complete suitable for Refrigerator of any make/ model of 165 to 310 Ltrs Capacity including removal of old Un Serviceable complete all as specified and as directed. :-Make : Shriram /Renutraul / Voltas or techno commercially equivalent make as listed in list of makes as approved by GE.
13S & Fix Copper capillary tube including strainer with necessary brazing, Leak Testing suitable for Refrigerators of capacity 165 to 310 Ltrs and taking out the old unserviceable one complete all as specified and as directed.
14Cleaning the gas system with CTC, rectification of leakages, M&L Charging gas with refrigerant gas including cutting/welding/brazing and leak testing with nitrogen, testing including commissioning complete for refrigerator 165 to 310 Ltrs capacity complete all as specified and as directed.Note :- Gas charging will be measured separately against relevant item of this schedule.
15S & Fix Connecting lead PVC sheathed 3 core copper wire cable, 4 sq mm 3 metre long with plug top 15 Amps for water cooler/Deep Freezer and taking out the old unserviceable one.
16S & Fix Magnetic door gasket for refrigerator of existing size and make including taking out the old gasket of refrigerator of capacity 165 to 310 Ltrs complete all as specified and as directed..
17Removing burnt out fan motor of frost free Refrigerator/deep freezer motor and refixing with new one complete all as specified and as directed.
18Removing the burnt out Glass Heater of frost free refrigerator and fixing with new one complete all as specified and as directed.
19S & Fix Refrigerator freezer box with door of capacity 165 Ltrs / 280 Ltrs including necessary welding/brazing/pressure testing with Nitrogen of any make and taking out the old unserviceable one complete all as specified and as directed.
20S & Fix Refrigerator door handles suitable for any capacity and any make and taking out the old unserviceable one complete all as specified and as directed.
21S & Fix Bi-metal fuse for refrigerator of any capacity and taking out the old unserviceable one complete all as specified and as directed.
22S & Fix Refrigerator timer for frost free refrigerator of any capacity and taking out the old unserviceable one complete all as specified and as directed..
23S & Fix Refrigerator condenser coil of 165 to 310 Ltrs capacity including necessary welding/brazing/pressure testing with Nitrogen Complete and taking out the old unserviceable one complete all as specified and as directed.
24Supply & charge refrigerant gas R-22 up to required level complete all as specified and directed.
25Supply & charge refrigerant gas R-134a up to required level complete all as specified and directed.
26S & Fix in replacement of old unserviceable fan motor with new fan motors of desert coolers of 4000/5000 Cum capacity with nuts, bolts, brackets, connecting arrangements reconnecting including removing of the old unserviceable and testing complete all as specified and as directed. Make: OEM
27Cold storage Room: Supply and fixing semi sealed compressor of package plant of ( 1.5X4 TR) capacity from its installed position by placing dummy plates to suction and discharge valves, opening of the compressor, removing of all the internal parts, cleaning of all parts thoroughly, overhauling of the compressor, replacing of worn out parts such as suction reeds, discharge reeds, piston rings, compression rings, connecting rods, bearings, piston pins, springs, spring washers, nuts, bolts, washers `O’ rings, gasket set etc. , reassembling of the all internal parts after replacing the worn out parts, rewinding of the compressor re-fixing back, removing of the dummy plate, oil charging and checking of oil pressure, vaccumising and leak testing and testing the compressor completely all as specified and directed.NOTE: The rate quoted shall deem to include for compressor oil, however refrigerant gas shall be measured and paid separately.
28Supply and fix AC contactor 32 Amps, 3 phase ,415 volts, 50 Hz suitable for cold storage complete all as specified and as directed.
29Cleaning of the evaporator coils of the capacities(1.5X4) TR with cleaning acid by forced feed method to remove the unwanted dust particles formed on the coil and fins, cleaning of the dust particles, parts of periodical maintenance, cleaning of liquid lines, strainer, expansion valve etc. and testing complete all as specified and directed.
30Supply and filling refrigerant gas-R22 all as specified and directed.
31Supply and fix cold storage room Temperature gauge as per sample complete and all as specified and directed.
32Supply and fix out door unit fan motor with blade water proof type suitable for cold storage unit all as specified and directed.
33Taking down carefully old burnt/unserviceable compressor unit of 1.0 ton capacity window type/Split type AC and replacing the same with New compressor including necessary accessories and mounting materials, welding, brazing, leak testing, vaccumising and charging the refrigerant gas to the required pressure and weight, reinstalling the AC unit on the same place including testing and commissioning complete to any make of AC complete all as specified and as directed. Note:- Rate quoted shall be inclusive of R-22 refrigerant gas charging, testing and commissioning.Make : Kirloskar / Voltas/ LG/OEM or techno commercially equivalent make as listed in list of makes as approved by GE.
34All as per item No : 32 above but for Window/Split type AC 1.50 Ton Capacity
35All as per item No : 32 above but for Window/Split type AC 2.00 Ton Capacity
36S & Fix Relay assembly and connecting with necessary wiring complete suitable for Window/Split type of AC 1.0/1.5/2.0 Ton Capacity and taking out the old unserviceable one complete all as specified and as directed.. Make : Shriram /Renutraul / Voltas or techno commercially equivalent make as listed in list of makes as approved by GE.
37S & Fix Over load protector complete suitable for Window/Split type AC of 1.0/105/2.0 Ton Capacity including removal of old unserviceable complete all as specified and as directed. :-Make : Shriram /Renutraul / Voltas or techno commercially equivalent make as listed in list of makes as approved by GE.
38S & Fix Thermostat set complete for window/split type AC of any make/model of Capacity 1.0/1.5/2.0 Ton including removing the old unserviceable complete all as specified and as directed. Make – Renutraul/Annapurna/Usha or techno commercially equivalent make as listed in list of makes as approved by GE.
39S & Fix Blower fan motor, with fixing arrangement complete operating on 215 / 240 Volts, single phase AC supply, multi speed suitable for Window AC 1/1.5/2.0 Ton capacity including taking out the old one complete all as specified and as directed.. Make : OEM
40Rewinding of outdoor fan motor with same guage and turns and weight of copper enamelled wire and replacement of bearing, testing and commissioning of 1.0/1.5/2.0 Ton split type AC of any make/ model complete all as specified and as directed.
41S & Fix capacitor of 36/45 MFD for Window/Split type AC's all as directed and taking out the old unserviceable one complete all as specified and as directed.. Make- CONCAP /BHEL/TIBCON or techno commercially equivalent make as listed in list of makes as approved by GE.
42S & Fix capacitor of 50/60 MFD for Window/Split type AC's all as directed and taking out the old unserviceable one complete all as specified and as directed.. Make- CONCAP /BHEL/TIBCON or techno commercially equivalent make as listed in list of makes as approved by GE.
43S & Fix Selector switch normal/Rotary complete for window type A/C 1 to 2 Ton capacity suitable for push button type including taking down the unserviceable one complete all as specified and as directed.
44S & Fix Copper capillary tube including strainer with necessary brazing, Leak Testing suitable for window /Split type AC 1 Ton to 2 Ton capacity and taking out the old unserviceable one complete all as specified and as directed..
45S & Fix Wiring kit for window type AC of 1.0/1.5/2.0 Ton capacity with copper wire PVC insulated single core of size1.5 sq. mm, clips, terminal connector etc. complete all as directed and taking out the old unserviceable one complete all as specified and as directed.
46Description same as per item No : 44 above but Split type AC of capacity 1.0/1.5/2.0 ton complete all as specified and as directed. .
47Cleaning the unit with CTC except evaporator and condenser and leak testing the system with Nitrogen gas and detecting the leak and repairing, brazing and sealing the leakage including charging the refrigerant R-22 gas to the required pressure and weight of gas for 1.0/1.5/2.0 Ton capacity window type AC of any make complete all as specified and as directed. Note :- Gas charging will be measured separately against relevant item of this schedule.
48Description same as per item No : 46 above but Split type AC of capacity 1.0/1.5/2.0 ton complete all as specified and as directed..
49Servicing to the split type AC units of 1/1.5/2.0 ton capacity, cleaning of the evaporator coils externally with Caustic Soda / Chemical to remove the dust particles deposited on the cooling coil, cleaning of the condensing units to reduce the discharge pressure with the Caustic Soda / Chemical and testing complete all as specified and as directed..
50Servicing to the window type Air Conditioners of capacity 1/1.5/2.0 ton capacity, cleaning of the evaporator coil externally with Caustic Soda / chemical to remove the dust particles, cleaning of the filters and testing complete all as specified and as directed..
51S & Fix Air Filter to the window /Split type Air Conditioners of 1/1.5 /2.0 Ton capacity and taking out the old unserviceable one complete all as specified and as directed.
52S & Fix Evaporator coil, including connected brazing welding work and provn of refrigerant suction/discharge line suitable for Window Ac / Split Type Ac 1.0/1.5 / 2.0 TR capacity including removing the unserviceable evaporator coil from the existing position complete all as specified and as directed.
53S & Fix new remote control assembly for split type AC 1.5 /2.0 TR capacity including removing of the old unserviceable complete all as specified and as directed.
54Taking out the unserviceable condenser coil and S & F new condenser coil made out of 25 SWG copper tubing having 30/34G aluminium fins per CM length for window AC/Split type AC 's of 1.5 Ton capacity all as directed including taking down old unserviceable condenser coil complete all as specified and as directed..
55S & Fix Front grill for Window AC as existing make/model and taking out the old unserviceable one complete all as specified and as directed..
56S & Fix indoor blower motor for split type AC of capacity 1.5/2.0 Ton as per existing model complete all as directed and taking out the old unserviceable one complete all as specified and as directed. Make : OEM
57S & Fix PVC drain pipe 25 mm for rectifying water leakage from AC units complete all as directed and taking out the old unserviceable one complete all as specified and as directed.
58S & Fix copper tube of size 3/8, 5/8 inch dia including necessary soldering , flooring and connecting and testing in between indoor to out door units of split type AC 1.5/2.0 Ton complete all as directed and taking out the old unserviceable one complete all as specified and as directed.
59Description all as per Item No 57 above but size of copper tubing 1/2, 1/4 inch dia complete all as specified and as directed.
60S & Fix insulation felt for split type AC 1.5 / 2.0 Ton copper tube inlet/outlet to out door unit up to 3 mtr in length complete all as specified and as directed.
61Taking out unserviceable 1 Pole contactor from split AC and replacing the same with new contactor suitable for 240V,50Hz coil complete all as directed and taking out the old unserviceable one complete all as specified and as directed.
62S & Fix Oscillation motor for the indoor unit of the split type AC of 1.5/2.0 Ton capacity complete all as directed and taking out the old unserviceable one complete all as specified and as directed.
63Taking out unserviceable dummy nuts from the split AC units and S & Fix new Brass Dummy / Flare nuts of existing size complete all as directed and taking out the old unserviceable one complete all as specified and as directed.
64S & Fix Fan blade for 1.5/2 Ton capacity window/Split type ACs as per existing size/ model complete all as directed and taking out the old unserviceable one complete all as specified and as directed..
65Taking down unserviceable Indoor unit of Split type AC of 1.5 TR capacity any make, model and S & F new indoor unit of same capacity suitable to existing Outdoor Unit including the necessary connections and testing complete all as specified and as directed. Make : OEM
66Taking down unserviceable outdoor unit of Split type AC of 1.5 TR capacity any make, model and S & F new outdoor unit of same capacity suitable to existing indoor Unit including the necessary connections and testing complete all as specified and as directed. Make : OEM
67Repairs to PCB of split type AC 1.5 /2.0 TR capacity including of replacement of electronic spares complete all as specified and as directed.
68AC PLANT: Leak testing of the system of the central A/C plant system of the following capacities with nitrogen (N2) pressure after evacuating of the existing refrigerant gas into the empty cylinders by separating the entire system such as compressor, condenser, refrigerant lines, evaporator etc., rectifying of the same by replacing the ‘O’ rings / teflon washers of suction / discharge / service valves, replacing the flair nuts etc., evacuating of the nitrogen from the system, vacuuming, recharging of taken out the refrigerant gas a for the capacities 34 TR complete all as specified and as directed.
69Disconnecting electrically and mechanically of the mono-block pump set of 3 to 5 HP capacity from the existing position by arranging dummy plates to suction and delivery line, removing from the existing position overhauling of the same, cleaning of the impeller, replacing the worn-out bearing, gland bush, gland nut, gland rope, greasing, re-fixing back and testing complete all as specified and as directed.
70All as per item No.68 above but rewinding, condenser fan varnishing, insulation, greasing , the mono-block pump set of 3 to 5 HP capacity except replacing of bearing complete all as specified and as directed.
71Descaling of condenser of the capacities-34 TR by circulating descaling agent HCL through the condenser by forced feed method, removing the end covers of condensers, cleaning the each tube of condenser thoroughly by brushing, re-fixing back the end covers of the condenser by replacing the rubber gasket, nut, bolts, washers, cleaning of spares nozzles cooling tower, sump, water line, strainer and testing for normal working pressure complete all as specified and directed.NOTE: After descaling the HP of the system should not be more than 200 psi, other wise descaling shall be again carried out with out any extra cost
72Supply and fix Voltmeter 0 – 500 Volts capacity by disconnecting the electric connections and removing burnt out / unserviceable voltmeter 0 – 500 Volts, including reconnecting and testing complete all as specified and as directed.
73Supply and fix Ammeter 0 – 100 Amps capacity by disconnecting the electric connections and removing burnt out / unserviceable Ammeter 0 –100 Amps, including reconnecting and testing complete all as specified and directed.
74Taking out unserviceable pressure gauge and supply and fix pressure gauge of 100/150 mm size or equivalent complete all as specified and as directed.
75Supply & Fixing the Temperature gauges in the chiller & AHU Water Pipe line complete with all accessories and as per sample complete all as specified and as directed.
76Supply & Fixing of Dual plate check Valve Of size 65 mm Dia in the chilled Water pump Discharge line With necessary Special Fitting and supports Complete with all accessories and as per sample complete all as specified and as directed.
77Supply & Fixing of Rubber Expansion joint for chillers and pump of Size 65MM Dia With Necessary Special Fitting and support complete with all accessories and as per sample complete all as specified and as directed.
78Removing unserviceable push button activator by disconnecting all the connections and supply and fix new push button activator, reconnecting and testing complete all as specified and directed.
79Supply, install , Testing and commissioning of 0.3 micron EU-14 HEPA Filters of outer size1220x610x150 mm with casing of aluminium foil and media made of submicron glass fiber paper flange type with grill made out of stainless steel perforated sheet 20 SWG under the filters and taking out the old unserviceable one complete all as specified and as directed.
80M & L for VOLTAS / OEM company authorized Service Engineer to rectify software problem / Reset / Programming of Chiller Unit of AC Plant of Capacity 35 TR complete all as specified and directed.
81Removing unserviceable selector switch and supply and fix selector switch of existing size complete all as specified and directed.
82Removing unserviceable temperature sensor and supply and fixing of temperature sensor of existing size complete all as specified and directed.
83Supply and fixing of 32 Amps power contactor of suitable size as per the existing sample for compressor all as specified and directed.
84Supply and fixing water flow switch as per sample all as specified and directed.
85Servicing of air cooled condenser with coil cleaning chemical complete all as specified and directed.
86Cleaning of water chiller by circulating of Concentrate HCL chemical complete all as specified and directed.
87Servicing of AHU including cleaning of coil cleaning chemical and cleaning of 10 micron filter and 5 micron filter complete all as specified and directed.
88Servicing of chiller pumps like greasing and replacing of gland rope minor consumable items complete all as specified and directed.
89Supply and fixing of MN25 contactor complete all as specified and as directed.
90Supply and fixing of catch all filter of suitable size for chiller complete all as specified and as directed.
91Supply and filling refrigerant gas A- 407 C complete all as specified and as directed.
92Removing of unserviceable/burnt out DOL starters by disconnecting all the cable connections connection supply and fix new DOL starter (MK-1) including reconnection and testing complete all as specified and directed.
93Supply and fix Indicating lamps (RYB) phase (Set of three) – 01 set complete all as specified and as directed.
94Supply and Fix Voltas scroll chiller 4.3 inch Touch DisplayHMI Standard 35 TR complete all as specified and as directed.Note for Items (i) AC Mechanic should note down complaints from Complaint Register or Instruction by JE / Phone and complaints shall be attended at various locations of MH MD, Asif nager, and Arty center areas which are 5 kms from complaint cell & complaint should be completed within 4 days. Major/Compressor replacement complaints with in 6 days. (ii) Old unserviceable compressors/motors will be handed over to contractor at the end of the Contract period by reshaping/ cutting them.(iii) AC Mechanic duties as measured in note (i) is deemed to be included in CA items.
95S&F galvanized steel water tubing medium grade of 15mm bore complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions including taking up or down existing steel tubing with fittings complete all as specified and as directed. Make : JINDAL/TATA/ZEENATH or techno commercially equivalent make as listed in list of makes as approved by GE.
96All as per item no.94 above but 20mm bore
97All as per item no.94 above but 25mm bore
98All as per item no.94 above but 40mm bore
99All as per item no.94 above but 50mm bore
100All as per item no. 94 above but 80mm bore
101All as per item no.94 above but 100mm bore
102S&F in repairs gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe of 15mm bore including taking down complete all as specified and directed. MAKE : LEADER/ZOLOTO or techno commercially equivalent make as listed in list of makes and as approved by GE.
103All as per item no.101 above but 20mm bore
104All as per item no.101 above but 25mm bore
105All as per item no.101 above but 40mm bore
106All as per item no.101 above but 50mm bore
107Supply and fixing new CI sluice valves PN 1.6 confirming to ISI with flanged ends, SS spindle, round wheel including jointing materials,PCC work, nuts, bolts and gasket including taking out the unserviceable cast iron sluice valve for size 100 mm bore complete all as specified and directed MAKE : DURGA/KIRLOSKER/LEADER or techno commercially equivalent make as listed in list of makes as approved by GE.
108Construction of valve chamber with PCC 1:4:8 type D2 for foundation, brick wall in cement mortar (1:4), PCC 1:2:4 type B1 for coping, rendering in CM (1:4) 15mm thick for internal surfaces, 3mm thick MS sheet welded to frame made out of 40 x 40 x 3 as cover (of suitable size wrt chamber size) fixed with hinges welded to frame of 50 x 50 x 6mm embedded in coping and applying two coats of synthetic enamel paint over a coat of red oxide primer to the steel surfaces including necessary excavation and earthwork in any type of soil complete for chamber of size 600x600x600mm complete all as specified and as directed.
109(a) All as per item No.107 above but 900x900x900mm depth
110Attending the water supply leakages complaints up to 50 mm GI pipes and repairing the pipe ,arrest the leakage of water complete all as specified and as directed. note - spare parts i.e. unions,bends,couplins,tees,elbows etc of up to 50 mm pipe and labour,excavation included rate quoted
111M&L for Attending emergency breakdown of water supply installations where directed, Lifting up defective submersible pump set of capacity up to 7.5HP, 3 phase/1 phase, 240/415 volts, any stage and deep, column pipes (any number) from bore well, setting aside and stacking column pipes for reuse, transporting unserviceable pumpset,column pipes from bore well to workshop Opening of the defective motor & pump in MES store yard/ workshop, cleaning the covers and parts as applicable in presence of Engineer in Charge to ascertain the quantum of defects and repairs involved and assembling the motor & pump after carrying out repair works to make smooth functioning, applying spray painting to the repaired motor& pump externally with two coats of synthetic enamel paint of shade as directed by the Engineer in Charge transporting repaired pump set from workshop to bore well site after completion of repair work, lowering of submersible pump set with column pipes in the bore well as existing with new nut bolt and washer including rubber gasket 3 mm thick, including electrical supply connections as per existing for smooth functioning of pump motors complete all as specified and directed.Note: Repair work of submersible pump set will measured and paid separately under respective items of this schedule.
112Supply only the following spares required against Sl. Item No. 110 where required for submersible pump set of capacity up to 7.5 HP as per the model and make complete all as specified and as directed :-(a) Water lubricant seal suitable for motor.
113All as per item no.111 above but Thrust bearing for pumps
114All as per item no.111 above but Bearing cover sleeve.
115All as per item no.111 above but Thrust bearing for motors
116All as per item no.111 above but Impeller fibre type
117All as per item no.111 above but Neck ring
118All as per item no.111 above but Stainless steel key for impeller shaft
119All as per item no.111 above but Stainless steel motor - pump shaft coupler
120All as per item no.111 above but Body bush for pump
121All as per item no.111 above but Stainless steel sleeve for pump shaft
122All as per item no.111 above but Pump shaft gun metal of appropriate size
123All as per item no.111 above but Thrust pad
124All as per item no.111 above but Rubber bushes to motor shaft.
125All as per item no.111 above but Thrust plate
126M&L Rewinding of stator of submersible motor of capacity up to 7.5HP with water proof insulated copper wire of existing gauge and size to achieve the specified / required RPM including taking out old unserviceable winding complete all as specified and directed.
127S&F single phase preventer including taking down existing single phase preventer complete all as specified and as directed.
128S&F steel water tubing, galvanized, heavy duty, 50 mm bore, column pipe, both ends threaded, including taking down existing pipe complete all as specified and as directed.
129Supply and fix GI socket, heavy duty, 100mm long, 50mm bore, complete all as specified and as directed.
130Cutting and threading the existing column pipe of 3m long, 50mm bore, after transporting to the work shop and getting threaded suitable for 100mm long, coupler and transporting back to site complete all as specified and as directed.
131Redevelopment of tube well of maximum depth of 100 mtr by means of pumping by Air compressor of minimum pressure 10 Kg/cm2 (compressor to be arranged by contractor at his own cost), until sand free and clean water is obtained complete all as specified and directed.
132Supply, laying and testing PVC insulated and sheathed flat 3 core 6 Sqmm, copper stranded conductor water proof submersible cable fixed to submersible monoblock pump set to starter, complete, including taking out old unserviceable cable of any description complete all as specified and as directed.
133Supply, Laying, testing & commissioning XLPE insulated, PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable 3.5 Core 35 Sqmm with stranded aluminium conductor in trenches/ fixed to walls/ poles etc. including taking out of existing cable complete all as specified and directed.
134Supply, Laying, testing & commissioning XLPE insulated, PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable 3.5 Core 50 Sqmm with stranded aluminium conductor in trenches/ fixed to walls/ poles etc. including taking out of existing cable complete all as specified and directed.
135Supply, Laying, testing & commissioning XLPE insulated, PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable 3.5 Core 95 Sqmm with stranded aluminium conductor in trenches/ fixed to walls/ poles etc. including taking out of existing cable complete all as specified and directed.
136Supply, Laying, testing & commissioning XLPE insulated, PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable 3.5 Core 185 Sqmm with stranded aluminium conductor in trenches/ fixed to walls/ poles etc. including taking out of existing cable complete all as specified and directed.
137S&L XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured ,electric power cables heavy duty with aluminium conductor, 11000 Volts grade ( earthed) of size 3 core 95 Sqmm complete in trenches/ ducts/ on pole etc. complete all as specified and as directed. Note for item 132 to 136 Earth work & excavation, sand cushioning and brick protection shall be measured and paid separately.
138M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 50 to 95 Sqmm including testing after jointing complete all as specified and as directed.
139S&F GOD switches air break gang operated, triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level, for current rating up to 400 Amps complete all as specified and as directed.
140Supply & Laying 100 mm bore GI tubing, light grade, with all fittings of following sizes for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed.
141Supply & Laying 80 mm bore GI tubing, light grade, with all fittings of following sizes for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed.
142Supply & Laying 50 mm bore GI tubing, light grade, with all fittings of following sizes for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed.
143S & F cable end termination jointing kit heat shrinkable type for 1.1 KV (earthed) grade cable for outdoor with jointing material and accessories suitable for 3.5 core of size 35 sqmm to 70 Sqmm complete including taking out old unserviceable end termination jointing kit complete all as specified and directed.
144S & F cable end termination jointing kit heat shrinkable type for 1.1 KV (earthed) grade cable for outdoor with jointing material and accessories suitable for 3.5 core of size 95 sqmm to 150 Sqmm complete including taking out old unserviceable end termination jointing kit complete all as specified and directed.
145S & F cable end termination jointing kit heat shrinkable type for 1.1 KV (earthed) grade cable for outdoor with jointing material and accessories suitable for 3.5 core of size 185 sqmm to 240 Sqmm complete including taking out old unserviceable end termination jointing kit complete all as specified and directed.
146S and F cable jointing kit, outdoor heat shrinkable type straight through joint for 1.1 KV (Earthed) grade cable with jointing material and accessories suitable for cable of size 3.5 core 35 to 70 Sqmm including taking out old unserviceable joint kit straight through type complete all as specified and directed.
147S and F cable jointing kit, outdoor heat shrinkable type straight through joint for 1.1 KV (Earthed) grade cable with jointing material and accessories suitable for cable of size 3.5 core 95 to 150 Sqmm including taking out old unserviceable joint kit straight through type complete all as specified and directed.
148S and F cable jointing kit, outdoor heat shrinkable type straight through joint for 1.1 KV (Earthed) grade cable with jointing material and accessories suitable for cable of size 3.5 core 180 to 240 Sqmm including taking out old unserviceable joint kit straight through type complete all as specified and directed.
149Supply, Fixing and stringing ACSR Conductor steel reinforced of type as directed including stretching, binding using ACSR conductor on insulator on overhead line including taking down of existing conductor complete all as specified and directed.
150Stringing only ACSR Conductor of type as directed including binding using ACSR conductor on insulator on overhead line, complete all as specified and directed.
151M&L Mild steel Cross arm bracing support clamps and back plates fabricated from structural steel sections including nuts, bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or sizes as indicated or directed inclusive of one coat of red oxide zinc chrome primer and two coats of aluminium paint and removing the existing cross arms etc. complete all as specified and directed.
152M&L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut,100mm height, 65mm dia for 1100 Volts grade, including taking down existing insulator complete all as specified and directed.
153M&L Shakle type, porcelain, vitreous, white brown or green insulator including galvanized mild steel straps, washers, insulator bolts, washers and nuts 100mm in height, 115mm dia, working pressure 1100 volts, section of strap 31X5, 14mm dia bolts including taking down the existing insulator complete all as specified and directed.
154S&F Stay assembly complete with accessories as shown in electric plate No.1, stay rod 16mm dia, loop type insulator, stay clamps including excavation and earth work, PCC foundation etc., and taking out old unserviceable stay assembly complete all as specified and directed.
155Cutting & trimming of tree branches any girth and size touching to overhead lines and cleaning the distance 1.5 mtr both sides of overhead line with in a gap of span 40 mtrs each and removing the same cleaning the site complete all as specified and as directed.
156Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for foundation, laying of poles, cables in trenches and getting out in hard/dense soil complete all as directed and specified.
157Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed.
158Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed.
159Supply and spread approved dry river sand for cushioning of cable including watering and consolidation, laid in trenches complete all as specified and directed. Note:- Punned thickness shall be measured for payment purpose
160M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 113 x 75mm for cable protection complete all as specified and directed.
161M & L for cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and moorum filling including excavation for laying of cable/pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc., required to match with the existing surface complete all as specified and directed.
162S&F PVC separators suitable for LT over head line of 4 conductors complete all as specified and as directed.
163M&L for cleaning thoroughly LT distribution steel poles of any height and any description (Maximum 9 Mtr long) with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping complete all as specified and directed .
164M&L for cleaning thoroughly the two pole structure of any height and any description with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping , complete all as specified and directed .
165M&L for cleaning thoroughly the four pole structure of any height and any description with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping , complete all as specified and directed .
166Supply, install, test and commission CPRI APPROVED factory fabricated, outdoor type, LT FEEDER PILLAR BOX made out of 3.15mm thick CRCA sheet of size 1M x 0.75M x 0.35M with projected globe roof for rainwater protection dust and vermin proof, double door with both side opening including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 Wire System, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc. and embedded with 50x50x6mm MS angle iron frame, 600mm above the normal ground level complete with internal connection with suitable size of cable, cable lugs and cable glands, PCC foundation in cement concrete 1:3:6 (20mm graded stone aggregate) complete all as specified and directed and comprising of the following :-(a) Aluminium busbar 200 amps - 04 Nos, supported on suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.(b) MCCB 125 amps, 415 volt, 16 KA breaking capacity 4 pole electromagnetic release duly connected to busbar as incoming - 01 No.
167S&F in repair galvanized iron strip of size 25x4mm complete all as specified and directed.
168S&F, in repair, SS Enclosure with frame cubical type wall mounted front operated on-load changeover switch of capacity 400 Amps 415 volts, 4 pole including necessary electric connection with suitable size aluminium lugs complete all as specified and directed.
169M&L for repair of existing LT panel outdoor/indoor type by properly fixing loose/dislocated MS doors complete with provision of hinges and welding at locations as necessary, provision of tower bolt as per as existing size including painting of internal and external surfaces with one coat of synthetic enamel paint of approved colour after preparation of old painted surfaces complete as required for smooth operation of panel and complete all as specified and as directed.(Size of Panel board n.exc 2.25x1.2x0.6 m) NOTE: Cost of MS sheet, Tower bolt, sliding bolt as required shall be included in the unit rate quoted by the Contractor.
170M&L Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 32 x 6 mm by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point including necessary earth work and excavation, PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with GI pipe 15mm dia medium grade and protection pipe GI 40 mm dia light grade complete all as specified and as directed.Note: Earth strip and protection pipe beyond 7.5m shall be measured and paid separately.
171Disconnecting existing panel and its connections and supply, install, testing and commissioning CPRI APPROVED factory fabricated powder coated, outdoor type, LT FEEDER PANEL of 300 Amps made out of 3.15mm thick CRCA sheet of suitable size with projected globe roof for rainwater protection dust and vermin proof, double door (including locking arrangement) with both side opening including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 Wire System, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc. with panel control copper wiring, accessories fitted on suitable insulator all housed in suitable size chamber and fixing of digital Voltmeter, Ammeter with built in selector switch, CT's of suitable ratio, pilot indication lamps including internal connection with suitable size of cable, cable lugs and cable glands, panel embedded with 50x50x6mm mild steel angle iron frame 600mm above the normal ground level complete, PCC foundation 1:4:8 (using 40mm graded stone aggregate) and testing after installation complete all as specified and comprising of the following :-(a) Aluminium busbar 800 amps size 50mm x 10mm - 04 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.(b) MCCB 400 amps, 415 volt, 50 KA breaking capacity 4 pole - 01 Nos ( as incoming)(c) MCCB 250 amps, 415 volt, 36 KA breaking capacity 4 pole - 02 Nos( as outgoing) (c) MCCB 4 pole 160Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals -02 Nos(d) Three phase panel mounted digital type voltmeter 0-500 volts, selector switch and Ammeter 0-500 Amps with selector switch and LT-CT operated complete - 01 Set(e) Phase indicating lamp LED type for Red, Yellow and Blue - 01 Set
172Providing and constructing complete civil works for transformer foundation and plinth protection including all labour, materials, tools and plants, transportation and incidental works complete as per approved drawings and specifications. The work includes site clearance, removal of vegetation, loose soil, debris and dressing of ground to required levels; excavation of soil in all types of strata including hard soil if encountered, trimming of sides and bottoms, dewatering wherever required, and disposal of surplus excavated earth within specified lead and lift as directed by the Engineer-in-Charge. Providing and laying lean concrete/PCC bed of required thickness and grade (1:4:8 or 1:3:6 as specified) for foundation base, including proper compaction, levelling and curing. Providing and constructing RCC foundation blocks or pedestals of required size and grade (minimum M20 or as specified) for supporting transformer base, including centering, shuttering, reinforcement steel fabrication, bending, binding, placing, vibration, finishing and curing as per standard construction practice and approved drawings. Providing anchor bolts, base frame fixing arrangements or embedded steel components wherever required for proper seating and stability of transformer structure, including alignment and levelling to required tolerance. Providing and laying 1200 mm wide plinth protection around 3.0 m × 3.0 m transformer plinth including preparation and compaction of subgrade, laying 75 mm thick compacted dry brick aggregate/stone ballast layer of approved quality, and providing 50 mm thick Plain Cement Concrete (PCC) in proportion 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate of 20 mm nominal size), finished with uniform outward slope of minimum 1 in 50 for effective drainage away from the transformer foundation, including providing brick edging in cement mortar 1:4 along outer boundary with proper alignment, jointing, finishing and curing. The work shall include all materials such as cement, sand, aggregates, steel reinforcement, bricks, water, formwork materials, anchor bolts, consumables; labour including skilled and unskilled manpower; tools and plants; mixing, placing and compaction equipment; transportation, loading, unloading, handling, wastage, royalties, taxes, contractor’s overheads and profit; safety measures and all incidental works required for complete execution. The work shall be executed strictly in accordance with approved drawings, relevant IS codes and directions of the Engineer-in-Charge. The item shall be measured and paid as one complete job upon satisfactory completion of transformer foundation and plinth protection works in all respects.
173Supply, transportation, loading, unloading, erection, testing and commissioning of one complete Distribution Transformer Centre on Two Pole Structure, including supply of two Nos. 11 m long PCC/PSC poles of approved specification, excavation of pole pits in all types of soil, erection, alignment, plumbing and setting of poles, backfilling and compaction of excavated earth, providing and laying cement concrete for pole foundations wherever required, supply and erection of hot-dip galvanized MS channels, transformer mounting channels, cross-arms, bracings, clamps, gussets, base plates, nuts, bolts and washers complete.The work shall include supply and fixing of HT cross-arms, LT cross-arms, anti-climbing devices, danger plates, phase identification plates, number plates, stay sets complete with stay rods, stay wire, turn buckles, strain insulators and anchor blocks, all structural accessories, fabrication, drilling, cutting, welding, galvanizing and erection works as required. The item shall include transportation of all materials from approved source/store to work site, loading, unloading, stacking, handling, labour charges, tools and plants, lifting equipment, scaffolding, consumables, testing, commissioning, touch-up painting of damaged galvanized surfaces, site clearance and all incidental works necessary for complete erection of the two pole structure ready for installation of transformer, complete in all respects as per approved drawings, relevant IS specifications, utility standards and directions of the Engineer-in-Charge. The item shall be measured and paid as one complete structure/job
174Shifting of transformer from one place to another place by using of Hydra /Crane or other transport etc. to a distance not more than 5 Km and placing in/over platform/foundation of Transformer complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57249659
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 41.50 Lakhs
LAST DATE 19-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs / Maintenance Of Various Types Of Deep Freezer, Refrigerators At Certain Unit And Repair / Maintenance Of 3 X 30Tr Ac Plant, Cold Storage Plant, Split / Window Acs And Repair/Maint Of Water Supply Related And Electric Supply Of Various Types Of Related Items At Certain Unit Under Ge Golconda.
Basic Detail
Tender No 8156/E8
Bidding Type Tender
Location
City Hyderabad
State Telangana
Key Dates
Publish Date 29 Aug 2026
Submission Date 19 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value 41.50 Lakhs
Tender Fee 500
EMD 83000
Exemption Available
Document List
5e756a7d-5220-4e87-bb49-8e8084df96c4.html
8156NIT.pdf
8156Tender.pdf
BOQ_881733.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

5e756a7d-5220-4e87-bb49-8e8084df96c4.html

pdf

8156NIT.pdf

pdf

8156Tender.pdf

xls

BOQ_881733.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders