Tender For Special Repair To Certain Buildings At Sigar Mil Stn
Tender Value
29.98 Lakhs
Estimated cost
Bid Submission
18 Sep 2026
11 days left
EMD
59960
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
East Siang → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Certain Buildings At Sigar Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (unreinfoced) in ground floor,paving nexc 15mm thick(below or above GL) complete all as specified and directed |
| 2 | Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc. complete all as specified and as directed. |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. complete all as specified and as directed |
| 4 | M&L precast cement concrete block masonry with solid block, type C-1,1:3:6 mix ( using 20mm graded aggregate), exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 5 | M&L 25mm thick cement concrete as in Sub-base in cement concrete type B0 1:2:4 using 12.5mm graded stone aggregate as in floor, finished fair and even (toilet & bathroom sunken portion) or any where as required, complete all as specified and as directed. |
| 6 | S&F Non - skid coloured ceramic tiles of size 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, skirtings etc set and jointed in neat cement slurry and pointed in white or coloured cemert to match including screed bed or bedding layers of mortar 15mm thick for laying floor finishes in CM 1:4 complete all as specified and as directed. |
| 7 | M&L for 75mm thick plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified and directed . |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 9 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified & as directed. |
| 10 | S&F rolled mild steel plates ( plain or chequrred) channels, square cut or notched ( ordinary or counter sunk) forming holes, without any attachment complete all as specified & as directed. |
| 11 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, incl nanital or similar pattern roof covering.complete all as specified and as directed |
| 12 | S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 13 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/ridges/cladding to wall, fixed with self tapping screws/Aluminium screws complete all as specified and directed. |
| 14 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exc. 1.50sqm & not exc 4.00 sqm each and removing from site complete all as specified and directed. |
| 15 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) area not exc. 1.5 sq. m each each and removing from site complete all as specified and directed. |
| 16 | S&F 35mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type with both faces are covered with decorative face veneer with lipping/frame to match, all as specified & directed by Engr-in-Charge. |
| 17 | M&L mild steel work in framed work to Door Chowkats (angle in any section as desired),grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors and similar work conforming to Fe 290 Gde E-165.complete all as specified and as directed |
| 18 | S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates, shutters etc including joining cleat for fixing etc. complete all as specified |
| 19 | S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, side locks etc. complete all as specified & directed. |
| 20 | S&F of 4.00mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as directed. |
| 21 | S&F 300mm size MS Door spring including roller and roller plate by means of welding or screwing down. complete all as specified and as directed |
| 22 | S&F aluminium handles, cast type, anodised of size 150 mm all as specified & directed. |
| 23 | S&F Aluminium anodised, barrel tower bolts of extruded section 150mm long complete all as specified and directed . |
| 24 | S&F aluminium alloy, anodised, sliding door bolt 150mm long with hasp, stapple (bolt type) and fixing clips of sheet, cast or extruded sections complete all as specified and directed . |
| 25 | S&F 125mm size, mild steel butt hinges, medium weight cold rolled complete all as specified and as directed. |
| 26 | M&L for applying two coats of synthetic enamel paint over a coat of pink primer on new or previously untreated wooden surfaces exc 10cm girth or girth incl preparation of new wooden surfaces complete all as specified and directed. |
| 27 | M&Lpreparation of old surface of steel and iron work of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint existing pattern (Ordinary tint) complete all as specified & as directed. |
| 28 | M&Lpreparation of new surface of steel and iron work of any description, not otherwise described, not exceeding 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide primer complete all as specified & as directed. |
| 29 | S&F in repair Stainless Steel Curtain Rail/ Rod having 24mm Outer dia and 1.0mm Wall thickness including Brackets, Side Holders and Rings, etc. and Fixed-in-repairs, complete all as specified and as directed.NOTE :- (a) Stainless Steel Decorative Finials and Stainless Steel Brackets will be provided for Each Length of Curtain Rail/ Rod and Cost of the same will deemed to be included in the Quoted Unit Rate.(b) Only Length of Curtain Rail/ Rod will be Measured for Payment. |
| 30 | S&F-in-repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as dpecified and as directed. |
| 31 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets. complete all as specified and as directed |
| 32 | M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Alumi nium framework with screws and S & F of Anodised aluminium snap grid frame work of size 605 x 605 mm in Ceiling, all as per specification and drawing of MES Schedule for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specifiedall as specified |
| 33 | M&L cement concrete chequrred tiles of size 20cmx20cmx25mm thick machine pressed , set and jointed and pointed in neat cement slurry with white and grey cement in equal proportion and no pigments including 15mm thick screed bed in CM 1:4 over 50mm thick cement concrete type B-2 (1:2:4 ) 40mm graded aggregate in sub base complete all as specified and directed |
| 34 | S & F 600x450 mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building Board or Commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as directed. |
| 35 | Taking down cement or cement lime plaster of any discription on bricks or stone walls/ceiling etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 36 | M&L rendering 20mm thick on brick wall or concrete surfaces in cm 1:4, by finishing fair and even complete all as specified and as directed |
| 37 | M&L for preparation of new plastered surfaces of wall and appling two coats cement base paint overa coat of white wash complete all as specified and as directed |
| 38 | M &L for preparing old previously treated Asbestos cement plaster surface in wall (any type) of any description not other wise described over 10 cm in width or girth and applying one coat of synthetic enamel paint in existing pattern complete all as specified and directed. |
| 39 | Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified & directed. |
| 40 | Taking down the existing unserviceable main switches, DBs,bus bar chambers,VTPN etc of any capacityincluding all fitting and fixtures such as MCBs,isolatorr etc and removing from site complete all as specified and as directed. |
| 41 | M&L for Point wiring for One light point controlled by one way switch with two runs 1.5 Sq mm copper conductor single core FRLS (ISI Marked) PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC caping and casing of suitable size surface type and all fittings/fixtures such as TEE,Bend,elbow,socket,shadle etc of suitable size ISI marked and PVC terminal boxes of suitable size for mounting the switches/sockets/regulators/ceiling rose etc including running up of 1.5 Sq mm copper conductor FRLS (ISI marked) PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified .(Note-Rate quoted is deemed to include making good the disturbed surface and to match the adjoining surface) |
| 42 | All as per Item No 41.00 above but for exhaust fan point wiring |
| 43 | All as per Item No 41.00 above butfor ceiling fan point wiring |
| 44 | All as per Item No 41.00 above but One 3 pin socket outlet, 5 Amps, same board, with cables 1.5 sq. mm size. |
| 45 | All as per Item No. 41.00 above but One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size. |
| 46 | All as per Item No. 41.00 above but using 2.5 sq mm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 3/6 pin socket outlet 15 Amps ,on Independent board |
| 47 | S&F switch piano, flush type, single pole one way 6 Amp 1-way,23 Volt AC and connecting up complete all as specified and directed. |
| 48 | S&F Socket outlet multi-plug, 5 pin, 6 Amps flush type universal complete all as specified and directed. |
| 49 | S&F switch socket combination 6 Amp,5 pin,multi plug,flush type AC, complete all as specified and directed. |
| 50 | S&F switch socket combination 6/16 Amp, 2 in 1, 3 pin,multi plug,flush type AC, complete all as specified and directed. |
| 51 | S&F Ceiling Rose,65 x50mm, surface bakelite suitable suitable for 230 Volt AC and connecting up, 3 terminal complete all as specified and directed. |
| 52 | S&F ceiling fan regulator 230 Volt AC, electronic rotary stepped type complete all as specified and directed. |
| 53 | S&F LED Tube Light Fitting 1 x 20 Watt, 220 Volts, AC decorative box type with driver, holder incl LED tube light connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 54 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 55 | S&F LED light fitting 1x10 Watt Bulkhead luminaires IP 65 rated with pressure die cast aluminium housing and acrylic diffuser,CCT:WW/NW/CW,CRI>80 Ra with open and short circuit protections as per IS :10322 with all accessories including lamp connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 56 | S & F Angle holder,PVC/Polycarbonate type with back plate including LED bulb,15 Watt,B-22 lumen greaten than 900, CCT:WW/NW/CW,CRI>80 Ra over moulded plastic housing,polycarbonate diffuser,4Kv surge protection with over voltage withstand up to 440V(for 10 Minutes) with open and short circuit protection as per IS:1602 complete all as specified and directed. Please Enable Macros to View BoQ information |
| 57 | S & F Angle holder,PVC/Polycarbonate type with back plate including LED bulb,15 Watt,B-22 lumen greaten than 900, CCT:WW/NW/CW,CRI>80 Ra over moulded plastic housing,polycarbonate diffuser,4Kv surge protection with over voltage withstand up to 440V(for 10 Minutes) with open and short circuit protection as per IS:1602 complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysSep 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender