Public Administrative Department Local Bodies Closing in 3 days TDR #57247832

Tender For Renovation Of Upgradation High School Sangr Ur ,Block - Gola, Ramgarh

Issued by Local Bodies · Ramgarh, Jharkhand
Tender Value
94.48 Lakhs
Estimated cost
Bid Submission
03 Sep 2026
3 days left
EMD
1.89 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ramgarh → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Of Upgradation High School Sangr Ur ,Block - Gola, Ramgarh

BOQ

Name of Work:- RENOVATION OF UPG HIGH SCHOOL SANGR UR ,BLOCK - GOLA, RAMGARH
Sl. No. Item Description
1CIVIL WORKS
2Dismantling old plaster and pointing in cement or lime and raking out joints to 15 mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/l.
3Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
4Providing 12 mm thick cement plaster (1:6)with clean coarse sand of F.M 1.5--do- -do--complete job.
5Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
6Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
7Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
8Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.)
9Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification)
10Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
11Providing and laying 1mm thick white cement based wall putty--do--do--complete.
12Providing two coats of oil bound distemper of approved shade and make over old Surface-do-.
13Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding , curing and taxes all complete as per building specification and direction of E/I.
14Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
151:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mmnominal size)
16Labour for scrapping old paint with paint remover and below lamp as required on wooden or steel surface including cost of all labour and materials and scaffolding all complete as per building specification and direction of E/I.
17Providing 50mm thick 2nd class patent stone flooring (1:2:4) in floor……..do…do
18Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I.
19Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced……membrane: 3mm Thick
20Lettering with black Japan paint of approved brand and manufacture ( Writing Name of School)
21Carraige of Materials:-
22(A) Sand - (1+9) km
23(B) S/Chips - (1+19) km
24Wiring for light point/ fan point/exhaust fan point / call bell point with 1.5 sq.mm FR PVC Modular type GROUP - C
25Wiring for light/power plug with 2x 4 sq.mm FR PVC insulated, copper conductor
26Circuit/submain wiring in PVC conduit
272X2.5 sq mm +1 x 2.5sq mm earth wire
282X4sq mm +1 x 4sq mm earth wire .
29Supplying and fixing of following way single pole & neutral, sheet steel , MCB distribution
3012way SPN double door.
31Supplying and fixing 5 amps to 32 amps, rating, 240 volts, 'B' series
326/32amp Single pole
33Supplying and fixing 5 amps to 32 amps, rating, 240 volts, 'C' series, maniature circuit
346/32amp SPN
35Supplying and Fixing following size/modules, GI box along with modular base,cover plate….etc as required.
36S/F ceiling rose including connection etc.as reqd.
37S/F brass battan / angle holder including connection etc.as reqd.
38Supplying and fixing following Modular type
395/6 amps switch
405/6 amps socket outlet
41Electronic step type fan regulator, modular type
42ITC of ceiling fan
43S/F/F 1200 mm SWEEP CEILING FAN WITH REGULATOR
44S/F/F 15/16 W LED BULB
459'' EXHAUST FAN
46P/F 25mm x 5mm copper earth strip in surface/ recess :-
47Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc., as required.
48S/L 25 mm x 6 mm G.I. earth strip in ground :-
49Supplying and laying 25 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including soldering etc.
50P/F G.I. lightning conductor finial :-
51Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
52G.I. earth plate electrode :-
53Earthing with G.I. earth plate 600mm x 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
54P/ F G.I. Lightning conductor tape in horizontal run :-
55Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete etc. as required (horizontal run).
56P/ F G.I. Lightning conductor tape in vertical run :-
57Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete etc. as required (vertical run).
58Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
59Supply of following sizes and core PVC/XLPE insulated, PVC sheathed armoured electrical cable with aluminium conductor for working voltage upto 1.1 KV etc as required.
603.5c x 95 sq.mm
6111 KV cable laying upto 120 sq.mm. in same trench :- Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
62E/W excavation in foundation do..do..asper E/I
63P/L 60 mm thick paver block.
64Providing PCC M15
65Carriage of materials
66chips
67Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes concealed work
6815 mm nominal
6920 mm nominal
70Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,external pipes, 25 mm nominal
71Making holes in walls for laying G.I. pipes and restoring the same after pipe laying with complete job 125 mm thick wall
72Providing and fixing gate valve of approved quality with complete job, 25 mm dia
73Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
74Providing and fixing PTMT bib cock of approved quality and colour.
75Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap
76Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other with complete job , 580 mm long with 12.50 liter low level PVC Cistern
77S/F/F PVC S.W.R pipe (Supreme)
78110 mm
7975 mm
80PROVIDING URINAL FOR GENTS
81Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. Flexible pipe 32mm dia.
82Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
83Providing and fixing on wall face unplasticised Rigid PVC moulded fitting/accessores for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382leaving 10 mm gap for thermal expansion
84110x110x110mm Single tee without door
8575mm bend
86110 mm bend
87Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length,including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete.
88110 mm
89E/W IN EXCAVATION IN FOUNDATION
90Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches.....do.
91PROVIDING SAND IN FILLING
92PROVIDING 75A, B/F/S
93Providing P.C.C M20 in foundation and plinth
94PROVIDING 50mm THICK PCC M20 IN DPC
95PROVIDING 75B, B/W(1:6) IN foundation and plinth
96PROVIDING 75 B, B/W(1:6) IN S & S
97Providing 125 mm th. 75A B/W (1:4) in S/S
98PROVIDING RCC M20 IN SLABS
99Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
100Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
101providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing -do-do- TMT Fe-500 (Only Valid for SAIL & TATA Steel)
1028mm (75%)
103Providing and laying rectified glazed ceramic floor tiles--do--do--complete job. 300x300mm Size
104Providing and laying 6 mm precast white glazed tiles in walls over 12 mm cemnt slurry -do-flush pointed
105Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
106Providing two coats of snowcem of approved shade and make over old surface including washing cleaning and preparing the walls, scaffolding , curing and taxes all complete as per building specification and direction of E/I.
107CARRIAGE OF MATERIALS
108(A) Sand - (1+19) km
109(B) S/Chips - (1+29) km
110( C ) Bricks-(1+7)KM
111E/W IN EXCAVATION IN FOUNDATION.
112E/W IN BACK FILLING
113Filling in foundation trenches and plinth in layers.. Obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I
114PROVIDING SAND IN FILLING
115PROVIDING 75B, B/F/S
116PROVIDING PCC M15 IN FOUNDATION
117PROVIDING RCC M20 IN FOOTINGS
118PROVIDING RCCM20 IN COLUMNS
119PROVIDING 75B, B/W(1:6) IN F & P
120PROVIDING 50mm THICK PCC M20 IN DPC
121PROVIDING 75B, B/W(1:6) IN S & S
122PROVIDING RCC M20 IN LINTEL BAND, BEAMS etc.
123PROVIDING TOR STEEL IN REINFORCEMENT
12410 mm
12512 - 20 mm
126COST OF Centering and shuttering for -Chhajja
127(5.3.17.20)ROOF
1285.3.17.21 TIE BEAM
1295.3.17.1 COLUMNS footing=2*27*(4.5+4)*1.0
1305.3.17.6 COLUMNS in S/S
1315.3.17.7 STAIR
132PROVIDING 6 mm CP(1:4) IN CEILING
133PROVIDING 12 mm CP(1:6) ON WALLS
134PROVIDING 12 mm CP(1:3) ON WALLS WITH 1.5 mm PUNNING ON OUTER WALL BETWEEN GL TO PL
135Finishing walls with acrylic smooth exterior paint
136Providing and applying white cement based putty of average thickness of 1mm
137PROVIDING 2- COAT OF OBD WITH ONE COAT OF PRIMER
138PROVIDING 16 mm DIA. FAN HOOKS
139PROVIDING m.s. sheet gate with chowkhat
140PROVIDING 20x6 mm m.s. grill
141PROVIDING 2- COAT OF SE PAINT WITH ONE COAT OF PRIMER ON STEEL SURFACE
142MAKING PLINTH PROTECTION
143Providing 50mm th. CC in flooring
144Lettering with Black japan paint
145CARRIAGE OF MATERIALS
146(A) Sand - (1+19) km
147(B) S/Chips - (1+29) km
148(C ) BRICKS - (1+7) KM
149Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 4382 leaving 10 mm gap for thermal expansion (i) Single socketed pipes.
15075mm Diameter
151Providing and fixing on wall face unplasticised Rigid PVC moulded fitting/accessores for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382leaving 10 mm gap for thermal expansion
15275mm bend
153Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length,including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete.
154110 mm
155Wiring for light point/ fan point/exhaust fan point / call bell point with 1.5 sq.mm FR PVC Modular type GROUP - C
156Wiring for light/power plug with 2x 4 sq.mm FR PVC insulated, copper conductor
157Circuit/submain wiring in PVC conduit
1582X2.5 sq mm +1 x 2.5sq mm earth wire
1592X4sq mm +1 x 4sq mm earth wire .
160Supplying and fixing of following way single pole & neutral, sheet steel , MCB distribution
16112way SPN double door.
162Supplying and fixing 5 amps to 32 amps, rating, 240 volts, 'B' series
1636/32amp Single pole
164Supplying and fixing 5 amps to 32 amps, rating, 240 volts, 'C' series, maniature circuit
1656/32amp SPN
166S/F ceiling rose including connection etc.as reqd.
167S/F brass battan / angle holder including connection etc.as reqd.
168Supplying and fixing following Modular type
1695/6 amps switch
1705/6 amps socket outlet
17115/16 amps switch
17215/16 amps socket outlet
173ITC of ceiling fan
174S/F/F 1200 mm SWEEP CEILING FAN WITH REGULATOR
175S/F/F 15/16 W LED BULB
176EARTH WORK IN EXCAVATION IN OF FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I. (5.1.1 bcd)
177Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) do....do....5.1.7
178Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) (5.1.10 bcd)
179Providing designation 75-B, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge. (5.6.3 bcd)
180Providing P.C.C/R.C.C. M-20 with nominal mix of (1:1.5:3) in Foundation with approved quality of stone chips (20 to 6 mm size) and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixture, placing in position, vibration, striking, curing, taxes and royalty all complete as per building specification & direction of E/I. (5.3.10 bcd)
181Providing RCC M200 with nominal mix of (1:1.5:3) in plinth beam ---- do ---- all complete as per building specification and direction of Engineer Incharge.( 5.3.11 bcd)
182Providing RCC m.200 with nominal mix of (1:1.5:3) in columns ---- do ---- all complete as per building specification and direction of Engineer Incharge. ( 5.3.10 bcd)
183Providing designation 75 B BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge. ( 5.2.11 bcd)
184Providing PCC M15 with nominal mix of (1:2:4) in band coping at Top of Wall. ( 5.3.2.2 bcd)
185Providing 12 mm thick water proof CEMENT PLASTER (1:6) clean coarse sand of F.M.1.5 and 1.5mm cement punning including cost of screening, curing making grooves with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I . ( 5.7.1 bcd)
186Providing two coat of snowcem of approved shade and make over on a new surface all complete job as per specification and direction of E/I 5. 8 .24 bcd
187Supplying, fixing, & ftting M.S Gril Gate do…do…. all complete job. 5.5.30
188Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia …….do………….do…..(dsr 16.53)
189Supplying fitting and fixing M.S angle 40x40x4mm IS2062 gade A Angle hoising in steps welded anchorage fixed in concrete steps at the time of casting do,………..do………..(5.5.33)
190TOR STEEL @100 KG /M3 OF R.C.C. TOTAL STEEL QTY. (5.5.5)
191Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and StrutS ….do…..do…..5.3.17.6
192Centering and shuttering do..do.. Asper E/I.
193carriage of material Cement
194Cement
195steel
196Stone chips
197bricks
198E/W IN EXCAVATION IN FOUNDATION
199E/W IN BACK FILLING
200PROVIDING SAND IN FILLING
201PROVIDING 75B, B/F/S
202PROVIDING PCC M20 IN FOUNDATION
203reinforced cement concrete work in beam suspended floor lintels band plinth with nominal mix of( 1:1.5:3)
204Brick work in foundation and plinth (1:4)..…d0…d0…..
205Providing tor steel reinforcement of 8mm ,10mm 12mm and 16mm…do……..do……
206Providing 12 mm thick cement plaster (1:3) and punning
207Structural steel work in single section, fixed with or without connecting plate,including……….all complete.
208S/F/F MS square Pipe 50x50x4 mm in purlins
209Providing and fixing of galvanised iron profile sheet of 0.50 mm total coated thickness do…do…complete job.
210Providing and fixing UV stabilized fibreglass reinforced plastic sheet roofing upto any pitch.. do…do…complete job.
211Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating…….using self drilling/ self tapping screws complete :12.51.1 Ridges plain (500 - 600mm)
212Providing two coat of SE Paint with one coat of primer on steel surface…..E/I.
213Carriage of materials
214i) Bricks
215ii) Sand
216iii) S/Chips
217GST @18%
218LABOURCESS @1% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57247832
AUTHORITY Local Bodies
TENDER VALUE 94.48 Lakhs
LAST DATE 03-09-2026
Authority
Authority Name Zilla Parishad
Work Description Tender for Renovation Of Upgradation High School Sangr Ur ,Block - Gola, Ramgarh
Basic Detail
Tender No ZP/RAMGARH/08/2026-27
Bidding Type Tender
Location
City Ramgarh
State Jharkhand
Key Dates
Publish Date 27 Aug 2026
Submission Date 03 Sep 2026
Open Date 05 Sep 2026
Finance
Tender Value 94.48 Lakhs
Tender Fee 10000
EMD 1.89 Lakhs
Exemption Not Available
Document List
06SBDUPGSANGRAMPUR.pdf
56cde80c-81d9-4992-988f-758c2a1d7015.html
BOQ_159541.xls
Tendernotice_1 (22).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Sep 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
pdf

06SBDUPGSANGRAMPUR.pdf

html

56cde80c-81d9-4992-988f-758c2a1d7015.html

xls

BOQ_159541.xls

pdf

Tendernotice_1 (22).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders