| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I. |
| 3 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 4 | Providing 12 mm thick Cement plaster (1:6) with clean coarse sand of F.M.1.5 including screening, curing eith all leads and lifts of water, scaffilding taxes and royalty all complete as per building specification and direction E/I |
| 5 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 6 | Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete. |
| 7 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 8 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 9 | Finishing walls with Premium Acrylic Smooth exterior paint with Siliconeadditives of required shade. |
| 10 | New work (Two or more coats applied @ 1.43 ltr/10 sqm overand including priming coat of exterior primer applied @ 0.90litre/10 sqm) |
| 11 | Water proofing for old and New Roof Slab : - Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps:- |
| 12 | Surface preparation :- Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint/coating and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt. Ltd/MYK schomberg/Dr. Fixit/fosroc or equivalent. Proiding and reparing of all corners and joints such as those between the parapet wall and the roof slab etc. shall be chamfered with 150mm x 150mm fillet of mortar (Cement sna - 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr. Fixit or equivalent. |
| 13 | Before chamfering surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. |
| 14 | 1st coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600mm by brush or roller. After 1st coat of application, 45 gsm of fibre glass cloth to lay when the first layer is still green, 1st coat should be applied @ 1.50 kg/sqm/coat. For the purpose of measurement the entire treated surface will be measured. |
| 15 | 2nd Coat :- To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @ 0.7 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured. After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be doen as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing coating to be protected from damage before screed over it. Water proofing Brand-Sika Topseal 109hi/Fosroc Brushbond RFX/Dr Fixit Pidifin 2K/MYK Auafin TG, Product Performance - chemical |
| 16 | Base part A : Acrylic copolymer, Part B : Specially graded cementtitious powder - Density 1.6 kg/l (mixed density) at +270C Tensile strength ~ 2N/mm2 after 28 days (with Fibre cloth) (according to ASTM D 2370) Pullout Bond Strength ~ 2 N/mm2 (concrete failure) (According to ISO 4624) Slant-shear bond strength~4 N/mm2 (According to FIP 5.15) Elongation at Break ~ 35% without Fibre Cloth and 20% with fibre cloth (According to ASTM D 2370) |
| 17 | Protection of treatedsurface with PCC : - The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 Mt x 2mt keeping 6mm gap between the panel joint intergal water proofing admixture conforming to IS 2645 @ of 100 ml per bag of cement to be added in the acreed concrete (paid separately for this items) all corners shall be chamfered with 150mm x 150mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between PVC pipe outlet and concerte surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insentive epoxy putty of Sika India pvt Ltd/MYK Schomberg/Dr. Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured.\\" |
| 18 | Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately) Brand - Sika India Pvt. Ltd./MYK Schomberg/Dr. Fixit/Fosroc. Warantly for five years. |
| 19 | Covering of treated surface with PCC :- Providing 25mm thick cement concrete M-50 (1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with approved quality of stone chips of 20mm to 6mm size graded and cleaned sand of F.M. to 3 including screening, shuttering and mixing cement concrete in mixer with admixture in integral water proofing and placing in position, skirting curing, taxes and roaylty all complete as per building specification and directions of E/I. Panels that has been left should be casted next day. There should be 6mm gap between Panels Brand-Sika-plastocrate plus, MYK proof WP 10, Fosroc-Conplast X 4211C, Dr. Fixit Pidproof LW+ or equivalent. |
| 20 | Providing 250mm wide brick drain in cement mortar (1:6) with as. 150mm clear depth and 250mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 21 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 22 | Supplying, fitting and fixing fully glazed steel door, window or ventilations of standard rolled 'Z' and mullion steel sections and size as per IS-1038 joints met and welded with 100X16X3mm M.S. lugs fixed in cement concrete (1:2:4) block 15X10X10cm, size including cost of oxidised iron fittings, with hinges, handle per steps, catch springs, 3mm thick plain glass panes with Aluminimum beads and inner frame fixed with lugs with 20mm long 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint carriage to work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction of E/I. |
| 23 | Providing and laying Double Charge vitrified floor tiles in Different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS 15622/ISO 13006, of approved make , in all colour and shades laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointed with grey cement [email protected] kg /sqm including grouting the joints with white cement and matching pigment etc.Size of tiles 600x600mm |
| 24 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 25 | Glazed Vitrified tiles Matt/Antiskid finish of size |
| 26 | Size of Tile 600 x 600 mm |
| 27 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I.- With commercial grade white |
| 28 | Providing designation 75B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I. |
| 29 | Providing 12 mm thick Cement plaster (1:6) with clean coarse sand of F.M.1.5 including screening, curing eith all leads and lifts of water, scaffilding taxes and royalty all complete as per building specification and direction E/I |
| 30 | Providing and fixing concertina coil fencing with punched tapeconcertina coil 600 mm dia 10 metre openable length ( total length90 m), having 50 nos rounds per 6 metre length, upto 3 m height ofwall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apartand with 9 horizontal R.B.T. reinforced barbed wire, stud tied withG.I. staples and G.I. clips to retain horizontal, including necessarybolts or G.I. barbed wire tied to angle iron, all complete as per directionof Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Springcore (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mmwith tape (0.52 mm thick) and weight 43.478 gm/ metre (cost ofM.S. angle, C.C. blocks shall be paid separately) |
| 31 | Supplying fitting and fixing M.S angle 40x40x4mm IS2062 gade A Angle hoising in steps welded anchorage fixed in concrete steps at the time of casting do,………..do………..(5.5.33) |
| 32 | 2 ACR |
| 33 | Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 34 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string course, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reionforcement :(1:1.5:3 (1 cement : 1.5 : coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size) |
| 35 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15\\" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size). |
| 36 | Suspended Floors, roofs, landings, balconies and access platform |
| 37 | Lintels, beams, Plinth beams, girders, bressumers and cantilevers |
| 38 | Column, Pillars, Piers, Abutments, Posts and struts |
| 39 | Weather shade, Chajjas, corbels etc. including edges |
| 40 | Providing Toe steel reinforcement of following dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel) |
| 41 | 8mm @ 35% |
| 42 | 10mm @ 15% |
| 43 | 12mm to 25 mm @50% |
| 44 | S/F M.S. grill made of 20 x 6mm M.S. flat / Square bar as per approved design and drawing, properly fabricated with joints continous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction ofE/I. (Where materials is not supplied by the deptt.) |
| 45 | Providing and fixing fan hooks of 16mm dia M.S. bar & 1 meter long, bent torequired size and shape, placed in position and fixed in the R.C.C.slab/beam at the time ofcasting all complete as per building specification and direction of E/I. |
| 46 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 47 | Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 48 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 49 | Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 50 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 51 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specificatio). |
| 52 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 53 | Water proofing for old and New Roof Slab : - Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps:- |
| 54 | Surface preparation :- Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint/coating and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt. Ltd/MYK schomberg/Dr. Fixit/fosroc or equivalent. Proiding and reparing of all corners and joints such as those between the parapet wall and the roof slab etc. shall be chamfered with 150mm x 150mm fillet of mortar (Cement sna - 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr. Fixit or equivalent. |
| 55 | Before chamfering surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. |
| 56 | 1st coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600mm by brush or roller. After 1st coat of application, 45 gsm of fibre glass cloth to lay when the first layer is still green, 1st coat should be applied @ 1.50 kg/sqm/coat. For the purpose of measurement the entire treated surface will be measured. |
| 57 | 2nd Coat :- To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @ 0.7 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured. After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be doen as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing coating to be protected from damage before screed over it. Water proofing Brand-Sika Topseal 109hi/Fosroc Brushbond RFX/Dr Fixit Pidifin 2K/MYK Auafin TG, Product Performance - chemical |
| 58 | Base part A : Acrylic copolymer, Part B : Specially graded cementtitious powder - Density 1.6 kg/l (mixed density) at +270C Tensile strength ~ 2N/mm2 after 28 days (with Fibre cloth) (according to ASTM D 2370) Pullout Bond Strength ~ 2 N/mm2 (concrete failure) (According to ISO 4624) Slant-shear bond strength~4 N/mm2 (According to FIP 5.15) Elongation at Break ~ 35% without Fibre Cloth and 20% with fibre cloth (According to ASTM D 2370) |
| 59 | Protection of treatedsurface with PCC : - The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 Mt x 2mt keeping 6mm gap between the panel joint intergal water proofing admixture conforming to IS 2645 @ of 100 ml per bag of cement to be added in the acreed concrete (paid separately for this items) all corners shall be chamfered with 150mm x 150mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between PVC pipe outlet and concerte surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insentive epoxy putty of Sika India pvt Ltd/MYK Schomberg/Dr. Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured.\\" |
| 60 | Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately) Brand - Sika India Pvt. Ltd./MYK Schomberg/Dr. Fixit/Fosroc. Warantly for five years. |
| 61 | Over Roof Top |
| 62 | Covering of treated surface with PCC : Providing 50 mm thick cement concrete M-20 (1:1.5:3) maintaining slope in alternate 2mt x 2 mt panels with approved quality of stone chips of 20mm to 6mm size graded and cleaned sand of F.M. 2.5 to 3 including screening, shuttering and mixing cement concrete in mixer with admixture of integral water proffing and placing in position, skirting curing, taxes and royalty all complete as per building specification and direction of E/I. Panels that has been left should be casted next day. there should be 6mm gap between Panels Brand-Sika-Plastocrate plus, MYK proof WP 10, Fosroc-Conplast X421 ic Dr. Fixit Pidiproof LW+ |
| 63 | Providing and fixing 1mm thick M.S. sheet doors, windows and ventilators with angle iron frames of mild steel Angle sections of size 35x35x5 mm, joints mitred andwelded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existingT-iron frame or to the wall with dash fastener, including fixing of necessarybutt hinges and screws and applying a priming coat of approved steelprimer, all complete as per the direction of Engineer-In-charge. |
| 64 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 65 | 110mm dia |
| 66 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 67 | Couplar - 110mm |
| 68 | Providing P.V.C BEND 110mm |
| 69 | Providing P.V.C shoe 110mm |
| 70 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 71 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 72 | Qty. same as extrenal wall plaster item no. 5.7.2 |
| 73 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 74 | On Wall |
| 75 | ELECTRICAL WORKS(2ACR) |
| 76 | Point wiring in PVC conduit, with modular type switch - Point wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required. |
| 77 | Group C |
| 78 | Power plug wiring in PVC conduit (2 x 4 sq.mm) - Wiring for light/power plug with 2 x 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 79 | Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 80 | 2x1.5 Sqmm + 1x1.5 sqmm earth wire (For 5/6A Plug Points) |
| 81 | 2x2.5 Sqmm + 1x2.5 sq mm earth wire |
| 82 | S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required |
| 83 | 5/6 amps, one way switch |
| 84 | 5/6 amps, 3 pin socket outlet |
| 85 | S/F Modular boxes, base & cover plate - Supplying and fixing following size/modulaes G.I. box along with modular base & cover plate for modular switches in recess etc. as required. |
| 86 | 1 or 2 (78mm x 78mm x 45mm) |
| 87 | S/F S.P. MCB DB - Supplying and fixing following way single pole netural, sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) |
| 88 | 8 way, single door |
| 89 | S.I.T.C. of following rating, surface mounted LED light fitting, suitable for 230V 50Hz, single phase supply etc. complete as required. |
| 90 | 20/22W LED Tube Light |
| 91 | 9/10Watt LED Bulb |
| 92 | BOUNDRY WALL |
| 93 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 94 | Extra for earthwok in hard soil as per specification and direction of E/I. (Vide classification of soil item - B). |
| 95 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 96 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 97 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 98 | Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\" x 4.5\\" x 3\\") in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 99 | Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level. |
| 100 | 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) |
| 101 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to Plinth Level- 1:1.5:3 (1 cement ; 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size) |
| 102 | Foundation |
| 103 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string course, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reionforcement :(1:1.5:3 (1 cement : 1.5 : coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size) |
| 104 | Column above tie beam |
| 105 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15\\" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size). |
| 106 | Lintel Band |
| 107 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 108 | Foundations, footing, bases of columns, etc. for mass concrete |
| 109 | RCC in Foundation |
| 110 | Lintels, beams, Plinth beams, girders, bressumers and cantilevers |
| 111 | Column, Pillars, Piers, Abutments, Posts and struts |
| 112 | Column |
| 113 | Providing TMT steel reinforcement of 8mm-16mm. Dia. Rods as per approved design and drawing excluding carriage of TMT bars to work site, ...E/I. |
| 114 | 8mm dia(TMT coil Fe 500) (Only Valid for SAIL & TATA Steel) @ 20% |
| 115 | 10 mm dia(TMT coil Fe 500) (Only Valid for SAIL & TATA Steel) @ 20% |
| 116 | 12 mm dia(TMT coil Fe 500) (Only Valid for SAIL & TATA Steel) @ 60% |
| 117 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 118 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 119 | Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/I. |
| 120 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specificatio). |
| 121 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 122 | Supplying at site Angle iron post & strut of required size includingbottom to be split and bent at right angle in opposite direction for10 cm length and drilling holes upto 10 mm dia. etc. complete. |
| 123 | Providing and fixing concertina coil fencing with punched tapeconcertina coil 600 mm dia 10 metre openable length ( total length90 m), having 50 nos rounds per 6 metre length, upto 3 m height ofwall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apartand with 9 horizontal R.B.T. reinforced barbed wire, stud tied withG.I. staples and G.I. clips to retain horizontal, including necessarybolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Springcore (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mmwith tape (0.52 mm thick) and weight 43.478 gm/ metre (cost ofM.S. angle, C.C. blocks shall be paid separately) |
| 124 | STAGE |
| 125 | E/W in foundation trenches in all kinds of soil -do- -do- all complete job as per building specification and direction of E/I. |
| 126 | Providing 75B brick flat soling -do- -do- all complete job as per specification and direction of E/I. |
| 127 | Providing P.C.C. (1:2:4) in foundation and plinth with Stone Chips -do- -do- all complete job as per building specification and direction of E/I. |
| 128 | Providing 75B brick work in C.M. (1:6) in foundation and plinth -do- -do- all complete job as per building specification and direction of E/I. |
| 129 | Providing 25mm thick A.P.S. flooring (1:2:4) -do- -do- all complete job. |
| 130 | Providing 12mm thick C.P. (1:4) with neat cement punning -do- -do- all complete job as per building specification and direction of E/I. |
| 131 | E/W filling in foundation trenches and plinth -do- -do- all complete job. |
| 132 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.- Hot finished welded type tubes |
| 133 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 134 | Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 135 | TOILET |
| 136 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 137 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) |
| 138 | Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation frenches within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume). |
| 139 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode measurement compacted Volume). |
| 140 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement compacted volume). |
| 141 | Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 142 | Providing designation 75B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I. |
| 143 | Providing designation 125mm thick reinforced designation 75A brick work in (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement0 all complete as per building specification and direction of E/I. |
| 144 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 145 | 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) |
| 146 | Making plith protection 50mm thick of cement concrete 1:3:6 (1 Cement : 3 coase sand ( zone-III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth |
| 147 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to Plinth Level- 1:1.5:3 (1 cement ; 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size) |
| 148 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string course, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reionforcement :(1:1.5:3 (1 cement : 1.5 : coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size) |
| 149 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15\\" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size). |
| 150 | Total = X1+X2+X3 |
| 151 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 152 | Foundations, fotting, bases of columns, etc. for mass concrete |
| 153 | Suspended Floors, roofs, landings, balconies and access platform |
| 154 | Lintels, beams, Plinth beams, girders, bressumers and cantilevers |
| 155 | Column, Pillars, Piers, Abutments, Posts and struts |
| 156 | Providing Toe steel reinforcement of following dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel) |
| 157 | 8mm @50% |
| 158 | 10mm @ 20 % |
| 159 | 12mm to 25mm @ 30 % |
| 160 | Supplying, fitting and fixing fully glazed steel door, window or ventilations of standard rolled 'Z' and mullion steel sections and size as per IS-1038 joints met and welded with 100X16X3mm M.S. lugs fixed in cement concrete (1:2:4) block 15X10X10cm, size including cost of oxidised iron fittings, with hinges, handle per steps, catch springs, 3mm thick plain glass panes with Aluminimum beads and inner frame fixed with lugs with 20mm long 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint carriage to work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction of E/I. |
| 161 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering texes royalty all complete as per building specification and direction of E/I. |
| 162 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 163 | Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 164 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 165 | Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 166 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l. |
| 167 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specificatio). |
| 168 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 169 | Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 170 | Providing 19mm thick water proof cement plaster (1:3) with clean coasre sand of F.M. 1.5 with integral water proofing compound Liquid @ 125ml per bag cement including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. Brand-Sika-Plastocrate plus, MYK proof WP 10, Fosroc-Conplast X4211C, Dr. Fixit Pidiproof LW+ or Equivalent |
| 171 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Framesof cross-section 90 mm x 45 mm having single rebate of 32 mm x 15mm to receive shutter of 30 mm thickness. The laminate shall be mouldedwith fire resistant grade unsaturated polyester resin and chopped mat.Door frame laminate shall be 2mm thick and shall be filled with suitablewooden block in all the three legs. The frame shall be covered with fiberglass from all sides. M.S. stay shall be provided at the bottom to steadythe frame. |
| 172 | Providing and fixing to existing door frames. - 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelleddoor shutter of required colour and approved brand andmanufacture, made with fire - retardant grade unsaturatedpolyester resin, moulded to 3 mm thick FRP laminate forforming hollow rails and styles, with wooden frame and suitableblocks of seasoned wood inside at required places for fixingof fittings, cast monolithically with 5 mm thick FRP laminatefor panels conforming to IS: 14856, including fixing to frames. |
| 173 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 174 | Glazed Vitrified tiles Matt/Antiskid finish of size - Size of Tile 600 x 1200 mm |
| 175 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 176 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 177 | ELECRICAL WORK IN TOILET |
| 178 | Point wiring in PVC conduit, with modular type switch - Point wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required. |
| 179 | Group C |
| 180 | Power plug wiring in PVC conduit (2 x 4 sq.mm) - Wiring for light/power plug with 2 x 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 181 | Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 182 | 2x1.5 Sqmm + 1x1.5 sqmm earth wire (For 5/6A Plug Points) |
| 183 | 2x2.5 Sqmm + 1x2.5 sq mm earth wire |
| 184 | S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required |
| 185 | 5/6 amps, one way switch |
| 186 | 5/6 amps, 3 pin socket outlet |
| 187 | S/F Modular boxes, base & cover plate - Supplying and fixing following size/modulaes G.I. box along with modular base & cover plate for modular switches in recess etc. as required. |
| 188 | 1 or 2 (78mm x 78mm x 45mm) |
| 189 | S/F S.P. MCB DB - Supplying and fixing following way single pole netural, sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) |
| 190 | 8 way, single door |
| 191 | S.I.T.C. of following rating, surface mounted LED light fitting, suitable for 230V 50Hz, single phase supply etc. complete as required. |
| 192 | 20/22W LED Tube Light |
| 193 | 9/10Watt LED Bulb |
| 194 | Sanitary items |
| 195 | Providing and fixing Gun metal full way valve of approved quality, all complete as per specification and direction of E/I. |
| 196 | (c) 25mm dia and weight not less than 500gms. |
| 197 | (d) 32mm dia and weight not less than 700gms. |
| 198 | Cutting chhajja or corince for laying G.I. pipe and restoring the same with R.C.C. (1:2:4) brick work in cement mortor (1:4) as per specification and direction of E/I. |
| 199 | Making holes in walls for laying G.I. pipe and restoring the same after pipe laying as per specification and direction of E/I. |
| 200 | 250 mm thick wall |
| 201 | Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of exacavted earth within initial lead and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I. |
| 202 | 20x 0.500 x 0.600 |
| 203 | Labour for alying, fitting and fixing NP2 R.C.C. spun pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leakproof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complet as per specification and direction of E/I.150mm |
| 204 | Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 205 | Supplying and fixing NP2 Hume pipe etc. (150mm dia) |
| 206 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 207 | 75 mm |
| 208 | 110 mm |
| 209 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 210 | Coupler |
| 211 | 75 mm |
| 212 | 110 mm |
| 213 | Single pushfit Coupler |
| 214 | 75 mm |
| 215 | 110 mm |
| 216 | Single tee with door |
| 217 | 75 mm |
| 218 | 110 mm |
| 219 | Single tee without door |
| 220 | 75 mm |
| 221 | 110 mm |
| 222 | Bend 87.5° |
| 223 | 75 mm |
| 224 | 110 mm |
| 225 | Shoe (Plain) |
| 226 | 75 mm |
| 227 | 110 mm |
| 228 | Supplying, fitting and fixing flat back or angular, lipped front vitreous white glazed earthen ware urinal of Hindustan \\"Parry\\" or any other approved I.S.S. Make with 5 liters capacity C.I. Automatic fulsing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S. bracket, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400grams, 15mm P.V.C./Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/I.- (a) Flat back or standing corner (600mmX350mm) |
| 229 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 230 | Flexible Pipe - 40 mm |
| 231 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 232 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 233 | Internal Work - Exposed on Wall |
| 234 | 25 mm nominal dia Pipes |
| 235 | 32 mm nominal dia Pipes |
| 236 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 237 | Concealed Work |
| 238 | 15 mm |
| 239 | 20 mm |
| 240 | Providing and fixing PTMT grating of approved quality and colour. |
| 241 | C.P. Gratings- 125 mm nominal dia with 25 mm waste hole |
| 242 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 243 | With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 |
| 244 | Construction of septic Tank |
| 245 | Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and dirction of E/I. |
| 246 | Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm PVC waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I. |
| 247 | Special type C.P. Bath room Fitting for V.I.P.Buildings(JAL, Jaquar, Mark or Equivalent) |
| 248 | Pillar cock (Long neck) |
| 249 | Bib cock (2 Way) |
| 250 | SEPTIK TANK |
| 251 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees shurbs all complete as per approved design building specification and direction of E/I. |
| 252 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) |
| 253 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 254 | Providing designation 75Bwork in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I. |
| 255 | Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level. |
| 256 | 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40mm nominal size) |
| 257 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15\\" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size). |
| 258 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 259 | Suspended Floors, roofs, landings, balconies and access platform |
| 260 | Lintels, beams, Plinth beams, girders, bressumers and cantilevers |
| 261 | Providing Toe steel reinforcement of following dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel) |
| 262 | 10mm dia |
| 263 | 12mm dia |
| 264 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I |
| 265 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 266 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I. |
| 267 | Carriage of Material |
| 268 | Bricks - |
| 269 | Sand - |
| 270 | Chips - |
| 271 | Metal |
| 272 | Cement |
| 273 | Local Sand - |
| 274 | Fly ash brick |
| 275 | GST @18% |
| 276 | LABOURCESS @1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender