Tender For Construction Of Multipurpose Hall And Sports Complex At Nuh Haryana.
Tender Value
12.34 Crore
Estimated cost
Bid Submission
21 Sep 2026
22 days left
EMD
24.69 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Multipurpose Hall And Sports Complex At Nuh Haryana.
BOQ
| Sl. No. | Item Description |
| 1 | DSR 28.5.1 : `Supplying and laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring andLSZH outer sheath complete as required.` |
| 2 | DSR 27.13 : Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 3 | DSR 28.2.1.1 : Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. |
| 4 | DSR 28.2.3 : Supplying, installation, testing and commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 5 | DSR 28.2.4 : Supplying, installation, testing and commissioning of intelligent analog addressable photothermal detector (Smoke and Heat) complete with mounting base complete as required. |
| 6 | DSR 28.5.3.2 : Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. |
| 7 | DSR 28.2.5 : Supplying, installation, testing and commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 8 | DSR 28.2.14 : Supplying, installation, testing and commissioning of addressable manual call point complete as required. |
| 9 | DSR 28.2.6 : Supplying, installation, testing and commissioning of intelligent addressable programmable sounder complete as required. |
| 10 | DSR 28.2.7 : Supplying, installation, testing and commissioning of fault isolator complete with base as required. |
| 11 | DSR 28.2.19 : Supplying, installation, testing and commissioning of fire fighter phone jack complete as required. |
| 12 | DSR 28.2.12 : Supplying, installation, testing and commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required. |
| 13 | DSR 39.3.12 : Supplying, installation, Testing and commissioning of followingcapacity 24 port Layer 2 indoor Network Switch having features andspecifications etc. as mentioned here under: At least 24 X RJ-45Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFPPorts with non-blocking architecture by having Switching capacityof min. 168Gbps and packet forwarding rate of 125Mpps or higher,16K MAC table. Console Port, USB port, Stacking support of min. 9units per stack. Internal dual AC Power supply, STP, RSTP, MSTP,BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMPSnooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K ormore, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND,VRRPv3, UDP Helper, ECMP. VLAN: 802.1O, Port based, O-in-O,Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping,Server, server Screening. RADIUS , TACACS plus Authentication, OoS:802.1P, 8 queues per port, OoS : WRR, Strict plus WRR, WRED, 802.1p.ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time basedACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCPserver, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah,sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surgeprotection on all Gigabit Ethernet ports and on all GE RJ-45 accessports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Productmust be on Trusted Telecom Portal of Department ofTelecommunication, Government of India, |
| 14 | DSR 5.16 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 15 | Supply and Erection of LED High Bay Light 80watt (including LED driver) with pressure die cast aluminiumhousing with control gear ( with IP 65/ IP 66 protection), CRI Minimum 70, CCT )5700K, toughened glassfitting, LED fixture minimum 120 lumens per watt and operating voltage between 140 to 270 volt, THD (10%ingress protection (as per BIS standards) , surge protection 10kv and above (as per (IS/IEC standards) wattageof each LED High power LED of 1 watt to 5 watt with mandatory modular lenses, input AC frequency 50 Hz ± 3% 5 year warranty including their drivers complete along with erection of the same with connections, testingetc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 16 | DSR 9.1.2 : Brush Less Direct Current (BLDC) Fan with RemoteSupply, Installation, Testing and Commissioning of ceiling fan withBrush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body. Power Factornot less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM(tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) lessthan 10%, remote (preferably mobile app based) for speed control andall remaining accessories including safety pin, nut bolts, washers,temperature rise=75 °C (max.), insulation resistance more than 2 megaohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fancompliant to IS 374:2019 fan i/c external connections with 1.5 sq.mmFRLS/HFFR, PVC insulated copper conductor single core cable andearthing etc. as required. Cost for 10 fans |
| 17 | Supplying, installation, testing and commissioning of M.S door and glass fire door size 2100 mm x 900mm fabricated from 1.6mm thick M.S. sheets and M.S angle 40mm x 40mmx6mm complete with glass, locking arrangements to accommodate all accessories.The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of approved shade |
| 18 | `Rubber Expansion BellowProviding and fixing of suitable flexible neoprene rubber expansion joint, single arch with integral rubber flanges with SRR drilled as per BS-10, Table-D, complete as required and as per contract specifications. It shall be suitable for water works and rated for 300 PSI complete as required and as per contract specifications.`150 mm Dia |
| 19 | `Rubber Expansion BellowProviding and fixing of suitable flexible neoprene rubber expansion joint, single arch with integral rubber flanges with SRR drilled as per BS-10, Table-D, complete as required and as per contract specifications. It shall be suitable for water works and rated for 300 PSI complete as required and as per contract specifications.`80 mm Dia |
| 20 | SITC of Required AHU KIT for connection the cooling coils with the VRF/VRV outdoor unit complete with expansion valve,sensors,wired remote controller and PCB etc. to run the AHU as required for mentioned AHU`s In the BOQ and shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs |
| 21 | Centralised Controller SITC Centralised Controller capable of controlling Upto 32 Indoor units to be be controlled . The manufacturer shall have to give full documentation, technical manuals etc. |
| 22 | Ventilation / HVAC (critical): Range capture ventilation system, exhaust ducts, filtration, fans (meets air-change and contamination control) |
| 23 | Lighting and electrical : Lighting and Electrical Installation including Non-glare task lighting, emergency lighting and wiring |
| 24 | Control room and glazing : Fabrication of Aluminum Control room for shooting range with ballistic glass (if required) |
| 25 | Furniture and storage : Providing benches, racks, lockers, admin deskBenches, racks, lockers, admin deskBench 2 = 30000Rack 1 = 15000Lockers 2 = 20000Admin Desk 1 = 15000 |
| 26 | Safety equipment and PPE : First-aid, range flags, signage, fire protection, eye/ear protection supply |
| 27 | Providing and fixing wash basin 32 mm dia SS waste coupling complte in all repsects. NS |
| 28 | `Providing and fixing of SS grating with frame of 150 mm dia or rectangular soze 2-3 mmthick as per approved shape and size complete in all respects. NS` |
| 29 | Providing and fixing SS towel rail 600 mm long. NS |
| 30 | Providing and fiixng SS Khutti (6 No.). NS |
| 31 | `Providing and fixing UPVC 6 kg pressure 110 mm x 110 mm P trap complete in all respect.NS` |
| 32 | Providing and fixing CP BRASS soap Dish Holder (NS) |
| 33 | Providing and fixing CP BRASS towel Ring. (NS) |
| 34 | Providing and fixing Health faucet. NS |
| 35 | `PRIVIDING AND FIXING OF 6KG PRESSURE DOOR BEND (110 MM DIA) COMPLETE IN ALLRESPECT. MAKE: FINOLEX, SUPREME, PRINCE ETC. (NS)` |
| 36 | `PRIVIDING AND FIXING OF 6KG PRESSURE PLAIN BEND 110 MM DIA COMPLETE IN ALLRESPECT. MAKE: FINOLEX, , PRINCE SUPREME. (NS)` |
| 37 | `PRIVIDING AND FIXING OF 6KG PRESSURE PLAIN TEE 110 MM DIA COMPLETE IN ALLRESPECT. MAKE: FINOLEX, SUPREME, PRINCE. (NS)` |
| 38 | `PROVIDING AND FIXING OF 6KG PRESSURE PLAIN Y JUNCTION 110 MM DIA COMPLETEIN ALL RESPECT.MAKE: FINOLEX, SUPREME, PRINCE. (NS)` |
| 39 | `PROVIDING AND FIXING OF 6KG PRESSURE COUPLER 110X100 COMPLETE IN ALLRESPECT. MAKE: FINOLEX, SUPREME, PRINCE. (NS)` |
| 40 | `PROVIDING AND FIXING OF SS FLOOR JALI DOUBLE STAINLESS 110 DIA COMPLETE IN ALLRESPECT. MAKE: ESSESS, JAQUAR, CERA. (NS)` |
| 41 | `PROVIDING AND FIXING OF 6KG PRESSURE CLEAN OUT PLUGE (COP) 110X100COMPLETE IN ALL RESPECT. MAKE: FINOLEX, SUPREME, PRINCE. (NS)` |
| 42 | `Providing , laying , testing and commissoning of Corefit double wall corrugated (DWC) SN-8 pipes as per IS:16098 PART II complete in all respects. Make -Prince or Equvalent`150 mm dia |
| 43 | `Providing , laying , testing and commissoning of Corefit double wall corrugated (DWC) SN-8 pipes as per IS:16098 PART II complete in all respects. Make -Prince or Equvalent`200 mm dia |
| 44 | `Providing , laying , testing and commissoning of Corefit double wall corrugated (DWC) SN-8 pipes as per IS:16098 PART II complete in all respects. Make -Prince or Equvalent`250 mm dia |
| 45 | `Providing , installation , testing and commissioing of submersible , vertical type , water transfer pumping set including the following:Pumps discharge 4 lps and head 30 metre pump status 2 Nos ( 1 working plus I stand by)Pump foundations of required sizerequired valve , fittings, and starter , dry run preventor etc.Any other fittings or accessories required to make system operational.` |
| 46 | Providing and fixing retro reflective high intensity microprismatic sheeting 50mm wide conforming to type -IV of ASTM-D 4956-01 in required colour and size 150mm long existing surfaces like railing in centre verge, guard rail etc including cutting of sheet, cleaning/rubbing of surface complete in all respect and to be entire satisfaction of Engineer-in-charge. (NS) |
| 47 | Providing and laying resilient homogeneous vinyl sheet floor covering 4.5 mm thick, having a vinyl plastic high impact resistant wear layer, High density Double Foam Layer, shock absorption on min 30% with backing intended for use in Heavy commercial buildings, duly fixed to the base floor using adhesive as approved by the manufacturer. The Flooring shall have characteristics such as Stain-resistant, seamless splicing , fireproof, wear-resistant. The cost includes providing Aluminium Nosing to Steps as per Manufacturer details complete in all respects. |
| 48 | Providing and Fixing of floor covering (aproved Color) carpet roll having pile construction of tufted loop pile with composition of 100% nylon, Flammability pass as per 16 CFR 1631#,smoke density ASTM E 662 less than 450,risilient primary backing of woven polypropylene, antistatic, anti-skid property for commercial use, thickens 6.5mm (5 plus 1.5mm) and minimum pile weight of 850g/m2 of roll form with total weight of 1500 g/m2, roll length plus roll width of 30mtrs/400cm, primary backing of action black/felt back with ecoflex NXT, light fastness of )4 and sound insulation of DLW 28db, thermal resentence :0.9 (m2) kw ,installed over existing Cementitious flooring with gorilla epoxy glue, required edging for steps etc. all complete as specified. The carpet flooring shall have 5 years warranty for limited wear and as directed by the Architect / Engineer-in-Charge. (Basic Rates of Carpet Min. Rs 1500/ sq.m) |
| 49 | Providing and Fixing in position, Acoustic Doors 76mm thick, inner frame made kail wood of section 50x50mm duly filled with 50mm/32kg glass wool both sides covered set of 9mm commercial plywood and 4mm teak ply. Door side covered with 12mm teak wood lipping, joined with door frame with parliament hinges, door made of 5”x2.5” section of ivory coast teakwood. All the material duly treated with anti-termite solution, complete with PU polishing, 18” door handle, tower bolts and lock. Note: Contractor to submit shop drawing as per manufacturer selected for approval before ordering. |
| 50 | SandF Puff panel galvanized corrugated sheets |
| 51 | Providing vertical green wall 2.5 mtr high including all necessary frame work (to hang the plants) plants,frames fixed at site ,gst,transportaion complete all as per directed and specified by the Engr-in-Charge |
| 52 | Ballistic protection and partitions : Ballistic-rated rear/backstop, side berms or panels, partitions between lanes (non-penetrable) |
| 53 | Bullet trap / arrester system : Steel or rubberized modular traps (engineered) Bullet trap/arrestor system including engineered steel rubberized modular trap unit, anti-ricochet protection, support framing, installation and teething charges. |
| 54 | Target systems : Manual or electric target carriers (4 lanes) plus target frames |
| 55 | PIPINGRefrigerant PipingSupply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF system including refnet joints etc. complete in all respects duly insulated with closed cell nitrile rubber class `O` of K-Flex,Armacell,A-Flex with UV barrier film as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the department/hvac consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the VRF system. all piping shall be run in cable trays in interior and for exterior there shall be a cable tray both at the bottom and the top. all support system required for the installation of cable trays in interior or exterior shall be in the scope of the HVAC contarctor and nothing extra shall be paid for it. All HVAC piping , drainage and Cabling etc shall run at a height of 6 inches below RCC slab or as per site requirment on continuous cable tray of appropriate sizes. all beams shall be core cut to allow for passage of pipes etc and filled back with expanded polyurethene foam or any cement or plaster. rates quoted are inclusive of core cutting and cable tray etc complate in all all respects including painting in desired colour. on exterior side the cable tray shall be mounted on top and bottom side for added protection. Refrigerant Copper Pipe Make : Totaline,Mandav,Rajco,Jobu6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation |
| 56 | Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF system including refnet joints etc. complete in all respects duly insulated with closed cell nitrile rubber class `O` of K-Flex,Armacell,A-Flex with UV barrier film as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the department/hvac consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the VRF system. all piping shall be run in cable trays in interior and for exterior there shall be a cable tray both at the bottom and the top. all support system required for the installation of cable trays in interior or exterior shall be in the scope of the HVAC contarctor and nothing extra shall be paid for it. All HVAC piping , drainage and Cabling etc shall run at a height of 6 inches below RCC slab or as per site requirment on continuous cable tray of appropriate sizes. all beams shall be core cut to allow for passage of pipes etc and filled back with expanded polyurethene foam or any cement or plaster. rates quoted are inclusive of core cutting and cable tray etc complate in all all respects including painting in desired colour. on exterior side the cable tray shall be mounted on top and bottom side for added protection. Refrigerant Copper Pipe Make : Totaline,Mandav,Rajco,Jobu9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation |
| 57 | Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF system including refnet joints etc. complete in all respects duly insulated with closed cell nitrile rubber class `O` of K-Flex,Armacell,A-Flex with UV barrier film as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the department/hvac consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the VRF system. all piping shall be run in cable trays in interior and for exterior there shall be a cable tray both at the bottom and the top. all support system required for the installation of cable trays in interior or exterior shall be in the scope of the HVAC contarctor and nothing extra shall be paid for it. All HVAC piping , drainage and Cabling etc shall run at a height of 6 inches below RCC slab or as per site requirment on continuous cable tray of appropriate sizes. all beams shall be core cut to allow for passage of pipes etc and filled back with expanded polyurethene foam or any cement or plaster. rates quoted are inclusive of core cutting and cable tray etc complate in all all respects including painting in desired colour. on exterior side the cable tray shall be mounted on top and bottom side for added protection. Refrigerant Copper Pipe Make : Totaline,Mandav,Rajco,Jobu12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation |
| 58 | Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF system including refnet joints etc. complete in all respects duly insulated with closed cell nitrile rubber class `O` of K-Flex,Armacell,A-Flex with UV barrier film as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the department/hvac consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the VRF system. all piping shall be run in cable trays in interior and for exterior there shall be a cable tray both at the bottom and the top. all support system required for the installation of cable trays in interior or exterior shall be in the scope of the HVAC contarctor and nothing extra shall be paid for it. All HVAC piping , drainage and Cabling etc shall run at a height of 6 inches below RCC slab or as per site requirment on continuous cable tray of appropriate sizes. all beams shall be core cut to allow for passage of pipes etc and filled back with expanded polyurethene foam or any cement or plaster. rates quoted are inclusive of core cutting and cable tray etc complate in all all respects including painting in desired colour. on exterior side the cable tray shall be mounted on top and bottom side for added protection. Refrigerant Copper Pipe Make : Totaline,Mandav,Rajco,Jobu15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation |
| 59 | Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF system including refnet joints etc. complete in all respects duly insulated with closed cell nitrile rubber class `O` of K-Flex,Armacell,A-Flex with UV barrier film as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the department/hvac consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the VRF system. all piping shall be run in cable trays in interior and for exterior there shall be a cable tray both at the bottom and the top. all support system required for the installation of cable trays in interior or exterior shall be in the scope of the HVAC contarctor and nothing extra shall be paid for it. All HVAC piping , drainage and Cabling etc shall run at a height of 6 inches below RCC slab or as per site requirment on continuous cable tray of appropriate sizes. all beams shall be core cut to allow for passage of pipes etc and filled back with expanded polyurethene foam or any cement or plaster. rates quoted are inclusive of core cutting and cable tray etc complate in all all respects including painting in desired colour. on exterior side the cable tray shall be mounted on top and bottom side for added protection. Refrigerant Copper Pipe Make : Totaline,Mandav,Rajco,Jobu19.0 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 13 mm thick insulation |
| 60 | PIPINGRefrigerant PipingSupply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF system including refnet joints etc. complete in all respects duly insulated with closed cell nitrile rubber class `O` of K-Flex,Armacell,A-Flex with UV barrier film as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the department/hvac consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the VRF system. all piping shall be run in cable trays in interior and for exterior there shall be a cable tray both at the bottom and the top. all support system required for the installation of cable trays in interior or exterior shall be in the scope of the HVAC contarctor and nothing extra shall be paid for it. All HVAC piping , drainage and Cabling etc shall run at a height of 6 inches below RCC slab or as per site requirment on continuous cable tray of appropriate sizes. all beams shall be core cut to allow for passage of pipes etc and filled back with expanded polyurethene foam or any cement or plaster. rates quoted are inclusive of core cutting and cable tray etc complate in all all respects including painting in desired colour. on exterior side the cable tray shall be mounted on top and bottom side for added protection. Refrigerant Copper Pipe Make : Totaline,Mandav,Rajco,Jobu22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 61 | PIPINGRefrigerant PipingSupply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF system including refnet joints etc. complete in all respects duly insulated with closed cell nitrile rubber class `O` of K-Flex,Armacell,A-Flex with UV barrier film as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the department/hvac consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the VRF system. all piping shall be run in cable trays in interior and for exterior there shall be a cable tray both at the bottom and the top. all support system required for the installation of cable trays in interior or exterior shall be in the scope of the HVAC contarctor and nothing extra shall be paid for it. All HVAC piping , drainage and Cabling etc shall run at a height of 6 inches below RCC slab or as per site requirment on continuous cable tray of appropriate sizes. all beams shall be core cut to allow for passage of pipes etc and filled back with expanded polyurethene foam or any cement or plaster. rates quoted are inclusive of core cutting and cable tray etc complate in all all respects including painting in desired colour. on exterior side the cable tray shall be mounted on top and bottom side for added protection. Refrigerant Copper Pipe Make : Totaline,Mandav,Rajco,Jobu25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 62 | PIPINGRefrigerant PipingSupply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF system including refnet joints etc. complete in all respects duly insulated with closed cell nitrile rubber class `O` of K-Flex,Armacell,A-Flex with UV barrier film as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the department/hvac consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the VRF system. all piping shall be run in cable trays in interior and for exterior there shall be a cable tray both at the bottom and the top. all support system required for the installation of cable trays in interior or exterior shall be in the scope of the HVAC contarctor and nothing extra shall be paid for it. All HVAC piping , drainage and Cabling etc shall run at a height of 6 inches below RCC slab or as per site requirment on continuous cable tray of appropriate sizes. all beams shall be core cut to allow for passage of pipes etc and filled back with expanded polyurethene foam or any cement or plaster. rates quoted are inclusive of core cutting and cable tray etc complate in all all respects including painting in desired colour. on exterior side the cable tray shall be mounted on top and bottom side for added protection. Refrigerant Copper Pipe Make : Totaline,Mandav,Rajco,Jobu28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 63 | PIPINGRefrigerant PipingSupply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF system including refnet joints etc. complete in all respects duly insulated with closed cell nitrile rubber class `O` of K-Flex,Armacell,A-Flex with UV barrier film as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the department/hvac consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the VRF system. all piping shall be run in cable trays in interior and for exterior there shall be a cable tray both at the bottom and the top. all support system required for the installation of cable trays in interior or exterior shall be in the scope of the HVAC contarctor and nothing extra shall be paid for it. All HVAC piping , drainage and Cabling etc shall run at a height of 6 inches below RCC slab or as per site requirment on continuous cable tray of appropriate sizes. all beams shall be core cut to allow for passage of pipes etc and filled back with expanded polyurethene foam or any cement or plaster. rates quoted are inclusive of core cutting and cable tray etc complate in all all respects including painting in desired colour. on exterior side the cable tray shall be mounted on top and bottom side for added protection. Refrigerant Copper Pipe Make : Totaline,Mandav,Rajco,Jobu31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 64 | PIPINGRefrigerant PipingSupply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF system including refnet joints etc. complete in all respects duly insulated with closed cell nitrile rubber class `O` of K-Flex,Armacell,A-Flex with UV barrier film as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the department/hvac consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the VRF system. all piping shall be run in cable trays in interior and for exterior there shall be a cable tray both at the bottom and the top. all support system required for the installation of cable trays in interior or exterior shall be in the scope of the HVAC contarctor and nothing extra shall be paid for it. All HVAC piping , drainage and Cabling etc shall run at a height of 6 inches below RCC slab or as per site requirment on continuous cable tray of appropriate sizes. all beams shall be core cut to allow for passage of pipes etc and filled back with expanded polyurethene foam or any cement or plaster. rates quoted are inclusive of core cutting and cable tray etc complate in all all respects including painting in desired colour. on exterior side the cable tray shall be mounted on top and bottom side for added protection. Refrigerant Copper Pipe Make : Totaline,Mandav,Rajco,Jobu34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 65 | PIPINGRefrigerant PipingSupply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF system including refnet joints etc. complete in all respects duly insulated with closed cell nitrile rubber class `O` of K-Flex,Armacell,A-Flex with UV barrier film as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the department/hvac consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the VRF system. all piping shall be run in cable trays in interior and for exterior there shall be a cable tray both at the bottom and the top. all support system required for the installation of cable trays in interior or exterior shall be in the scope of the HVAC contarctor and nothing extra shall be paid for it. All HVAC piping , drainage and Cabling etc shall run at a height of 6 inches below RCC slab or as per site requirment on continuous cable tray of appropriate sizes. all beams shall be core cut to allow for passage of pipes etc and filled back with expanded polyurethene foam or any cement or plaster. rates quoted are inclusive of core cutting and cable tray etc complate in all all respects including painting in desired colour. on exterior side the cable tray shall be mounted on top and bottom side for added protection. Refrigerant Copper Pipe Make : Totaline,Mandav,Rajco,Jobu38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 66 | PIPINGRefrigerant PipingSupply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF system including refnet joints etc. complete in all respects duly insulated with closed cell nitrile rubber class `O` of K-Flex,Armacell,A-Flex with UV barrier film as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the department/hvac consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the VRF system. all piping shall be run in cable trays in interior and for exterior there shall be a cable tray both at the bottom and the top. all support system required for the installation of cable trays in interior or exterior shall be in the scope of the HVAC contarctor and nothing extra shall be paid for it. All HVAC piping , drainage and Cabling etc shall run at a height of 6 inches below RCC slab or as per site requirment on continuous cable tray of appropriate sizes. all beams shall be core cut to allow for passage of pipes etc and filled back with expanded polyurethene foam or any cement or plaster. rates quoted are inclusive of core cutting and cable tray etc complate in all all respects including painting in desired colour. on exterior side the cable tray shall be mounted on top and bottom side for added protection. Refrigerant Copper Pipe Make : Totaline,Mandav,Rajco,Jobu41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 67 | P/F Insulation min.2 layer coating of Glass cloth ( 7 mill ) with star bond or equivalent adhesive UV stablized on liquid and gas copper pipe line separately on each pipe for outside building/open to sky .dia upto 80 mm (Note : Rate is quated for both liquid and gas pipe) |
| 68 | SITC of DOUBLE SKIN AIR HANDLING UNIS DX TYPE (AHRI CERTIFIED) COMPLETE IN ALL RESPECT (Outdoor/IndoorType)`- Mixing box with manually operated Aluminium Anodised Extruded dampers at fresh and return air cutouts.- Filter section with 50 mm thick box type pre filter on frame.- Coil section with multi-rows deep (6RD) DX cooling coils compatiable with VRV/VRF Outdoor unit.- Fan section with imported DIDW centrifugal backward/Backward curved fan, motor, V-belt and drive set. -Fresh Air Cut out , light in AHU TF Canvass Connection etc.`Following Min.specifications shall be adhered for AHU :`AHU PANELSOuter Skin -_ 0.8 mm pre-coated GIInner Skin -0.8 mm pre-coated GIThickness – Min48±2 mm thick: CFC free PUF injected(Density: Min 48± 2 kg/ Cu. m.)`Unit Base -_ Heavy Duty G.S.S. Profile -_ Thermal Break Aluminum Profile`COOLING COIL : Coil section with multi-rows deep suitable for R410 A Refrigerant type cooling coil.Tube Material -_ CopperTube Thickness—0.5 mm min or as per OEM recomendationHeader material –CU (for DX)Coil Casing -_ G.IFin Thickness and Material – 0.15mm Plain AluminumFin spacing -_ 12 FPICondensing tray -_ 20G SS 304Test Pressure—38 Kg/Sq.cm.Insulation Material for Drain Tray -_ Min.13mm thick close cellNitrile Rubber`Pre Filters (EU-4) Efficiency :- 90% down to 10 microns`FAN Type -_ DIDW Backward/FORWARD curved/Plug fan(Make -_ NICOTRA/KRUGER or Equivlent) `(Inside Design Conditions: 24º ±2ºC: RH: Not exceeding 60%:Filteration:10µ: complete with fire retardant and water proof double flexible connection between fan outlet and duct.The capacity of Air-handlers shall be as follows:9000 CFM ( 35 TR min)-FM ,80 MM STATIC PR.,6 RD C.C. Outdoor Type |
| 69 | SITC of DOUBLE SKIN AIR HANDLING UNIS DX TYPE (AHRI CERTIFIED) COMPLETE IN ALL RESPECT (Outdoor/IndoorType)`- Mixing box with manually operated Aluminium Anodised Extruded dampers at fresh and return air cutouts.- Filter section with 50 mm thick box type pre filter on frame.- Coil section with multi-rows deep (6RD) DX cooling coils compatiable with VRV/VRF Outdoor unit.- Fan section with imported DIDW centrifugal backward/Backward curved fan, motor, V-belt and drive set. -Fresh Air Cut out , light in AHU TF Canvass Connection etc.`Following Min.specifications shall be adhered for AHU :`AHU PANELSOuter Skin -_ 0.8 mm pre-coated GIInner Skin -0.8 mm pre-coated GIThickness – Min48±2 mm thick: CFC free PUF injected(Density: Min 48± 2 kg/ Cu. m.)`Unit Base -_ Heavy Duty G.S.S. Profile -_ Thermal Break Aluminum Profile`COOLING COIL : Coil section with multi-rows deep suitable for R410 A Refrigerant type cooling coil.Tube Material -_ CopperTube Thickness—0.5 mm min or as per OEM recomendationHeader material –CU (for DX)Coil Casing -_ G.IFin Thickness and Material – 0.15mm Plain AluminumFin spacing -_ 12 FPICondensing tray -_ 20G SS 304Test Pressure—38 Kg/Sq.cm.Insulation Material for Drain Tray -_ Min.13mm thick close cellNitrile Rubber`Pre Filters (EU-4) Efficiency :- 90% down to 10 microns`FAN Type -_ DIDW Backward/FORWARD curved/Plug fan(Make -_ NICOTRA/KRUGER or Equivlent) `(Inside Design Conditions: 24º ±2ºC: RH: Not exceeding 60%:Filteration:10µ: complete with fire retardant and water proof double flexible connection between fan outlet and duct.The capacity of Air-handlers shall be as follows:3000 CFM ( 8 TR min)-FM ,70 MM STATIC PR.,6 RD C.C. Outdoor Type |
| 70 | SITC of DOUBLE SKIN AIR HANDLING UNIS DX TYPE (AHRI CERTIFIED) COMPLETE IN ALL RESPECT (IndoorType)`- Mixing box with manually operated Aluminium Anodised Extruded dampers at fresh and return air cutouts.- Filter section with 50 mm thick box type pre filter on frame.- Coil section with multi-rows deep (6RD) DX cooling coils )compatiable with VRV/VRF Outdoor unit.- Fan section with imported DIDW centrifugal backward/Backward curved fan, motor, V-belt and drive set. -Fresh Air Cut out , light in AHU ,TF Canvass Connection etc.`Following Min.specifications shall be adhered for AHU :`AHU PANELSOuter Skin -_ 0.6 mm pre-coated GIInner Skin -0.6 mm pre-coated GIThickness – Min48±2 mm thick: CFC free PUF injected(Density: Min 48± 2 kg/ Cu. m.)`Unit Base -_ Heavy Duty G.S.S. Profile -_ Thermal Break Aluminum Profile`COOLING COIL : Coil section with multi-rows deep suitable for R410 A Refrigerant type cooling coil.Tube Material -_ CopperTube Thickness—0.5 mm min or as per OEM recomendationHeader material –CU (for DX)Coil Casing -_ G.IFin Thickness and Material – 0.15mm Plain AluminumFin spacing -_ 12 FPICondensing tray -_ 20G SS 304Test Pressure—38 Kg/Sq.cm.Insulation Material for Drain Tray -_ Min.13mm thick close cellNitrile Rubber`Pre Filters (EU-4) Efficiency :- 90% down to 10 microns`FAN Type -_ DIDW Backward/FORWARD curved/Plug fan(Make -_ NICOTRA/KRUGER or Equivlent) `(Inside Design Conditions: 23º ±2ºC: RH: Not exceeding 60%:Filteration:10µ: complete with fire retardant and water proof double flexible connection between fan outlet and duct.The capacity of Air-handlers shall be as follows:3200 CFM ( 8 TR min)-CS ,55 MM STATIC PR.,6 RD C.C. |
| 71 | Smart PIR (Polyisocyanurate)DuctingSupply and Installation of Factory Pre-cut made of Pre-Insulated SMART PIR Panels, complete CFC,HCFC, HFC free, with both sides surfaces as mentioned below(with anti-microbial, anti-fungal, anti-corrosion, and UV protection coating). The panels must consist of closed-cell, rigid cellular PIR foam insulation with no less than 93% insulation thickness as specified, and the material shall have COC(TUV) for Class O from any global lab and should complied as per BS 476 Part 6 and Part 7 , and having Density of 45( plus -3)kg/m3 and should have Thermal Conductivity 0.023 W/mK , Water absorption shall be not more than 0.03% as per EN 13403 standard and panel should be GreenPro, GRIHA, SGBC and EPD certified. The ductwork should be capable of handling pressures upto 2000 Pascals. The joint between the ducts shall be with polymer slide in type joints with Bayonet or with Male-Female joint as per SMACNA between the ducts for negligible lekages. All polymer accessories to be of the same manufacturer and adhesive should be of greenpro certifed pidilite make. Supporting of Threaded Rod (6mm) and C Channel /Wires of reputed make recommended by Manufacturer to be provided. Duct measurement should be taken outer to outer. Manufacture should have minimum 12 plus years of experience in manufacturing of same product in India.For Internal Ducting - 20MM Thick Panels with 45 Micron Embossed Aluminium on one side and 80 Micron Embossed Aluminium on the other sides. |
| 72 | MECHANICAL INSULATIONDUCT LINE ACOUSTIC TREATMENTSupply, Installation, Testing and Commissioning of Acoustic lining inside ducts/plenum using open cell nitrile rubber foam having microban anti-microbial/ anti fungal product protection and of 160-180 kg / m³ density as per ASTM D3575, class 1 ratingn As per BS476,PART-7, cut to required sizes and to be stuck to the inside of duct surfaces with adhesive as approved by the manufacturer. (Rubber based solvent). as per specifications 15mm thick sound board for Floor Mounted AHU |
| 73 | MECHANICAL INSULATIONDUCT LINE ACOUSTIC TREATMENTSupply, Installation, Testing and Commissioning of Acoustic lining inside ducts/plenum using open cell nitrile rubber foam having microban anti-microbial/ anti fungal product protection and of 160-180 kg / m³ density as per ASTM D3575, class 1 ratingn As per BS476,PART-7, cut to required sizes and to be stuck to the inside of duct surfaces with adhesive as approved by the manufacturer. (Rubber based solvent). as per specifications 10mm thick sound board for CS AHU/VRF Ductable Acs |
| 74 | DUCT LINE THERMAL INSULATION (Inside Conditions)SITC of Physically / Chemically crosslinked polyethylene foam, with factory reinforced alupet foil facing, ANTI MICROBIAL/ANTI FUNGAL,HFC and CFC free , Negligible VOC level with Class O fire properties,with very low fire propagation of ( 5.5 and passing E-84 at ( 25/50, as per technical specification, the density of the foam should be not less than 25-30kg/m3 and the maximum thermal conductivity K should be 0.032W/mK@ 23 Deg C , the permeability resistance factor u shouldn`t be less than 14000. The product shall have temperature range of –20oC to 115oC 13 mm thick |
| 75 | DUCT LINE THERMAL INSULATION (Outside Conditions exposed to sun)Physically / Chemically crosslinked polyethylene foam, with factory laminated heavy duty and ultra tough multi-layered composite aluminium foil facing, with puncture resistance of )400N and Class O fire properties as per BS 476 Part BS 476 Part 6 and 7 and as per the tender technical specification and density of the foam should be not less than 25 - 30 kg/m3 and maximum thermal thermal conductivity K should be 0.032W/mK@ 23 Deg C and the permeability resistance factor u shouldn`t be less than 97000. 25mm thick |
| 76 | Condensate Drain Piping:Providing and Fixing of CPVC 10 kg/cm2 pipes of various sizes including all fittings for condensed water drainage from Indoor unit to nearest disposal point in toilet/ outside rain water harvesting system as approved by architect/Engineer-In-Charge, 25 mm with 6 mm nitrile insulation. |
| 77 | Condensate Drain Piping:Providing and Fixing of CPVC 10 kg/cm2 pipes of various sizes including all fittings for condensed water drainage from Indoor unit to nearest disposal point in toilet/ outside rain water harvesting system as approved by architect/Engineer-In-Charge, 32 mm with 6 mm nitrile insulation. |
| 78 | Condensate Drain Piping:Providing and Fixing of CPVC 10 kg/cm2 pipes of various sizes including all fittings for condensed water drainage from Indoor unit to nearest disposal point in toilet/ outside rain water harvesting system as approved by architect/Engineer-In-Charge, 40 mm with 6 mm nitrile insulation. |
| 79 | Fresh Air/Exhaust Air Louvers Supply, Installation, Testing and Commissioning of extruded aluminium louvres with frame bird screeen 50 mm pre-filter with frame, mounting arrangement etc. as per specifications and drawings. Fresh Air/Exhaust Louvers |
| 80 | Jet DiffuserSupplying, fixing testing commissioning of Supply Nozzel Eyel Type Jet Diffusers of powder coated aluminium, laying and Jointing complete in all respect.of following diaMin Neck size of 315 mm dia |
| 81 | Power Cabling and Earthing`Supply, installation, testing and commisioning of Aluminum/Copper conductor cables PVC sheathed, armoured cables of 1.1 KV grade with termination glands and GI earthing, identification tags, clamps and saddles etc.`3.5Cx300 Sqmm Al.Armoured |
| 82 | Power Cabling and Earthing`Supply, installation, testing and commisioning of Aluminum/Copper conductor cables PVC sheathed, armoured cables of 1.1 KV grade with termination glands and GI earthing, identification tags, clamps and saddles etc.`4.0Cx4 Sqmm Copper Armoured |
| 83 | Power Cabling and Earthing`Supply, installation, testing and commisioning of Aluminum/Copper conductor cables PVC sheathed, armoured cables of 1.1 KV grade with termination glands and GI earthing, identification tags, clamps and saddles etc.`4.0Cx2.5 Sqmm Copper Armoured |
| 84 | Power Cabling and Earthing`Supply, installation, testing and commisioning of Aluminum/Copper conductor cables PVC sheathed, armoured cables of 1.1 KV grade with termination glands and GI earthing, identification tags, clamps and saddles etc.`4Cx2.5 Sqmm (flexible Cu Conductor) |
| 85 | Control Cabling Providing and fixing screened control cum transmission wiring of 2 core x 1.5 mm shielded copper in suitable conduits to be placed on cable tray between indoor and out door unit and indoor unit and its remote controller and all other control wiring required for the full functioning of the HAVC system and its controls and BMS centralized controller. All HVAC piping , drainage and Cabling etc shall run at a height of 6 inches below RCC slab on continuous cable tray of appropriate sizes. all beams/slab shall be core cut to allow for passage of pipes etc and filled back with expanded polyurethene foam. rates quoted are inclusive of core cutting and cable tray etc complate in all all respects including painting in desired colour. |
| 86 | MCB DB BoxesSITC of MCB DB Box with MCB DP `c` curve of 6-16 Amps as per rating of the Indoor unit of respective VRV/VRF unit with all accessories like ,etc. complete in all respect . |
| 87 | Main Electrical Panel (CPRI Approved) for VRV/VRF SystemSupply,Installation,Testing and Commissioning Electrical Main Panel weather Proof Outdoor Type Powder Coated Made out of TATA/SAIL/ESSAR/JINDAL/Reputed make sheet having thickness 2.0 mm for load bearing surfaces and 1.6 mm Non bearing surfaces duly processsed powder coated having Siemens grey colour or as approved by client or department (Outdoor Type with weatherproof canopy design)as per following specifications complete in all respect . Note : Manufacturer should have atleast CPRI Approval of 70 KINCOMING SUPPLY 630-800Amps ,3Pole MCCB,65 KA with TMD release with 100% ICU =ICS 1nos Make : Schneider/ Siemens/ABBSpreader Link with phase Barriers = 1sets Make : Schneider/ Siemens/ABB Rotary Mechanism = 1nos Make : Schneider/ Siemens/ABBMetering SectionLoad Manager EM6400NG with RS485 Port or Equivalent (Class 1.0, with RS485 Port, with Paramenters V, Amp, PF, % THD, F,W,WH,VA,VAH, VAR,VARH, Runhrs, ON hrs, Interupts = 1No. Make: Schnieder/Elmeasure/Siemens/Secure/SelecControl MCB SP C Curve= 3nos Make : Schneider/ Siemens/ABBCT`s 800/5 = 3nos Make: AE/Essma/Newtek/Selec/NippenIndication Lamps LED Type RYB = 3nos Make : ABB/ Schneider/ Siemens/LandT/Reputed Outgoing Feeder upto 12/10 HP VRV/VRF Units - 32 nos (27W plus 5S)32-63Amps 3 Pole MCCB,36 KA with Thermal magenetic release adjustable type.The MCCB shall be double break and the 100% ICU =ICS Qty 32nos (for VRV unit Various HP combination) Make : Schneider/ Siemens/ABBSpreader Link with phase Barriers = 32 sets Make : Schneider/Siemens/ABB Rotary Mechanism = 32nos Make : Schneider/ Siemens/ABBINDICATING LAMPS LED Type -32 sets Make : ABB/ Schneider/ Siemens/LandTControl MCB SP C Curve for control Make : Schneider/ Siemens/ABBMCB TPN plus ELCB of the same rating ( 300 MA or suitable) as outgoings as per the combination of machine (Example, if in a section of 36 HP ODU, a Set of 1 nos 36 HP ODU each is taken then MCB TPN and ELCB 63 Amps 300MA or suitable each to be provided as O/G or in case of 12HP ODU`s (i.e 12 x 3nos) combination the 3 nos MCB TPN 32 Amps with ELCB of 32 Amps/ 300MA each to be provided for the combination or in any other combination the MCB TPN and ELCB to be provided as per requirment for each machine)PanelFabrication of Powder Coated Enclosure made out of TATA/SAIL/ESSAAR/JINDAL/Reputed make CRCA sheet having 2 mm for load bearing surfaces and 1.6 mm for non load bearing surfaces ,duly processsed powder coated having Siemens grey colour. (Outdoor Type with weatherproof canopy design)Assembly charges of Aluminium Bus Bar 800- 1000A TPN Electrolite grade E91 having suitable cross section for Neutral and Current carring capacity 1 A/Sq. mm2. inclusive of Insulators, colour coded Heat shrinkable Insulation sleeve (RYBN)Assembly of Hardware (PVC Channels/MCB Channels/Fibre-Glass/Gaskits/nuts/Bolts/washers/ Terminal blocks, etc)Complete Wiring inclusive of control wiring, power wiring, Aluminium Solid connections/interconnections including insulators, thimbles,etcUnloading at site, placement of Panel on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned Panel. |
| 88 | AHU Panels for upto 7.5 KW DOL/Star Delta type StarterSITC of AHU panels duly powder coated wall mounted Made out of TATA/SAIL/ESSAR/JINDAL/Reputed make CRCA Sheet of 1.6 mm thick consisting of Upto incomer as MPCB suitable as per AHU ON/OFF/TRIP indication light LED type, DIGITAL Ammeter with ASS: CT`s 30/5: contactors up to32A or Suitable (with 2 NO plus 2NC): Start/Stop push buttons with auto and Manual control switch, Single Phase Preventer, MCB DP upto 10 Amps C Curve ,Over load Relay 16-25A or Equivalent Suitable , power and control terminals: neutral link and internal wiring and connections for motors upto 10 HP or Suitable |
| 89 | SITC of Starter Panels- Supply /Exhaust Air Blower up to 11 KW or suitable)01 No. - 0-40 A TP MCB with Conforming to BIS 25 A DOL starter, overload relay, start/stop push buttons, ammeter (0-63A) on / off / trip indication lights with protection fuse, single phase preventerControl panel must have MCB TPN, on off push button, on/off/trip indicators, potential free contacts for Fire Alarm for operation of the starter in case of fire, manual reset overload relays, earthing and armoured fire proof cabling from starter panel to fan motor with proper tray supports and BMS compatible. Starter panel with auto manual toggle switch,Timer based and facility to operate on remote signal from smoke control panel .Unloading at site, placement of Panel on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned Panel. |
| 90 | Ventilation for Smoke ExtractionS/I/T/C of LONG CASED TUBE/ VANE AXIAL FAN WITH IE3 MOTOR FOR MULTIPURPOSE HALLSupply, installation, testing and commissioning of Direct drive Long cased Tube/ VANE Axial fans complete with Hot dipped Galvanised Steel /Pre Galaavanised Steel Casing with spun flanges, adjustable pitch die cast aluminium impeller (Hub and Aerofoil blades) and IE3 motors. Casing position shall be as per the job requirement and shall be marked on the fan assembly.The complete fan assembly with its casing, impeller and motor ( not only motor or one of the item ) shall be sourced from one manufacturer and 300 degree C for 2 Hrs operation.The complete assembly must have certificate of consistency of performance by BSI .Motor Shall be suitable for 415 volts ± 10%, 50Hz ± 3 %, three phase A.C complete with starter having overload and single phase protection, support, mountings, vibration isolators, fire retardant flexible canvass connector 150 mm deep (Inlet and Outlet as required), bird screen (Inlet and Outlet as required), Including cost of Back draft Damper,Exhaust Louvers , Fan must be licensed to bear AMCA seal for air performance and sound performance ad the claimed air and sound performance must be demonstrated in AMCA accredited laboratory as per AMCA publication 211 and 311`Supply, installing, testing and commissioning of Single speed Long cased VANE Axial Fans of capacity 21000cfm @ 25 mm Static (for normalmode) Fans should be suitable for emergency mode operation (300 Deg / 2 Hrs) ` |
| 91 | Supply, Installation, Testing and Commissioning of 5MP IP WDR IR Rugged Mini Dome Camera,Operational Video Standard NTSC/PAL, Scanning System: Progressive, Image Sensor : 1/2.7” Progressive CMOS, Number Of Pixels (H × V) : 2560(H) x 1920(V), Minimum Illumination : 0.03 lux color @ F2.0, 0 lux B/W with IR LEDs on @ F2.0, S/N Ratio ) 55 dB, Electronic Shutter Speed 1/5 ~ 1/32,000, IR Distance: Distance up to 30m (98ft), IR Light Control: Smart IR (Auto/Manual)/OFF, IR Light Number 2, Day/Night: Auto/Day/Night/Schedule, Backlight Compensation: WDR, HLC, White Balance: Auto/Fixed Current/Manual, Gain Control: 0-100%, Wide Dynamic Range: 120dB, Noise Reduction 3D DNR, Privacy Masking: Off / On (5 Areas), Motion Detection: Motion/Intrusion/People detection, Tampering Detection: Tampering Detection/Image too dark detection/Image too bright detection/Image too blurry detection, Region Of Interest Support, Lens 2.8mm, Fixed, F2.0, Angle Of View : H:103°, V:76° @5M, Video Compression H.265/H.264/Smart Codec/MJPEG, Resolution (5MP): 2560x1920/2048x1536/ 1600x1200/1280x960/800x600/640x480: Frame Rate Main Stream: 5M/4M (1 ~ 25/30fps):*Up to 30fps @5M under H.265 onlySub Stream: 800x600 (1 ~ 25/30fps):Third Stream: VGA (1 ~ 25/30fps), Bit Rate Control: Constrained bit rate/Fixed quality, Bit Rate 20K ~ 40Mbps, NETWORK: Ethernet 10 Base-T/100 Base-TX Ethernet (RJ-45), Supported Web Browsers Chrome 71 plus , Internet Explorer 11.0 plus Supported OS Microsoft windows 7/10, Protocols* IPv4, IPv6, TCP/IP, HTTP, HTTPS, UPnP, TSP/RTP/RTCP, IGMP, SMTP, DHCP, NTP, DNS, DDNS, CoS, QoS, SNMP, 802.1X, UDP, ICMP, ARP, TLS, Interoperability ONVIF Profile G/S, Maximum Users Access 10 Users, approved make should have honeywell, axis, bosch Security User account and password protection, HTTPS, IP Filter,Digest authentication, TLS1.2 only, Stream encryption, AES-128/256, SSH/Telnet closed, PCIDSS ,NDAA compliance, Event: Event notification using HTTP, SMTP, NAS server and MicroSD cardFile upload via HTTP, SMTP, NAS server and MicroSD card, Micro SD/SDHC/SDXC card slot (256GB): ELECTRICAL Power Supply DC12V, PoE (IEEE 802.3af) (Class 2), Power Consumption MAX 6.49W, MECHANICAL: Dimensions Ø117.11mm x 89.51mm (Ø4.61’’ x3.52’’), Product Weight 0.54kg, Package Weight 0.88kg, Material Die-casting aluminum housing with coating, Construction Color RAL 120-1 (Lyric White), ENVIRONMENTAL: Operating Temperature Starting: -10°C ~ 60°C (14°F ~ 140°F)Working: -30°C ~ 60°C (-22°F ~ 140°F), Relative Humidity Less than 90%, non-condensing, Ingress Protection IP66, Vandal Resistance IK10, REGULATORY: Emissions FCC PART 15B, EN 55032, EN61000-6-3, Immunity EN 50130-4, Safety UL 62368-1, EN 62368-1 ROHS, EN 50581 Complete in all respect to the entire satisfaction of the engineer-in-charge . complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 92 | Supply, Installation, Testing and Commissioning of 5MP IP WDR IR Bullet Camera OPERATIONAL Video Standard NTSC/PAL Scanning System: Progressive, Image Sensor: 1/2.7” Progressive CMOS, Number Of Pixels (H × V): 2560(H) x 1920(V), Minimum Illumination: 0.03 lux color @ F2.0, 0 lux B/W with IR LEDs on @ F2.0, S/N Ratio: ) 55 dB, Electronic Shutter Speed: 1/5 ~ 1/32,000, IR Distance: Distance up to 50m(165ft), IR Light Control: Smart IR (Auto/Manual)/OFF, IR Light Number 2, Day/Night: Auto/Day/Night/Schedule, Backlight Compensation WDR, HLC, White Balance: Auto/Fixed Current/Manual, Gain Control 0-100%, Wide Dynamic Range 120dB, Noise Reduction 3D DNR, Privacy Masking Off / On (5 Areas), Motion Detection: Motion/Intrusion/People detection, Tampering Detection: Tampering Detection/Image too dark detection/Image too bright detection/ Image too blurry detection, Region Of Interest Support,Lens: 4.0mm, Fixed, F2.0 Angle Of View: H:78°, V:59° @5M, Video Compression H.265/H.264/Smart Codec/MJPEG, Resolution 2560x1920/2048x1536/ 1600x1200/1280x960/800x- 600/640x480: Frame Rate: Main Stream: 5M/4M (1 ~ 25/30fps): *Up to 30fps @5M under H.265 only Sub Stream: 800x600 (1 ~ 25/30fps): Third Stream: VGA (1 ~ 25/30fps), Bit Rate Control: Constrained bit rate/Fixed quality, Bit Rate 20K ~ 40Mbps Ethernet 10 Base-T/100 Base-TX Ethernet (RJ-45), Supported Web Browsers Chrome 71 plus , Internet Explorer 11.0 plus , Supported OS Microsoft Windows 7/10, Protocols* IPv4, IPv6, TCP/IP, HTTP, HTTPS, UPnP, RTSP/RTP/RTCP, IGMP, SMTP, DHCP, NTP, DNS, DDNS, CoS, QoS, SNMP, 802.1X, UDP, ICMP, ARP, TLS, Interoperability ONVIF Profile G/S, Maximum Users Access: 10 Users, approved make should have honeywell, axis, bosch Security User account and password protection, HTTPS, IP Filter, Digest authentication, TLS1.2 only, Stream encryption, AES- 128/256, SSH/ Telnet closed, PCIDSS,NDAA compliance, Event notification using HTTP, SMTP, NAS server and MicroSD card File upload via HTTP, SMTP, NAS server and MicroSD card ,Micro SD: Micro SD/SDHC/SDXC card slot (256GB Power Supply DC12V, PoE (IEEE 802.3af) (Class 2) Power Consumption MAX 6.49W, Dimensions ø91.1mm x 177mm (ø3.59” x 6.97’’), Product Weight 0.53kg, Package Weight 0.74kg, Material Die-casting aluminum housing with coating, Construction Color RAL 120-1 (Lyric White), Operating Temperature Starting: -10°C ~ 60°C (14°F ~ 140°F) Working: -30°C ~ 60°C (-22°F ~ 140°F), Relative Humidity Less than 90%, non-condensing, Ingress Protection IP66, Emissions FCC PART 15B, EN 55032, EN61000-6-3, Immunity EN 50130-4, Safety UL 62368-1, EN 62368-1, ROHS EN 50581 Complete in all respect to the entire satisfaction of the engineer-in-charge . complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 93 | Supply, Installation, Testing and Commissioning of 64 Channel Network Video Recorder and Management System with required Licenses for all of the above mentioned Complined Cameras complete with all necessary required software`s, Hardware`s, Storage, Accessories, Civil, Electrical works and peripheral items required as per specifications and at site of work inline with the engineer in charge instructions. The system proposed should have minimum usable 30 days recording suitable Hard Disk as per requirement with 256MBPS throughput. Should support 10 SATA of 10 TB each With RAID 5/6. Certifications: ONVIF Profile S Compliant, UL, CE, Compliant.complete in all respects as approved and desired by the Engineer-in-charge at site. . |
| 94 | Supply, Installation, Testing and Commissioning of 10TB Hard disk Surveillance complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 95 | Supply, Installation, Testing and Commissioning of 43 ` LED Full HD TV Resolution 1920 x 1080 ,Contrast Ratio (Typical) 5000:1,Built-in Speaker (10W plus 10W) Complete in all respect to the entire satisfaction of the engineer-in-charge .. |
| 96 | Supply, Erection, Testing and commissioning of 24 port 10/100/1000Base-T with 4 10G SFP plus and 2 10G Base-T L2 plus Managed Switch, Switching Capacity 168 Gbps : 125 Mpps Forwarding Rate,Redundant Power Supply Support, Console Port,Management Port,USB 2.0 Port,9 Unit Stack Support,32 Unit SIM,ERPS,32Group LACP,Loopback Detection,Root Restriction,1024 Multicast Groups.Port-based VLAN,802.1v Protocol VLAN,Voice VLAN,MAC-based VLAN,VLAN translation,ISM VLAN,Asymmetric VLAN, Private VLAN,VLAN Trunking,Super VLAN,Port Security, Broadcast/ Multicast/Unicast Storm Control,DHCP Server Screening,ARP Spoofing Prevention,VRRP,DoS Attack Prevention,BPDU Attack Protection,RADIUS and TACACS plus authentication,Compliant with RoHS,Power saving ,IEEE 802.3az,Cable diagnostics, 802.3ah. SNMP v1/v2c/v3,System Log,sFlow,Multiple images,Multiple Configurations. VRRP,RIPv1/v2/ng,Static Routing-512 IPv4 entries,OSPF, IGMP Filtering ,6 kV surge protection on all Gigabit Ethernet ports.UL,CE,FCC. All Switches,,Wireless and its and Networkiing Components from Same OEM. Complete in all respect to the entire satisfaction of the engineer-in-charge . |
| 97 | `Supply, installation, testing and commissioning of 24 port, modular design, loaded Patch Panel 4X6 TYPE, populates up to 24 UTP keystone-type jacks in 1U,Enhanced with cable strain relief with retention tray, combination of high grade plastic and CRS metal,Standard : Conforms to IEC-60603-7 (603-7) for keystone-type, snap-on apertures, RoHS complied, compatiable with Cat 5, Cat 6 and Cat 6A UTP Keystone Jack,Compatible with RJ standard plugs (RJ11, RJ12, RJ45), PCB and with tool Less connection of installation cables AWG 24 – 22 (0.5 mm – 0.65 mm) and flexible cables AWG 26/7 – AWG 22/7.,Termination should feature nil crossover in acc. with EIA/TIA 568-A/B, gold-plated 50micron bronze contacts for )750 mating cycles, )200 insertion cycle,Connector should be 50micron gold-plated and supplied with stain relief cap on back side of Jack,Housing material: Polycarbonate (UL-94-V0) Complete in all respect to the entire satisfaction of the engineer-in-charge . ` |
| 98 | Supply, installation, testing and Commissioning of Category 6, 1 Meter UTP patch cords shall be constructed of 24 AWG,Number of conductors : 8 ,Cable jacket characteristics: cable, metal-free,Cable overall diameter: 6.0±0.2 mm, Tube / Wire type: stranded conductor, Plug: Feature cable retension, with enhanced pull strength.,Cat 6 patch cord plug to have round cable holder and strain relief snagless boot to avoid bending,Jacket: PVC / LSZH with different color and Size options, Plug should have high repeatability cross talk performance with 50micron gold plating connector plug, Patch cord connector should be 50 micron gold plating plug, Standardization: Compliant with Cat.6, Class E requirements: ISO/IEC 11801 2nd Edition Compliant with Cat.6 component standards IEC 60603-7-4 and 60603-7-5 . Complete in all respect to the entire satisfaction of the engineer-in-charge . |
| 99 | Supply, installation, testing and Commissioning of Category 6, 2 Meter UTP patch cords shall be constructed of 24 AWG,Number of conductors : 8 ,Cable jacket characteristics: cable, metal-free,Cable overall diameter: 6.0±0.2 mm, Tube / Wire type: stranded conductor, Plug: Feature cable retension, with enhanced pull strength.,Cat 6 patch cord plug to have round cable holder and strain relief snagless boot to avoid bending,Jacket: PVC / LSZH with different color and Size options, Plug should have high repeatability cross talk performance with 50micron gold plating connector plug, Patch cord connector should be 50 micron gold plating plug, Standardization: Compliant with Cat.6, Class E requirements: ISO/IEC 11801 2nd Edition Compliant with Cat.6 component standards IEC 60603-7-4 and 60603-7-5 . Complete in all respect to the entire satisfaction of the engineer-in-charge . |
| 100 | Supply, Installation, Testing and Commissioning of HDMI Cable 10 Mtr Complete in all respect to the entire satisfaction of the engineer-in-charge . |
| 101 | Supply, Erection, Testing and commissioning of 24 Port Non-PoE Switch-Switch should have total 28 Nos. Gigabit port including 24 Nos. of 10/100/1000 Mbps Ethernet PoE Ports and 4 Nos of 1G SFP Combo, The switch should be flexible enough to be managed through cloud and standalone mode. The cloud management should be free of cost The Switch should have Non-blocking wire speed switch fabric, should have Min. 56 Gbps Back plane or more and should have Min. 41 Mpps or more, 375W or more PoE budget, 16K MAC address, IPv6 Support, CE-LVD ,FCC, CE ,BSMI , RoHS Compliant, Operating temperature 0 DegC to 50 Deg C, The OEM should be having valid ISO 9001, ISO 14001, ISO 45001:2018 . Complete in all respect to the entire satisfaction of the engineer-in-charge . |
| 102 | `Supply, installation, testing and commissioning of 24 port, modular design, loaded Patch Panel 4X6 TYPE, populates up to 24 UTP keystone-type jacks in 1U,Enhanced with cable strain relief with retention tray, combination of high grade plastic and CRS metal,Standard : Conforms to IEC-60603-7 (603-7) for keystone-type, snap-on apertures, RoHS complied, compatiable with Cat 5, Cat 6 and Cat 6A UTP Keystone Jack,Compatible with RJ standard plugs (RJ11, RJ12, RJ45), PCB and with tool Less connection of installation cables AWG 24 – 22 (0.5 mm – 0.65 mm) and flexible cables AWG 26/7 – AWG 22/7.,Termination should feature nil crossover in acc. with EIA/TIA 568-A/B, gold-plated 50micron bronze contacts for )750 mating cycles, )200 insertion cycle,Connector should be 50micron gold-plated and supplied with stain relief cap on back side of Jack,Housing material: Polycarbonate (UL-94-V0) Complete in all respect to the entire satisfaction of the engineer-in-charg |
| 103 | Supply, installation, testing and Commissioning of Category 6, 1 Meter UTP patch cords shall be constructed of 24 AWG,Number of conductors : 8 ,Cable jacket characteristics: cable, metal-free,Cable overall diameter: 6.0±0.2 mm, Tube / Wire type: stranded conductor, Plug: Feature cable retension, with enhanced pull strength.,Cat 6 patch cord plug to have round cable holder and strain relief snagless boot to avoid bending,Jacket: PVC / LSZH with different color and Size options, Plug should have high repeatability cross talk performance with 50micron gold plating connector plug, Patch cord connector should be 50 micron gold plating plug, Standardization: Compliant with Cat.6, Class E requirements: ISO/IEC 11801 2nd Edition Compliant with Cat.6 component standards IEC 60603-7-4 and 60603-7-5 . Complete in all respect to the entire satisfaction of the engineer-in-charg |
| 104 | Supply, installation, testing and Commissioning of Category 6, 2 Meter UTP patch cords shall be constructed of 24 AWG,Number of conductors : 8 ,Cable jacket characteristics: cable, metal-free,Cable overall diameter: 6.0±0.2 mm, Tube / Wire type: stranded conductor, Plug: Feature cable retension, with enhanced pull strength.,Cat 6 patch cord plug to have round cable holder and strain relief snagless boot to avoid bending,Jacket: PVC / LSZH with different color and Size options, Plug should have high repeatability cross talk performance with 50micron gold plating connector plug, Patch cord connector should be 50 micron gold plating plug, Standardization: Compliant with Cat.6, Class E requirements: ISO/IEC 11801 2nd Edition Compliant with Cat.6 component standards IEC 60603-7-4 and 60603-7-5 . Complete in all respect to the entire satisfaction of the engineer-in-charg |
| 105 | Supply, installation, testing and Commissioning of Wall Mounted Rack network Rack - 15U 500d, with Heavy Duty Extruded Aluminium Frame for rigidity. Fan 90CFM 230V AC, Cable manager 1U MS with Loops Shelf, PDU 6 Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Complete in all respect to the entire satisfaction of the engineer-in-charge. |
| 106 | `Supply, Installation, Testing and commissioning of 1 KVA Online UPS 36VDC with In- Built 3 No. Batteries Pure Sine wave with following features:-OVCD, Wide input range, Programmable output range 208V/220V/230V/240V, 12V x 7Ah x 3 No. SMF batteries in-built, Output Power Factor 0.9, 0ms Transfer time from Inverter Mode to Battery Mode ,Charger Current 1.5 Amp, Cooling Fan, True Online Double Conversion, Inbuilt Over-voltage Cut-off Device, Inbuilt Over Temperature Protection, Surge Protection, Better Overload Protection upto 105% Constant, Higher Efficiency up-to 92% in ECO Mode, 2 year onsite warranty on UPS with 30 plus minutes Back up time on switches load complete in all respects as approved and desired by the Engineer-in-charge at sit |
| 107 | [10.1]Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. [Through Rate] |
| 108 | [10.10.1]Providing and laying Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 1. 40 mm thick with 20 mm nominal size stone aggregate [Through Rate] |
| 109 | [10.14]Providing a floating coat of 1.50 mm thick neat cement laid in one operation to the topping. [Through Rate] |
| 110 | [10.18]Extra for making chequers (2mm deep) of approved pattern on cement concrete floors, steps, landing, pavements etc. [Through Rate] |
| 111 | [10.2]Supplying and filling in plinth with sand (conforming to zone-IV, IS 1542) under floors, including watering, ramming, consolidating and dressing complete. [Through Rate] |
| 112 | [10.30.1]Providing and laying of chequered precast cement concrete tiles 22 mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 1. Light shade pigment using white cement [Through Rate] |
| 113 | [10.30.2]Providing and laying of chequered precast cement concrete tiles 22 mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 2. Medium shade pigment using 50% white cement 50% Grey cement [Through Rate] |
| 114 | [10.4]Providing and laying of screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. [Through Rate] |
| 115 | [10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate] |
| 116 | [10.60]Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [Through Rate] |
| 117 | [10.62]Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. [Through Rate] |
| 118 | [10.63.2]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. Size of Tile 600x600 mm [Through Rate] |
| 119 | [10.67.2]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 2. Size of Tile 600x600 mm [Through Rate] |
| 120 | [10.70.2]Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 2. Size of Tile 600x600 mm [Through Rate] |
| 121 | [11.1.1]6 mm cement plaster of mix : 1. 1:3 (1 cement : 3 fine sand) [Through Rate] |
| 122 | [11.121]Polyurethane polish (PU) two or more coats to give required finish including two coat of wood sealer Including Preparation of surface/base complete as per specification [Through Rate] |
| 123 | [11.17]Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge [Through Rate] |
| 124 | [11.4.2]10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) [Through Rate] |
| 125 | [11.5.1]12 mm cement plaster of mix : 1. 1:2 (1 cement: 2 fine sand) [Through Rate] |
| 126 | [11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate] |
| 127 | [11.52]Cement rendering on plaster 1 mm thick [Through Rate] |
| 128 | [11.59]Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. [Through Rate] |
| 129 | [11.6.1]15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) [Through Rate] |
| 130 | [11.6.2]15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) [Through Rate] |
| 131 | [11.60]Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. [Through Rate] |
| 132 | [11.65.1]Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer`s specification. 1. Two or more coats on new work [Through Rate] |
| 133 | [11.68.3]Applying priming coat: 3. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works [Through Rate] |
| 134 | [11.7.1]20 mm cement plaster of mix : 1. 1:4 (1 cement: 4 fine sand) [Through Rate] |
| 135 | [11.74.2]Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 2. Two coats [Through Rate] |
| 136 | [11.75.2]Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2. Two coats [Through Rate] |
| 137 | [11.77]Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. [Through Rate] |
| 138 | [11.8.1]12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand) [Through Rate] |
| 139 | [11.82.1]Painting the wooden / metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new work [Through Rate] |
| 140 | [11.94.1]Finishing walls with textured exterior paint of required shade : 1. New work (Two or more coats applied @ 3.28 litre/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm [Through Rate] |
| 141 | [11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) [Through Rate] |
| 142 | [12.10.1.1]Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 1.1. Second class teak wood 35 mm thick [Through Rate] |
| 143 | [12.146.3.1]Providing and fixing, in position concealed G.I. section for wall panelling using board of required thickness fixed on the `W` profile (0.55 mm thick) having a knurled web of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm, placed @ 610 mm C/C in perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of 0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @ 610 mm C/C with fully threaded self-tapping dry wall screws. Board is fixed to the `W` profile with 25 mm countersunk ribbed head screws @ 200 mm C/C., all complete as per the drawing and directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish. 3.1. Plain Gypsum plaster board conforming to IS: 2095 Part -1:2011 (Board with BIS certification marks) 12.5 mm thick [Through Rate] |
| 144 | [12.19.1.1.1]Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 1.1.1. 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Second class teak wood [Through Rate] |
| 145 | [12.19.2.1.2]Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 2.1.2. 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Kiln seasoned and chemically treated Hollock wood [Through Rate] |
| 146 | [12.22.1]Providing and fixing plain lining with necessary screws/nuts and bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-in- charge (Frame work shall be paid separately). 1. 12mm thick commercial ply conforming to IS : 1328 BWR type [Through Rate] |
| 147 | [12.3.3.1.1]Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 3.1.1. 2nd class teak wood 50x12 mm [Through Rate] |
| 148 | [12.37.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws [Through Rate] |
| 149 | [12.45]Providing and fixing 18 mm thick, 150 mm wide pelmet of coir veneer board ISI marked IS : 14842, including top cover of 6 mm coir veneer board, nickel plated M.S. Pipe 20 mm dia. (heavy type) curtain rod with nickel plated brackets, including fixing with 25x3 mm M.S. Flat 10 cm long fixed to pelmet with Hollock wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. [Through Rate] |
| 150 | [12.6]Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). [Through Rate] |
| 151 | [12.7.1.1]Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 1.1. Second class teak wood 35 mm thick shutters [Through Rate] |
| 152 | [12.7.2.2]Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 2.2. Kiln seasoned and chemically treated Hollock wood 30 mm thick shutters [Through Rate] |
| 153 | [12.78.1]Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 1. 250x10 mm [Through Rate] |
| 154 | [12.78.3]Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 3. 150x10 mm [Through Rate] |
| 155 | [12.85.1]Providing and fixing bright finished brass handles with screws etc. complete: 1. 125 mm [Through Rate] |
| 156 | [12.85.2]Providing and fixing bright finished brass handles with screws etc. complete: 2. 100 mm [Through Rate] |
| 157 | [12.86]Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. [Through Rate] |
| 158 | [12.89]Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. [Through Rate] |
| 159 | [12.9.7.2]Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : 7.2. 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). [Through Rate] |
| 160 | [12.98.1]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm [Through Rate] |
| 161 | [13.21.1]Supply and fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm and Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets and screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 1. Door Frame of size 80mm x 50mm with 37mm wide single rebate for 35mm door shutter [Through Rate] |
| 162 | [13.22.1]Supply and fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanized sheet (Base steel as per IS 513) with zinc of 120 gm/sqm steel sheet pre coated (as per approved colour) with Polyester paint of 12-16 microns thickness under coat of EPOXY primer and back coat with ALKYD backer of 5-7 microns, total sheet thickness with coating 0.58mm of approved shade, weld less corner assembly with brackets and screws, fixed in position by means of PVC and metal hold fastener with PVC cap complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 1. Windows Outer frame of size 72mm x 55mm and central mullion 72mm x 50mm with Double rebate [Through Rate] |
| 163 | [13.28]Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. [Through Rate] |
| 164 | [13.29.2]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works [Through Rate] |
| 165 | [13.3.1.1]Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb [Through Rate] |
| 166 | [13.3.2.1]Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 2.1. Profile C Fixing with adjustable lugs with split end tail to each jamb [Through Rate] |
| 167 | [13.30.2]Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 2. Hot finished seamless type tubes [Through Rate] |
| 168 | [13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate] |
| 169 | [17.15.3]Granular Sub-Base with Coarse Graded Material - Grading-I or II or III (Table:- 400-2) Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.of MORTandH specifications 3. Grading III material [Through Rate] |
| 170 | [17.23.2]Water Bound Macadam Grading - II 2. Water Bound Macadam (53mm to 22.4 mm)Grading II with screenings Type “B” (11.2 mm aggregates) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications [Through Rate] |
| 171 | [17.25.1]Prime Coat @ 0.85kg per sqm 1. Prime Coat @ 0.60kg per sqm Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical means as per technical clause 503 of MORT&H specifications [Through Rate] |
| 172 | [17.27.2]Bituminous Macadam with batch type HMP 2. Bituminous Macadam 50 to 75 mm thickness (grading II) with batch type hot mix plant 100 -120 TPH Providing and laying bituminous macadam 50-75 mm thick with Batch type hot mix plant 100-120 TPH using crushed aggregates of specified grading premixed with bituminous binder VG - 30 @3.4% transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction complete as per technical clause 504 of MORT&H specifications Grading II (19 mm nominal size) [Through Rate] |
| 173 | [17.5.3]Compacting Original Ground 3. Compaction of Earthwork Compaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications [Through Rate] |
| 174 | [17.58]Repair of old Joints Sealant Removal of existing sealant and re sealing of contraction, longitudinal or expansion joints in concrete pavement with fresh sealant material, as per technical clause 3005 of MORT&H specifications [Through Rate] |
| 175 | [18.40]Supplying and laying of drainage composite for use behind walls, between two different fills, alongside drains of road, below concrete lining of canals etc. Geocomposite for planar drainage, realized by thermo bonding a draining core in extruded monofilaments with two filtering nonwoven geotextile that may also be working as separation or protecting layers. The draining three dimensional core will have a “W” configuration as longitudinal parallel channels. Minimum thickness to be 7.2mm, with two filtering UV stabilized polypropylene nonwoven geotextile of minimum thickness of 0.75mm characteristic opening size (O90) of 110 micron and tensile strength of 8.0 kN/m that will be working as separation or protecting layer, Geocomposite having in plane flow capacity of 2.1 L / (m.s) at hydraulic gradient of 1.0 and 20 kPa pressure and tensile strength of 18 kN/m , with mass per unit area of 740 gsm, supplied in the form of roll for easy transportation to site of work as per detailed specification all complete as per directions of Engineer in charge. [Through Rate] |
| 176 | [18.48]Assembling 40 mm. pressure pipes. [Through Rate] |
| 177 | [2.B0269] B0269. 12.5 mm thick Fully perforated gypsum board [Rate] |
| 178 | [2.B0401] B0401. Cutting groove in RCC (75mmx10mm) [Rate] |
| 179 | [2.B0897] B0897. Ceiling sections 0.55 mm thick having a knurled web of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm [Rate] |
| 180 | [2.B0898] B0898. perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of 0.55 mm and web of length 27 mm [Rate] |
| 181 | [2.B0899] B0899. Nylon sleeves & wooden screws (40 mm) [Rate] |
| 182 | [2.B0900] B0900. Counter sunk ribbed head screw 25 mm [Rate] |
| 183 | [2.B1894] B1894. Calcium silicate base compound for jointing calcium silicate tiles [Rate] |
| 184 | [2.B1906] B1906. Fibre joint tape 50 mm wide (90 metre) roll [Rate] |
| 185 | [20.11.1]Providing and fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge 1. 80 mm i/d [Through Rate] |
| 186 | [20.114.1]Supplying erection, testing of fullyautomatic electric control panel board forT/Wells in Pump Chamber consisting ofMS sheet of thickness 14 gauge dulypainted box type floor mounted made ofangle Frame containing 1 no. fullyautomatic air brake starter suitable forMotor of the following capacity, Minswitch of suitable range with HRC fuse, 1no. volt meter (0 to 500 volts), 1 No.Amp. Meter of 0 to 100 amp. 3 sets ofindicating lamp capacitor of suitablecapacity and 1 no. single phase preventerswith the timer switch including wiring inpanel board and suitable electric energymeter wiring in Electric Control PanelBoard complete in all respect as perspecification given in Schedule No. II,Including MCB, suitable, Capacitor,Wooden Box etc as per siterequirement complete in all respect. 1. 10 HP Motor [Through Rate] |
| 187 | [20.123.3]Supplying, erection, testing andcommissioning of horizontal motorpumping set for clear water having head50.00 m as per the indicated requirementsof discharge in LPM and power capacityin BHP as per IS marked. 3. Discharge Capacity (LPM) 500 Power Capacity (BHP) 10 [Through Rate] |
| 188 | [20.124.1]Supplying, erection, testing and commissioning of submersible pumping sets as per BIS SPECIFICATION No. 8034-1989 (as amended upto date for pumps) and IS 9283-1979 (as amended upto date for motor) the pump motor sets should be capable of pumping clear fresh cold water having characteristics as specified in Clause-4 of IS 8034-1989 and Clause 4.1 of IS 9283-1979. 1. LPM 400 Head 70 BHP 10.37 Say Round BHP 10.00 [Rate] |
| 189 | [20.13.2]Providing and fixing cast iron single air valves marked with IS:14845 including carriage, loading, uploading stacking, handling, re-handling etc. drilling, tapping, screwing etc. in valves connections complete in all respects to the satisfaction of Engineer-in-charge. (Rate is same for 40mm/50mm i/d pipes) 2. 50 mm i/d [Through Rate] |
| 190 | [20.25.1]Cutting holes up to 23 cm square through brick work in mud walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 1. 11.43 cm thick wall [Through Rate] |
| 191 | [20.25.2]Cutting holes up to 23 cm square through brick work in mud walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 2. 22.86 cm thick wall [Through Rate] |
| 192 | [20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) [Through Rate] |
| 193 | [20.72]Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. [Through Rate] |
| 194 | [21.28]Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge [Through Rate] |
| 195 | [21.57.1.2]Providing masonry plugs to ends of sewers of all types with 11.43 cm thick brick wall in cement sand mortar 1:7 with 12 mm thick cement plaster 1:6 (as required by the engineer-in-charge). 1.2. For Circular sewers having internal diameter - 150 mm [Through Rate] |
| 196 | [21.84.1]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 1. Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping [Through Rate] |
| 197 | [21.84.2]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 2. Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping) [Through Rate] |
| 198 | [21.84.3]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) [Through Rate] |
| 199 | [21.85.2]Extra for every 0.30 metre depth of Inspection chamber 2. 450 mmx 600 mm inside [Through Rate] |
| 200 | [21.85.3]Extra for every 0.30 metre depth of Inspection chamber 3. 600 mm x 900 mm inside [Through Rate] |
| 201 | [21.87.1.1]Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item No.10.6) in foundations 1st class brick work laid in cement sand mortar 1:5, 40 mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12mm in thickness of 1:2 cement sand plaster and finished with floating coat of neat cement 1 mm thick left absolutely smooth polished and correct to templates including labour for fixing the C.I. road gully grating and frame including painting with coal tar (as Specified in item No. Item 21.48) complete to the requirement of the Engineer in-charge 1.1. Single road gully chamber - Size: 610mm x 457mm x 800mm [Through Rate] |
| 202 | [21.93.2]Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 2. Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening [Through Rate] |
| 203 | [22.1.4]Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 4. White vitreous chinaware Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap [Through Rate] |
| 204 | [22.103.3]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore [Through Rate] |
| 205 | [22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore [Through Rate] |
| 206 | [22.106.1]Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore [Through Rate] |
| 207 | [22.107.1]Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore [Through Rate] |
| 208 | [22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore [Through Rate] |
| 209 | [22.109]Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. [Through Rate] |
| 210 | [22.119.1]Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 1. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms [Through Rate] |
| 211 | [22.127]Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. [Through Rate] |
| 212 | [22.128.1]Providing and fixing Unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 1. 15 mm nominal bore with 30cm length [Through Rate] |
| 213 | [22.128.2]Providing and fixing Unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 2. 15 mm nominal bore with 45 cm length [Through Rate] |
| 214 | [22.14.1.2]Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 1.2. Semi rigid pipe 40 mm dia [Through Rate] |
| 215 | [22.15]Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge. [Through Rate] |
| 216 | [22.16]Providing and fixing 40mm i/d G.I. waste pipe embedded in walls up to floor level including cost of union and plumber joint [Through Rate] |
| 217 | [22.166.1.1]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 1.1. 100x100 mm size P type With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 218 | [22.166.2.2]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 2.2. 150 x 100 mm size P type With sewer bricks conforming to IS : 4885 [Through Rate] |
| 219 | [22.181]Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. [Through Rate] |
| 220 | [22.182]Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet and over flow pipes. The base support i/c fittings and fixtures for tank shall be paid separately. [Through Rate] |
| 221 | [22.190.2.1]Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 2.1. Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 222 | [22.198.1]Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 1. With 20x20 mm square bar [Through Rate] |
| 223 | [22.20.2]Providing and fixing in position C.I. plain Nahani Trap conforming to I.S.I. specifications and of self cleaning design with C.P. brass hinged grating with frame complete 2. With 75 mm internal diameter outlet [Through Rate] |
| 224 | [22.201.2.2]Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 2.2. M D - 10 Circular shape 500 mm internal diameter [Through Rate] |
| 225 | [22.209]Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. [Through Rate] |
| 226 | [22.212.1.1]Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. 1.1. C.P Brass One Way [Through Rate] |
| 227 | [22.221.9]Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. 9. Size 560mm x 450mm (Under counter oval) [Through Rate] |
| 228 | [22.222.1.1]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 1.1. Single Socket Type A 160mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 229 | [22.222.1.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 1.2. Single Socket Type A 110mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 230 | [22.222.1.4]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 1.4. Single Socket Type A 75mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 231 | [22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 232 | [22.33]Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. [Through Rate] |
| 233 | [22.34]Providing and fixing floor mounted, white vitreous chinaware single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous chinaware cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. [Through Rate] |
| 234 | [22.38]Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. [Through Rate] |
| 235 | [22.42.1]Providing and fixing toilet paper holder : 1. C.P. brass [Through Rate] |
| 236 | [22.46]Providing and fixing white vitreous chinaware battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water (250 ml and 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. [Through Rate] |
| 237 | [22.5]Providing and fixing white vitreous chinaware pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. [Through Rate] |
| 238 | [22.53.1]Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 1. For 100 mm dia pipe [Through Rate] |
| 239 | [22.53.2]Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 2. For 75 mm dia pipe [Through Rate] |
| 240 | [22.85.5]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 5. 40 mm nominal outer dia Pipes [Through Rate] |
| 241 | [22.86.1]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1. 15 mm nominal outer dia Pipes [Through Rate] |
| 242 | [22.86.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes [Through Rate] |
| 243 | [22.86.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate] |
| 244 | [22.86.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes [Through Rate] |
| 245 | [22.87.6]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 6. 50 mm nominal outer dia Pipes [Through Rate] |
| 246 | [22.89.2]Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 2. 20 mm dia nominal bore [Through Rate] |
| 247 | [22.9.1]Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: 1. White glazed fire clay kitchen sink of size 600x450x 250 mm [Through Rate] |
| 248 | [22.90]Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. [Through Rate] |
| 249 | [22.92.2]Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 2. 50 to 80 mm nominal bore [Through Rate] |
| 250 | [22.98.1]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore [Through Rate] |
| 251 | [23.1.1.3]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. [Through Rate] |
| 252 | [23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA [Through Rate] |
| 253 | [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate] |
| 254 | [23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate] |
| 255 | [23.22.4.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) [Through Rate] |
| 256 | [23.22.4.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) [Through Rate] |
| 257 | [23.22.4.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.6. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing) [Through Rate] |
| 258 | [23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate] |
| 259 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] |
| 260 | [23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate] |
| 261 | [23.22.8.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.3. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 200 amp 415 volts [Through Rate] |
| 262 | [23.23.6..2]MISCELLANEOUS 6..2. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 200 X 50 X 2 mm [Through Rate] |
| 263 | [23.23.6.1]MISCELLANEOUS 6.1. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 100 X 50 X 2 mm [Through Rate] |
| 264 | [23.23.6.3]MISCELLANEOUS 6.3. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 375 X 50 X 2 mm [Through Rate] |
| 265 | [23.23.6.4]MISCELLANEOUS 6.4. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 600 X 50 X 2 mm [Through Rate] |
| 266 | [23.23.7.1]MISCELLANEOUS 7.1. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 100 X 50 X 2 mm [Through Rate] |
| 267 | [23.23.7.2]MISCELLANEOUS 7.2. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 200 X 50 X 2 mm [Through Rate] |
| 268 | [23.23.7.3]MISCELLANEOUS 7.3. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 375 X 50 X 2 mm metre [Through Rate] |
| 269 | [23.23.7.4]MISCELLANEOUS 7.4. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 600 X 50 X 2 mm [Through Rate] |
| 270 | [23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] |
| 271 | [23.24.4.2]MS STAND, BUS BAR CHAMBER AND PANELS 4.2. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 8 way 250 amp. [Through Rate] |
| 272 | [23.26.1]SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. [Through Rate] |
| 273 | [23.27.2]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 2. M.S. pedestal of size 750 mm wide , 900 mm high , 300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . 0 0 [Through Rate] |
| 274 | [23.28.16.4]Supplying, installation, Testing and Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency )85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP-66,IK-10, CRI )80 , under voltage and over voltageprotection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg, suitable tiltable fitting, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IE TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 and (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 4. 150 watt [Rate] |
| 275 | [23.28.19.1]Supplying, installation, Testing and Commissioning of Smart Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement ( ( 700ma), Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000- 4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP-66,IK-08, CRI )80 , under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 and (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 1. Control and monitor LED luminaries with bi directional control (Status, Fault, Alarm, dimming level, wattage, energy) 2. to measure voltage, current, power, power factor, apparent energy, active energy, operating hours. 3. Inbuilt ambient light sensor, motion sensor based on Passive Infra Red (PIR). 4. Wi-Fi LoRA/Zigbee/Power line with Ethernet network based IOT feature as per site requirement or engineer in charge. 5. should be controlled through auto/ manual 6. Programmable level of not less than 48 different light intensity settings, 7. Inbuilt repeater and relay signals function to other controllers 1. 45 Watt [Rate] |
| 276 | [23.28.2.1]Supplying, installation, Testing and Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , UGR (Unified Glare Rating) ( 19, Flicker free (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. `complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C 1. 5-7 watt [Rate] |
| 277 | [23.28.2.3]Supplying, installation, Testing and Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , UGR (Unified Glare Rating) ( 19, Flicker free (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. `complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C 3. 12-15 watt [Rate] |
| 278 | [23.28.31.5]Supplying, Installation, Testing and Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV plus or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system, including testing at factory and site with fuel, load for test and other necessary arrangements with rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine: Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Deg C, 50% RH and at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV plus or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018. (B) Engine mounted Instrument Panel fitted with and having digital display for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubrication Oil trip indication(ix) Engine Running Hours indication (x) Fuel Level(C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH and at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.(D) Base Frame and Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(E) FUEL TANK: Daily service fuel tank of suitable liters capacity, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications and accessories as required as per specifications.(F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine and alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof and dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV plus or better norms etc. and.(I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering and protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase and Total), KW and provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C and E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering5. Energy analyser unit to indicate current, Voltage( LN and L_L), kW, kVA (Phase and Total), Frequency, KWH, PF.6. LED Indicating lamps for load on mains and load on set7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier,D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories17. Maintenance notification based on Engine Run Hour and due date.18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel, interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.19. Suitable rating of AC contactors/ ATS / ACB with control wiring. 5. 58.5/62.5 KVA [Rate] |
| 279 | [23.28.7.10]Supplying, installation, Testing and Commissioning of Panel light 2x2 ft., offollowing body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80, UGR (Unified Glare Rating) ( 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) 10. CRCA Sheet Body (Thickness >= 0.50 mm) 36 Watt [Rate] |
| 280 | [23.4.1.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.2. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B [Through Rate] |
| 281 | [23.4.4.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.2. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B [Through Rate] |
| 282 | [23.4.5.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.2. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B [Through Rate] |
| 283 | [23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] |
| 284 | [23.5.6.2]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate] |
| 285 | [23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate] |
| 286 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] |
| 287 | [23.8.1.12]FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. [Through Rate] |
| 288 | [23.8.1.5]FITTING AND ACCESSORIES 1.5. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type [Through Rate] |
| 289 | [23.8.1.6]FITTING AND ACCESSORIES 1.6. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Call bell 220/230 volts musical type [Through Rate] |
| 290 | [23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data [Through Rate] |
| 291 | [23.8.10.3]FITTING AND ACCESSORIES 10.3. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 4 Modules [Through Rate] |
| 292 | [23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch [Through Rate] |
| 293 | [23.8.11.11]FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type [Through Rate] |
| 294 | [23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket [Through Rate] |
| 295 | [23.8.11.5]FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket [Through Rate] |
| 296 | [23.8.11.6]FITTING AND ACCESSORIES 11.6. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Bell Push [Through Rate] |
| 297 | [23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt [Through Rate] |
| 298 | [23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. [Through Rate] |
| 299 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] |
| 300 | [24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 301 | [24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. [Through Rate] |
| 302 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] |
| 303 | [24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate] |
| 304 | [24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate] |
| 305 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate] |
| 306 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 307 | [24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. [Through Rate] |
| 308 | [24.13.18]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 18. 10 Sq mm 4 core (Arm.) [Through Rate] |
| 309 | [24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate] |
| 310 | [24.13.46]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 46. 50 Sq mm 3.5core (Arm.) [Through Rate] |
| 311 | [24.14.14]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 14. 10 Sq mm 2core (Arm.) [Through Rate] |
| 312 | [24.14.15]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 15. 10 Sq mm 3 core (UnArm.) [Through Rate] |
| 313 | [24.14.20]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 20. 16 Sq mm 2core (Arm.) [Through Rate] |
| 314 | [24.14.62]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 62. 95 Sq mm 3.5 core (Arm.) [Through Rate] |
| 315 | [24.2.8.3]LT CABLE 8.3. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 10 sqmm [Through Rate] |
| 316 | [24.2.8.4]LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm [Through Rate] |
| 317 | [24.4.16]STREET LIGHT 16. Supply and erection of weather proof M.S. box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S. sheet hinged cover, locking arrangement , housed in wall , including the cost of 1 no. 16 amp. 415 volts SP MCB and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board/10 mm Bakellite sheet in the M.S. box including painting and necessary connections . [Through Rate] |
| 318 | [24.4.4.2]STREET LIGHT 4.2. Erection of street light fitting on the pole including the cost of petty material required (irrespective of height/length of bracket) At Pole above 4.5 metres but up to the height of 7 metres. [Through Rate] |
| 319 | [24.4.8.5]STREET LIGHT 8.5. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 7 Metre Long pole with top dia 75 0mm and bottom dia 150 mm with base plate of size 300 x 300 x 20 mm [Through Rate] |
| 320 | [24.5.2.2]MISCELLANEOUS ITEMS 2.2. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 50/40 mm outer dia/ inner dia [Through Rate] |
| 321 | [24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia [Through Rate] |
| 322 | [24.7.2]RCC FOUNDATIONS FOR DG SET 2. 60 to 90 KVA DG Set [Through Rate] |
| 323 | [24.8.5]RCC FOUNDATIONS FOR OCTAGONAL POLES 5. Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 7m high pole [Through Rate] |
| 324 | [25.1.3]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 3. 200mm dia. [Through Rate] |
| 325 | [25.1.4]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 4. 150mm dia. [Through Rate] |
| 326 | [25.1.6]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 6. 100mm dia. [Through Rate] |
| 327 | [25.1.7]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 7. 80mm dia. [Through Rate] |
| 328 | [25.1.9]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 9. 50mm dia. [Through Rate] |
| 329 | [25.10.11.9]Supplying, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted mid high static ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The cooling capacity of indoor unit will be at air inlet conditions of 27 °C DB and 19 °C WB temperature. (Make will be same as of Outdoor) 9. High static ductable units (minimum 49 to 77 pascal external static pressure) 4.6 TR [Rate] |
| 330 | [25.10.12.1]Supplying, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted high ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The cooling capacity of indoor unit will be at air inlet conditions of 27 °C DB and 19°C WB temperature. (Make will be same as of Outdoor) 1. High Static Ductable units (minimum 78 pascal external static pressure) 5.5 TR [Rate] |
| 331 | [25.10.13.1]Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs 1. Indoor units [Rate] |
| 332 | [25.10.13.2]Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs 2. Outdoor Multi Join [Rate] |
| 333 | [25.10.3.2]OUTDOOR UNIT Supplying, Installation, Testing and Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 °C. The unit shall be suitable to work on 400V plus /- 10%, 3 Phase, 50Hz AC power supply and BMS compatible The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity (40 kWr ISEER 7.4, Capacity ) 40 and (70 ISEER 7.5, Capacity ) 70 ISEER 7.6 for Super ECSBC Building) 2. For Cooling or Heating or Both 10 HP to 12 HP [Rate] |
| 334 | [25.10.4.7]INDOOR UNIT Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 °C DB and 19 °C WB temperature. (Make will be same as of Outdoor) 7. 2.6 TR [Rate] |
| 335 | [25.10.4.9]INDOOR UNIT Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 °C DB and 19 °C WB temperature. (Make will be same as of Outdoor) 9. 4.1 TR [Rate] |
| 336 | [25.11.2.4]HI - WALL SPLIT SYSTEMS Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS:1391 Part II 2023. The system shall be able to operate up to 50 °C (out door ambient temperature). 4. Inverter Type- Cooling only 2.0 TR with 5 Star BEE Rating [Rate] |
| 337 | [25.3.4]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 4. 150mm dia. [Through Rate] |
| 338 | [25.3.7]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 7. 80mm dia. [Through Rate] |
| 339 | [25.4.2]Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 2. 150mm dia. [Through Rate] |
| 340 | [25.4.5]Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 5. 80mm dia. [Through Rate] |
| 341 | [25.9.12.1]Supplying, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation to IS : 655 and approved drawings and specifications of following sheet thickness complete as required. 1. Thickness 0.63 mm sheet [Rate] |
| 342 | [25.9.12.2]Supplying, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation to IS : 655 and approved drawings and specifications of following sheet thickness complete as required. 2. Thickness 0.80 mm sheet [Rate] |
| 343 | [25.9.12.3]Supplying, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation to IS : 655 and approved drawings and specifications of following sheet thickness complete as required. 3. Thickness 1.00 mm sheet [Rate] |
| 344 | [25.9.12.4]Supplying, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation to IS : 655 and approved drawings and specifications of following sheet thickness complete as required. 4. Thickness 1.25 mm sheet [Rate] |
| 345 | [25.9.13]Supplying, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required. [Rate] |
| 346 | [25.9.15]Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required. [Rate] |
| 347 | [25.9.16]Supplying and fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specifications complete etc. as required. [Rate] |
| 348 | [25.9.17]Supplying, Fixing, installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring and removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required. [Rate] |
| 349 | [25.9.18]Supplying, Fixing, installation, testing and commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring and removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required. [Rate] |
| 350 | [25.9.20.1]Supplying, Fixing, installation, testing and commissioning of fire dampers of minimum 9 minutes fire rated in supply air/duct branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal and, in confirmation to IS and as per specifications complete etc. as required. 1. Fire damper [Rate] |
| 351 | [25.9.20.2]Supplying, Fixing, installation, testing and commissioning of fire dampers of minimum 9 minutes fire rated in supply air/duct branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal and, in confirmation to IS and as per specifications complete etc. as required. 2. Actuator [Rate] |
| 352 | [25.9.22]Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications [Rate] |
| 353 | [26.10]Maintenance of fine grass lawn for one year including fertilizer application, DAP @ 20gm/sqm, urea 40gm/sqm, watering, weeding, top dressing with good earth and manure mixture 2:1 @ 0.01cum per sqm, maintaining fine level, regular mowing and removal of rubbish with all lifts and leads. [Through Rate] |
| 354 | [26.13.6]Digging holes in all kinds of soil, and refilling the same, with the excavated earth, mixed with well decayed farmyard manure (cost of well decayed farm yard manure to be paid separately) 6. Digging of pits in all kinds of soil & refilling the same, with the excavated earth mixed with well decayed farm yard manure @ 30% of pit volume and insecticide for termite control ( Excluding cost of FYM and Insecticide.) [Through Rate] |
| 355 | [26.14]`Supplying and planting in prepared pits and watering, healthy , vigorous growing , permanent trees including ,application of 10 ml chlorpyriphos 20% EC, planting desired disease free, 200 cm to 220 cm height ,5 cm to 6 cm calliper size stem , full of foliage ornamental tree sapling each to be supplied in 30cm x 30cm poly bags,` [Through Rate] |
| 356 | [26.15.1]Maintenance of tree including fertilization, application of insecticide, watering, weeding, training, pruning, 1. Maintenance of tree for one year for the 1st three years of age including weeding, hoeing , plant protection , watering from Deptt. source , application of 10 ml chlorpyriphos four times, 0.0289 cum FYM each,50 gm urea and 50 g DAP twice ,replacement of casualty ,disposal of debris and other activities.etc. [Through Rate] |
| 357 | [26.15.2]Maintenance of tree including fertilization, application of insecticide, watering, weeding, training, pruning, 2. Maintenance of tree for one year for the age of tree of 4th, 5th and next years including weeding, hoeing, plant protection, the watering from Deptt. source, application of 10 ml chlorpyriphos four times, 0.0289 cum FYM each, 50 gm urea and 50 g DAP twice, replacement of casualty etc. [Through Rate] |
| 358 | [26.16]Pruning, trimming, shaping of mature trees /shrubs (ht 15 feet and above) including removal and disposal of cut materials up to 50m lead. [Through Rate] |
| 359 | [26.18]Supply and planting of disease free healthy , vigorous growing more than 75 cm height permanent shrubs in already prepared pits, supplied in 25 cm x 20 cm poly bags , application of 10 ml chlorpyriphos 20% E.C. termiticide each and watering supplied through the tractor tanker. [Through Rate] |
| 360 | [26.19.1]Maintenance of shrub for one year including weeding, hoeing, plant protection, watering from Deptt. source, application of 10 ml chlorpyriphos four times in a year , 0.0289cum FYM each, 20 gm urea and 20 gm DAP twice, replacement of casualty etc. with same species and same age of plant 1. Individual shrubs [Through Rate] |
| 361 | [26.4.2]SITE CLEARANCE 2. Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kind of soils . [Labour Rate] |
| 362 | [26.4.8]SITE CLEARANCE 8. Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts. [Through Rate] |
| 363 | [26.54.1]Anti termite treatment of lawns, mature trees. 1. Treatment of lawn area through Imidacloprid 30.5% SC including cost of insecticide, water and spraying machine [Through Rate] |
| 364 | [26.54.2]Anti termite treatment of lawns, mature trees. 2. Treatment around mature trees by digging holes 30 cm deep and 4 cm dia, 6 to 7 holes around tree using 1% chemical emulsion of Chlorpyriphos 20% E.C using minimum 150 ml insecticide per plant. [Through Rate] |
| 365 | [26.63.1]Providing and fixing steel tree guard 1. MS circular tree guard 60 cm dia and 1.8 metres. height above ground level formed of 4 Nos. of angle irons of 25 x 25 x 3 mm 2.10 m long, 4 Nos. 25mm x 3mm, 1.5 m long vertical MS flat welded to 3 no. 25 mm x 6mm M.S flat iron rings in two halves bolted together with 8mm dia & 30 mm long bolts and fixing 250 mm X 100 mm iron plate, fixed in ground with 1:2:4 cement concrete, complete in all respects. Minimum weight should be 20.85 kg before primer and paint . [Through Rate] |
| 366 | [26.71.1]Supply and installation of pop up sprinklers 1. Pop up Impact Rotors 3/4\\" inlet and radius ranging from 7-12 m with interchangeable nozzles with check valve and all accessories complete as per BIS standard specifications and setting flow rate as directed. [Through Rate] |
| 367 | [26.73.10]Supply and installation of filters/ pressure relief valve for drip/ sprinkler system 10. Supply and installation of 50mm i/d hydraulic pressure relief valve of polemeride with accessories for pressure regulation of irrigation system as per B IS standard. 0.00 0.00 [Through Rate] |
| 368 | [26.9.8]Turfing lawns with fine grassing ( selection no.1/ Bermuda and Mexican/Neelgiri grass )including ploughing, dressing including breaking of clods, removal of rubbish, dressing and supplying of selection no. 1 / Bermuda doob grass and Mexican/Neelgiri grass roots, including supplying and spreading of farmyard manure at the rate of 0.60 cum per 100 sqm, maintenance till weed free turf is formed 8. Providing and fixing Neelgiri/ Mexican grass turf with earth 50mm to 60 mm thickness and ramming with required wooden tools, rolling with light roller to make the surface smooth and even. [Through Rate] |
| 369 | [28.18]Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservoir, sewage and water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer`s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. [Through Rate] |
| 370 | [28.20.1]Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage and water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 1. For vertical surface two coats @ 0.70 kg per sqm [Through Rate] |
| 371 | [28.21]Providing and Applying polymer modified, flexible cementitious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm one coat of self priming of cementitious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementitious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film and loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge. [Through Rate] |
| 372 | [28.28.1]Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : 1. Serrated with central bulb (225 mm wide, 8-11 mm thick) [Through Rate] |
| 373 | [28.29.1]Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled and honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystalline mortar shall conform to the EN 1504-3 having compressive strength Class R4 =45 MPa and adhesive bond strength Class R3 =1.5 MPa. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. 1. For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/running metre and while the surface is tacky filled the groove up to surface with crystalline mortar @1.50kg/running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running metre per coat. [Through Rate] |
| 374 | [28.40]Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building. [Through Rate] |
| 375 | [28.50]Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) ) 78, solar reflection ) 0.70 and initial emittance ) 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement and marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. [Through Rate] |
| 376 | [30.79]Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. [Through Rate] |
| 377 | [30.82.1]Making holes by cutting cores of appropriate dia in RCC floors and roofs of thickness up to 6` (six inches) for passing drain pipe and repairing the hole after insertion of drain pipe etc. including finishing-complete so as to make it leak proof. 1. Drain pipe of 150mm internal dia [Through Rate] |
| 378 | [32.70.2]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 2. Above 10 kWp and up to 100 Kwp [Through Rate] |
| 379 | [33.12]Supplying, filling, spreading and levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge. [Through Rate] |
| 380 | [33.13]Supplying, filling, spreading and levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge. [Through Rate] |
| 381 | [33.14]Supplying, filling, spreading and levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer -in-charge. [Through Rate] |
| 382 | [33.15]Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading and sizes as per actual requirement, all complete as per direction of Engineer-in-charge. [Through Rate] |
| 383 | [33.16.2]Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 2. 150 mm dia [Through Rate] |
| 384 | [33.17.2]Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts and nuts of required size complete. 2. 150 mm clamp [Through Rate] |
| 385 | [33.18.2]Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 2. 150 mm dia [Through Rate] |
| 386 | [33.8.2]Supplying, assembling, lowering and fixing in vertical position in bore well, Unplasticised PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 2. 150 mm nominal size dia [Through Rate] |
| 387 | [33.9.2]Supplying, assembling, lowering and fixing in vertical position in bore well Unplasticised PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 2. 150 mm nominal size dia [Through Rate] |
| 388 | [34.16.1]Definition Plate 600x200mm rectangular as per as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. specifications. Fixed over 3mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25X25X3mm welded with vertical post of sign board complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 . 1. Using retro reflective Sheeting Class C as per IRC 67 2012 [Through Rate] |
| 389 | [34.18.2]Direction/Diversion Plate 1800x300mm rectangular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. specifications. fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25X25X3mm fixed in position complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67- 2012 2. Using high intensity Microprismatic grade retro reflective Sheeting Class B as per IRC 67 2012 [Through Rate] |
| 390 | [34.19.2]Hazard Marker sign board 300x900mm rectangular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and IRC 67 2012, fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground including foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67- 2012. 2. Using high intensity Microprismatic grade retro reflective Sheeting Class B as per IRC 67 2012 [Through Rate] |
| 391 | [34.24.1]Painting Lines, Dashes, Arrows etc on Roads in Two Coats on New Work Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control 1. Over 10 cm in width [Through Rate] |
| 392 | [34.26]Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including Reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. [Through Rate] |
| 393 | [34.3.2]Printing New Letter and Figures of any ShadePrinting new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade 2. English and Roman (Hyphens not to be paid) [Through Rate] |
| 394 | [34.33]Road Markers/Road Stud with Lense Reflector Providing and fixing of road stud 100x 100 mm, die-cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm up to a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973 [Through Rate] |
| 395 | [34.35]Flexible Median Marker Providing and Fixing of Flexible Median Markers as per IRC 79:2019 which shall be made of combination of tough, high impact resistant molded thermoplastic body along with floroscent yellow colour retro-reflective Class C sheeting with minimum exposed reflective area 285 square mm and with rebound property. The reflective sheeting should confirm to Class C Yellow sheeting as per IRC 67-2012 . The flexible median marker shall have overall height of minimum 180 mm, width of minimum 120 mm, body thickness of minimum 2.0 mm and shank depth of minimum 30mm. The retro-reflective sheeting shall be on both sides of the Flexible Median Marker and shall be edge protected with no exposed edges which will prevent edge lifting, vandalism, sheeting damage, etc. The edge of sheeting should not come out easily by putting nails, sharp objects etc. The logo of the manufacturer shall be embossed on either side of the body. The product design has to with stand all natural impacts and should not get damaged if any pedestrian stamp on top of it intentionally or unintentionally. The product should bend up to 90 degree on both sides without breakage or damage. The Flexible Median Marker shall be tested from Government Lab for reboundability and tensile test as per IRC 79 :2019. [Through Rate] |
| 396 | [34.37]Road Delineators Providing and fixing of standard Metal Delineator as per IRC 79:2019 consisting of retro reflective area in white colour using Microprismatic retro reflective sheeting on each side conforming with IRC 67-2012 and meeting the coefficient of retro reflection values as per Class C table specification. The delineator shall be painted with only black colour powder coat of minimum 40 microns thickness, on top of retro reflective sheeting only in white colour shall be pasted on both sides. The structure shall have height not less than 800 mm above ground, width not less than 100 mm and shall extend not more than 300 mm below ground while being installed. The delineator shall have grooves across the length to make the reflective sheet vandal proof. The delineator is meant for application on gaps in median, traffic islands, dangerous bends, roundabouts, narrow bridges etc or as desired by site engineer. The product shall be provided with 3 year outdoor warranty report tested in India condition as per IRC 67: 2012 requirement.In case of soft ground, a proper foundation may be provided as per approved design. In case foundation is required to be provided, the items of excavation and foundation concrete are required to be measured and paid separately. [Through Rate] |
| 397 | [36.1.9]Supplying, installation, testing and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required:(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-12615: 2018.(d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered with anti vibration pads. 9. 2280 lpm at 56 M Head [THROUGH RATE] |
| 398 | [36.11.4]Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required: 4. 80 mm dia [THROUGH RATE] |
| 399 | [36.11.6]Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required: 6. 150 mm dia [THROUGH RATE] |
| 400 | [36.12.3]Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 offollowing sizes as required: 3. 80 mm dia [THROUGH RATE] |
| 401 | [36.12.5]Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 offollowing sizes as required: 5. 150 mm dia [THROUGH RATE] |
| 402 | [36.12.6]Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 offollowing sizes as required: 6. 200 mm dia [THROUGH RATE] |
| 403 | [36.13]Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to thelevel of 3.5 kg/cm2 complete as required. [THROUGH RATE] |
| 404 | [36.14.7]Providing, installation, testing and commissioning of nonreturn valve of following sizes confirming to IS: 5312 complete with rubber gasket, Gl bolts, nuts, washersnetc.as required: 7. 150 mm dia [THROUGH RATE] |
| 405 | [36.15.4]Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm. thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 4. 200 mm dia [THROUGH RATE] |
| 406 | [36.16.2]Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with Gl wire, rivets etc. conforming to IS 636 (type-A) as required: 2. Stainless Steel (Grade 304) [THROUGH RATE] |
| 407 | [36.17.1]Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type 2 as per IS: 12585(b) 20 mm nominal internal dia gun metal globe valve and nozzle.(c) Drum and brackets for fixing the equipmets on wall.(d) Connections from riser with 25 mm dia stop gun metal valve and M.S. Pipe and socket. 1. 30m [THROUGH RATE] |
| 408 | [36.18.2]Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneousconnection to interconnect hose pipe coupling as required: 2. Stainless Steel (Grade 304) [THROUGH RATE] |
| 409 | [36.19.1]Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 1. 2 way-100 mm dia M.S. Pipe [THROUGH RATE] |
| 410 | [36.19.2]Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 2. 4 way - 150 mm dia M.S. Pipe [THROUGH RATE] |
| 411 | [36.2.6](a) Supplying, installation, testing and commissioning of diesel engine driven main fire pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)(b) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal asrequired.(c) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.(d) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered and with antivibration pads 6. 180 lpm at 56 M Head [THROUGH RATE] |
| 412 | [36.20]Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve withrequired accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. [THROUGH RATE] |
| 413 | [36.22.2]Providing and fixing of pressure switch in M.S. pipe line including connection etc. as required. 2. 150mm dia [THROUGH RATE] |
| 414 | [36.3.6]a) Supplying, installation, testing and commissioning of electric driven pressurisation pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)(b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-12615: 2018.(d) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plasteredand with anti vibration pads. 6. 180 lpm at 56 M Head [THROUGH RATE] |
| 415 | [36.30]Providing, fixing, testing and commissioning of ISI marked (ISI MARK 15683) portable CO2 fire extinguisher of capacity 4.5 kg including valve,horn,suitable handle, discharge hose of one meter long complete in all respect with explosive certificate . [THROUGH RATE] |
| 416 | [36.35]Providing, fixing, testing and commissioning of ISI marked (ISI MARK 15683) portable ABC multipurpose filled by 90% (MAP) mono amonioum phosphate powders, nitrogen pressurised type fire extinguisher with meter, hose reel rubber pipe with 0.50 mtr long with capacity of 6 kg complete in all respect. [THROUGH RATE] |
| 417 | [36.4.2](a) Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-`F` insulation,conforming to IS-12615: 2018.(d) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads. 2. 450 lpm at 35 M Head [THROUGH RATE] |
| 418 | [36.41]Providing, fixing, testing and commissioning of dial type Stainless Steel Pressure Gauge with brass isolation valve and steel/cooper pipe complete in all respect. [THROUGH RATE] |
| 419 | [36.42]Providing, fixing, testing and commissioning of Air Release Valve of size 25 mm dia to reduce pressure and trapped air in the pipe line complete in all respect. [THROUGH RATE] |
| 420 | [36.44.1]Providing, fixing, testing and commissioning of double flanged rubber expansion bellow joint with unit control of standard length and tested upto pressure of 15kg/cm2 including rubber gaskets, flanges,nuts,bolts, and washers complete in all respect. 1. 80 mm dia [THROUGH RATE] |
| 421 | [36.44.3]Providing, fixing, testing and commissioning of double flanged rubber expansion bellow joint with unit control of standard length and tested upto pressure of 15kg/cm2 including rubber gaskets, flanges,nuts,bolts, and washers complete in all respect. 3. 150 mm dia [THROUGH RATE] |
| 422 | [36.45]Providing, fixing, testing and commissioning of Diesel Engine Battery of capcity 150 Amp. with automatic charge controller for diesel pump complete in all respect. [THROUGH RATE] |
| 423 | [36.48]Supply, Insallation, testing and commissioning of Electrical fire pump panel for terrace fabricated with 2mm thick Ms sheet with hinged lockable doors, powder coated of approved shade including all accessories complete in all respect. 450 LPM. [THROUGH RATE] |
| 424 | [36.5.2]Fabrication, supplying, Installation testing and commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cablealley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earthterminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump and diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3phase, 50Hz Ac Supply with enclosure protection class IP 42 as required: 2. INCOMING400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500AOUTGOING Main Fire Pump 200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Diesel Engine Control Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual modeIndicating lamp for high/Low Lub. Oil pressure, HighWater Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC AmmeterAll standard relays and accessories for automaticoperation of diesel engine System ControllerDesigning, Supply, Installation, Testing andcommissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications. [THROUGH RATE] |
| 425 | [36.6.2]Providing laying, testing and commissioning of `C` class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation and providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 2. 150 mm. Dia [THROUGH RATE] |
| 426 | [36.7.1]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 1. 25 mm dia [THROUGH RATE] |
| 427 | [36.7.4]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 4. 50 mm dia [THROUGH RATE] |
| 428 | [36.7.6]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 6. 80 mm dia [THROUGH RATE] |
| 429 | [36.7.7]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 7. 100 mm dia [THROUGH RATE] |
| 430 | [36.7.8]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 8. 150 mm dia [THROUGH RATE] |
| 431 | [36.7.9]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 9. 200 mm dia [THROUGH RATE] |
| 432 | [36.9.1]Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless Steelcap and chain as required. 1. Single headed Stainless steel [THROUGH RATE] |
| 433 | [4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate] |
| 434 | [4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. [Through Rate] |
| 435 | [4.16.1.2]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. [Through Rate] |
| 436 | [4.31.1]Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 1. All kinds of soil [Through Rate] |
| 437 | [4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate] |
| 438 | [4.33]Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. [Through Rate] |
| 439 | [4.39]Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% [Through Rate] |
| 440 | [4.4.1]Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. 1. All kinds of soil [Through Rate] |
| 441 | [6.1.1]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 442 | [6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 443 | [6.1.4]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 4. 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 444 | [6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate] |
| 445 | [6.1.7]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 7. 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) [Through Rate] |
| 446 | [6.1.8]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 8. 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) [Through Rate] |
| 447 | [6.10]Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. [Through Rate] |
| 448 | [6.13.A]Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth. A. Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling & dressing & finishing the top smooth. [Rate] |
| 449 | [6.14.1]Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 450 | [6.15.1]Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 451 | [6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate] |
| 452 | [6.2.1]Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor four level, excluding the cost of centering, shuttering and finishing: 1. 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate] |
| 453 | [6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level [Through Rate] |
| 454 | [6.29.1]Centering and shuttering including strutting, propping etc. and removal of form work for : 1. Foundations, footings, bases for columns [Through Rate] |
| 455 | [6.29.2]Centering and shuttering including strutting, propping etc. and removal of form work for : 2. Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. [Through Rate] |
| 456 | [6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete [Through Rate] |
| 457 | [6.30.2]Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. [Through Rate] |
| 458 | [6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate] |
| 459 | [6.30.4]Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ) [Through Rate] |
| 460 | [6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate] |
| 461 | [6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts [Through Rate] |
| 462 | [6.30.7]Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases [Through Rate] |
| 463 | [6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate] |
| 464 | [6.34.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. [Through Rate] |
| 465 | [6.39.1]Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate] |
| 466 | [6.42.B]Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. Pipes 40 mm dia and 450mm long with 150x150x6mm M.S. plate welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size), including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing. B. Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. Pipes 40 mm dia and 450mm long with 150x150x6mm M.S. plate welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm nominal size (Recycled Aggregate (RA), including necessary excavation of size 250x250x450mm deep forthe same in bitumen/ concrete pavement at specified spacing. [Rate] |
| 467 | [6.8.2]Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 2. 40mm thick [Through Rate] |
| 468 | [7.103.1.1]Stone tile work for wall lining up to 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade. 1.1. 8mm thick (mirror polished and machine cut edge)Granite stone of any colour and shade [Through Rate] |
| 469 | [7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate] |
| 470 | [7.21.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate] |
| 471 | [7.22.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate] |
| 472 | [7.28.2]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) [Through Rate] |
| 473 | [8.16]Providing and fixing of reconstituted stone tile work (IS 3622-2017-Reaffirmed) for wall Cladding up to 10 m height with special adhesive (IS 15477-2019) over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade. [Through Rate] |
| 474 | [8.19.1]Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : 1. Decorative veneer facings of approved manufacture [Through Rate] |
| 475 | [8.24.2]Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface. 2. 25 mm thick [Through Rate] |
| 476 | [8.24.4]Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface. 4. 12 mm thick [Through Rate] |
| 477 | [8.26.2.2]Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shade Area of slab over 0.50 sqm [Through Rate] |
| 478 | [8.27.2]Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 2. Granite work [Through Rate] |
| 479 | [8.28]Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. [Through Rate] |
| 480 | [9.10.1]Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 1. With residual type petroleum bitumen of grade VG -10 [Through Rate] |
| 481 | [9.17.1]Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase [Through Rate] |
| 482 | [9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. [Through Rate] |
| 483 | [9.51.1]Providing and fixing false ceiling at all height including providing and fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I channels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture`s specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with: 1. 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fibre manufactured through autoclaving process. [Through Rate] |
| 484 | [9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter [Through Rate] |
| 485 | [9.58.1.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.2. Coupler 110 mm [Through Rate] |
| 486 | [9.58.4.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 4.2. Single tee without door 110x110x110 mm [Through Rate] |
| 487 | [9.58.5.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5° 110 mm bend [Through Rate] Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysSep 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender