Tender For Shifting Of Electrical Utility For Newly Proposed Pmgsy - Iii Scheme From (I) Chowmuhani Bazar To Juricherra(5.4Km), (Ii) Mdf Road At Kanchanbari To Demdum(5.8Km) & (Iii) Jagannathpur To Telia Via Jagannathpur H.S. School(6.59Km) Under Ed
Tender Overview
Project Description
Tender for Shifting Of Electrical Utility For Newly Proposed Pmgsy - Iii Scheme From (I) Chowmuhani Bazar To Juricherra(5.4Km), (Ii) Mdf Road At Kanchanbari To Demdum(5.8Km) & (Iii) Jagannathpur To Telia Via Jagannathpur H.S. School(6.59Km) Under Ed - Kumarghat.
BOQ
| Sl. No. | Item Description |
| 1 | Supply of Steel Tubular Pole 9.0 mtr long |
| 2 | Supply of Steel Tubular Pole 8.0 mtr long |
| 3 | Supply of Steel Tubular Pole 11.0 mtr long |
| 4 | Supply of ACSR Weasal (6 / 1 / 2.59 mm) |
| 5 | Supply of ACSR Dog (6 / 7 / 4.72 / 1.57 mm) |
| 6 | Supply of Polymeric Pin insulator with G. I. Pin for 11 KV system |
| 7 | Supply of 11 KV Polymer Composite 45 KN Disc Insulator |
| 8 | Supply of 11 KV Disc Fittings |
| 9 | Supply of Shackle Insulator |
| 10 | Supply of LT AERIAL BUNCHED CABLE 3 X 50 + 1 X 16 + 1 X 35 sq. mm |
| 11 | Supply of LT AERIAL BUNCHED CABLE 3 X 70 + 1 X 16 + 1 X 35 sq. mm |
| 12 | Supply of ACCESSORIES OF LT AERIAL BUNCHED CABLE Service Anchor Clamp (18 - 50 mm) |
| 13 | Supply of ACCESSORIES OF LT AERIAL BUNCHED CABLE Dead end Clamp (25 - 35 mm) |
| 14 | Supply of ACCESSORIES OF LT AERIAL BUNCHED CABLE - Pole clamp (25 / 50 mm) |
| 15 | Supply of ACCESSORIES OF LT AERIAL BUNCHED CABLE - Eye Hook |
| 16 | Supply of ACCESSORIES OF LT AERIAL BUNCHED CABLE 3-Ph. Dist. Box (25 - 50 mm) |
| 17 | Supply of ACCESSORIES OF LT AERIAL BUNCHED CABLE IPC Main 16 - 95 Sq. mm & Tap 4 to 35 (50) Sq. mm |
| 18 | Supply of PVC CABLES (SINGLE CORE) 4 sq. mm |
| 19 | Supply of 4 inch N & B |
| 20 | Supply of M.S Channel 75 X 40 x 40 X 6 mm (Galvanised) |
| 21 | Supply of M.S Angle 65 X 65 X 6 mm (Galvanised) |
| 22 | Supply of Stay set complete |
| 23 | Supply of H.T. stay insulator |
| 24 | Supply of GI Stay wire stranded stay wire |
| 25 | Supply of XLPE Cable 11 KV , 3C x 95 sq.mm |
| 26 | Dismantling of Single Conductor ACSR 6 / 1 / 2.59 mm dia WEASEL including Coiling etc. Complete as required. |
| 27 | Dismantling of IKM (Single Conductor) ACSR 6 / 7 / 4.72 / 1.57 mm dia DOG including coiling etc. Complete as required. |
| 28 | Dismantling of 8.0 mtrs length of P.C.C POLE at any kind of soil including excavation of earth refilling the pit with soil upto the ground level ramming and making complete in all respect |
| 29 | Dismantling of 9.0 mtrs length of P.C.C POLE at any kind of soil including excavation of earth,refilling the pit with with soil upto the ground level, ramming and making complete in all respect. |
| 30 | Dismantling of 9.0 mtrs length of Steel Tubular POLE at any kind of soil , including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect. |
| 31 | Dismantling of 11.0 mtrs length of Steel Tubular POLE at any kind of soil including excavation of earth refilling the pit with soil upto the ground level ramming and making complete in all respect |
| 32 | Dismantling of 11 KV Pin insulator along with Pin. |
| 33 | Dismantling of 11 KV Single Disc insulator set along with necessary fittings. |
| 34 | Dismantling of M.S.ChanneI Cross-Arm,1.3 Mtr. Long 75 X 40 X 40 X 6 mm |
| 35 | Dismantling of M.S.ChanneI Cross-Arm, 1.7 Mtr. Long 75 X 40 X 40 X 6 mm |
| 36 | Dismantling of M.S.AngIe Cross-Arm, 2.1 Mtr. Long 65 X 65 X 6 mm |
| 37 | Dismantling of M.S. Channel Cross-Arm, 0.3 to 1.2 Mtr long 75X 40 X 40 X 6 mm |
| 38 | Dismantling of M.S.Channel Cross-Arm, 0.3 to 1.6 Mtr. Long 75X 40 X 40 X 6 mm |
| 39 | Dismantling of M.S.AngIe Cross-Arm, 1.7 Mtr. Long 65 x65 x 6 mm |
| 40 | Dismantling of M.S.Angle Cross-Arm bracket of 2 wire 0.55 Mtr. Long of 50 X 50 X 6 mm / 65 X 65 X 6 mm |
| 41 | Dismantling Single Phase Service Connection with PVC cable from nearby Electrical pole to Premises i/c. G.I. Wire, Reel Insulator |
| 42 | Dismantling Three Phase Service Connection with PVC cable from nearby Electrical pole to Premises i/c. G.I.Wire, Reel Insulator |
| 43 | Dismantling of Stay set from the earth complete with 19 mm x 1800 mm long stay rod, anchor plate of size 300 x 300 x 8 mm ,thimble, turn buckle, 7 / 3.15 mm dia G.I Standed stay wire and stain insulator etc. and making complete in all respect. |
| 44 | Dismantling of AB Cable 3 X 50 + 1 X 16 - 25 + 1 X 35 - 50 sq. mm of 101 KV grade as per direction of Engineering In-Charge. |
| 45 | Dismantling of AB Cable 3 X 70 + 1 X 16 - 25 + 1 X 35 - 50 sq. mm of 101 KV grade as per direction of Engineering In-Charge. |
| 46 | Dismantling of Service main 1 / 3 - Phase distribution Box of 1.1 KV grade as per direction of Engineering In-Charge. |
| 47 | Dismantling of Insulated suspention Clamp including Pole clamp, Eye hook as per direction of Engineering In-Charge. |
| 48 | Dismantling of Insulated Dead end enchoring Clamp including Pole clamp, Eye hook asper direction of Engineering In-Charge. |
| 49 | Dismantling of shackle insulator with straps & bolts / U clamp on poles |
| 50 | Erection of 9.0 mtrs length of Steel Tubular POLE at any kind of soil , including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect. |
| 51 | Erection of 8.0 mtrs length of Steel Tubular POLE at any kind of soil , including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect. |
| 52 | Erection of 11.0 mtrs length of Steel Tubular POLE at any kind of soil , including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect. |
| 53 | Erection of 8.0 mtrs length of P.C.C POLE at any kind of soil including excavation of earth refilling the pit with soil upto the ground level ramming and making complete in all respect. |
| 54 | Erection of 9.0 mtrs length of P.C.C POLE at any kind of soil including excavation of earth refilling the pit with soil upto the ground level ramming and making complete in all respect. |
| 55 | Erection of 11 KV Pin insulator along with Pin |
| 56 | Erection of 11 KV Single Disc insulator set along with necessary fittings |
| 57 | Erection of M.S. Channel Cross-Arm, 1.3 to 2.8 Mtr long 75 X 40 X 40 X 6 mm (Excluding cost of Back Clamp, Nuts & Bolts) |
| 58 | Erection of M.S. Channel Cross-Arm, 1.3 to 2.8 Mtr long 75 X 40 X 40 X 6 mm (Excluding cost of Back Clamp, Nuts & Bolts) |
| 59 | Erection of M.S. Angle Cross-Arm, 1.0 to 2.5 Mtr long 65 X 65 X 6 mm (Excluding cost of Back Clamp, Nuts & Bolts) |
| 60 | Erection of M.S. Channel Cross-Arm, 0.3 to 1.2 Mtr long 75 X 40 X 40 X 6 mm (Excluding cost of Back Clamp, Nuts & Bolts) |
| 61 | Erection of M.S. Channel Cross-Arm, 1.3 to 2.8 Mtr long 75 X 40 X 40 X 6 mm (Excluding cost of Back Clamp, Nuts & Bolts) |
| 62 | Erection of M.S. Angle Cross-Arm, 1.0 to 2.5 Mtr long 65 X 65 X 6 mm (Excluding cost of Back Clamp, Nuts & Bolts) |
| 63 | Erection of M.S. Angle Cross-Arm Bracket of 2 wire upto 1.10 Mtr. Long of 50 X 50 X 6 mm / 65 X 65 X 6 mm |
| 64 | Providing Single Phase Service Connection with laying PVC cable from nearby Electrical pole to Premises upto 35 mtr, in length supported by G.I.Wire, Reel Insulator i/c fitting fixing of Energy Meter as required |
| 65 | Providing Three Phase Service Connection with laying PVC cable from nearby Electrical pole to Premises upto 35 mtr. in length supported by G.I.Wire, Reel Insulator i/c fitting fixing of Energy Meter as required |
| 66 | Erection of Stay set direct in earth complete with 1 9mm x 1800 mm long stay rod, anchor plate of size 300 x 300 x 8 mm ,thimble, turn buckle, 7 / 3.15 mm dia G.I Standed stay wire and stain insulator etc. with Supply of M.S.Clamp, Nuts & Bolts etc. as required. and making complete in all respect |
| 67 | Positioning of cable drum, removing of cable fromdrum and Laying, hoisting & drawing of AB Cable 3 X 50 + 1 X 16 - 25 + 1 X 35 - 50 sq. mm of 101 KV gradeas per direction of Engineering In-Charge. |
| 68 | Positioning of cable drum, removing of cable fromdrum and Laying, hoisting & drawing of AB Cable 3 X 70 + 1 X 16 - 25 + 1 X 35 - 50 sq. mm of 101 KV gradeas per direction of Engineering In-Charge. |
| 69 | Erection of shackle insulator with straps & bolts/U clamp on poles (Excluding the cost of straps / U clamp, nuts & Bolts) |
| 70 | Fitting-Fixing of Service main 1 / 3 - Phase distribution Box of 1.1 KV grade on PCC / Steel Pole with the help Pole brackets or Steel Straps & buckIes as per direction of Engineering In-Charge. |
| 71 | Erection & Fitting-Fixing of Insulated suspention Clamp including Pole clamp, Eye hook for cable massenger of 1.1 IV grade on PCC / Steel Pole with the help Pole brackets or Steel Straps & buckIes as per direction of Engineering In-Charge. |
| 72 | Erection & Fitting-Fixing of Insulated Dead end enchoring Clamp including Pole clamp, Eye hook for cable massenger of 1.1 KV grade on PCC / Steel Pole with the help Pole brackets or Steel Straps & buckIes as per direction of Engineering In-Charge. |
| 73 | Laying and Stringing of 1 KM (Single Conductor) ACSR 6 / 1 / 2.59 mm dia WEASEL including hoisting and binding etc. complete as required. |
| 74 | Laying & Stringing of 1 KM (Single Conductor) ACSR 6 / 7 / 4.72 / 1.57 mm dia DOG including hoisting & KM binding etc. Complete as required. |
| 75 | Laying of one number PVC insulated and PVC sheathed / XLPE Power Cable of 11 KV Grade of following size direct in ground including excavation, sand cushioning, protective covering and re-filling the trenche etc. As required.Trench size: Width - 350 mm, Height - 1200 mm / Sand (Cushioning: Height - 250 mm, Width - 350 mm / Protection: Double layer Bricks Up to 120 sq.mm |
| 76 | Laying of one number PVC insulated and PVC sheathed / XLPE Power Cable of 11 KV Grade of all size in the GI pipe / HDPE for Riser including tie up of pipe with pole by the help of MS Flat Clamp (Excluding cost of clamp and nut & bolts) as required Up to 400 sq.mm |
| 77 | Coiling of excess single / three core / 31/2 core up to 400 sq.mm, HV / MV, XLPE insulated, armoured Power Cable direct in to earth including excavation of earth up to a depth of 1500 mm (Size pit should be 2250 mm X 2250 mm of as as per site requirement) including first class brick protection of two layer flat Brick soiling, 300 mm Fine Sand (Local quary) for cushioning / bed and re-filling and ramming the excavated soil as per direction of Engineer-in-charge. |
| 78 | Providing of pre-cast cement concrete cable identification Route Marker (1 Cement : 2 Coarse Sand : 4 Graded Stone aggregate 6 mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1 : 3 (1 Cement : 3 Fine Sand) etc. complete, excluding the plastering of jambs, sills and soffits as per design, drawing and specification of TSECL. The marker shall be embossed \\"DANGER\\": TSECL. 11KV POWER CABLE\\" with black colour latter (both side). The visible part shall be painted with yellow colour Japan Paint (1 Cement : 2 Coarse Sand : 4 Graded Stone aggregate 6 mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1 : 3 (1 Cement : 3 Fine Sand) etc. complete, excluding the plastering of jambs, sills and soffits. |
| 79 | Supplying and Making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as requiredUp to 150sqmm |
| 80 | Febrication of Cross-Arms by MS Channel / MS Angle as per specification |
| 81 | Grouting of Steel Tubular PCC Pole of ratio 1:2:4 (1cement:2 riversand:4 Jhama brick Aggregate of 20mm. Nominal size) including supply of cement, sand and brick aggregate. Complete with excavation, refilling of each, ramming along with centering and shuttering as required |
| 82 | Supply of PN8, PE-100 GRADE, 110 mm OD, minimum wall thickness 7.3 HDPE Pipe |
| 83 | Supply of febricated clamps of assorted size of MS flat (50 X 6 mm) with double coat of red oxide primer coating ( Which will be used in various bracket & clamping of cables ) |
| 84 | Supply of M.S.Nuts & Bolt i/c Washer of assortedsize ISI Marked machine made( 5'' x 5/1/2\\" & 16\\" long ) |
| 85 | Carriage of dismantle materials by machanical transport from work site to Sub-Divisional store yard including loading, unloading and stacking etc as required [ Upto the lead range 25 KM ] Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender