Power Government Departments Closing in 8 days TDR #57246877

Tender For Shifting Of Electrical Utility For Newly Proposed Pmgsy - Iii Scheme From (I) Chowmuhani Bazar To Juricherra(5.4Km), (Ii) Mdf Road At Kanchanbari To Demdum(5.8Km) & (Iii) Jagannathpur To Telia Via Jagannathpur H.S. School(6.59Km) Under Ed

Issued by Government Departments · Unakoti, Tripura
Tender Value
73.68 Lakhs
Estimated cost
Bid Submission
10 Sep 2026
8 days left
EMD
1.47 Lakhs
Bank guarantee accepted
Document Fee
9440
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Unakoti → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Shifting Of Electrical Utility For Newly Proposed Pmgsy - Iii Scheme From (I) Chowmuhani Bazar To Juricherra(5.4Km), (Ii) Mdf Road At Kanchanbari To Demdum(5.8Km) & (Iii) Jagannathpur To Telia Via Jagannathpur H.S. School(6.59Km) Under Ed - Kumarghat.

BOQ

Name of Work:- Shifting of Electrical Utility for newly proposed PMGSY – III Scheme from (i) Chowmuhani Bazar to Juricherra(5.4Km), (ii) MDF Road at Kanchanbari to Demdum(5.8Km) & (iii) Jagannathpur to Telia Via Jagannathpur H.S. School(6.59Km) under ED – Kumarghat.
Sl. No. Item Description
1Supply of Steel Tubular Pole 9.0 mtr long
2Supply of Steel Tubular Pole 8.0 mtr long
3Supply of Steel Tubular Pole 11.0 mtr long
4Supply of ACSR Weasal (6 / 1 / 2.59 mm)
5Supply of ACSR Dog (6 / 7 / 4.72 / 1.57 mm)
6Supply of Polymeric Pin insulator with G. I. Pin for 11 KV system
7Supply of 11 KV Polymer Composite 45 KN Disc Insulator
8Supply of 11 KV Disc Fittings
9Supply of Shackle Insulator
10Supply of LT AERIAL BUNCHED CABLE 3 X 50 + 1 X 16 + 1 X 35 sq. mm
11Supply of LT AERIAL BUNCHED CABLE 3 X 70 + 1 X 16 + 1 X 35 sq. mm
12Supply of ACCESSORIES OF LT AERIAL BUNCHED CABLE Service Anchor Clamp (18 - 50 mm)
13Supply of ACCESSORIES OF LT AERIAL BUNCHED CABLE Dead end Clamp (25 - 35 mm)
14Supply of ACCESSORIES OF LT AERIAL BUNCHED CABLE - Pole clamp (25 / 50 mm)
15Supply of ACCESSORIES OF LT AERIAL BUNCHED CABLE - Eye Hook
16Supply of ACCESSORIES OF LT AERIAL BUNCHED CABLE 3-Ph. Dist. Box (25 - 50 mm)
17Supply of ACCESSORIES OF LT AERIAL BUNCHED CABLE IPC Main 16 - 95 Sq. mm & Tap 4 to 35 (50) Sq. mm
18Supply of PVC CABLES (SINGLE CORE) 4 sq. mm
19Supply of 4 inch N & B
20Supply of M.S Channel 75 X 40 x 40 X 6 mm (Galvanised)
21Supply of M.S Angle 65 X 65 X 6 mm (Galvanised)
22Supply of Stay set complete
23Supply of H.T. stay insulator
24Supply of GI Stay wire stranded stay wire
25Supply of XLPE Cable 11 KV , 3C x 95 sq.mm
26Dismantling of Single Conductor ACSR 6 / 1 / 2.59 mm dia WEASEL including Coiling etc. Complete as required.
27Dismantling of IKM (Single Conductor) ACSR 6 / 7 / 4.72 / 1.57 mm dia DOG including coiling etc. Complete as required.
28Dismantling of 8.0 mtrs length of P.C.C POLE at any kind of soil including excavation of earth refilling the pit with soil upto the ground level ramming and making complete in all respect
29Dismantling of 9.0 mtrs length of P.C.C POLE at any kind of soil including excavation of earth,refilling the pit with with soil upto the ground level, ramming and making complete in all respect.
30Dismantling of 9.0 mtrs length of Steel Tubular POLE at any kind of soil , including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect.
31Dismantling of 11.0 mtrs length of Steel Tubular POLE at any kind of soil including excavation of earth refilling the pit with soil upto the ground level ramming and making complete in all respect
32Dismantling of 11 KV Pin insulator along with Pin.
33Dismantling of 11 KV Single Disc insulator set along with necessary fittings.
34Dismantling of M.S.ChanneI Cross-Arm,1.3 Mtr. Long 75 X 40 X 40 X 6 mm
35Dismantling of M.S.ChanneI Cross-Arm, 1.7 Mtr. Long 75 X 40 X 40 X 6 mm
36Dismantling of M.S.AngIe Cross-Arm, 2.1 Mtr. Long 65 X 65 X 6 mm
37Dismantling of M.S. Channel Cross-Arm, 0.3 to 1.2 Mtr long 75X 40 X 40 X 6 mm
38Dismantling of M.S.Channel Cross-Arm, 0.3 to 1.6 Mtr. Long 75X 40 X 40 X 6 mm
39Dismantling of M.S.AngIe Cross-Arm, 1.7 Mtr. Long 65 x65 x 6 mm
40Dismantling of M.S.Angle Cross-Arm bracket of 2 wire 0.55 Mtr. Long of 50 X 50 X 6 mm / 65 X 65 X 6 mm
41Dismantling Single Phase Service Connection with PVC cable from nearby Electrical pole to Premises i/c. G.I. Wire, Reel Insulator
42Dismantling Three Phase Service Connection with PVC cable from nearby Electrical pole to Premises i/c. G.I.Wire, Reel Insulator
43Dismantling of Stay set from the earth complete with 19 mm x 1800 mm long stay rod, anchor plate of size 300 x 300 x 8 mm ,thimble, turn buckle, 7 / 3.15 mm dia G.I Standed stay wire and stain insulator etc. and making complete in all respect.
44Dismantling of AB Cable 3 X 50 + 1 X 16 - 25 + 1 X 35 - 50 sq. mm of 101 KV grade as per direction of Engineering In-Charge.
45Dismantling of AB Cable 3 X 70 + 1 X 16 - 25 + 1 X 35 - 50 sq. mm of 101 KV grade as per direction of Engineering In-Charge.
46Dismantling of Service main 1 / 3 - Phase distribution Box of 1.1 KV grade as per direction of Engineering In-Charge.
47Dismantling of Insulated suspention Clamp including Pole clamp, Eye hook as per direction of Engineering In-Charge.
48Dismantling of Insulated Dead end enchoring Clamp including Pole clamp, Eye hook asper direction of Engineering In-Charge.
49Dismantling of shackle insulator with straps & bolts / U clamp on poles
50Erection of 9.0 mtrs length of Steel Tubular POLE at any kind of soil , including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect.
51Erection of 8.0 mtrs length of Steel Tubular POLE at any kind of soil , including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect.
52Erection of 11.0 mtrs length of Steel Tubular POLE at any kind of soil , including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect.
53Erection of 8.0 mtrs length of P.C.C POLE at any kind of soil including excavation of earth refilling the pit with soil upto the ground level ramming and making complete in all respect.
54Erection of 9.0 mtrs length of P.C.C POLE at any kind of soil including excavation of earth refilling the pit with soil upto the ground level ramming and making complete in all respect.
55Erection of 11 KV Pin insulator along with Pin
56Erection of 11 KV Single Disc insulator set along with necessary fittings
57Erection of M.S. Channel Cross-Arm, 1.3 to 2.8 Mtr long 75 X 40 X 40 X 6 mm (Excluding cost of Back Clamp, Nuts & Bolts)
58Erection of M.S. Channel Cross-Arm, 1.3 to 2.8 Mtr long 75 X 40 X 40 X 6 mm (Excluding cost of Back Clamp, Nuts & Bolts)
59Erection of M.S. Angle Cross-Arm, 1.0 to 2.5 Mtr long 65 X 65 X 6 mm (Excluding cost of Back Clamp, Nuts & Bolts)
60Erection of M.S. Channel Cross-Arm, 0.3 to 1.2 Mtr long 75 X 40 X 40 X 6 mm (Excluding cost of Back Clamp, Nuts & Bolts)
61Erection of M.S. Channel Cross-Arm, 1.3 to 2.8 Mtr long 75 X 40 X 40 X 6 mm (Excluding cost of Back Clamp, Nuts & Bolts)
62Erection of M.S. Angle Cross-Arm, 1.0 to 2.5 Mtr long 65 X 65 X 6 mm (Excluding cost of Back Clamp, Nuts & Bolts)
63Erection of M.S. Angle Cross-Arm Bracket of 2 wire upto 1.10 Mtr. Long of 50 X 50 X 6 mm / 65 X 65 X 6 mm
64Providing Single Phase Service Connection with laying PVC cable from nearby Electrical pole to Premises upto 35 mtr, in length supported by G.I.Wire, Reel Insulator i/c fitting fixing of Energy Meter as required
65Providing Three Phase Service Connection with laying PVC cable from nearby Electrical pole to Premises upto 35 mtr. in length supported by G.I.Wire, Reel Insulator i/c fitting fixing of Energy Meter as required
66Erection of Stay set direct in earth complete with 1 9mm x 1800 mm long stay rod, anchor plate of size 300 x 300 x 8 mm ,thimble, turn buckle, 7 / 3.15 mm dia G.I Standed stay wire and stain insulator etc. with Supply of M.S.Clamp, Nuts & Bolts etc. as required. and making complete in all respect
67Positioning of cable drum, removing of cable fromdrum and Laying, hoisting & drawing of AB Cable 3 X 50 + 1 X 16 - 25 + 1 X 35 - 50 sq. mm of 101 KV gradeas per direction of Engineering In-Charge.
68Positioning of cable drum, removing of cable fromdrum and Laying, hoisting & drawing of AB Cable 3 X 70 + 1 X 16 - 25 + 1 X 35 - 50 sq. mm of 101 KV gradeas per direction of Engineering In-Charge.
69Erection of shackle insulator with straps & bolts/U clamp on poles (Excluding the cost of straps / U clamp, nuts & Bolts)
70Fitting-Fixing of Service main 1 / 3 - Phase distribution Box of 1.1 KV grade on PCC / Steel Pole with the help Pole brackets or Steel Straps & buckIes as per direction of Engineering In-Charge.
71Erection & Fitting-Fixing of Insulated suspention Clamp including Pole clamp, Eye hook for cable massenger of 1.1 IV grade on PCC / Steel Pole with the help Pole brackets or Steel Straps & buckIes as per direction of Engineering In-Charge.
72Erection & Fitting-Fixing of Insulated Dead end enchoring Clamp including Pole clamp, Eye hook for cable massenger of 1.1 KV grade on PCC / Steel Pole with the help Pole brackets or Steel Straps & buckIes as per direction of Engineering In-Charge.
73Laying and Stringing of 1 KM (Single Conductor) ACSR 6 / 1 / 2.59 mm dia WEASEL including hoisting and binding etc. complete as required.
74Laying & Stringing of 1 KM (Single Conductor) ACSR 6 / 7 / 4.72 / 1.57 mm dia DOG including hoisting & KM binding etc. Complete as required.
75Laying of one number PVC insulated and PVC sheathed / XLPE Power Cable of 11 KV Grade of following size direct in ground including excavation, sand cushioning, protective covering and re-filling the trenche etc. As required.Trench size: Width - 350 mm, Height - 1200 mm / Sand (Cushioning: Height - 250 mm, Width - 350 mm / Protection: Double layer Bricks Up to 120 sq.mm
76Laying of one number PVC insulated and PVC sheathed / XLPE Power Cable of 11 KV Grade of all size in the GI pipe / HDPE for Riser including tie up of pipe with pole by the help of MS Flat Clamp (Excluding cost of clamp and nut & bolts) as required Up to 400 sq.mm
77Coiling of excess single / three core / 31/2 core up to 400 sq.mm, HV / MV, XLPE insulated, armoured Power Cable direct in to earth including excavation of earth up to a depth of 1500 mm (Size pit should be 2250 mm X 2250 mm of as as per site requirement) including first class brick protection of two layer flat Brick soiling, 300 mm Fine Sand (Local quary) for cushioning / bed and re-filling and ramming the excavated soil as per direction of Engineer-in-charge.
78Providing of pre-cast cement concrete cable identification Route Marker (1 Cement : 2 Coarse Sand : 4 Graded Stone aggregate 6 mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1 : 3 (1 Cement : 3 Fine Sand) etc. complete, excluding the plastering of jambs, sills and soffits as per design, drawing and specification of TSECL. The marker shall be embossed \\"DANGER\\": TSECL. 11KV POWER CABLE\\" with black colour latter (both side). The visible part shall be painted with yellow colour Japan Paint (1 Cement : 2 Coarse Sand : 4 Graded Stone aggregate 6 mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1 : 3 (1 Cement : 3 Fine Sand) etc. complete, excluding the plastering of jambs, sills and soffits.
79Supplying and Making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as requiredUp to 150sqmm
80Febrication of Cross-Arms by MS Channel / MS Angle as per specification
81Grouting of Steel Tubular PCC Pole of ratio 1:2:4 (1cement:2 riversand:4 Jhama brick Aggregate of 20mm. Nominal size) including supply of cement, sand and brick aggregate. Complete with excavation, refilling of each, ramming along with centering and shuttering as required
82Supply of PN8, PE-100 GRADE, 110 mm OD, minimum wall thickness 7.3 HDPE Pipe
83Supply of febricated clamps of assorted size of MS flat (50 X 6 mm) with double coat of red oxide primer coating ( Which will be used in various bracket & clamping of cables )
84Supply of M.S.Nuts & Bolt i/c Washer of assortedsize ISI Marked machine made( 5'' x 5/1/2\\" & 16\\" long )
85Carriage of dismantle materials by machanical transport from work site to Sub-Divisional store yard including loading, unloading and stacking etc as required [ Upto the lead range 25 KM ] Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57246877
AUTHORITY Government Departments
TENDER VALUE 73.68 Lakhs
LAST DATE 10-09-2026
Authority
Authority Name Tripura State Electricity Corporation Limited
Work Description Tender for Shifting Of Electrical Utility For Newly Proposed Pmgsy - Iii Scheme From (I) Chowmuhani Bazar To Juricherra(5.4Km), (Ii) Mdf Road At Kanchanbari To Demdum(5.8Km) & (Iii) Jagannathpur To Telia Via Jagannathpur H.S. School(6.59Km) Under Ed - Kumarghat.
Basic Detail
Tender No DGM/ED/KGT/2026-27/01
Bidding Type Tender
Location
City Unakoti
State Tripura
Key Dates
Publish Date 29 Aug 2026
Submission Date 10 Sep 2026
Open Date 10 Sep 2026
Finance
Tender Value 73.68 Lakhs
Tender Fee 9440
EMD 1.47 Lakhs
Exemption Not Available
Document List
b1f2274c-53b4-4fa3-8855-672983e80a01.html
BOQ_77849.xls
Tendernotice_1 (22).pdf
Tendernotice_2 (4).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Sep 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

b1f2274c-53b4-4fa3-8855-672983e80a01.html

xls

BOQ_77849.xls

pdf

Tendernotice_1 (22).pdf

pdf

Tendernotice_2 (4).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders