Tender For Maintenance Of Mi Scheme Under Jirania Rd Block During The Year 2026-27 / Sh:- Repair & maintenance Of Pump-Motor , Suction-Delivery & Electrical Accessories Etc. (Job No. Tr/17/Minor Works/Wrd-I/2026-27)
Tender Value
5.67 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
8 days left
EMD
11349
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Maintenance Of Mi Scheme Under Jirania Rd Block During The Year 2026-27 / Sh:- Repair & maintenance Of Pump-Motor , Suction-Delivery & Electrical Accessories Etc. (Job No. Tr/17/Minor Works/Wrd-I/2026-27)
BOQ
| Sl. No. | Item Description |
| 1 | Dismentling of pump for over hauling including greasing, gland packing, necessary repairs & reinstallation of the same including trial run for 10 hrs. in two spell complete as per direction of the Engineer-in-Charge.i) For LI |
| 2 | Supply & fitting fixing ball bearing of approved quality for pump required during overhauling.i) 6306 Ball bearing (TATA /SKF) |
| 3 | Providing & fitting fixing Shaft sleeve bush of approved quality.i) For LIa) Cast iron |
| 4 | Providing & fitting fixing Shaft sleeve nut of approved quality.i) Cast iron |
| 5 | Providing & fitting fixing C.I. gland of approved quality.i) For LI |
| 6 | Providing & fitting fixing C.I coupling complete with nuts & bolts of approved quality.i) 150 mm dia |
| 7 | Providing & fitting fixing coupling nuts & bolts (all Size)of approved quality.i) For LI |
| 8 | Providing & fitting fixing coupling rubber bush (All Size)of approved quality. i) For LI |
| 9 | Providing & fitting fixing coupling star bush (All Size) of approvedquality.i) 150 mm dia |
| 10 | Providing & fitting fixing Pump Shaft of approved quality. |
| 11 | Supplying and fitting fixing of asbestos rope of best quality as per direciton of Engineer-in-charge. i) 6mm to 8mm thick |
| 12 | ii) 10 to 12 mm thick |
| 13 | Providing & fitting fixing Casing ring of approved quality.i) 150 mm diaa) 10 mm thick |
| 14 | Providing & fitting fixing Lantern Ring for pump of approved quality. |
| 15 | Supplying and greasing/applying of grease of approved quality as per direction of Engineer-in-charge. |
| 16 | Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.a) 150 mm dia |
| 17 | Providing & fitting fixing Shaft sleeve nut of approved quality.i) Cast iron |
| 18 | Providing & fitting fixing of G.I. flange ( 10 mm wall thickness ) by welding with G.I. / MS pipe and placing position as per specification and the direction of the Engineer-in- charge.i) 150 mm dia |
| 19 | Providing & fitting fixing Gland nut / Stag nut 100 mm long for gland of approved quality.i) For LI |
| 20 | Providing and fitting fixing M.S. clamp for hose pipes with nuts & bolts complete as per relevant IS specification and direction of Engineer-in-charge.i) 150mm dia |
| 21 | Providing & fitting fixing Rubber flange washer 6 mm thick at site of work of approved quality.i)150 mm dia |
| 22 | Providing and fitting fixing MS Foot valve as per relevant IS specification and the direction of the Engineer-in-charge.i) 150 mm dia |
| 23 | Providing & fitting fixing C.I tail piece of approved quality at site of work.i) 150 mm dia |
| 24 | Providing & fitting fixing foot valve leather washer (6 mm thick) of heavy duty at site of work of approved quality.ii) 150 mm dia |
| 25 | Providing & fitting fixing C.I foot valve spare parts of 125/150 mm dia at site of work of approved quality.A) C.I foot valve weight |
| 26 | B) C.I foot valve ring |
| 27 | C) C.I foot valve net |
| 28 | Dismantling of motor for vernishing heating etc cpmplete in/c reinstalltion and trail run for two spell complete as per direction of the engineer-in charge. |
| 29 | Supplying & fitting fixing of spare parts for 20/25 HP Horizontal motor.A) Motor fan |
| 30 | B) Terminal plate |
| 31 | Providing and fitting fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415v, 25HP /18.50 kw Relay range within 17-25 ) in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for motor Pump Havells/L & T/BCH make direction of the Engineer-in-charge. |
| 32 | Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses). Triple pole with Neutral Link ( TPN ) , 415/500 Volt complete as per direction of the Engineer-in charge.a) Current range 63 Amps |
| 33 | b) 200 amps |
| 34 | Providing & fitting fixing PVC suction hose pipe overall thickness 5mm of best quality at site of work (Pankaj made) of approved quality.i)150 mm dia |
| 35 | Providing & fixing 200 amps busbar of size 600x450x100 mm with 4 nos copper strip of size 450x40x4 mm of approved quality |
| 36 | Supplying and fitting fixing 7/16 PVC shethed copper wire with all electrical equipments in/c trial run etc. complete (ISI marked) on the panel board of approved. |
| 37 | Providing and fixing C.I non return valve of approved quality as per CPWD specification and direction of the Engineer in charge. i) 125 mm dia nominal bore |
| 38 | Supplying and fitting fixing of submerssible cable(copper) of size upto 12mm of approved quality as per direction of the Engineer in charge. |
| 39 | Supplying and fitting fixing kit cut for main & sub main switch (Male & Female) as per direction of the Engineer in charge.i) 63 amps main switch |
| 40 | ii) 100 amps main switch |
| 41 | iii) 200 amps main switch |
| 42 | Providing and fitting fixing of moving iron type, Range 0-500 V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the Engineer-incharge. |
| 43 | Supplying and fitting fixing of 3 pole power conductors of different type, range from 25-300 AC-3 suitable for Fully Automatic Star Delta type Motor startar L&T , BCH, Havells make as per direction of Engineer-in-Charge. |
| 44 | Providing and fitting fixing of moving iron type, Range 0- 100/0-200 amps, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. |
| 45 | Supplying and fitting fixing of Thermal overload Relay, relay range 20-32, & 28-42, directly operated suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in-Charge. |
| 46 | Rewinding of Horizontal Motor suitable for centrifugal pumps by complete dismantling in/c providing & rewinding with Super enamelled copper conductor (as per IS : 13730 Part-3 ) conductor & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as perspecification and direction of the Engineer-in-charge.a) 20 HP |
| 47 | b) 25-30 HP |
| 48 | Labour charge of lifting of 5,000 to 20,000 GPH water lubricated vertical submersible pump with motor including column assembly upto 100 feet with heavy duty chain pulley and block as per direction of the Engineer-in-charge. |
| 49 | Repair and maintenance of 15 HP / 17.5 HP Motor suitable for 7500 GPH capacity submerssible pumpset by complete dismantling in/c providing & fitting fixing of PVC ( IS : 8783- 1978 ) insulated electro grade copper ( IS : 613-1984 ) conductor winding in stator & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge. |
| 50 | Labour charge for lowering & fifting fixing of 5,000 to 20,000 GPH water lubricated vertical submersible pump with motor including column assembly upto 100 feet with heavy duty chain pulley and block and making necessary electrical connection with main switch /starter with motor in/c trial run for 10 hrs in two spell complete as per direction of the Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysSep 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer