Housing Urban and Rular Development Government Departments Closing in 6 days TDR #57246775

Tender For Construction Work Of Integrated Public Health Laboratory (Iphl) Under Pm-Abhim At Sonamura Sub- Divisional Hospital At Melaghar, Sepahijala District, Tripura / Providing Internal Electrification Of Thereof./ Providing Internal Electrificat

Issued by Government Departments · Sepahijala, Tripura
Tender Value
3.37 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
6 days left
EMD
6752
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sepahijala → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Work Of Integrated Public Health Laboratory (Iphl) Under Pm-Abhim At Sonamura Sub- Divisional Hospital At Melaghar, Sepahijala District, Tripura / Providing Internal Electrification Of Thereof./ Providing Internal Electrification Along With Installation Of Starter And Panel Installation For Ahu & Vrf At The New Integrated Public Health Laboratory (Iphl) Under Pm-Abhim At Sub- Divisional Hospital At Melaghar, Sonamura, Sepahijala District, Tripura.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 27-Aug-2026 CORRIGENDUM Date 07-Sep-2026

BOQ

Name of Work:- Construction work of Integrated Public Health Laboratory (IPHL) under PM-ABHIM at Sonamura Sub- Divisional Hospital at Melaghar, Sepahijala District, Tripura / Providing Internal Electrification of thereof./ Providing Internal Electrification along with installation of starter and panel installation for AHU & VRF at the new Integrated Public Health Laboratory (IPHL) under PM-ABHIM at Sub- Divisional Hospital at Melaghar, Sonamura, Sepahijala District, Tripura.
Sl. No. Item Description
1Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/ 415 volts MCB/ Isolator/ RCCB (SP/ SPN/ DP/TP /TPN /FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.
24 way vertical TPN MCB DB suitable for FP MCCB incomer upto 250 amps (Double door):-
3Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:
440/50/63 amps TPN MCB:-
5Supplying, installation, testing & commissioning of powder coated prewired panel board suitable for 415 volts TP MCCB as incomer & outgoing including busbar & connection as required of the following ratings & sizes:-
66 way TP MCCB outgoing & TP MCCB incomer upto 400 amps:-
7Supplying, installation, testing & commissioning of powder coated prewired digital meter module complete with ammeter, voltmeter, phase indicator lamp, control fuses, CTs, in the existing panel board including connection etc. as required:-
8Supplying, installation, testing & commissioning of powder coated side cable module (1 pair) in the existing panel board including connection etc. as required suitable for the following sizes and ratings:-
94/6 way outgoing and incomer upto 400 amps :-
10Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):-
1116 to 100 amps FP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):-
12200 amps TP MCCB, Breaking capacity 25KA (Thermal Magnetic) :-
13Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-
14Short Point :-
15Medium Point :-
16Long Point :-
17Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
18Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
19Earthing with Copper earth plate 600 mm x 600 mm x 3 mm thick i/c accessories and providing masonry enclosure with CI cover plate Size 12\\"x 12\\" having locking arrangement, along with 20 mm dia (medium gauge) watering pipe including CC work etc as required
20Extra for using salt (12 kg) and charcoal (96kg) for plate earth electrode as required
21Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for loop earthing as required.
22Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required.
23Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.
242 x 1.5 sq.mm:-
252 x 2.5 sq.mm:-
262 x 4 sq.mm:-
272 x 6 sq.mm:-
284 x 6 sq.mm:-
294 x 10 sq.mm:-
304 x 16 sq.mm:-
314 x 25 sq.mm:-
32Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/ surface including connection etc. as required.
331 x 1.5 sq.mm:-
341 x 2.5 sq.mm:-
351 x 4 sq.mm:-
362 x 1.5 sq.mm:-
372 x 2.5 sq.mm:-
382 x 4 sq.mm:-
392 x 6 sq.mm:-
404 x 10 sq.mm:-
414 x 16 sq.mm:-
424 x 25 sq.mm:-
43Supplying, Installation of DOL starter MK2, 3 Phase ,415 V,50 Hz relay range upto 20-32 Amps along with necessary connection and Installation complete in all respect.
44Supplying, Installation of DOL starter MK1, 3 Phase ,415 V,50 Hz relay range upto 9-14 Amps along with necessary connection and Installation complete in all respect.
45Supplying, Installation of DOL starter MU-Automatic DOL starter (MU-1 HA DOL, 3 Phase ,415 V,50 Hz relay range upto 20-32 Amps along with necessary connection and Installation complete in all respect.
46Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-
47Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):-
48Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-
4918/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):-
509 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :-
51Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-
5260 watt LED street light fixture with integral driver and secondary lens (IP 66):-
53Supplying and fixing of the following modular accessories including necessary connection etc. as required.
545 step fan regulator (2M):-
55Blank plate (1M):-
56Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W).
57Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:-
58Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: -
592.5 sqmm
604 sqmm
6110 sqmm
6216 sqmm
6325 sqmm
64Supplying and fixing of following i/c connection as required.
651\\" flexible pipe( Present Market rate):-
66PVC coupler 40mm/ 32mm( Present Market rate):-
67Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-
6840 mm dia:-
69Supplying and fixing of M.S Box size (12\\"x8\\"x6\\") made of 3 mm size MS sheet with an arrangement of fittingMCB SP and Neutral link i/c rubber Gasket to the cover, water outlet duct to the below and locking arrangement.
70Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required:-
713 core 4 sq mm:-
724 core 120 sq mm:-
73Drawing of armoured/un-armoured cable with proper saddling etc as required:-
74Supplying and fixing of 'Fire Shield' brand ISI marked CO2 type Fire Extinguisher 2 KG capacity to IS: 15683: 2006 made from seamless cylinder conforming to IS: 7285 fitted with ISI marked controlled valve conforming to IS: 3224, discharge adopter and horn complete with initial gas charged with carrying handle and wall mounting Bracket suitable for operating between -30 degree centigrade to +55 degree centigrade, Fire rating class- 8B in/c necessary connection etc as required:-
75Supplying and fixing of the following electrical accessories including necessary connection etc. as required.
76Ding dong call bell
7732 amps DP kit kat switch:
78Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : -
79120 sq mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57246775
AUTHORITY Government Departments
TENDER VALUE 3.37 Lakhs
LAST DATE 07-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Work Of Integrated Public Health Laboratory (Iphl) Under Pm-Abhim At Sonamura Sub- Divisional Hospital At Melaghar, Sepahijala District, Tripura / Providing Internal Electrification Of Thereof./ Providing Internal Electrification Along With Installation Of Starter And Panel Installation For Ahu & Vrf At The New Integrated Public Health Laboratory (Iphl) Under Pm-Abhim At Sub- Divisional Hospital At Melaghar, Sonamura, Sepahijala District, Tripura.
Basic Detail
Tender No EE-IED/UDP/08/2026-27
Bidding Type Tender
Location
City Sepahijala
State Tripura
Key Dates
Publish Date 27 Aug 2026
Submission Date 07 Sep 2026
Open Date 07 Sep 2026
Finance
Tender Value 3.37 Lakhs
Tender Fee 1000
EMD 6752
Exemption Not Available
Document List
BOQ_77743.xls
cb551dd0-88ac-4523-8831-78e42f947274.html
EDNIT.pdf
Tendernotice_1 (22).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 6 days
Sep 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.