Housing Urban and Rular Development Government Departments Closing in 6 days TDR #57246742

Tender For Providing I.E Work For Installation 125 Kva Rating Capacity, 415 Volt 3 Phase, Amf Panel Including Necessary Connection Etc. As Required And Other Electrical Installation For Generator Procurement Of 01 (One) Dg Set With Construction Of Re

Issued by Government Departments · Gomati, Tripura
Tender Value
21.80 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
6 days left
EMD
43610
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gomati → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing I.E Work For Installation 125 Kva Rating Capacity, 415 Volt 3 Phase, Amf Panel Including Necessary Connection Etc. As Required And Other Electrical Installation For Generator Procurement Of 01 (One) Dg Set With Construction Of Reinforced Cement Concrete Basement At Udaipur District Jail, Gomati, Tripura.

BOQ

Name of Work:- Providing I.E work for installation 125 KVA rating capacity, 415 volt 3 phase, AMF Panel including necessary connection etc. as required and other electrical installation for Generator procurement of 01 (one) DG set with Construction of RCC basement at Udaipur District Jail, Gomati, Tripura.
Sl. No. Item Description
1Supply and installation of 125 KVA rating capacity, 415 volt 3 phase silent Generator set (CPCB IV compliant) diesel engine 4K1080ETA4G1,156 BHP at 1500 rpm 4 cylinder radiator cooled coupler with 125 KVA/100 KW,415 V, 0.8 PF,50HZ,mounted on a common base plate along with \\"A\\" type control panel with auto start auto stop(STD) provision, AMF Panel,MF battery with leads,inbuilt fuel tank,AVM pads, Acoustic enclosure including necessary connection etc as required. (KIRLOSKAR GREEN/ Mahindra powerol) DG SET
2Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required
34 core 185 Sq mm
4Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : -
5185 sq mm
6Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per direction of Site Engineer :-
7Drawing of armoured/un-armoured cable with proper saddling etc as required:-
8Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:-
9300/320 amps kitkat porcelain fuse unit with base(rewireable) with extended strip:-
10Earthing with Copper earth plate 600 mm x 600 mm x 3 mm thick i/c accessories and providing masonry enclosure with CI cover plate Size 12\\"x 12\\" having locking arrangement, along with 20 mm dia (medium gauge) watering pipe including CC work etc as required:-
11Extra for using salt (12 kg) and charcoal (96kg) for plate earth electrode as required.
12Providing and laying 15 mm dia (medium guage) G.I pipe for drawing of 4.06 mm (8SWG) dia G.I/Copper wire for earth connection from earth electrodes etc. as required.
13Supply and fixing of 25mm x 3mm Copper on walls/ floor of the building for horizontal/ vertical network including necessary spacers and porcelain insulators at regular intervals.
14Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.
152 x 1.5 sq.mm:-
162 x 2.5 sq.mm:-
174 x 25 sq.mm:-
184 x 35 sq.mm:-
19Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/ surface including connection etc. as required.
201 x 1.5 sq.mm:-
211 x 2.5 sq.mm:-
224 x 25 sq.mm:-
234 x 35 sq.mm:-
24Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):-
25320 amps FP MCCB, Breaking capacity 36KA (Thermal Magnetic) :-
26Supplying and installation of powder coated steel sheet enclosure for 415 volts MCCB (TP/FP) complete with necessary connection etc as required:-
27Enclosure suitable for MCCB above 250 amps upto 400 amps:-
28Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:-
29Earth work in excavation by mechanical means(hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.-All kinds of soil.
30Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
31Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -all work upto plinth level-1:4:8 ( 1 Cement: 4 fine sand : 8 graded stone aggregate 40 mm nominal size)-
32Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-all work upto plinth level-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size).
33Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size).
34Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size).
35Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. (considering 100kg/cum of concrete-item no- 20)
36Centering shuttering including struttings, propping etc. and removal of form work for:
37Foundations, footings, bases for columns etc. for mass concrete with timber plank
38Lintels, beams, plinth beams, girders, bressumers and cantilevers with wooden plank.
39Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply.
40Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:-In grating, frames, guard bar, railing, brackets, gates and similar works, all complete.
41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Two or more coats on new work over an under coat of suitable shade with ordinary paint (primer) of approved brand and manufacture.
42Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required etc. complete as per direction of Engineer-in-charge. 0.63mm thick with zinc coating not less than 275gm/m2
4312 mm cement plaster of mix. Cement mortar 1:4 (1 cement : 4 fine sand) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57246742
AUTHORITY Government Departments
TENDER VALUE 21.80 Lakhs
LAST DATE 07-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Providing I.E Work For Installation 125 Kva Rating Capacity, 415 Volt 3 Phase, Amf Panel Including Necessary Connection Etc. As Required And Other Electrical Installation For Generator Procurement Of 01 (One) Dg Set With Construction Of Reinforced Cement Concrete Basement At Udaipur District Jail, Gomati, Tripura.
Basic Detail
Tender No EE-IED/UDP/09/2026-27
Bidding Type Tender
Location
City Gomati
State Tripura
Key Dates
Publish Date 27 Aug 2026
Submission Date 07 Sep 2026
Open Date 07 Sep 2026
Finance
Tender Value 21.80 Lakhs
Tender Fee 1000
EMD 43610
Exemption Not Available
Document List
54aa4a94-4166-4f96-8b5b-dffff5660152.html
BOQ_77752.xls
EDNIT.pdf
Tendernotice_1 (22).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

54aa4a94-4166-4f96-8b5b-dffff5660152.html

xls

BOQ_77752.xls

pdf

EDNIT.pdf

pdf

Tendernotice_1 (22).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender