Tender For Construction Of Auditorium Of Radhakrishanan Medical College Hamirpur (Hp) (Sh:- Supply, Installation, Testing and Commissioning Dg 500 Kva Therein)
Tender Value
1.39 Crore
Estimated cost
Bid Submission
07 Sep 2026
7 days left
EMD
2.79 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Una → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Auditorium Of Radhakrishanan Medical College Hamirpur (Hp) (Sh:- Supply, Installation, Testing and Commissioning Dg 500 Kva Therein)
BOQ
| Sl. No. | Item Description |
| 1 | Supplying, Installing, Testing and Commissioning of ‘Silent Type’ Diesel Generating set alongwith having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and coforming to CPCB IV+ Norms.(Rate shall include the testing of DG set at factory using resistive load for 12 hours at full load and further 1 hour at 10% overload ) Note : DG set shall be compatible for Synchronization ,Parallel operation,interlocking and also compatible for BMS,integration The DG set Canopy and AMF Panel should be DG set OEM Manufatured only. |
| 2 | Diesel Engine: |
| 3 | Diesel engine, 4 stroke water cooled radiator, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation.The engine should be radiator cooled .The engine will be confirm to ISO 8528 specification and should mee latest CPCB IV+ NORMS complete fitted complete with all the required accessories.Make :- Kirloskar,Cummins,, Ashok leyland,caterpiller,volvo penta,perkins,mitsubishi. |
| 4 | Engine mounted Instrument Panel fitted with and having digital display for following: |
| 5 | (i) Start-stop switch with key |
| 6 | (ii) Water temperature indication |
| 7 | (iii) Lubrication oil pressure indication |
| 8 | (iv) Lubrication oil temperature indication |
| 9 | (v) Battery charging indication |
| 10 | (vi) RPM indication |
| 11 | (vii) Over speed indication |
| 12 | (viii) Low lub. Oil trip indication |
| 13 | (ix) Engine Hours indication |
| 14 | (X) Turbo charger |
| 15 | Alternator : |
| 16 | Synchronous rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class- F/H insulation. The voltage regulation shoud be +-1 %. The alternator should be of Stamford, Kirloskar,Leroysomer,Mitsubishi,Caterpiller make only |
| 17 | Acoustic Encloure Base Frame & Foundation: |
| 18 | Specially desigined to meet stringent MoEF/CPCB-IV+ norms of < 75 dBA @ 1 mtr at 75% load under free conditions. The acoustic enslosure is made CRCA sheets in munsel green shade and structural/sheet base fame painted in black high quality noise absorbant and fire-retardant grade acoustic insulation material (P.U foam) complying to IS 8183. Both the engine and alternator shall be mounted on suitable base frame made of MS channel The foundation shoud be designed safe bearing capacity of soil.Cement concrete 1:3:6(1 cement:3 coarse sand:6 graded stone aggregate 40 mm nominal size) The depths of Plain cement concrete foundation is minimum 600 mm and foundation height should be at least 300 mm above the ground level. The length and breadth of foundation should be at least 250 mm more on all sides than the size of enclosure.The Gen set should be mounted on Anti vibration isolation arrangement as per recommendations of manufacturer. |
| 19 | Fuel Tank: |
| 20 | Daily service fuel tank of 850 liters capacity(as per OEM) fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. There should be provision of fuel tank of fuel guage ,which should be show the level of the fuel even when the DG set is not running . the guage should be calibrated .The fuel tank should be filled from the outside as in automobiles and should be with a lockable cap. Complete with valves, level indications & accessories as required as per specifications. |
| 21 | Starting system |
| 22 | 12/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitablewith suitable no of batteries as per OEM recommendations. |
| 23 | Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere.There should be 2 nos 10 watt LED tubes provided inside the enclosure controlled by a 5 amp switch for adequate lighting during service.The power supply to this luminaire should be load side of the AMF panel. as per specifications. |
| 24 | Exhaust System: |
| 25 | Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor.complete in all respect as required. |
| 26 | Annual maintenance contract of 500 KVA DG SET Through OEM for five years including two year warranty period consisting of monthly visit to check the general condition of generator. Check and set operation parameters as specified by company. One Service in year for five year including consumable materials .check and monitor the performs during each visit.To check & ensure optimum performance of sub assembles of machine, fuel timming, tappet clearance etc, for engines and reset the same as require. To check & set all the fasteners, operation of warning devices, operational parameters of breakdown of engines..if any breakdown occure in dg set ,the breakdown should be check & rectify within 24 hour/minimum time period by service engineer. |
| 27 | Supplying and fixing true power make advanced earthing system having pure copper pipe 3 meter long 50 mm dia with terminal size 50x6 mm ,internal strip size 25x3 with 50 Kg compound including exvation of pit and refiling the same and making earthing pit cover 12 inch dia as required complete in all respect. make :- True power ,Earth plus,Ashloka or its equivalent as per best satisfaction of Engineer-in -charge. |
| 28 | Supplying and laying 25 mm X 5 mm copper strip on surface as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 29 | Providing, laying and fixing of PVC round sheathed 6 core 2.5 sqmm copper conductor flexible cable for voltage grade up to 1100 volt , as required complete in all respect. Make :-Finolex/Havell/Polycab/KEI |
| 30 | Supplying and fixing of following sizes of PVC conduit having heavy class along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.Diplast/BEC/Polyfitas approved by Er-In-Charge |
| 31 | 25 mm |
| 32 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation and refilling the trench including,lugs, glands etc as required, but excluding sand cushioning and protective covering.Make:-KEI,Havells, Finolex as approved by Er-in-charge |
| 33 | Armoured cable 300 sq. mm (3.5 core) |
| 34 | Provding and refilling of diesel for 500 KVA complete in all respect . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysSep 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender