Housing Urban and Rular Development Government Departments Closing in 0 days TDR #57246432

Tender For Repair And Restoraretion Of Hl Bridge -(B) Over Mahanadi River At Mirzeipur On Pratapnagari-Athanga Road Under Kataka (R&B) Division-Ii For The Year 2024-25.

Issued by Government Departments · Cuttack, Odisha
Tender Value
77.89 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
0 days left
EMD
77900
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Cuttack → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Restoraretion Of Hl Bridge -(B) Over Mahanadi River At Mirzeipur On Pratapnagari-Athanga Road Under Kataka (R&B) Division-Ii For The Year 2024-25.

BOQ

Name of Work:- Repair and Restoraretion of HL Bridge -(B) over Mahanadi River at Mirzeipur on Pratapnagari-Athanga Road under Kataka (R&B) Division-II for the year 2024-25.
Sl. No. Item Description
1Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge.(75 mm average thickness)
250 mm average thickness
3Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge.
4Providing and applying of anticorrosive treatment to exposed structural reinforcement by two coats of IPNET RB or equivalent with time interval of minimum 8 -10 hours between each coat after the application of two coats of alkaline rust converting primer. The application shall be done by brush or spray after cleaning existing reinforcement with wire / rotary wire brush to make the surfaces free from loose material, dirt, traces of corrosion etc. and thoroughly washing with water and allowing it to dry inclusive of all labour, materials, equipment etc. complete in all respect as per specifications and instructions of Engineer in Charge.
5Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.(Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make)
6Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.(Up to 12 mm diameter (Quantity taken for estimate purpose approximately. Quantity may vary as per actual work) @ 50Rmt per span))
7Bars above 12 mm diameter (Quantity taken for estimate purpose approximately. Quantity may vary as per actual work) @ 50 Rmt per span)
8Shotcreting R.C.C. columns, beams, and slab etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge. Note: Rate shall be include the providing necessary ground wire etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.(75 mm thick in Grade M 25 with cement content not less than 330 kg per cum)
9Providing and fixing hard drawn steel wire fabric of size 75 x 25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of \\"L\\"shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by the Engineer-In-Charge.
10Providing , mixing and applying SBR polymer (of approved make) modified cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and payment under this item shall be made only after proper wet curing has been done and surface has been satisfactory evaluated by sounding / tapping with a blunt metal instrument and/ or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N /mm2 .(50mm thickness in 3 Layers)
11Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
12Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
13Providing and laying in position ready mixed or site batched design mix M15 grade cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural source, Portland Pozzolona/Ordinary Portland / Portland Slag cement, admixture in recommended proportions as per IS:9103 to accelerate /retard setting of concrete , to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing , carriage for all leads; but excluding the cost of cantering , shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
14Providing & Laying Design M-40 grade concrete (Note : Min. Cement content considered in M-40 is @ 390 kg/ cum)(For approach slab )
15Centering and shuttering including strutting, propping etc. and removal of form work for :
16Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
17Providing and laying of neoprene seal in expansion joint for horizontal movement, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation complete work.
18Providing and fixing in position and level Elastomeric bearings of size 320 mm x 450 x 80 mm thick confirming to IRC:83 (Part-II) complete with all respect and as per drawing/as directed by Engineer-in-charge.
19Lifting of Span i.e. Superstructure of Bridge for Replacement of old Bearings and including all higher and running expenses of all plants, Hydraulic jacks, Power Packs, Generator set ,welding machines and equipments. All works shall be according to the general specifications of roads and bridges and as directed by the engineer-in-charge.
20Providing and fixing drainage spouts complete as per IRC: SP-42 with 100 mm dia PVC pipe and down-take length 1m as per engineer-in-charge.
21Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acrylonitrile) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degrees to base .The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873 part 4: 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge.
22Providing and painting of Anticorrosive paint on exposed surface of superstructures and complete as per specifications and manufacture's recommendation by approved supplier as per the direction of Engineer-in-Charge.
23Cleaning and removing vegetation as and where required.
24Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diameter (20mm to 30mm) up to depth 30mm to 80mm at required spacing making the hole & cracks dust free by blowing compressed air , sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-in-charge.
25Providing and injecting grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete / masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-charge. (Epoxy Injection grout in concrete/RCC work of approved make.)
26Providing and placing high strength, non shrink pre-packed free flow micro concrete having compressive strength of 60 MPa at 28 days (compressive strength of one day should not be less than 25 MPa) as per specifications. The micro concrete mix shall be prepared by mixing non shrink pre-packed free flow micro concrete powder with well graded cleaned crushed, aggregate 10mm & down (aggregate should be less than 10mm but retained on 3.36mm) in proportion of 2:1 (Two part pre-pack micro concrete powder : one part stone aggregate) by weight for repairing excessively damaged area of structural elements excluding reinforcement but including scaffolding, curing inclusive of all labour, materials, equipment etc. complete as per specifications and instructions of Engineer-in-Charge.
27Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.
28Providing and fixing retro reflecting sign board.
29Providing and applying stone pitching as per drawing/engineer in charge.
30Providing and applying cement grout in stone masonry about 100mm thick complete work as per drawing/engineer in charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57246432
AUTHORITY Government Departments
TENDER VALUE 77.89 Lakhs
LAST DATE 07-09-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Repair And Restoraretion Of Hl Bridge -(B) Over Mahanadi River At Mirzeipur On Pratapnagari-Athanga Road Under Kataka (R&B) Division-Ii For The Year 2024-25.
Basic Detail
Tender No SE-KATAKA RAND DIV II-08/2026-27
Bidding Type Tender
Location
City Cuttack
State Odisha
Key Dates
Publish Date 28 Aug 2026
Submission Date 07 Sep 2026
Open Date 08 Sep 2026
Finance
Tender Value 77.89 Lakhs
Tender Fee 10000
EMD 77900
Exemption Not Available
Document List
BOQ_607451.xls
cefaf630-826c-4a72-a2bb-8e4417f7ef5f.html
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_607451.xls

html

cefaf630-826c-4a72-a2bb-8e4417f7ef5f.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders