Educational and Research Institute Boards / Undertakings / PSU Closing in 4 days TDR #57245918

Tender For Replacement Of Defective Cooling Tower With New Cooling Towers (350 Tr X 02Nos.) And Modification Of Pipelines Connected To Water Cooled Chiller Ac Plant At Faculty Of Dentistry, Jamia Millia Islamia

Issued by Boards / Undertakings / PSU · Delhi, Delhi
Tender Value
24.89 Lakhs
Estimated cost
Bid Submission
19 Sep 2026
4 days left
EMD
49790
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Defective Cooling Tower With New Cooling Towers (350 Tr X 02Nos.) And Modification Of Pipelines Connected To Water Cooled Chiller Ac Plant At Faculty Of Dentistry, Jamia Millia Islamia

BOQ

Name of Work:- Replacement of defective cooling tower with new cooling towers (350 Tr X 02Nos.) and Modification of pipelines connected to water cooled chiller AC plant at Faculty of Dentistry, Jamia Millia Islamia
Sl. No. Item Description
1DSR E&M Item 2025
2HVAC(ONLY PLUMBING,DUCTING &AHU)
3INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gaugesetc.) duly insulated with following closed cell elastomeric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia andabove.
4200mm dia.(32 mm thick insulation)
5150mm dia. (32 mm thick insulation)
6INSULATED VALVES : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as perspecifications.
7BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation asspecified
8200mm dia.
9150mm dia.
10Cooling Towers
11Supplying, Installation, testing and commissioning of Induced Draft counterflow cooling Towers(CTI approved). The Cooling Tower shall be of Fiber Reinforced Plastic (FRP) Construction. The casing, basin/sump, fan deck and fan cylinder shall be of FRP, with direct driven fans, Galvanised hardware complete with sump and drain connection with suitable valve, PVC Honey comb fill, louvers, drift eliminator complete with spray nozzle having self rotating sprinklers, steel ladder, Isolating switch and other accessories to make it fully operational and maintaince National Accreditation Board for Testing and Calibration Laboratories (NABL) & positioning of cooling tower at Terrace of Building. Propeller Type Fan, weather proof IP 55 and Direct driven.The fan motor shall be premium efficiency IE3 class , as per IS 12615 The Cooling tower shall be capable to communicate effectively with Building Management System (BMS). Range of CT: 6 0C. Designed Duty Conditions :- EWT, LWT , D/WBT Complete as per CPWD specification/drawings and as directed by Engineer-incharge. ( Note - Cooling tower size depends on the ambient temperature conditions , contractor must check the required design temperature).
121050 GPM (Buy-bacy Item each existing Cooling Tower of Rs. 100000.00) DSR Amount is 1021370 - 100000 = 921370
13Non Schedule Items
14Dismantling of Old Cooling Tower including removing the scarp from site and cleaning of site,Dismantling of Old Channel, Supply and Installation of New C channel , Making frame by welding and cutting of C channel with support plates for Cooling tower base frame chanel L - 13' , W - 8', Labour charges for dismantling of old defective pipeline, cutting, with gas cutter, removal with heavy labour etc. as perdirection of Engineer in-charge.
15Supply and Installation of MS But-elbow heavy class size - 200mm.
16Supply and Installation of MS FLANGE SIZE 200 MM
17Supply and Installation of MS FLANGE SIZE 150 MM
18Note:- Rates are all inclusive of GST, contractor's profit and Cartage. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57245918
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 24.89 Lakhs
LAST DATE 19-09-2026
Authority
Authority Name Jamia Millia Islamia
Work Description Tender for Replacement Of Defective Cooling Tower With New Cooling Towers (350 Tr X 02Nos.) And Modification Of Pipelines Connected To Water Cooled Chiller Ac Plant At Faculty Of Dentistry, Jamia Millia Islamia
Basic Detail
Tender No JMI/BD/E-NIT/No.10/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 28 Aug 2026
Submission Date 19 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 24.89 Lakhs
Tender Fee 500
EMD 49790
Exemption Not Available
Document List
Agreement.pdf
BOQ_966879.xls
fd17465d-a1cf-4079-85eb-1e93cde2e683.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
pdf

Agreement.pdf

xls

BOQ_966879.xls

html

fd17465d-a1cf-4079-85eb-1e93cde2e683.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender