Tender For Replacement Of Defective Cooling Tower With New Cooling Towers (350 Tr X 02Nos.) And Modification Of Pipelines Connected To Water Cooled Chiller Ac Plant At Faculty Of Dentistry, Jamia Millia Islamia
Tender Value
24.89 Lakhs
Estimated cost
Bid Submission
19 Sep 2026
4 days left
EMD
49790
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacement Of Defective Cooling Tower With New Cooling Towers (350 Tr X 02Nos.) And Modification Of Pipelines Connected To Water Cooled Chiller Ac Plant At Faculty Of Dentistry, Jamia Millia Islamia
BOQ
| Sl. No. | Item Description |
| 1 | DSR E&M Item 2025 |
| 2 | HVAC(ONLY PLUMBING,DUCTING &AHU) |
| 3 | INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gaugesetc.) duly insulated with following closed cell elastomeric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia andabove. |
| 4 | 200mm dia.(32 mm thick insulation) |
| 5 | 150mm dia. (32 mm thick insulation) |
| 6 | INSULATED VALVES : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as perspecifications. |
| 7 | BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation asspecified |
| 8 | 200mm dia. |
| 9 | 150mm dia. |
| 10 | Cooling Towers |
| 11 | Supplying, Installation, testing and commissioning of Induced Draft counterflow cooling Towers(CTI approved). The Cooling Tower shall be of Fiber Reinforced Plastic (FRP) Construction. The casing, basin/sump, fan deck and fan cylinder shall be of FRP, with direct driven fans, Galvanised hardware complete with sump and drain connection with suitable valve, PVC Honey comb fill, louvers, drift eliminator complete with spray nozzle having self rotating sprinklers, steel ladder, Isolating switch and other accessories to make it fully operational and maintaince National Accreditation Board for Testing and Calibration Laboratories (NABL) & positioning of cooling tower at Terrace of Building. Propeller Type Fan, weather proof IP 55 and Direct driven.The fan motor shall be premium efficiency IE3 class , as per IS 12615 The Cooling tower shall be capable to communicate effectively with Building Management System (BMS). Range of CT: 6 0C. Designed Duty Conditions :- EWT, LWT , D/WBT Complete as per CPWD specification/drawings and as directed by Engineer-incharge. ( Note - Cooling tower size depends on the ambient temperature conditions , contractor must check the required design temperature). |
| 12 | 1050 GPM (Buy-bacy Item each existing Cooling Tower of Rs. 100000.00) DSR Amount is 1021370 - 100000 = 921370 |
| 13 | Non Schedule Items |
| 14 | Dismantling of Old Cooling Tower including removing the scarp from site and cleaning of site,Dismantling of Old Channel, Supply and Installation of New C channel , Making frame by welding and cutting of C channel with support plates for Cooling tower base frame chanel L - 13' , W - 8', Labour charges for dismantling of old defective pipeline, cutting, with gas cutter, removal with heavy labour etc. as perdirection of Engineer in-charge. |
| 15 | Supply and Installation of MS But-elbow heavy class size - 200mm. |
| 16 | Supply and Installation of MS FLANGE SIZE 200 MM |
| 17 | Supply and Installation of MS FLANGE SIZE 150 MM |
| 18 | Note:- Rates are all inclusive of GST, contractor's profit and Cartage. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender