Defence Government Departments Closing in 6 days TDR #57245907

Tender For Annual Repair And Maintenance Of Air Conditioners Installed At Various Locations Under Bsf Academy Gwalior (For The Year 2026-27)

Issued by Government Departments · Gwalior, Madhya Pradesh
Tender Value
15.34 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
6 days left
EMD
30699
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gwalior → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Annual Repair And Maintenance Of Air Conditioners Installed At Various Locations Under Bsf Academy Gwalior (For The Year 2026-27)

BOQ

Name of Work:- Annual Repair and maintenance of Air conditioners installed at various locations under BSF Academy Gwalior (for the year 2026-27)
Sl. No. Item Description
1High pressure cleaning of various capacity Window / Split / Tower AC of all size by using high pressure water jet cleaning machine mixing of cleaning agents and AL-Cleanoil coil cleaning chemical altra shine i/c sundries and transportation charges of AC mechanic as required.
2Onsite technical inspection for R/M of various capacity Window / Split / Tower AC of all size by AC mechanic with all required testing tools, Dismentling of defective PCB/ fan motor/ compressor/ capacitor/ contactor/ defective circuit/card and identification of fault i/c removal of defective part and deposit in engneering store i/c transportation charges of AC mechanic as required.
3Supplying and replacement of suitable capacity /size of fan motor for 1.5 ton / 2.0 ton Split/Tower AC including connecetion and testing etc as per requirement. ( Make : Carrier/LG/Voltas/Same specification make)
4Supplying and replacement of fan blade suitable for 1.5 ton / 2.0 ton Window/Split/Tower AC including fitting and testing etc as per requirement. ( Make : Carrier / LG / Voltas / Same specification make)
5Supplying and replacement of blower motor suitable for 1.5 ton /2.0 ton Window/Split/Tower AC including fitting and testing etc as per requirement. ( Make : Carrier/LG/Voltas/ Same specification)
6Rewinding of fan motor i/c replacement of bush/bearing, shaft, oiling & greasing as reqd. for 1.5 ton /2.0 ton Split / Tower AC including connecetion and testing etc
7Supplying and replacement i/c dismentling and installation of PCB Circuit suitable for 1.5 ton /2.0 ton capacity as per requirement.
8Testing/repiring i/c dismentling and installation of PCB Circuit suitable for 1.5 ton /2.0 ton capacity as per requirement.
9Providing and installation i/c dismentling if required wall mounted outdoor stand suitable for 1.5 ton /2.0 ton capacity split air conditioner outdoor as per requirement.
10Providing fixing/ replacement of heating /cooling sensor suitable for 1.5 ton /2.0 ton Window/Split/Tower AC as per requirement. ( Make : Carrier/LG/Voltas/Same specification make)
11Supplying and fixing of Air filter suitable for 1.5 ton /2.0 ton Window/Split/Tower AC as per requirement. ( Make : Carrier / LG / Voltas / Same specification make)
12Supplying and replacement of 50 MFD capacitor suitable for compressor of 1.5/ 2.0 Ton Window / Split / Tower AC making all connection & earthing. ( make : Havells/epcos/Tibcon)
13Supplying and replacement of capacitor 2.5 MFD /4 MFD/6 MFD suitable for 1.5 ton /2.0 ton capacity Split / window / Tower AC as per requirement (make : Havells/epcos/Tibcon)
14SITC of 1.5 ton capacity compressor including suitable gas charging pipe welding etc as per requirement Compressor make : kirloskar/blue star/toshiba/hitachi/LG/Emerson/Danfoss
15SITC of 2.0 Ton capacity compressor including suitable gas charging pipe welding etc as per requirement Compressor make : kirloskar/blue star/toshiba/hitachi/LG/Emerson/Danfoss
16Supplying and filling of fresh refrigerant (R-22/R-410/R-32 etc) suitable for 1.5 ton/2.0 ton air conditioner as per requirement including Testing and Repair of leakage of 1.5 ton /2.0 ton capacity window/split/tower AC unit. etc as required
17Supplying and fixing of single phase contactor suitable for 1.5 ton /2.0 ton AC as per requirement
18Supplying and fixing of outdoor heating coil suitable for 1.5 ton capacity window/split/tower AC as per requirement
19Supplying and fixing of outdoor heating coil suitable for 2.0 ton capacity window/split/tower AC as per requirement
20Providing and replacement of suitable capacity /size of outdoor fan motor for 1.5/2 ton Split duct AC including connection and testing etc as per requirement.
21Suppling and replacement of Filter Drier suitable for fixing in line with 5.5 ton compressor including fitting and testing etc as per requirement.
22Supplying and replacement of Expansion valve suitable for fixing in line with 5.5 ton compressor including fitting and testing etc as per requirement.
23Rewinding of outdoor fan coil unit motor i/c replacement of bush, shaft, oiling & greasing as reqd. for Split duct AC including connecetion and testing etc
24SITC of 5/5.5 ton capacity compressor including suitable gas charging etc as per requirement of make Kirloskar/bluestar/toshiba/hitachi/LG/Emerson/Danfoss
25Providing and fixing of three phase contactor suitable for split Duct AC as per requirement
26Providing and fixing of NO & NC Add-on block suitable for split Duct AC as per requirement
27SITC of 12 ton capacity compressor including suitable gas charging etc as per requirement make : kirloskar/blue star /toshiba /hitachi/LG/Emerson/Danfoss
28Providing and replacement of Filter Drier suitable for fixing in line with 12 Ton compressor including fitting and testing etc as per requirement.
29Supplying and replacement of Expansion valve suitable for fixing in line with 12 ton compressor including fitting and testing etc as per requirement.
30Providing and filling of Nitrogen gas cylinder for checking of leakage (7 cum capacity)
31Supplying and fixing 4-core 2.5 sq mm PVC insulated & PVC sheathed with bare annealed copper conductor flexibles cables of Polycab make.
32SITC of one indoor handler unit with suitable parametres for operation on 230+- 10% volt ,50 Hz single phase AC supply including copper evaporator for 2-ton split type air conditioners of Carrier /Voltas/Bluestar or its eqt make.
33Supply and fixing of 25 mm flexible drain pipe suitable for drain out the waste water of air conditioners of of ISI marked premium quality.
34Providing of miscellaneous items for repair maintenance of AC's
35Brazing Rod
36Gas Torch/can
37Valve 3/8
38Dead nut
39Copper pipe of 1/2 & 1/4 with insulation
40Insulation 9 mm thick 2 mtr long
41Packing Tape (2\\" width length 25-50 mtr) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57245907
AUTHORITY Government Departments
TENDER VALUE 15.34 Lakhs
LAST DATE 07-09-2026
Authority
Authority Name Border Security Force
Work Description Tender for Annual Repair And Maintenance Of Air Conditioners Installed At Various Locations Under Bsf Academy Gwalior (For The Year 2026-27)
Basic Detail
Tender No 31/5403/NIT/ENGG/ELECT/2026-27
Bidding Type Tender
Location
City Gwalior
State Madhya Pradesh
Key Dates
Publish Date 28 Aug 2026
Submission Date 07 Sep 2026
Open Date 08 Sep 2026
Finance
Tender Value 15.34 Lakhs
Tender Fee Ref. Documents
EMD 30699
Exemption Not Available
Document List
b11941b2-436c-4a4f-9b82-7514a445c975.html
BOQ_970975.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

b11941b2-436c-4a4f-9b82-7514a445c975.html

xls

BOQ_970975.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders