Tender For Emergent Work For Converstion From Lt Oh Line To Under Ground Cable Alongwith Connected Accessories Of Hq Igar (E)
Tender Value
1.50 Crore
Estimated cost
Bid Submission
10 Sep 2026
8 days left
EMD
3.02 Lakhs
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Cachar → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Emergent Work For Converstion From Lt Oh Line To Under Ground Cable Alongwith Connected Accessories Of Hq Igar (E)
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE ‘A’ PART-I ( Road Work) |
| 2 | Supply and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required upto 35 sq. mm |
| 3 | Supply and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required but above 35 sq. mm and upto 95 sq. mm |
| 4 | Supply and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required but above 95 sq. mm and upto 120 sq. mm |
| 5 | Supply test & commissioning LT UG cable XLPE insulated sheathed and armoured, with aluminium stranded conductor, LT 1100 Volts grade of size 25 sqmm 3.5 core, complete all as specified and as directed. |
| 6 | All as per item No 4 above, but 35 sqmm 3.5 core |
| 7 | All as per item No 4 above, but 50 sqmm 3.5 core |
| 8 | All as per item No 4 above, but 70 sqmm 3.5 core |
| 9 | All as per item No 4 above, but 95 sqmm 3.5 core |
| 10 | All as per item No 4 above, but 120 sqmm 3.5 core Note for Item No 4 to 9 : (i) Earth work excavation, sand filling, bricks for cable protection,GI pipe and PCC work will be measured and paid saperatly under relevant items.(ii) Old rusted/ damaged electric pole should be removed from site safely carryover and deposit to Engr store yard |
| 11 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 12 | Supply & laying GI pipe medium grade 80 mm dia for cable protection undr road/culverts etc complete all as specified and as directed. |
| 13 | Supply & laying GI pipe medium grade 50 mm dia for cable protection undr road/culverts etc complete all as specified and as directed. |
| 14 | Supply & laying GI pipe light grade 40 mm dia incl MS clamps along the pole for protection of under ground cable as required complete all as specified and as directed. |
| 15 | M&L for cutting/ dismantling of floors/ walls etc for laying or passing under ground cables, including provision of PCC 1:2:4 type B-2 using 40 mm graded stone aggregate, 100mm thick to fill the dismantled portion and making good as per existing after laying / passing the cables, etc complete all as specified & directed. |
| 16 | Fabricate,supply, install, connect, test and commission LT panel board out door type, made out of MS sheet 3.0 mm thick and angle iron frame of size 40x40x6 mm 3 phase, 4 wire, 415 Volts, AC, 50 HZ with TPN copper bus bar of capacity 400 A with PVC insulated heat shrink colour code sleeves, mounted horizontaly with porcelain insulators, sufficient air vent provision for all the three sides, stickers / plastic plates for switch gear details complete with voltmeter 0-500 volts Ammeter 0-200 Amps with CTS & selector switches, back to fuse, indicating lamps with toggle switches duly wired including, ELR with CBET locking arrngement & suitable foundation/ platform for mounting the panel with space for including switch gears.(a) MCCB TP 415 Volts 320 Amps 36 KA - 2 No (Incoming)(b) MCCB TPN 415 Volts 100 Amps 25 KA - 4 Nos (out going)(c) MCCB TPN 415 Volts 63 Amps 27 KA - 02 Nos (out going)(d) MCB TPN 415 Volts 40 Amps - 01 No (security light)(e) Provn of space for one feeder spareNote : 1. All out going/incoming cable connection marking including digging out loop deemed to be included in cost. 2. writing of feeder names with white paint in capital letters all as specified. Suitable size of glands & lugs to be provided for cable |
| 17 | Fabricate,supply, install, connect, test and commission LT feeder pillar box out door type, made out of MS sheet 3.0 mm thick and angle iron frame of size 40x40x6 mm 3 phase, 4 wire, 415 Volts, AC, 50 HZ with TPN copper bus bar of capacity 420 A with PVC insulated heat shrink colour code sleeves, mounted horizontaly with porcelain insulators, sufficient air vent provision for all the three sides, stickers / plastic plates for switch gear details complete including CBET locking arrngement & suitable foundation/ platform for mounting the panel with space for including switch gears. (a) MCCB FP 415 Volts 250 Amps 36 KA - 1 No (Incoming) (b) MCCB TP 415 Volts 200 Amps 36 KA - 1 No (out going)(c) MCCB TPN 415 Volts 100 Amps 25 KA - 3 Nos (out going)Note : 1. All out going/incoming cable connection marking including digging out loop deemed to be included in cost. 2. writing of feeder names with white paint in capital letters all as specified. Suitable size of glands & lugs to be provided for cable |
| 18 | Fabricate,supply, install, connect, test and commission LT feeder pillar box out door type, made out of MS sheet 3.0 mm thick and angle iron frame of size 40x40x6 mm 3 phase, 4 wire, 415 Volts, AC, 50 HZ with TPN copper bus bar of capacity 220 A with PVC insulated heat shrink colour code sleeves, mounted horizontaly with porcelain insulators, sufficient air vent provision for all the three sides, stickers / plastic plates for switch gear details complete including CBET locking arrngement & suitable foundation/ platform for mounting the panel with space for including switch gears. (a) MCCB TPN 415 Volts 200 Amps 25 KA - 1 No (In coming)(b) MCCB TP 415 Volts 160 Amps 36 KA - 1 No (out going)(b) MCCB TPN 415 Volts 100 Amps 25 KA - 3 Nos (out going)Note : 1. All out going/incoming cable connection marking including digging out loop deemed to be included in cost. 2. writing of feeder names with white paint in capital letters all as specified. Suitable size of glands & lugs to be provided for cable |
| 19 | S&F TPN copper bus bar of 300 A capacity for one incoming cable and 4 out going cable housing in sheet metal enclosure of MS sheet 3.0mm thick CRCA sheet steel and angle iron frame of size 40x40x6mm including locking arrangement & painting with two coats of powder coated paint over a coats of metal primer, suitable foundation & platform complete. |
| 20 | S&F TPN copper bus bar of 200A capacity for one incoming cable and 4 out going cable housing in sheet metal enclosure of MS sheet 3.0mm thick CRCA sheet steel and angle iron frame of size 40x40x6mm including locking arrangement & painting with two coats of powder coated paint over a coats of metal primer, suitable foundation & platform complete. |
| 21 | S&F Street light control panel confirming to IP 66 protection mounted on wall/pole/PCC foundation with suitable MS clamps & nut bolts etc installation and testing including 01 No MCB TPN 63 Amp (Incomer),01 No Contactor 63 Amp 3 Pole , 230V 3P module astronomical Time switch , bakelite fuse fitting with 2 A HRC fuse,indicaion lamp,mounting lugs,panel lock,hinged door,auto manual selector switch 6 Amp, detachable mounting DIN channel,supply monitoring device complete all as specified and directed |
| 22 | Supply and fix Thermoplastic cable junction box IP 66 halogen free and weather proof for out door installation( with metric knockouts and terminals for cable entry ) of size 205x255x112 mm Make : HENSEL Cat part no KF2525B or eqv make complete all as specified and directed. |
| 23 | M&L for PVC insulated 2 core 1100 volts grade 1.5 sqmm copper cable including necessary electric connection from junction box to security light fitting complete all as specified and as directed. |
| 24 | M&L for 20 mm dia PVC rigid conduit and necessary fixing arrangement on pole for protection of copper cable from junction box to fitting complete all as specified and as directed. |
| 25 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysSep 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer