Educational and Research Institute Boards / Undertakings / PSU Closing in 11 days TDR #57245802

Tender For Providing, Supply, Installation, Configuration, Testing And Commissioning For Establishment Of Centralized Fire Safety Control Room (Fire Command Centre/ Fire Control Room Response) Near 25 No. Admission Centre Behind Accidental &Emergency

Issued by Boards / Undertakings / PSU · Wardha, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Sep 2026
11 days left
EMD
59000
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Wardha → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing, Supply, Installation, Configuration, Testing And Commissioning For Establishment Of Centralized Fire Safety Control Room (Fire Command Centre/ Fire Control Room Response) Near 25 No. Admission Centre Behind Accidental &Emergency Icu At Kasturba Hospital, Sevagram.

BOQ

Name of Work:- Providing, Supply, Installation, Configuration, Testing and Commissioning for establishment of Centralized Fire Safety Control Room (Fire Command Centre/ Fire Control Room Response) near 25 no. admission centre behind Accidental &Emergency ICU at Kasturba Hospital, Sevagram.
Sl. No. Item Description
1Supply, installation, testing and commissioning of a microprocessor-based, 6 Loop Analogue addressable X-LINE loops, modular and networkable Fire Alarm Control Panel (FAP), Make: Schrack Seconet Integral EvoxX M , complete with operating/display panel, power supply, battery charger, standby batteries, loop modules, communication interfaces, necessary input/output modules and all accessories required for a complete working system., as specified and shown on drawings.The panel shall be suitable for large building/industrial fire detection installations and shall comply with the applicable requirements of EN 54-2 and EN 54-4 FAP Model :Integral EvoxX MFNumber of loops: 2 Nos. X-LINE addressable loopsLoop module: B8-DXI2Loop type: Two-wire addressable loopMaximum devices/loop: 250 devicesMaximum devices: 6 loops 3500 devices nominal maximumMaximum loop length: 3,500 m per loopDevice type Integral X-LINE compatible detectors/modules. Future expansion Panel shall be modular and capable of additional loop/module expansion
2Supply, installation, testing and commissioning of 6-loop Analogue addressable Fire Alarm Control Panel, Make:Schrack Seconet Integral EvoxX MF, complete with operating/display panel, power supply, battery charger, standby batteries, two-loop module, communication interfaces, input/output modules and all accessories required for a complete operational fire alarm system.The Integral EvoxX M is a modular, networkable fire alarm system with hardware and software redundancy and capability for expansion up to 16 loops. FAP Model : B-8-NET2-485Number of loops: 2 Nos. X-LINE addressable loopsLoop module: B8-DXI2Loop type: Two-wire addressable loopMaximum devices/loop: 250 devicesMaximum devices: 2 loops 500 devices nominal maximumMaximum loop length: 3,500 m per loopDevice type Integral X-LINE compatible detectors/modules. Future expansion Panel shall be modular and capable of additional loop/module expansion
3Supply, installation, testing and commissioning of 6-loop Analogue addressable Fire Alarm Control Panel, Make:Schrack Seconet Integral EvoxX MF, complete with operating/display panel, power supply, battery charger, standby batteries, two-loop module, communication interfaces, input/output modules and all accessories required for a complete operational fire alarm system.The Integral EvoxX M is a modular, networkable fire alarm system with hardware and software redundancy and capability for expansion up to 16 loops. FAP Model : B-8-NET2-FX4Number of loops: 2 Nos. X-LINE addressable loopsLoop module: B8-DXI2Loop type: Two-wire addressable loopMaximum devices/loop: 250 devicesMaximum devices: 2 loops 500 devices nominal maximumMaximum loop length: 3,500 m per loopDevice type Integral X-LINE compatible detectors/modules. Future expansion Panel shall be modular and capable of additional loop/module expansion
4Supply, installation, testing and commissioning of 2-loop Analogue addressable Fire Alarm Control Panel, Make:Schrack Seconet Integral EvoxX MF, complete with operating/display panel, power supply, battery charger, standby batteries, two-loop module, communication interfaces, input/output modules and all accessories required for a complete operational fire alarm system.The Integral EvoxX M is a modular, networkable fire alarm system with hardware and software redundancy and capability for expansion up to 16 loops. FAP type : B8-NET2-FX4Number of loops: 2 Nos. X-LINE addressable loopsLoop module: B8-DXI2Loop type: Two-wire addressable loopMaximum devices/loop: 250 devicesMaximum devices: 2 loops 500 devices nominal maximumMaximum loop length: 3,500 m per loopDevice type Integral X-LINE compatible detectors/modules. Future expansion Panel shall be modular and capable of additional loop/module expansion
5Supply, installation, testing and commissioning of 2-loop Analogue addressable Fire Alarm Control Panel, Make:Schrack Seconet Integral EvoxX MF, complete with operating/display panel, power supply, battery charger, standby batteries, two-loop module, communication interfaces, input/output modules and all accessories required for a complete operational fire alarm system.The Integral EvoxX M is a modular, networkable fire alarm system with hardware and software redundancy and capability for expansion up to 16 loops. FAP type :B8-NET2-485Number of loops: 2 Nos. X-LINE addressable loopsLoop module: B8-DXI2Loop type: Two-wire addressable loopMaximum devices/loop: 250 devicesMaximum devices: 2 loops 500 devices nominal maximumMaximum loop length: 3,500 m per loopDevice type Integral X-LINE compatible detectors/modules. Future expansion Panel shall be modular and capable of additional loop/module expansion
6Supply, installation, testing and commissioning of 2-loop Analogue addressable Fire Alarm Control Panel, Make:Schrack Seconet Integral EvoxX MF, complete with operating/display panel, power supply, battery charger, standby batteries, two-loop module, communication interfaces, input/output modules and all accessories required for a complete operational fire alarm system.The Integral EvoxX M is a modular, networkable fire alarm system with hardware and software redundancy and capability for expansion up to 16 loops. FAP type : B8-NET2-FX4Number of loops: 2 Nos. X-LINE addressable loopsLoop module: B8-DXI2Loop type: Two-wire addressable loopMaximum devices/loop: 250 devicesMaximum devices: 2 loops 500 devices nominal maximumMaximum loop length: 3,500 m per loopDevice type Integral X-LINE compatible detectors/modules. Future expansion Panel shall be modular and capable of additional loop/module expansion
7Supply, installation, testing and commissioning the BX-I2 is an addressable input module Make: Schrack Seconet Integral EvoxX / X-LINE system. It as having one monitored input for potential-free contacts and one optocoupler input for monitoring external voltages. Model: BX-I2Item No.: 20-2100016-01Type: X-LINE addressable input modulePrimary input : 1 × monitored input for potential-free contactsOptocoupler input: 1 × input for monitoring external/potential-bound voltageOperating voltage: 12–30 V DCTypical current consumption: 0.46 mASignal transmission X-LINE: serial two-wire technologyConnection Screw terminals: max. 1.5 mm²Short-circuit protection: Integrated short-circuit isolatorLine monitoring: Configurable monitored/non-monitored inputPrimary input: Can be configured/inverted and assigned as input or detector-zone functionOptocoupler input range: External voltage monitoring, up to approximately 0–30 V DCCable length: Up to 30 m for the input connectionTerminating resistors: 180 Ω resistors supplied for monitored inputEnclosure: Separate mounting case requiredProtection: IP66 with suitable caseAmbient temperature: −20 °C to +60 °CHumidity: 5–95% RH, non-condensingCertification VdS G212023; DoP CPR-20-13-01
8Supply, installation, testing and commissioning BX- O1 is the addressable output module with one potential-free bistable relay output. it in the EvoxX modular I/O range. Model: BX-O1Item No.: 20-2100015-01Type : X-LINE addressable output moduleOutput : 1 × potential-free, bistable relay outputRelay contact rating: 2 A maximumMaximum voltage: 230 V AC/DCMaximum switching load: 60 W maximumFail-safe function Programmable: fail-safe positionOperating voltage : 12–30 V DCTypical current consumption: 0.48 mACommunication :X-LINE, serial two-wire technologyShort-circuit: isolator IntegratedTerminals: Screw terminals, max. 1.5 mm²Protection: IP66 with suitable enclosureOperating temperature: −20 °C to +60 °CHumidity: 5–95% RH, non-condensingVdS approval: G212024DoP: CPR-20-13-013Module dimensions: 67 × 67 × 20 mm without enclosureEnclosure dimensions: 94 × 94 × 57 mm with enclosure
9Supply, installation, testing and commissioning the 2C X 1 sqmm RED FRLS Armored Cable Make :Epsilon
10Supply, installation, testing and commissioning the 2C X 1.5 sqmm RED FRLS Armored Cable Make :Epsilon
11Supply, installation, testing and commissioning of VPN LTE-LAN FAS Router Make:Schrack Seconet, Article No. 23-2010700-01, suitable for secure remote communication and service access to the Integral fire alarm control panel through the Schrack Seconet SecureOnlinePlatform (SOP).The router shall provide redundant communication via LTE mobile network and LAN/Internet connection and shall establish a secure encrypted VPN connection between the fire alarm system and the authorized remote service platform. Application: VPN connection for fire alarm control panelCommunication: LTE + LAN redundant connectionVPN: OpenVPN tunnelSecurity: Integrated firewall + encrypted VPN data transmissionNAT Integrated: Network Address TranslationEthernet: interfaces 1 × Ethernet, 10/100 Mbit/sSIM: slots 2 × SIM card slotsMobile: standards GPRS / EDGE / UMTS / LTEPower supply: 9–48 V DCMaximum power consumption: 5.5 WPower adapter: 230 V AC / 12 V DC supplied power unitInstallation: 35 mm DIN/top-hat railOperating temperature: −40 °C to +75 °CEnclosure Grey plastic:Dimensions H × W × D 52 × 116 × 99 mmAntenna : External LTE antennaConfiguration: Supplied pre-configured for remote access through SOPFirmware update LAN or automatic update functionWeb interface Integrated web interface for authorized configuration.
12Supply, installation, configuration, testing and commissioning of Schrack Seconet Integral Mobile software, comprising:Integral Mobile Basic 2 (IMOB BASIC 2)Integral Mobile Extension 2 (IMOB EXT 2)The combined configuration shall provide up to 4 simultaneous connections for authorized access to the Integral EvoxX fire alarm control system through Integral Mobile/Browser. Parameter IMOB BASIC 2 IMOB EXT 2Product Integral Mobile Basic 2 Integral Mobile Extension 2Type IMOB BASIC 2 IMOB EXT 2Article No. 23-2010903-01 23-2010904-01Simultaneous connections 2 2 additionalCombined capacity multicolumn=\\"2\\" 4 simultaneous connectionsApplication Integral Mobile Browser Extension of I Integral Mobile BasicCompatible system Integral EvoxX Integral EvoxX
13Provide, supply, install, configure, test and commission a Schrack Seconet VPN communication system for secure remote access and maintenance of the fire alarm control panel. The system shall include the approved Schrack Seconet VPN router, VPN credentials/certificate, required network connectivity, enclosure and associated accessories. The VPN connection shall permit authorized Schrack Seconet service personnel to remotely diagnose and maintain the fire alarm system. The VPN shall be configured and commissioned by Schrack Seconet or an authorized specialist. The VPN service shall not be considered an alarm transmission path unless separately certified and approved for that purpose. Item Schrack designation Article No.VPN router – LAN VPN LAN FAS 23-2010500-01VPN router – LTE/LAN VPN LTE-LAN FAS 23-2010700-01VPN certificate for PC VPN-Z-PC 23-2010800-01Router enclosure BMZ IP-BOX 23-2010010-015-port network B6-CTR 20-1400115-01
14Providing, supplying, installing, testing and commissioning addressable multi-sensor fire detector, Make: Schrack Seconet, Model: MTD 533X comprising combined optical smoke and thermistor/NTC heat sensing elements, suitable for detection of smouldering and open fires, programmable for smoke, heat or combined smoke/heat detection, with temperature-supported CUBUS signal evaluation, automatic contamination compensation, pre-alarm evaluation, adjustable alarm threshold, integrated short-circuit isolator and 360° visible red LED alarm indication. The detector shall be suitable for 2-wire addressable fire alarm loop operation, operating voltage 12–30 V DC, quiescent current approximately 120 µA, complying with EN 54-5, EN 54-7 and EN 54-29, with suitable detector base, IP44 protection with specified base, operating temperature -25°C to +60°C, complete with all accessories, mounting, testing and commissioning
15Providing, supplying, installing, testing and commissioning addressable manual call point, Make: Schrack Seconet, Model: MCP 545X, Type A manual call point conforming to EN 54-11, suitable for manual actuation of fire alarm, operating on 12.6–31 V DC, with built-in LED alarm indication, integrated short-circuit isolator and serial 2-wire communication compatible with the addressable fire alarm control panel/loop. The unit shall have screw-type terminals suitable for cable up to 2.5 mm² and shall be suitable for indoor surface/flush mounting or outdoor surface mounting as required. Outdoor version shall have minimum IP67 protection. The MCP shall be complete with mounting accessories, testing/reset facility, identification label, wiring, installation, testing and commissioning, complete in all respects.
16Providing, supplying, installing, testing and commissioning addressable combined fire alarm hooter-cum-flasher, Make: Schrack Seconet , suitable for integration with the existing Schrack Seconet Integral addressable fire alarm system, comprising electronic sounder and high-intensity LED visual alarm indicator, suitable for wall/ceiling mounting, with minimum 32 selectable alarm tones including DIN and Slow Whoop tones, sound output up to 97–98 dB(A) at 1 metre, selectable flash frequency of 0.5 Hz/1 Hz, adjustable sound volume, integrated short-circuit/open-circuit monitoring wherever applicable, and suitable for indoor/outdoor installation. The device shall comply with EN 54-3 for audible alarm and EN 54-23 for visual alarm indication, with IP65 protection for outdoor/wet locations, complete with compatible base, mounting accessories, connection, testing and commissioning, complete in all respects. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57245802
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 11-09-2026
Authority
Authority Name Mahatma Gandhi Institute Of Medical Sciences
Work Description Tender for Providing, Supply, Installation, Configuration, Testing And Commissioning For Establishment Of Centralized Fire Safety Control Room (Fire Command Centre/ Fire Control Room Response) Near 25 No. Admission Centre Behind Accidental &Emergency Icu At Kasturba Hospital, Sevagram.
Basic Detail
Tender No e-Tender/2026-27/EMD/05
Bidding Type Tender
Location
City Wardha
State Maharashtra
Key Dates
Publish Date 28 Aug 2026
Submission Date 11 Sep 2026
Open Date 14 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 1180
EMD 59000
Exemption Not Available
Document List
BOQ_FireCentre.xls
cc9b5389-0886-4247-9b62-d8c33c175237.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Sep 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_FireCentre.xls

html

cc9b5389-0886-4247-9b62-d8c33c175237.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders