Water Resources and Irrigation Government Departments Closing in 18 days TDR #57245612

Tender For Renovation Of Damaged Roof Sheet Over Conference Hall Passage And Parking Shed Of Rihand Hydro Power House, Pipri-Sonebhadra.

Issued by Government Departments · Sonbhadra, Uttar Pradesh
Tender Value
12.99 Lakhs
Estimated cost
Bid Submission
30 Sep 2026
18 days left
EMD
26000
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sonbhadra → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Renovation Of Damaged Roof Sheet Over Conference Hall Passage And Parking Shed Of Rihand Hydro Power House, Pipri-Sonebhadra.

BOQ

Name of Work:- Renovation of damaged roof sheet over conference hall passage and parking shed of Rihand Hydro Power House, Pipri-Sonebhadra.
Sl. No. Item Description
1Engagement of beldar/ coolie/ helper for non measured work such as site clearance, cleaning of roof terrace & sun shed, to assist the plumber, carpenter mistri & black smith, dismantling of damaged existing pvc roofing sheets, uprooting of vegetations from the outer wall and other miscellaneous work as per direction of Engineer-in-charge.
2Engagement of plumber for non measured work in repair and maintenance work of internal /external water supply pipe line as per direction of engineer-in-charge with all T&P required. (Labour rates only).
3Engagement of carpenter mistri for non-measured work in repair and maintenance of wood work as per direction of Engineer-in-charge with all T&P required. (Labour rates only.
4Engagement of black smith for non measured work such as repair and maintenance work of iron structures as per direction of engineer-in-charge with all T&P required. (Labour rates only).
5Fabrication & P/F of Tubular steel trusses duly painted with one coat of red oxide paint, designed & manufactured as per latest I.S.S. suitable for A.C. sheet or profile sheet roofing cover of the shed (Thickness of Tubes shall not be less than 3.25 mm) including cost of all materials, labour and T&P etc. required for proper completion of work & cartage upto site as per drawing including all accessories.
6Mild steel or iron work in heavy sizes such as built up gates, door, window & ventilator frames & grill, etc. wrought to required form including holes rivetting & welding where necessary and also fixing in proper position and alignment including cost of all materials supplied by contractor.
7Cement concrete with cement, coarse sand and 4 cm gauge stone ballast in proportion of 1:6:12 in foundations & under floors including supply of all materials, labour and T&P etc. required for proper completion of the work.
8Cement concrete with cement, coarse sand and 2 cm gauge approved hard stone ballast in proportion of 1:2:4 including supply of all materials, labour, side shuttering if required and T&P etc. required for proper completion of the work.
91st class brick work in 1:6 cement and coarse sand mortar in super structure for wall of one brick thickness including supply of all materials, labour and T&P etc. required for proper completion of work.
10RCC work with cement, approved coarse sand and 2 cm gauge graded approved hard stone ballast in proportion of 1:2:4 in slab, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials, binding wire, labour and T&P etc. required for proper completion of the work.
11TMT/Tor steel in plain work such as reinforced concrete work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel, its wastage, bend, hooks and authorized overlapping shall be measured. (Steel shall be arranged by the contractor).
1212 mm thick plaster with cement mortar in proportion of 1:4 cement and coarse sand over brick work, minimum thickness not to be less than 10 mm including supply of all materials, labour and T&P etc. required for proper completion of work.
13Repair to plaster in patches including removal of old plaster racking out joints to 1 cm depth, watering the area and then replastering with 1:4 cement mortar including supply of all materials, labour and T&P etc. required for completion of the work.
14P/L 8 mm thick glazed floor tiles of Somany, Johnson or equivalent make, laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry, jointing and polishing complete including supply of all materials, labour and T&P etc. required for proper completion of work.
15P/L 6 mm thick glazed tiles in skirting / dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry, jointing and polishing complete including supply of all materials, labour and T&P etc. completion required for proper completion of the work.
16P/F 15 mm Ø ISI UPVC/CPVC pipe (as per requirement) complete with special such as bend, tee, socket, cross, clamp, etc. Earth work including filling the trenches etc. required for proper completion of the work. The rate also includes concealed G.I. fitting where required, cutting and making good the walls etc. and all material labour T&P etc. complete (internal work).
17P/F Elliptical wash hand basin of white glazed earthenware first quality ISI marked (Hindustan / Cera make or equivalent brand) including supply of all materials, labour and T&P etc. complete.
18P/F Stainless Steel sink 610x450x200 mm heavy quality (ISI marked) including all materials, labour and T&P etc. required for proper completion of the work.
19P/F CP Brass Bib Cock 15 mm Ø ISI mark heavy quality (200 gm) (L&K or equi.) including supply of all materials, labour and T&P etc. required for proper completion of work.
20P/F 10 littres low level PVC flushing cistern, complete with all fittings including supply of all materials, labour and T&P etc. required for proper completion of the work.
21P/F precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, applying sealent at open joints/ overlapping but excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
22P/F precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling screws complete.
23Ridges plain (500 - 600 mm)
24Gutter (600 mm over all girth)
25Crimp curve
26P/F 24\\" (600 mm) dia. Aluminium S/S turbo ventilator heavy quality (ISI marked) on roof truss structure including fabrication and erection of supporting frame, cutting of roof sheet, weatherproof sealing, fastening arrangements, other required accessories as directed by Engineer-in-Charge and also including cost of all material, labour, T&P etc. required for proper completion of the work.
27Scraping existing plaster surface / old tarfelt from roof including disposal of refuse as directed by the Engineer-I/C within a distance of 60 meters.
28P/L APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc. and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under: Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of manufacturer of membrane.
29Hire charges of single phase portable welding set including cost of electrode along with the driver.
30P/F false ceiling with 8 mm thick calcium silicate board of size 595x595 mm in true horizontal level suspended on interlocking metal grid at all height including providing and making frame work including all items having NRC (Noise Reduction coefficient) of 0.50 (minimum), Light reflectance 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile, rotary stiched double webbed white. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm c/c and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
31Painting new iron or wood work with one coat of ready mixed priming paint/wood primer and one coat of approved superior quality ready mix paint including supply of all materials, labour and T&P etc. required for proper completion of the work.
32Same as in above item but for the second coat after the first coat.
33Applying Birla or equivalent putty on new interior or exterior surface over one coat of water based cement primer of ICI or equivalent brand for smoothening and levelling of the surface as per requirement and direction of Engineer I/C including cost of all material, labour, T&P etc. required for proper completion of the work.
34Painting first coat with Acrylic emulsion paint of Berger/ Asian/ ICI or equivalent paint (Paint and water in the ratio 1:1 by volume) over prepared and primed surface of cement concrete, cement plaster and bricks of required shade including all labour, material and T&P etc required for proper completion of the work (preparation of base with birla putty etc. and a coating of primer shall be paid extra).
35Same as above item but for the 2nd coat after the first coat.
36Painting first coat with Acrylic emulsion paint of Berger/ Asian/ ICI or equivalent paint (Paint and water in the ratio 1:1 by volume) on previously painted surface of cement concrete, cement plaster and bricks of required shade including all labour, material and T&P etc required for proper completion of the work.
37Same as above item but for the 2nd coat after the first coat.
38Painting 1st coat with APEX or equivalent brand weather coat paint on new wall surfaces (well prepared with Birla putty and one coat of primer ICI or equivalent which shall be paid separately) including through washing with water including cost of all materials, labour, T&P required for proper completion of work.
39Same as above item but for the 2nd coat after the first coat.
40P/F informatory PVC self adhesive signage of desired size as per site requirement as visual communication tool to guide visitors/ officials and to enhance navigation including cost of all materials, labour and T&P etc. required for proper completion of the work.
41P/F premium quality (ISI marked) decorative W.P.C. (Wood Plastic Composite) wall panels of size 160 mm × 24 mm (or equivalent) of required shade including necessary aluminium/ PVC framework, adhesive, screws, edge trims and also including all materials, labour and T&P etc. required for proper completion of the work as directed by Engineer-in-Charge.
42P/F fully Anodized aluminium openable glazing window portion with HINDALCO or equivalent extruded standard sections14 gauge (2.41mm thick) of various cross sections and joints mitred and jointed including providing & fixing 5.5 mm thick toughened glass with Neoprene beading & aluminium glazing clips all around and including cost of Aluminium hinges and all other fittings like concealed tower bolts handles etc of approved quality. The minimum thickness of anodizing on all aluminium sections should be 20 microns with a (+) 2 microns tolerance. The rate should include the cost of fixing the aluminum frame on finished wall (RCC/Masonry) surface by means of 80 mm long approved counter sunk screws provided at 500 mm c/c or part there of starting from 100 mm above the bottom in vertical member and 100 mm from both the ends of horizontal top and bottom member including cost of all other materials, labour, T&P, etc. required for proper completion of the work.
43P/F glazing with float glass panes of 4.0 mm thickness in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge and also including cost of aluminium snap beading, all materials, labour and T&P etc. required for proper completion of the work.
44P/F glazing with float glass panes of 5.5 mm thickness in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge and also including cost of aluminium snap beading, all materials, labour and T&P etc. required for proper completion of the work.
45P/F 4.0 mm thickness ACP in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge and also including cost of aluminium snap beading, all materials, labour and T&P etc. required for proper completion of the work.
46S/F of Galvenized Mosquitos proof heavy quality iron wire gauge (14x24) over window frames and including supply of Country wood battens 8cmx1cm and including supply and fixing of necessary screws, all materials, labour and T&P etc. required for proper completion of the work.
47P/F 25 mm Ø chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc. wherever necessary complete.
48S/F brass polished hydraulic door closure of approved make & quality its fixing and adjustment with the help of screws, nuts and bolts including supply of all labour, T&P etc. required for proper completion of the work.
49Providing 12 mm thickness ply (Waterproof hot pressed) (Century / Green or equivalent brand).
50P/F of 110 mm Ø PVC pipe (4 kg./sq.cm) for rain water down pipe with specials such as tee, bend, socket, elbow, binding clip, etc. including cutting of pipe wherever necessary and including all materials, labour and T&P etc. required for proper completion of the work.
51Engagement of Electrician Grade-II for non measured work such as internal and external wiring work, making light connection, installation of lights, various electrical works including installation, maintenance, repair, testing, wiring and other miscellaneous electrical works as per direction of Engineer-in-charge.
52Providing wiring point for light with 1.5 sq.mm PVC insulated copper single core cable with casing-capping wiring on surface and 5A piano type switch including supply of all materials, labour and T&P required for proper completion of the work.
53Providing wiring point for fan with 1.5 sq.mm PVC insulated copper single core cable with casing-capping wiring on surface and 5A piano type switch including supply of all materials, labour and T&P required for proper completion of the work.
54Providing wiring point for 5A-3 pin socket with 1.5 sq.mm PVC insulated copper single core cable and 5A piano type switch including supply of all materials, labour and T&P required for proper completion of the work.
55Providing wiring point for power point with 2.5 sq.mm PVC insulated copper single core cable with casing-capping wiring on surface excluding switch & socket and including supply of all materials, labour and T&P required for proper completion of the work.
56P/F of sub-mains on 10\\"x12\\" teak wood board consisting of 04 nos. 16A kit-kat fuse and 01 no. indicator on it including supply of all materials, labour and T&P required for proper completion of the work.
57P/F of modern modular design electrical switch and socket PVC board of size upto 8\\"x10\\" after fixing existing point including supply of all materials, labour and T&P required for proper completion of the work.
58P/F of power socket with 15A & 240 V switch including supply of all materials, labour and T&P required for proper completion of the work.
59P/F of single pole 32A MCB including supply of all materials, labour and T&P required for proper completion of the work.
60P/F of 2 Ton Split AC 5 star (Hitachi, Daikin, Voltas or equivalent make) along with 5 KVA V-Guard or equivalent make stabilizers, stands, drain pipes etc. including installation, required length of cables, labour, T&P and all related works as required for proper installation & running of the system complete in all respects as approved by Engineer-in-Charge.
61P/F of 3 blade wall fan of Havells platina 400 mm or equivalent make including all material, T&P etc. required for proper completion of the work as approved by engineer-in-charge.
62P/F 2x2 feet 36 watt LED Light panel for false ceiling having Bajaj, Havells, Crompton or equivalent make.
63P/F monogram of size upto 2'x2' or 2' dia. showing department details with lighting & neon glowing effect.
64P/F LED profile strip light for decoration & neon glowing effect of desired colour as per site requirement with
65P/F photo frames of size upto 30\\"x24\\" to present the remarkable visual journey of project at required location as per site requirement with complete fittings.
66P/F LED indoor decorative wall/ ceiling ligh/ photo frames with luxurious finish upto 07 watt of desired colour as per site requirement with complete fittings. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57245612
AUTHORITY Government Departments
TENDER VALUE 12.99 Lakhs
LAST DATE 30-09-2026
Authority
Authority Name Uttar Pradesh Jal Vidyut Nigam Limited
Work Description Tender for Renovation Of Damaged Roof Sheet Over Conference Hall Passage And Parking Shed Of Rihand Hydro Power House, Pipri-Sonebhadra.
Basic Detail
Tender No E-Tender Notice No. 01/RCCMD/2026-27
Bidding Type Tender
Location
City Sonbhadra
State Uttar Pradesh
Key Dates
Publish Date 29 Aug 2026
Submission Date 30 Sep 2026
Open Date 01 Oct 2026
Finance
Tender Value 12.99 Lakhs
Tender Fee 1180
EMD 26000
Exemption Available
Document List
2079c64f-13a4-4aaf-8524-e124903b710b.html
BOQ_2219798.xls
Tendernotice_1 (66).pdf
Tendernotice_2 (15).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Oct 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

2079c64f-13a4-4aaf-8524-e124903b710b.html

xls

BOQ_2219798.xls

pdf

Tendernotice_1 (66).pdf

pdf

Tendernotice_2 (15).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders