Rural Development Local Bodies Closing in 11 days TDR #57244712

Tender For Supply& Installation Of Led Street & Flood Light (45W,72W,90W,100W & 120W) At 436,432,426,418 Nanda Ghosh Road, Pilkhana 3Rd Lane & Different Areas In Pilkhana Under Ward No-16 Of Hmc.

Issued by Local Bodies · Howrah, West Bengal
Tender Value
5.30 Lakhs
Estimated cost
Bid Submission
18 Sep 2026
11 days left
EMD
10602
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Howrah → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply& Installation Of Led Street & Flood Light (45W,72W,90W,100W & 120W) At 436,432,426,418 Nanda Ghosh Road, Pilkhana 3Rd Lane & Different Areas In Pilkhana Under Ward No-16 Of Hmc.

BOQ

Name of Work:- Supply& Installation of LED Street & Flood Light (45W,72W,90W,100W & 120W) at 436,432,426,418 Nanda ghosh Road, Pilkhana 3rd lane & different areas in Pilkhana under ward no-16 of HMC.
Sl. No. Item Description
1Erection of single steel Tubular pole of length as given below with /without sole plate & cap etc. in C.C. foundation (Proportion and dimension indicated below). having 600 x 600 x 150 mm. thick C.C. (4:2:1) base block below sole plate/pole with hard jhama metal incl. C.C (6:3:1) muffing 0.30 Mt.dia and 0.30 Mt above ground level incl.3mm thick neat cemented finished and G.I. earth bolt after making drilled holes etc.on pole & Carriage of pole upto 1.6 Km from store to work site incl. filling up the excavated earth pit with shifted soil and ramming properly. Pole upto 9 Mts. Size- 0.6 x 0.6 x 1.70 Mts. Ref: PWD/Elec.works/2017/P-H-1/I-1
2Distribution wiring for street light on pole for outdoor fluorescent / SV / MV light fitting with 2 x 1 / 1.40 PVC insulated and sheathed wire (single core) in 15 mm dia GI pipe (ISI-Medium) without control switch, incl. fitting and fixing the light fitting by providing 32 mm dia GI pipe bracket of length 1.05 mts., on pole incl. S&F suitable MS flat clamps with bolts, nuts etc. as required and painting. Ref: PWD/Elec.works/2017/P-H-5/I-H(2)
3Supplying & fixing GI waterproof type looping cable box size 200 x 150 x 100mm deep having 4mm thick comprising of one 250Volts 15 A Kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2 core 16 sqmm PVC/A cable and having lined with rubber gasketted CI top cover with brass machine screws etc. earthing terminal with lug,on steel tubular pole near base, incl. S & F 40 x 6 mm thick, MS clamps with bolts, nuts etc.incl.painting with anticorrosive paint. Ref: PWD/Elec.works/2017/P-H-5/I-H(5)
4Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (hot Dip) wire (4 Mts.long), 13 mm dia x 80 mm long GI bolts, double nuts,double washers incl. S&F 15 mm dia GI pipe protection (1 Mt.long)to be filled with bitumen partly under the ground level and partly above groung level driven to an average depth of 3.65 Mts.below the ground level. By ISI-Medium G.I Pipe. Ref: PWD Elec Works 2017
5Supplying & Erection of 75 x 88 mm Porcelain Shackle insulator complete with 190 x 30 x 5 mm Galv.(Hot Dip) Strips with 15.88mm dia Galv. bolts, nuts, etc. for conductor upto 7/3.10 mm, 32 sqmm of AAC/equivalent size of ACSR. Ref: PWD/Elec.works/2017/P-H-3/I-D(1)
6Supply of Al.Conductor PVC insulated and sheathed unarmoured cable (1.1 KV grade, Gloster/Havells/Polycab). 4 Core x 10 mm.2. Ref: UDMA/Elec.-Mech.works/2018/P-13/I-3©
7Supply and drawing of 7/14 SWG galvanised stranded wire for drawing unarmored cable (supply of cable is not included in the scope) by catenary system of wiring with 3nos. reel insulator per mtr. and binding with binding wires etc,as reqd. for drawing & Drawing of unarmoured cable of suitable size (supply of cable is not included in the scope)on existing Galvanized stranded wire for centenary system with reel insulators and binding wires. Ref: UDMA/Elec.-Mech.works/2018/P-8/I-41&42
8Laying of one No.cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 Nos.bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, levelling up and restoring surface duly rammed. Ref: PWD/Elec.works/2017/P-F-2/I-1(a)
9Supply of 1.1 KV grade PVC insulated unarmoured cable with Al.Conductor as per IS-7098 31/2 x 25 mm2 Ref: Ref: UD & MA Price List Schedule 2018
10Supplying of 7 Mtr S.T Pole Ref: ud & Ma Electrical works 2018
11Supplying of 45W LED Street Lighting Luminaries with pressure die cast al housing,IP66 protection Ref: CPWD Price list schedule wef 08,2025-P-NO-51-I-8.13.11
12Supplying of 72W LED Street Lighting Luminaries with pressure die cast al housing,IP66 protection Ref: CPWD Price list schedule wef 08,2025-P-NO-51-I-8.13.13
13Supplying of 90W LED Street Lighting Luminaries with pressure die cast al housing,IP66 protection Ref: CPWD Price list schedule wef 08,2025-P-NO-51-I-8.13.14
14Supplying of 120W LED Street Lighting Luminaries with pressure die cast al housing,IP66 protection Ref: CPWD Price list schedule wef 08,2025-P-NO-51-I-8.14.16
15Supplying of 100W LED Street Lighting Luminaries with pressure die cast al housing,IP66 protection Ref: CPWD Price list schedule wef 08,2025-P-NO-51-I-8.15.3
16Supply & Erection of Medium Size feeder pillar box of size (1200x750x450mm) made up of 2 mm thick MS Plate along with suitable M.S Angle. The P.B hinage door at the front & back with suitable locking arrangement. The box will be painted by 2 coat Al paint over 1 Coat of RO paint. Suitable arrangement should be provided for fixing of Timer unit, fuse unit & other accessories. Leg of the Pillar box will be 900mm in length by made up of (35x35x3mm MS Angle with suitable base plate, Legs of the Pillar box will be erected at 300mm below the ground level with cement concrete (6:3:1). Rest portion coverd by 5\\" brick wall with plastering & net cement & bottom portion filled with silver sand. Ref: Ud & Ma electrical Works 2018
17Suuply & fixing of Power contactor 40A ML3. Ref: Ud & Ma Elec Works 2018/p.no-19-I-18(F)
18S&F of Time switch for auto-switch on & off during evening and morning respectively Type: FM1/ digi20 plus, 240 v AC Flus Mounting. Ref: Ud & Ma Elec Works 2018/p.no-19-I-31(B)
19Supply of 415V, 63A TPN MCB with breaking capacity of 10 KA Ref: PWD Elec Works/D7-I-8(Make: Havells or equivalent)
20GST 18%
21LWC 1%
22Electrical Service connection charges from C.E.S.C Ltd/W.B.S.E.D.C. Ltd. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57244712
AUTHORITY Local Bodies
TENDER VALUE 5.30 Lakhs
LAST DATE 18-09-2026
Authority
Authority Name Urban Local Bodies
Work Description Tender for Supply& Installation Of Led Street & Flood Light (45W,72W,90W,100W & 120W) At 436,432,426,418 Nanda Ghosh Road, Pilkhana 3Rd Lane & Different Areas In Pilkhana Under Ward No-16 Of Hmc.
Basic Detail
Tender No WB-HMC/NIT/ED-010/L/2026-27
Bidding Type Tender
Location
City Howrah
State West Bengal
Key Dates
Publish Date 27 Aug 2026
Submission Date 18 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value 5.30 Lakhs
Tender Fee 2000
EMD 10602
Exemption Not Available
Document List
51227615-7c07-4209-95fc-a9ee265a376f.html
BOQ_2552926.xls
Tendernotice_1 (32).pdf
Tendernotice_2 (3).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

51227615-7c07-4209-95fc-a9ee265a376f.html

xls

BOQ_2552926.xls

pdf

Tendernotice_1 (32).pdf

pdf

Tendernotice_2 (3).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders