Tender For Maintenance Of Electrical Installations, Chainlink Fence Around Installations, Repair Of Cable Dust And Plinths, Hard Standings And Pathway Including Vegetation Clearance And Other Misc Works At E/M Installation Under Ge Golconda.
Tender Overview
Project Description
Tender for Maintenance Of Electrical Installations, Chainlink Fence Around Installations, Repair Of Cable Dust And Plinths, Hard Standings And Pathway Including Vegetation Clearance And Other Misc Works At E/M Installation Under Ge Golconda.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Sep-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) File No 8162/E8 Tender Inviting Authority: GARRISON ENGINEER GOLCONDA Name of Work: MAINTENANCE OF ELECTRICAL INSTALLATIONS, CHAINLINK FENCE AROUND INSTALLATIONS, REPAIR OF CABLE DUST AND PLINTHS, HARD STANDINGS AND PATHWAY INCLUDING VEGETATION CLEARANCE AND OTHER MISC WORKS AT E/M INSTALLATION UNDER GE GOLCONDA. Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder including all TaxesRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc. Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in soft/loose soil complete all as specified and as directed. |
| 3 | Excavation in trenches exc 1.5 mtr wide and exc 1.5 mtr depth for pole / cable / foundation etc including getting out in soft /loose soil complete all as specified and directed. |
| 4 | Returning and filling in of excavated soil including spreading,levelling,watering and well ramming in layers not exceeding 25 cm each complete all as specified and as directed.. |
| 5 | Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed. |
| 6 | M&L for Sand cushioning/sand covering for underground cable protection complete all as specified and as directed.Note: Punned thickness only will be measured and paid. |
| 7 | Supply and laying sub class 'B' bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed. |
| 8 | M&L Plain Cement Concrete (PCC) of nominal mix 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate of D2 with 40 mm nominal size) as levelling course below fence/gate post foundations, including mixing, placing, compacting, curing and finishing including Dismantling the foundation & coping of poles complete all as specified and as directed.. |
| 9 | Providing and laying Cement Concrete of nominal mix 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate of 20 mm nominal size) for embedding and fixing fence/gate posts, including mixing, placing, vibrating, compacting, finishing, curing and all incidental works complete all as specified and as directed. |
| 10 | Material and Labour Pre-cast cement concrete block masonry type C1 1:3:6 using 20mm stone aggregate with solid blocks, exc 10 cm in width and setting mortar 1:6 complete all as specified and as directed. |
| 11 | Material and Labour Rendering 15 mm thick on exposed brick masonry/block masonry/RCC surfaces of transformer foundation and plinth, including preparation of surface, raking out joints where required, cleaning, wetting, applying plaster to true line, level and plumb, finishing smooth and even without extra cement punning, curing complete all as specified and as directed. |
| 12 | M&L for PCC 1:3:6 type C2 using 40 mm graded aggregate for coping of poles/Post and stay including form work and Dismantling the foundation & coping of poles/posts complete all as specified and as directed. |
| 13 | S&F of MS steel angle iron work as in struts and posts in fencing including cutting tops to shape as directed ,drilling holes notching for wire any flat iron fillets (for securing wire mesh and any wire type) including drilling, bolting or riveting and embedding in angle iron and screwing etc similar work confirming to Fe 410-0 or Fe 310-0 complete all as specified and as directed. |
| 14 | Dismantling of existing damaged fencing and supply & fixing MS galvanized PVC-coated chain link fencing with PVC coating , fabricated from 4 mm diameter wire with 50 mm × 50 mm mesh spacing, complete with all necessary accessories including line wires, hard rails, straining bolts, tension bands, binding wire, clamps, cleats, nuts, bolts, washers, tie wires, and other fixing accessories required for proper installation. The fencing shall be diagonally pinned wherever specified and securely fixed to MS posts/rails by bolting or tying as required. All drilling, cutting, fitting, tightening, and erection work shall be carried out complete in all respects, as specified and as directed. |
| 15 | Dismantling of existing damaged Post, and supply & fixing Hot-Dip Galvanized Steel Square Hollow Section (SHS) fence posts of size 60 × 60 × 3 mm, having an overall length of 2700 mm (including the embedded portion), suitable for supporting 2100 mm high welded wire mesh fencing. The post shall be fabricated from structural steel SHS complete with welded top cap, galvanized fixing clamps/brackets for mesh panels, galvanized bolts, nuts and washers, and all accessories required for complete installation. The post shall be hot-dip galvanized after fabrication in accordance with relevant standards complete all as specified and as directed. |
| 16 | Dismantling of existing damaged Double-Leaf Mild Steel (MS) Entrance Gate and supply and fix 2000 mm clear opening × 2100 mm height, fabricated from 100 × 100 × 4 mm SHS gate posts and 60 × 60 × 3 mm SHS outer frame with 40 × 40 × 3 mm SHS intermediate members. The gate shall be infilled with welded wire mesh of 50 × 100 mm aperture made from 5 mm diameter GI wire, securely fixed to the gate frame. The complete gate assembly, including posts, frame, brackets and fittings, shall be hot-dip galvanized after fabrication. The gate shall be provided with heavy-duty adjustable hinges, central locking arrangement, sliding tower bolts/drop bolts, stopper, locking plate, hold-fast arrangements, galvanized bolts, nuts, washers and all accessories required for complete installation complete all as per Directed. |
| 17 | Supply and spread stone metal graded aggregate of size 40 mm at transformer yard complete all as specified and as directed. |
| 18 | Clearing of bushes/small plants upto root level around and surroundings areas E/M installations (i.e. Two Pole/ Four structures, outdoor-substation yards, pump house & STP installations etc) including surface dressing n.exc 15 cm deep and removing debris to a distance n.exc 50m complete all as specified and as directed. |
| 19 | Supply, fabricate and fix cross arms any size along with, brackets, clamps, bolts, nuts, washers, bracers etc including drilling holes, cold/hot complete and fixed to pole including one primer coat and one under and finishing coat of paint complete all as specified and as directed. |
| 20 | S&F danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts, nuts of approved size for HT 25x20 cm size including dismantling old one complete all as specified and as directed. |
| 21 | S&F danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts, nuts of approved size for LT 20x15 cm size including dismantling old one. |
| 22 | Dismantling air break gang operated switches triple pole vertical/ horizontal mounted including insulators and operating mechanism for replacement all as directed. |
| 23 | S&F GOD switches air break gang operated, triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level, for current rating up to 400 Amps complete all as specified and as directed. |
| 24 | Taking down old DO fuse unit S &F expulsion fuse single phase above 50 & up to 100 AMPS capacity, 11000 Volts complete all as specified and as directed. |
| 25 | Taking down existing unserviceable Lightning arrestor and S&F lightning arresters expulsion type complete with all fittings transmission class, discharge capacity 10 KA suitable for 11000 Volts line complete all as specified and as directed. |
| 26 | M&L for replacement of galvanised iron strip 32x6 mm buried in ground or fixed on pole with all accessories including dismantling old one complete all as specified and as directed. |
| 27 | Earthing complete with Galvanised Steel earth plate of size 60x60cmx6.3mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.5 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion complete all as specified and as directed. (Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing). |
| 28 | M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 120 to 185 Sqmm including testing after jointing complete all as specified and as directed |
| 29 | M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 50 to 95 Sqmm including testing after jointing complete all as specified and as directed |
| 30 | Supply, installation, testing and commissioning of 6 m high Steel pole solar LED street light complete with 45 W LED luminaire, 150 Wp solar PV module, 12.8 V 42 Ah LiFePO₄ battery, MPPT charge controller, cabling, earthing, clamps, hardware and all other accessories required for proper operation, complete in all respects as per approved specifications and directions of the Engineer-in-Charge complete all as specified and as directed |
| 31 | Supply, erecting and fixing in repair true vertical position, steel tubular swaged pole 410 SP-55 (11.0 metres long) , complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint and including making alternate white and black strips 30 cms height (05 Nos strips) numbering the poles by 2\\" height 06 Nos letters complete all the metallic surfaces complete all as specified and as directed. |
| 32 | M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 25 to 50 sq.mm complete all as specified and as directed. |
| 33 | All as per Item No.31 herein before but for cable of size 3.5 core 70 to 150 sq.mm complete all as specified and as directed. |
| 34 | All as per Item No. 31 herein before but for cable of size 3.5 core 185 to 400 sq.mm complete all as specified and as directed. |
| 35 | M&L for heat shrinkable end termination joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 16 to 50 sq.mm complete all as specified and as directed. |
| 36 | Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade XLPE insulated , armoured, electric power cables (heavy duty) with aluminium conductor of the following size including dismantling old one. Note: The rate quoted inclusive of termination at ends with suitable aluminium lugs ,Crimping ,Glanding wherever required complete all as specified and as directed. Make: Paragon/Havells/Polycab/ Nicco or techno commercially equivalent make as listed in list of makes as approved by GE.16 Sqmm 4 core |
| 37 | All as per item no. 35 above but 25 Sqmm 4 core |
| 38 | All as per item no. 35 above but 3.5 core 35 Sqmm |
| 39 | All as per item no. 35 above but 3.5 core 50 Sqmm |
| 40 | All as per item no. 35 above but 3.5 core 70 Sqmm |
| 41 | All as per item no. 35 above but 3.5 core 95 Sqmm |
| 42 | All as per item no. 35 above but 3.5 core 120 Sqmm |
| 43 | All as per item no. 35 above but 3.5 core 150 Sqmm |
| 44 | All as per item no. 35 above but 3.5 core 185 Sqmm |
| 45 | Design, Fabrication, supply, installation, commissioning and testing Double Door Panel board manufactured from CPRI approved firm with canopy head, out door, cubical type panel board of over all min dimension 1800 mm (H) × 1200 mm (W) × 450 mm (D) fabricated with 3.0mm thick CRCA sheet on mild steel angle iron 50X50X6 mm thick frame, totally enclosed type dust & vermin proof back side open-able fixed with hinged shutter and front side open-able with hinged shutter and locking arrangement for individual MCCBs/MCBs , powder coated finished both internally and externally suitable for 415Volt AC 50 Hz 3 Phase 4 wire system by means of Aluminium bus bar of 800 Amps Capacity (Main bus bar ) and 600 Amps Loop Bus bar with coloured insulating tape/sleeves mounted on porcelain or synthetic insulators with provision for fixing MCCBs/MCBs necessary inter connections with Aluminium bar/strip duly coloured code insulation and providing under mentioned equipments & accessories including connections of all out going/in coming existing/New cables of required size and including PCC foundation in 1:3:6, type C1 of 0.5 mtrs height above GL and 0.30mtrs below GL including necessary earth work complete all as specified and as directed. (a) INCOMING: MCCB 4 pole 400Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals - 01No Make: L&T/Legrand/ ABB/Siemens/Havell OUTGOING: (a) MCCB 4 pole 250Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals -01 Nos (b) MCCB 4 pole 160 Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals -02 Nos (c) MCCB 4 pole 100 Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals -02 Nos(d) O/G MCB TPN 63Amp, 10KA,C curve - 02 Nos (d) Indicating lamp LED type 240V 50 Hz AC -one set of 3 . |
| 46 | Supply & fixing in repairs of MCCBs of following current carrying capacity including necessary connecting terminals to bus bar, nut bolts etc. complete all as specified and as directed. Make: C&S/Schneider/L&T/Hager/Havells or techno commercially equivalent make as listed in list of makes as approved by GE.125 Amps, 3P,Adjustable type, 415 V MCCB, 16KA rating |
| 47 | All as per item no. 45 above but 100 Amps, 3P, 415 V MCCB, 16KA rating |
| 48 | All as per item no. 45 above but 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 36 KA, 400 A rated |
| 49 | All as per item no. 45 above but 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 36 KA, 250 A rated |
| 50 | All as per item no. 45 above but 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 26 KA, 200 A rated |
| 51 | All as per item no. 45 above but 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 26 KA, 160 A rated |
| 52 | Providing, supplying, fixing, testing and commissioning of fire safety equipment for distribution substation, including 6 kg ABC type Dry Chemical Powder (DCP) fire extinguishers, 9 litre Foam (AFFF) type fire extinguishers, 2 kg CO₂ fire extinguishers, fire buckets with stand (ISI marked) including sand filling, fire safety signage boards (reflective/glow type as per IS/NBC standards), and MS powder coated fire extinguisher stands/cabinets, complete in all respects including mounting, installation, initial charge, accessories, labour, transportation, testing and commissioning as per approved drawings and statutory requirements complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender