Tender For Repair/ Maint, Load Testing / Servicing Of Electrically Operated Crane At Af Stn Tughlakabad
Tender Overview
Project Description
Tender for Repair/ Maint, Load Testing / Servicing Of Electrically Operated Crane At Af Stn Tughlakabad
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 26-Sep-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Material and Labour for painting to EOT crane in any various capacity installed at various PWs and with super enemelled paint of approved manufacturing colour on exposed surface including preperation of surfaces and appying two coats of zinc cromate primer followed by two coats of golden yellow ISI marked synthetic enemel paint by mechanical means only complete all as specified and directed. Note: After painting write the SM/ MES No and crane name /No as per existing size |
| 2 | Material and Labour for replacement of heavy duty thruster brake suitable for 1/2 Ton/1Ton EOT crane complete all as per site requirement complete all as specified and as directed. Make: Compatible with OEM. |
| 3 | Material and Labour for replacement of heavy duty thruster brake suitable for 3 Ton EOT crane complete all as per site requirement complete all as specified and as directed. Make: Compatible with OEM. |
| 4 | Material and Labour for Replacement of heavy duty thruster brake suitable for 7.5 to 10 Ton EOT Crane complete all as per site requirement complete all as specified and as directed. Make: Compatible with OEM. |
| 5 | Material and Labour in replacement of step down transformer 300 VA/415/110/24 volt suitable for 1/2 Ton/1Ton EOT crane complete all as specified and as directed. Make: Compatible with OEM. |
| 6 | Material and Labour in replacement of step down transformer 300 VA/415/110/24 volt suitable for 3 to 5 ton EOT crane complete all as specified and as directed. Make: Compatible with OEM. |
| 7 | Material and Labour in replacement of step down transformer 300 VA/415/110/24 volt suitable for 7.5 to 10 ton EOT crane complete all as specified and as directed. Make: Compatible with OEM. |
| 8 | Supply and Fix in replacement of galvanized steel wire rope of nominal dia 12mm having maximum Tensile strength of 1960 N/mm2 for EOT crane 10 ton as per existing make and type heavy duty complete all as specified and directed. |
| 9 | Supply and Fix in replacement of galvanized steel wire rope of nominal dia 10mm having maximum Tensile strength of 1960 N/mm2 for EOT crane 2/3/5 ton as per existing make and type heavy duty complete all as specified and directed. . |
| 10 | Supply and Fix in replacement of galvanized steel wire rope of nominal dia 08mm having maximum Tensile strength of 1960 N/mm2 for EOT crane 1.25, 1.00 & 0.5 ton as per existing make and type heavy duty complete all as specified and directed. |
| 11 | Material and Labour for crane load testing of 0.5 ton EOT crane at 110% of the safe working load by providing dead load/load test block for capacity test on all the motions of cranes (dead weight load to be arranged by the Contractor). Note:(a) Record of load test kept in record duly signed by user’s rep / MES rep and no extra payment shall be made on this account. A load testing certificate furnished by OEM shall be submitted by the contractor after load tetsing for every individual crane. (b) Contractor will ensure all the cranes are in serviceable condition before starting the load testing. If any crane are in unserviceable condition the same will be made serviceable before starting the load testing. (c) Contractor will provide safty pecaution on requirement basis. |
| 12 | All as per item No 11.00 herein before but for capacity 1 ton |
| 13 | All as per item No 11.00 herein before but for capacity 3 ton |
| 14 | All as per item No 11.00 herein before but for capacity 5 ton |
| 15 | All as per item No 11.00 herein before but for capacity 10 ton |
| 16 | Supplyand Fix in replacement of copper conductor multistranded standard FRLS PVC insulated 16 Sqmm (3) three core complete all as specified and directed. |
| 17 | Material and Labour for Servicing of 10 ton EOT crane comprising of the following:-(a) Greasing/oiling of required part shaft, coupling, rope drum shaft bearing etc.(b) Checking & testing/adjustment of brakes for all the motions(c') Checking & tightening of coupling bolts, motor foundation bolt etc.(d) Checking the wiring connections in control panel and other accessories and to ensure that no loose/naked connection exist.(e) Checking of gear oil in gear boxes and topping up them if necessary .(f) Checking of transformer oil in electro hydraulic thruster unit & topping if necessary. (g) Cleaning of Bridge girder including plate form, cabin, panel, complete |
| 18 | All as per item No 17.00 herein before but for crane 5 ton EOT crane. |
| 19 | All as per item No 17.00 herein before but for crane 3 ton EOT crane. |
| 20 | All as per item No 17.00 herein before but for crane 1.25 ton & 1 ton EOT crane. |
| 21 | All as per item No 17.00 herein before but for crane ½ ton EOT crane. |
| 22 | Material and Labour in replacement of cable resting trolly MS Wheel (with four ball bearing) for 5 Ton EOT crane including necessary welding work complete all as specified and as directed. |
| 23 | Material and Labour in replacement of cable resting trolly MS Wheel (with four ball bearing) for upto 3 Ton EOT crane including necessary welding work complete all as specified and as directed. |
| 24 | Material and Labour in replacement of cable resting trolly MS Wheel (with four ball bearing) for 10 Ton EOT crane including necessary welding work complete all as specified and as directed. |
| 25 | Supply and fixing in replacement of shrounded type TPN PVC insulated DSL alluminium Bus bar current collector for DSL system having capacity up to 250 Amps rating (03 Phase & 01 Neutral) complete including welding works as per site requirement all as specified and as directed. Please Enable Macros to View BoQ information |
| 26 | Supply and fixing in replacement of shrounded type TPN PVC insulated DSL alluminium Bus bar current collector for DSL system having capacity up to 250 Amps rating (03 Phase & 01 Neutral) complete including welding works as per site requirement all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender