Tender For Provn Of Charging Station Of 240 Kw Alongwith Associated Work At Hq Wac, Subroto Park Under Ge (Af) Subroto Park
Tender Overview
Project Description
Tender for Provn Of Charging Station Of 240 Kw Alongwith Associated Work At Hq Wac, Subroto Park Under Ge (Af) Subroto Park
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-Sep-2026 | Corrigendum No 2 | Date | 30-Sep-2026 |
| 2 | 10-Sep-2026 | Corrigendum No 1 | Date | 25-Sep-2026 |
| 3 | 10-Sep-2026 | Corrigendum No 1 | Date | 25-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning of Indoor type, step down transformer 11KV/433 Volts (at no load) AC, 3 phases 50 Hz, 315 KVA capacity, core type copper wound on HV & LV coil immerse, naturally cooled, oil natural-air natural (ONAN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV side) in accordance with vector group DYN-11 with neutral brought out on secondary side (LV side) and having 7 step tapings off circuit tap changer (Tapping Range ±7.5% in step of 2.5% each) on HV side to be changed by means of hand operated off load tap changer gear, the maximum temperature rise should not exceed 45 degree Celsius in oil and 55 degree Celsius, the transformer shall be in accordance with latest EEL- 3 of IS : 1180 (Part-1)-2014 with amendment. No. 1 ,2, 3 & 4 and comprise of the following complete all as specified & directed by Engr-in-Charge. Note : Transformer must be BIS Marked and BEE 3 star label. Please Enable Macros to View BoQ information |
| 2 | Supply, installation, testing and commissioning of Indoor type, step down transformer 11KV/433 Volts (at no load) AC, 3 phases 50 Hz, 315 KVA capacity, core type copper wound on HV & LV coil immerse, naturally cooled, oil natural-air natural (ONAN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV side) in accordance with vector group DYN-11 with neutral brought out on secondary side (LV side) and having 7 step tapings off circuit tap changer (Tapping Range ±7.5% in step of 2.5% each) on HV side to be changed by means of hand operated off load tap changer gear, the maximum temperature rise should not exceed 45 degree Celsius in oil and 55 degree Celsius, the transformer shall be in accordance with latest EEL- 3 of IS : 1180 (Part-1)-2014 with amendment. No. 1 ,2, 3 & 4 and comprise of the following complete all as specified & directed by Engr-in-Charge. Note : Transformer must be BIS Marked and BEE 3 star label. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender