Tender For Repairs To E/M Related Works In Hangers Of Army Avn Sqn Including Technical Areas In Aor Of Age B/R Lekhanagar Under Ge Nasik Road
Tender Value
40 Lakhs
Estimated cost
Bid Submission
18 Sep 2026
20 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nashik → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs To E/M Related Works In Hangers Of Army Avn Sqn Including Technical Areas In Aor Of Age B/R Lekhanagar Under Ge Nasik Road
BOQ
| Sl. No. | Item Description |
| 1 | Supply, lay, test and commissionnig of 95 sq mmx3.5 core UG LT cables 1100 Volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc including for all jointing/ connecting material as required size, cables laid in trenches/ducts/ under plinth floors passing through pipes, fixed on wall and taking down old cable complete all as specified and directed. |
| 2 | All as per Ser Item No 1.00 above but for 70 sqmm x 3.5 core |
| 3 | All as per Ser Item No 1.00 above but for 50 sqmm x 3.5 core |
| 4 | All as per Ser Item No 1.00 above but for 35 sqmm x 3.5 core |
| 5 | All as per Ser Item No 1.00 above but for 25 sqmm x 3.5 core |
| 6 | M&L for excavation in trenches n. exc 1.5 m deep & n. exc 1.5 m wide getting out for laying pipes/cables all as reqd in soft/loose soil |
| 7 | M&L for returning filling in trenches with excavated material in layers of 25 cm including spreading leveling well ramming complete all as directed. |
| 8 | M&L for removing surplus excavated material away from site to a distance of 50 m where directed and n. exc 1.5 m above the starting point including spreading leveling etc. complete all as directed. |
| 9 | M&L for DWC Pipe 50mm dia of pressure rating 6kgf/Sqcm laid in trenches as in protection to HT/LT cable of size 10 Sqmm to 95 Sqmm complete all as specified and as directed. |
| 10 | M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia. suitable for 0.4 mPa working pressure. |
| 11 | S&F in replacement of industrial wall mounted socket including industrial plug 32A, 3P+N+E complete with MCB TP 32 Amp. Make - Havells Cat Part No-DHQSB65032 (socket) and DHQBB65032 (plug) or equivalent in other makes as per CA. |
| 12 | S&F in replacement of industrial wall mounted socket including industrial plug 63A, 3P+N+E complete with MCB TP 63 Amp. Make - Havells Cat Part No-DHQSB65063 (socket) and DHQBB65063 (plug) or equivalent in other makes as per CA. |
| 13 | S&F new GI down rod upto 3.00 m, 15mm bore (light grade) with apropriate size of chain connected by means of bolts, nuts, check nuts and washers, including taking down rod of LED high bay light fitting complete all specified and as directed. Note: Ladder, safty belt and other safty eqpt to be provided by contractor at no extra cost. |
| 14 | Supply, fix, test and commissioning highbay light min 150W LED, minimum system lumen output of 16500 lm. The luminnare should have colour temperature of 5700/6500K and THD<10%, CRI>70 and should meet IP66 ingress protection and impact resistance IK07 and luminaire housing should made of pressure die-cast aluminium and itegrated PC Lens. The luminaire should have the features of high Voltage, 10 kV external surge protection long life of LEDs 50,000 burning hours (L70), integrated potted LED driver offers comfortable softlight, high durability, Driver safety requirement standards as per IS 15885-2-13 complete all as specified.Note:- Test certificate to be submitted for Photobilogical safety norms as per IS 16108. |
| 15 | S&F LED luminaire 600x600 mm, 35/36 Watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size complete. |
| 16 | S&F in repair SP&N enclosure with 2 pole, 240 Volts and earth metal plug & socket for incorporating 20 A MCB SPN complete all as specified and as directed. Note:- MCB 20 Amp SPN is also part of the item. |
| 17 | S&F LED light fitting 1x20W, 220V, AC, decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 18 | S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 Watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 19 | S&F round shape 6 Watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 20 | S&F round shape 12 Watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 21 | S&F 35 Watt LED streetlight fitting luminaire made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP opening seperate driver compartment with IP66 protection and impact resistance of IK07, including coneecting up with 2/3 core flexible coppper conductor cable, compete all as specified and as directed. |
| 22 | Supply, fix, test and commissioning flood light min 100W LED, min system lumen output of 16500 lm. The luminnare should have colour temperature of 5700/ 6500K and THD<10% CRI>70 and should meet IP66 ingress protection and impact resistance of IK07 and luminaire housing should made of pressure die-cast aluminium and integrated PC Lens. The luminaire should have the features of high Voltage 10 kV external surge protection long life of LEDs 50,000 burning hours (L70), integrated potted LED driver offers comfortable softlight, high durability, Driver safety requirement standards as per IS 15885-2 -13. Note:- Test certificate to be submitted for Photobilogical safety norms as per IS 16108.Make: Crompton Cat No. TFS-504-70-57-60D-SL-GL-NSG or equivalent in other makes as per CA. |
| 23 | Supply, fix, test and commissioning flood light min 200W LED, min system lumen output of 16500 lm. The luminnare should have colour temperature of 5700/ 6500K and THD<10% CRI>70 and should meet IP66 ingress protection and impact resistance of IK07 and luminaire housing should made of pressure die-cast aluminium and integrated PC Lens. The luminaire should have the features of high Voltage 10 kV external surge protection long life of LEDs 50,000 burning hours (L70), integrated potted LED driver offers comfortable softlight, high durability, Driver safety requirement standards as per IS 15885-2 -13. Test certificate to be submitted. Photobilogical safety norms as per IS 16108. Make : Crompton Cat No. TFS-504-70-57-60D-SL-GL-NSG or equivalent in other makes as per CA. |
| 24 | S&F in repair LED Gate light of capacity 35 Watt for installations indirect light with IP 65 protection, resistant to impact and corrosion glare free and better uniformity.Make: Crompton Cat No CBP-610-35-57-SL-CA-NBK or equivalent in other makes as per CA. |
| 25 | S&F in repair LED Post top light of capacity 20 Watt indirect light with IP 65 protection, complete including necessary foundation.Make : Crompton Cat No. LPTH-20-CDL or equivalent in other makes as per CA. |
| 26 | S&F in repair LED Bollard light of capacity 10 Watt for installations indirect light with IP 65 protection, inverted Pyramid Tripod type with soft 360 degree light distribution complete including necessary foundationMake : Crompton Cat No. LBLSN-10-CDL or equivalent in other makes as per CA. |
| 27 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC casing capping not less then 20mm dia medium Grade fixed on walls/roof/floors all as directed.Notes: Two wires of 2.5 sqmm and one wire of 2.5 sqmm for earthing and one run of PVC casing/caping shall be measured as one unit. Ladder, safty belt and other safty eqpt to be provided by contractor. |
| 28 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4 Sqmm to be drawn through and including PVC casing capping not less then 32mm dia medium Grade fixed on walls/roof/floors all as directed.Notes:- Two wires of 4 sqmm and one wire of 4 sqmm for earthing and one run of PVC casing capping shall be measured as one unit. Ladder, safty belt and other safty eqpt to be provided by contractor. |
| 29 | S&F sheet metal enclosure factory made for DBs single pole and neutral double door 240 Volts, 8 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and as directed. |
| 30 | S&F in repair F MCB DB made of sheet metal powder coated with acrylic door suitable for surface mounting with 100A copper bus bar for each phase with neutral bar & earth bar cable ties for cable management, fully insulated bus bar & shrouded neutral bar, pmproved pan assembly for ease of installations, prefitted masking sheet, reversible door for IP 43 DBs with provision for incoming MCB & outgoing MCBs with IP-43-IK09 protection grade, 415 Volts TPN with 4 way Double door all as specified & directed |
| 31 | S&F VTPN MCCB DB prewired made of sheet metal powder coated suitable for surface mounting with 250A copper bus bar for each phase with 2 neutral bar & 2 earth bar cable ties for cable management, fully insulated bus bar & shrouded neutral bar, pmproved pan assembly for ease of installations, prefitted masking sheet, reversible door for IP 43 DBs with provision for incoming MCCB & outgoing MCBs with IP54-IK09 protection grade, 415 Volts TPN with 8way Double door all as specified & as directed |
| 32 | S&F in repair F TPN/FP 40 to 100 AMP, 415V 10 kA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning. |
| 33 | S&F in repair MCB SP 240 Volts, 'C' series, breaking capacity 10 kA of rating 6-32 Amps complete all as specified and as directed. |
| 34 | S&F in repair MCB SPN 240 Volts, 'C' series, breaking capacity 10 kA of rating 40-63 Amps complete all as specified and as directed. |
| 35 | S&F in repair MCCB TPN, 4 Pole 125 A, 415 V, breaking capacity 16 kA, adjustable tripping, suitable for isolation complete all as specified and as directed. |
| 36 | S&F in repair MCCB TPN, 4 Pole 63 A, 415 V, breaking capacity 16 kA, adjustable tripping, suitable for isolation complete all as specified and as directed |
| 37 | S&F in repair MCCB TPN 100 Amp, 4 pole, 415 Volts 16 kA adjustable tripping, suitable for isolation complete all as specified and as directed |
| 38 | S&F in repair galvanized earth strip 32x6 mm for earthing from earth plate to equipment complete fixed on pocelain insulator every 1 m interval all as specified and as directed. |
| 39 | S&F in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw. |
| 40 | S&F in repair Aluminium strip 25x3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. |
| 41 | S&F in repairs air termination, single pointed aluminum rod 12mm dia and 300mm long complete all as specified and as directed. |
| 42 | Fixing in repairs aluminium strip 25x3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. Note item No 39 to 42: Ladder, safty belt and other safty eqpt to be provided by contractor. |
| 43 | S&F in repair AUXILLIARY VOLTAGE TRANSFORMER having VTR:11000/√3 // 230/√3 V AC, BURDEN : 500VA, BIL : 28 kVrms/75kVpK,HRCA fuse at the primary side, Copper PT Connection VT12, MGVCL, 12 RMU, Copper PT Conn 2 VT12, MGVCL, 12RMU including necessary wiring with copper wire 2.5 sqmm complete all as directed |
| 44 | M&L for Chemical Earthing complete with copper earth plate electrode 900x600x5 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below ground level connecting to the Copper earth strip 32x 6mm, by means nut bolt, nuts, check nuts and washer of the copper Earth strip protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC 1:2:4, type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC 1:2:4, reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25x25x3 mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 m long placed on top edge of earth plate, with ground enhancing backfill compound (Safe ground). The charastricts of this compound is highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities. (Each earthing = 25 kgs 4 bag), test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 m, all as per SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”. |
| 45 | S&F copper earth strip 20x3 mm for earthing from earth plate to equipment complete fixed on porcelain insulator every 1 m interval all as specified and as directed. |
| 46 | NOTE: AMOUNT OF SCHEDULE OF CREDIT Rs. 1,45,495.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysSep 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender