Tender For special Repair Of Bldg No P-19 (Otm) Of Hq Cosa And Reinforced Cement Concrete Oh Water Tank Installation Bldg No P-27 Under Age (I) Naya Raipur
Tender Value
54.07 Lakhs
Estimated cost
Bid Submission
26 Sep 2026
26 days left
EMD
1.07 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Raipur → Chhattisgarh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair Of Bldg No P-19 (Otm) Of Hq Cosa And Reinforced Cement Concrete Oh Water Tank Installation Bldg No P-27 Under Age (I) Naya Raipur
BOQ
| Sl. No. | Item Description |
| 1 | Notes applicable for Overhead Tank: Double steel scaffolding system (cup lock type) shall be provided on the exterior side of the building/structure, including additional rows of scaffolding in stepped manner as per requirement at site, made with 40mm dia MS tube, placed 1.5mtr c/c (Maximum), horizantal & vertical MS tubes jointed with cup & lock system in the scaffolding for working platform etc and maintaining it in a serviceable condition for execution of work and removing it thereafter. The scaffolding system shall be stiffned with bracings, runners, connecting with building etc wherever required to ensure safety of workmen all as directed by Engr-in-charge. The scaffolding shall be contractors own arrangment and No extra payment will be made by Dept on this account. After completion of the work the material of the scaffolding shall required to be removed from the site. Proper safety belts and helmets to be provided to the workers at site to follow safety precautions |
| 2 | M&L clean the surface thoroughly, it should be free from oil, grease,dust,dirt, fungus and moss. Through wire brushing or using mechanical grinding m/c. Crack Preparation: cutting cracks in \\"V\\" groove and fill the cracks & grooves with Dr. Fixit Dampguard classic and cement modified putty. Application : i) Apply a coat of Dr. Fixit Dampguard Classic. Let it dry for 24 hrs ii) Apply second coat of Dr. Fixit Dampguard classic. Allow it to air cure completely for 7 days. |
| 3 | M&L for Providing water proofing treatment against dampness & seepage on RCC roof consisting of following operations: i) Drilling holes in the affected area of slab . ii) Fixing injection packers (size: 10mm x 60mm) at the drilled holes. iii) Connecting injection packer to injection pump for the injection of double component type high strength polyurethane(PU). iv) Removing the projected packers from the substrate. |
| 4 | Taking down cement plaster on brick or stone walls, ceilings, etc including racking out Joints, hacking for key, scrubbing down with water, etc all as specified and directed by engineer-in-charge. |
| 5 | Demolition of cement un-reinforced concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing the rubbish off the premises complete all as specified and directed by engineer-in-charge. |
| 6 | Removing building materials etc. to a distance of 1000 m, beyond the lead included in the rates , including loading, unloading and stacking at the destination complete all as specified and directed by engineer-in-charge. |
| 7 | M&L 75 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base cement concrete surfaces complete all as specified and directed by engineer-in-charge. |
| 8 | M&L sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by engineer-in-charge. |
| 9 | Dismantling of stone slabs and tiles of any description or thickness in floors, aproons etc laid bedded and pointed in any mortar complete all as specified and directed by engineer-in-charge. |
| 10 | M&L for machine pressed precast concrete interrlocking paver block any shape and size with gray cement and no pigment confirming to IS 15658-2006 of 60 mm thickness M-35 Grade laid over and complete all as specified and direced by engineer-in-charge. |
| 11 | M&L 15mm thick rendering on fair faces of brick or concrete surface in Cm (1:4) and providing in two layers finishing even and smooth without using extra cement all as specified and as directed. Note :- WPC shall be measured and paid seperately under relevant item here-in above. |
| 12 | Supply only water proofing compound. |
| 13 | Blank |
| 14 | M&L for applying two or more coat of 100% premium acryclic emulsion paint having VOC having 50 gm/litre and UV resistance as per IS-15489:2004 , alkali and fungal resistance exterior paint of required shade (company depot tinted) with silicon additive @ 1.43 litres per 10 sqm over a coat of wall care putty 2 mm thick and including priming coat of exterior primer applied @ 0.90 litre per 10 sqm over new surfaces all as specified and directed. |
| 15 | M& L for cement concrete in foundations, filling and mass concrete of type D-2 1:4:8 (40 mm graded aggregate) complete all as specified and directed. |
| 16 | Demolition of brickwork built in cement mortar complete all as specified and directed |
| 17 | M&L for brickwork with fly ash modular bricks, straight or curved on plan exc 6m mean radius in 1:6 CM complete all as specified and directed. |
| 18 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all specified and directed. |
| 19 | S&F joist , channel angle or tie sections fixed independently without connecting plates etc as in posts and struts in fencing including cutting tops to shape as directed , drilling holes , notching for wire etc ,flat iron fillets ( for securing wire etc ) including all necessary drilling , bolting or riveting, etc and similar work all as specified and direcetd. |
| 20 | Dismantling fencing wire mesh and any type all as specified and directed. |
| 21 | Fixing only chain link fencing including line wires any mesh,any mesh,size and any type of standards,rails,straining bolts,etc including provision of binding wire all as specified and directed. |
| 22 | Supply only chain link MS galvanised fencing any size or type complete. |
| 23 | M&L mild steel screw bolts (machine Made) with hexagonal or square heads at one end and screwed the other to be fitted with washer and one hexagonal or square nut n exc 5 cm long, dia of shank 5 to 10 mm complete all as specified and as directed. |
| 24 | M&L applying two coats of synthetic enamel paints on new steel surfaces over a coat of red oxide primer including surface preparation all as specified and directed. |
| 25 | M&L framed work as in doors or gates of angle or other section with gusset plates, rails,braces etc. , complete, drilled for fixing of steel sheeting or other coverings. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete of FE 410-W Gde- E-250 complete all as specified and as directed. |
| 26 | Dismantling posts or struts (wood,steel or RCC) any section, including taking out embedded portion in concrete,brick work, masonry etc. and making good disturbed ground complete all as specified and directed. |
| 27 | Demolition reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 28 | M & L for RCC work (nominal mix) in column, pillars , piers, posts and struts of type B1 1:2:4 (20 mm graded aggregate) complete all as specified and directed. |
| 29 | Use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all specified and directed. |
| 30 | S&F mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 31 | Ditto, but 6 mm to 8 mm dia. complete all as specified and directed. |
| 32 | M&L for framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framerork of water tanks and similar work confirming to Fe 290.Gde-E-165 complete all as specified and directed. |
| 33 | Supply and erection of LED aviation obstruction light with polycarbonate diffuser luminaire and cast Aluminium Housing with suitable accessories, nut & bolts complete all as specified. |
| 34 | S&F submain wiring along with earth wire of size 2x2.5 sqmm + 1x25 sqmm earth wire of FR is PVC insulated copper conductor, single core cable in surface/recessed as required in PVC conduit complete all as specified and directed. |
| 35 | S&F air termination, single pointed aluminium rod 12mm dia & 300mm long complete all as specified and directed. |
| 36 | S&F Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all specified and as specified. |
| 37 | S&F Galvanised iron strip 32 x 6mm buried in ground complete all as specified and as directed. |
| 38 | S&F test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos., 8mm dia 25 mm long hex, Head screw complete all as specified. |
| 39 | M&L for tubes, light grade, galvanised, 40mm dia with all fittings, fixed on wall/roof/laid in trenches/floor etc complete all as specified. (for cable protection) |
| 40 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete. |
| 41 | Supply and laying of cable XLPE Insulated screened Meter PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm x 4 core complete all as specified and directed. |
| 42 | Supply & fix in repair FRP junction box Size, IP-65, weatherproof outside dimension 250x200x105 mm, IP65 protection with plain wall for cable of size 25sqmm, size 126x228x111 (min) Including 20mm connector MCB 6Amp SP-01 Nos with suitable bus bar arrangements and fix on pole with and including MS clamped out of 25x3 mm MS flat iron, nut bolts etc complete all as specified and directed. |
| 43 | Earthing complete with galvanised steel earth plate electrode 680×80cm.x 6mm thick, burled directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, using galvanised iron strip 32×8mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. |
| 44 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out for laying of pipe cables etc, and getting out complete all as specified and directed. |
| 45 | Returning filing in, including spreading levelling, watering and well ramming in layers not exceeding 25cm thick with earth obtained from excavation complete all as specified and as directed. |
| 46 | Removal of surplus excavated soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above starting point complete, all as specified and directed by engg in charge. |
| 47 | Material and labour for dry river washed and screened dry sand for filling in trenches/ ground 8cm thick before laying of cable and 15 cm thick after laying of cable, stretching and testing the cable complete all as specified and directed.Note:-Punned thickness shall only be measured and paid. |
| 48 | Supplying and laying un-nsinforced precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed. |
| 49 | Supply and fixing, testing and Commissioning for replacement of Water level indicator for Overhead tank (Float and Board level) with stainless steel float, steel wire, brass pullies with nylon bush and angle and angle iron stiffners front face of the board shall be painted with two coats of synthetic enamel paint over a coat of redoxide primer, mark level with two coats of black synthetic emamel paint over a coat of redoxide primer complete all as specified and directed by Engr-in-Charge |
| 50 | Supply and fixing, Testing and Commissioning for replacement of, CI sluice valve with fianged ends, cast iron body flanged and drilled end non rising type, HT bronze spindle with nuts, class PN-1.6 suitable for 80mm bore as per IS: 14826, ISI marked including all joints with rubber or fibre board, bolts and nuts, washers etc complete all as specified. |
| 51 | -ditto- but 100 mm dia |
| 52 | -ditto- but 150 mm dia |
| 53 | -ditto- but 200 mm dia |
| 54 | Material and Labour in repairs for valve chamberof size 1200 X 900 X 900MM depth (inetmal dimension) removing the damaged cover, Plastering the broken areas with CM 1:4, 15mm thick in the ratio including painting with antifungal paint of 2 coats inside and out side the wall of chamber including replacing the MS sheet cover 3 mm thick with angle iron frame 25 x 25 x 4mm, locking arrangement complete with painting on steel surfaces with one coat of red oxide paint over two coats of synthetic enamalled paint all as specified and and directed. |
| 55 | Supply & laying in replacement of medium grade Gl tubing laid in tenches/fixed on wall with all fittings complete of size 80mm bore all as specified and and directed. |
| 56 | Supply & laying in replacement of medium grade Gl tubing laid in tenches/ fixed on wall with all fittings complete of size 100mm bore all as specified and and directed. |
| 57 | Supply & fix ductile iron fittings in replacement, conforming to IS 9523 K 12 for spigot and socket pipe class K9 suitable for 150 mm dia pipe such as bends (any type radius and angle), tappers, decreasing or double socket etc), tee tail pieces, single branch, Y junction double brach cross collars, caps and plug complete all as specifed and directed. |
| 58 | Supply & lay ductile iron pipe in replacement, Flanged including specials class K9 suitable for 150 mm (6\\") dia complete all as specifed and directed. (Old DI socketed pipe to be deposited to MES store yard and taken in ledger charge) |
| 59 | M&L for run lead joint in repair, suitable for DI/CI as specified and directed for 150mm bore size. pipe/fitting spigot & scoket complete all as specified and directed. |
| 60 | Supply and laying of cable XLPE Insulated screened Meter PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm x 3.5 core complete all as specified and directed. |
| 61 | Supply and laying in repair of light grade galvanised tube 40 mm bore with all fittings and fixed to walls / ceiling or laid in floor, pole or laid in trenches and road crossings including sealing ends with hession cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed with walls / poles complete all as specified and as directed. |
| 62 | Taking down of chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm (without taking off shutters from the frames) complete all as specified and as directed. |
| 63 | Taking down shutters of any description Exc 2 sqm each complete all as specified and as directed. |
| 64 | S&F 30mm flush shutters,solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified. |
| 65 | S&F 30mm thick second class hard wood glazed and skelton shutters open rebated and prepared to receive glass or gauge etc (without sash bar) edges of framing plain,chamfered or rounded fitted with cut and mitred beads for securing glass, size of members of shutter etc complete all as specified and direcetd.Note :- Size of member of shutters as specified in SSR Part-I section 8 clause 8.24(a) |
| 66 | S & F framed work Fe-290 grade, as in chowkats or frame of door or gates of angle or other section with gusset plate , rail braces etc complete drilled for fixing of steel sheeting or other covering , doors etc to be prepared for hanging or sliding with and inclu either hooks and hinges or steel hanging door fiting complete all as specified. |
| 67 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 68 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 69 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, devotailed or welded complete all as specified and as directed. |
| 70 | S&F steel windows with side hung shutters including projecting type hinges with steel handles, and steel peg stay complete without glazing bars, dovetailed or welded complete all as specified and as directed. |
| 71 | S&F steel ventilator with top hung shutter including incl hinges steel peg stay complete all as specified and directed. |
| 72 | M&L framed work such as grills grating etc with end of bars shoulderd and/or riveted .welded or forged into spikes.framedguard bars iron doors.ladders framed balusters , walk ways. Railings, frame work of water tanks and similar work conforming to Fe410 complete all as specified and directed. |
| 73 | S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane complete all as specified and directed. |
| 74 | S& F galvanised mild steel wire clothes 0.56 mm nominal dia of wire and average width of aperture1.18 mm complete all as specified and as directed . |
| 75 | S&F for 100mm long butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed. |
| 76 | S&F mild steel spring for doors 300mm long, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 77 | S&F 250 mm long mild steel sliding door bolts, bolt or clip type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed. |
| 78 | S&F 150mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed all as specified and directed. |
| 79 | S&F haps and staple 150mm long safety type aluminium anodised with mild steel hing pin including bolt to hing plate and fixed with screws all as specified and directed. |
| 80 | M&L applying two coats of synthetic enamel paints on new steel surfaces over a coat of red oxide primer including surface preparation complete all as specified and as directed. |
| 81 | M&L preparing old wood or wood based surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 82 | M&L preparing new wood or wood based surfaces of any description over 10 cm width or girth and applying Two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 83 | M&L Cutting chases, pinning in making good to facing on brick walls & pointing in CM 1:3 for concealed water tubing cutting n exc 10 cm girth all as specified and as directed. |
| 84 | S&F 140 mm floor door stopper of aluminium alloy body and tongue , anodised ,with hard drawn steel spring ,fixed in floor all as specified and directed. |
| 85 | S&F in repair fancy type Curtain rod MS conduit PVC coated including fancy type knob curtain rod end with fancy type MS bracket for hanging curatin rod complete all as specified and directed. |
| 86 | Dismantling floor hearth or wall tilling including cement mortar bedding (but not backing ) removing serviceable tiles to store and rubbish off the premises all as specified and directed. |
| 87 | M & L light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and incl 15 mm thick screed bed in CM(1:4) for laying floor finished complete all as specified and directed. |
| 88 | M&L providing Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles laid over and including rendering 10 mm thick plaster in CM (1:4) on brick concrete surface complete all as specified and directed. |
| 89 | M&L rendering 12mm thick in cement plaster 1:6 on surfaces other than fair faces of brick work and surface finished even and smooth without using extra cement complete all as specfied and direcetd. |
| 90 | M&L rendering 5 mm thick in cement mortar 1:3 on concrete surfaces of ceilling as specified and directed. |
| 91 | M&L preparing Old plastered or unplastered surfaces of ceiling and applying one coat of white wash complete all as specfied and direcetd. |
| 92 | M&L for preparing newly plastered surfaces of walls and applying two coat of white wash complete all as specfied and directed |
| 93 | M&L for preparing old plastered surfaces of walls and applying one coat of whitewash complete all as specfied and directed |
| 94 | M&L for preparing newly plastered surfaces of ceiling and applying two coat of whitewash complete all as specfied and directed |
| 95 | M&L for two coat of oil bound distemper incl preaparation of new plastered surface complete all as specfied and directed |
| 96 | M&L for one coat of oil bound distemper on old surface of wall complete all as specified and directed. |
| 97 | M&L for one coat of synthetic enamel paint on old painted steel surfaces of any description over 10 cm width or girth including preparation of old painted wooden surface of all complete all as specified and directed. |
| 98 | Providing PCC 1:3:6 type C-2 (40 mm stone agg) as in plinth protection 75 mm thick finishing cement concrete even amd smooth without ung extra cement all as specified and directed. |
| 99 | M&L 40mm thick PCC 1:2:4 type B1 using 20mm graded stone agg laid in panel finished even & smooth with using extra cement as in flooring complete all as specified and as directed. |
| 100 | Supply only glass dividing strip 3mm thick and 22mm wide in flooring complete all as specified and directed |
| 101 | S&F in repairs bib taps 15mm dia cast copper alloy chromium plated with crutch or butter fly handle screwed down for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 102 | S&F in repair 15mm bore angle stop valve of cast copper alloy chromium plated high prssure screwed for iron pipe and fixed all as specified. |
| 103 | S&F in repair vitreous china wash basin white, flat, back, size 550x400 mm excluding tap waste but including brackets and including cutting for and pinioning in ends of brackets but exclusive of supply waste pipe all as specified |
| 104 | S&F Pillar taps 15mm dia cast copper alloy, with capstain heads chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shank or fly nuts screwed for iron pipe and fixed complete |
| 105 | S&F 32mm dia wast fittings brass chromium plated for basin with long screwed shank and fly nuts, flange end bedded in red lead cement and other end fixed. |
| 106 | S&F 600mmx450mm bevelled edges mirror consisting of 5.5mm thick commercial plywood and fixed to plug with chromium plated brass screwed and cup washer |
| 107 | S&F PVC connection 15mm bore length not less than 300 mm long with both ends PTMT nuts complete all as specified. |
| 108 | S&F 32mm bore low density polyethylene pipes (LDPE) pressure rating 6 kg/ cm2 of fixed complete to walls, ceiling or laid in floors all as specified. |
| 109 | S&F, kitchen sink with drainage board made out of 1mm thick stainless steel with plugs, washers & wastes including CI cantilever bracket & connection union to pipe over all size 915mmx460mm & bowl size 410 x330x160mm complete all as specified and as directed |
| 110 | Dismantling of water tanks of exc 500 ltrs n.exc 1000 ltrs capacity and removing to store complete all as specified and as directed |
| 111 | S&F rotational moulded polethylene water tank of 1000 ltrs capacity ( cylindrical vertical with closed top) hoisted and fixed in position INCLUDING 15 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and directed. |
| 112 | Dismanteling of water tank of exc 1000 ltrs n.exc 2000 ltrs capacity and removing to store complete all as specified and directed. |
| 113 | S&F rotational moulded polethylene water tank of 2000 ltrs capacity ( cylindrical vertical with closed top) hoisted and fixed in position INCLUDING 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and directed. |
| 114 | S&F in repairs plastic sheet covers for water closet,black,closed pattern with flat bottom with mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 115 | S&F in repairs 10 ltrs capacity (PVC),valve less,syphonic action type ,flushing cisten low level white with inlet ball valve float and handle including brackets complete all as specified and directed. |
| 116 | S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed. |
| 117 | S&F in repair 40 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 118 | S&F in repair 25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 119 | Taking up or down existing steel tubing and connections including cleaning for refixing or removal to stores complete all as specified and directed for 15mm bore complete all as specified and directed. |
| 120 | Taking up or down existing steel tubing and connections including cleaning for refixing or removal to stores complete all as specified and directed for 20mm bore |
| 121 | S&F 15mm bore GI water tubing medium grade galvanised with all fittings and fixed complete to walls and ceilling or laid in floor complete all as specified and directed. |
| 122 | S&F 20mm bore GI water tubing medium grade galvanised with all fittings and fixed complete to walls and ceilling or laid in floor complete all as specified and directed. |
| 123 | Refixing 15mm bore old steel water tubing and connection in new or old position (walls, ceilling, floor etc) complete all as specified and directed. |
| 124 | Refixing 20mm bore old steel water tubing and connection in new or old position (walls, ceilling, floor etc) |
| 125 | Taking up or down existing asbestos cement pressure pipe (100mm dia) any class ,(including all fitting ) including disconnecting pipes and fittings complete. |
| 126 | S&F 75 mm bore PVC (SWR) pipes of single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 127 | S&F 75 mm bore PVC (SWR) pipes of single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 128 | S&F 75 mm bore. PVC (SWR) bends all as specified and directed. |
| 129 | S&F 75mm bore.PVC(SWR) junction single (single T) equal or unequal all as specified and directed. |
| 130 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches all as specified and directed. |
| 131 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall all as specified and directed. |
| 132 | S&F 110mm bore PVC (SWR) bends complete all as specified and directed. |
| 133 | S&F 110 mm PVC (SWR) bend any radius all as specified and directed. |
| 134 | S&F 110mm bore.PVC(SWR) junction single (single T) equal or unequal with access door all as specified and directed. |
| 135 | S&F 100 mm dia stack clamps out of 50mmx5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stays to ball or roof complete all as specified and directed. |
| 136 | M&L brick work with old size fly ash bricks straight or curved on plan exc 6m mean radius built in cement and sand mortar 1:4 complete all as specified . |
| 137 | M&L formachine cut mirror polish kota stone slab flooring 18-20mm thich over 20mm thick screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigmen to match the shad of the slab including round nosing at corners rubbing and polishing .complete all as specified and directed. |
| 138 | M&L for machine cut mirror polish kota stone slab 18-20 mm thick in riser of step,skirting,dado and pillers over and including 10mm thick rendering in CM 1:4 including rubbing and polishing .complete all as specified and directed. |
| 139 | M&L for mirror polishing on marble/granite/kota stone/stone work where ever required to give high gloss finish complete all as specified and directed. |
| 140 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 141 | S&F in repair of Point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 sqmm (nominal area), single core, flame retardant low smoke(FRLS), PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked TEC and FIA approved in and including PVC casing & capping and its fittings ISI marked, with mild steel sunken boxes suitable for modular/normal switch/sockets etc with earth dolly duly painted with two coats of anti corrosive paint over a coat of red oxide primer internally, incl covered with suitable module cover plate with frame including flame retardant low smoke (FRLS) PVC insulated unsheathed stranded copper conductor 1.5 sqmm (nominal are) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified for the followings :- |
| 142 | (a) One light/Fan/Bell point controlled by one switch |
| 143 | (c) One socket out let 5 pin 5 Amp on independent board |
| 144 | (d) One socket out let 5 pin 5 Amp on same board |
| 145 | All as per item No 140 above but one light point controlled by two way switch complete all as specified and directed. |
| 146 | All as per item No 140 above but using 4.0 Sqmm cable for one 15 A socket outlet point with 2.5 Sq mm PVC insulated, unsheathed copper conductor cable as earth continuity conductor complete all as specified and directed. |
| 147 | Supply and fix in repair modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 148 | S & F in repair Modular socket outlet 1 way 6 Amps 2/3 pins combined, 2 module complete all as specified and directed. |
| 149 | Supply and fix in repair modular switch 1 way 16A, 1 module complete all as specified and directed. |
| 150 | S & F in repair Modular socket outlet 1 way 6/16 Amps - 2/3 pins combined, 2 module complete all as specified and directed. |
| 151 | S & F in repair for Modular switch 2 way 6A, 1 module with cover plate and frame 1 module complete all as specified and directed. |
| 152 | S & F in repair modular fan regulator, 120 watts, ISI marked, 2 module step type complete all as specified and directed. |
| 153 | S & F in repair White cover plate with frame, 1 module including metal flush box 1/2 module complete all as specified and directed. |
| 154 | S & F in repair White cover plate with frame, 2 module including metal flush box 1/2 module complete all as specified and directed. |
| 155 | S & F in repair White cover plate with frame, 3 module including metal flush box 3 module complete all as specified and directed. |
| 156 | S & F in repair White cover plate with frame, 4 module including metal flush box 4 module complete all as specified and directed. |
| 157 | S & F repair White cover plate with frame, 6 module including metal flush box 6 module complete all as specified and directed. |
| 158 | S & F in repair White cover plate with frame, 8 module complete all as specified and directed. |
| 159 | S & F in repair modular metal flush box 8 module complete all as specified and directed. |
| 160 | S & F in repair for Bell, AC, 230 volts, single pole complete all as specified and directed. |
| 161 | S & F in repair for ceiling rose 3 phase/PVC/polycarbonated isolated body complete all as specified and directed. |
| 162 | M&L in rep for single pole enclosure with a two pin and earth plug and socket complete with one single pole MCB 20Amps, Complete all as specified and as directed by Engr-in-Charge. |
| 163 | Supply and fixing in repair LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 164 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 165 | Supply and fixing in repair round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 166 | Supply and fix building security light of 35/36 watt, IP 65 ,LED die casting aluminium with LED street optic lenses ,efficacy of skyline plus is upto 120lm/w, with pea nut lenses LED type with bracket arrangement all as per required and directed by Engg in Chrge. |
| 167 | Supply and fix in repair Bracket holder surface mounted, PVC/ Polycarbonate type with back plate fixing with appropriate size screws / gutties for batten fittings complete all as specified and directed. |
| 168 | Supply and fix in repair LED lamp 9W suitable for LED fittings, connectors block etc. complete all as specified and directed. |
| 169 | Taking down ceiling fans, exhaust fan sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and directed. |
| 170 | M&L for painting of ceiling fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed. |
| 171 | M&L in repair for hanging only ceiling fan and connecting up with provision of cable from ceiling rose or connector to fan complete all as specified. |
| 172 | S & F in repair for MCCB DB's 6 Way VTPN, 415 volts for mounting MCCB as incomer and MCB SP/TP as outgoint as per IS specification of factory made fabricated out of CRCA sheet 1.2 mm thick powder coated fitted with DIN Channel neutral link and double door type inner door fixed on spring loaded hinges with locking arrangement & outer door openable hinged with locking arrangement having IP-43 protection complete all as specified and directed. |
| 173 | S & F in repair for MCB DB's 4 Way TPN, 415 volts for mounting MCB as incomer and MCB SP/TP as outgoint as per IS specification of factory made fabricated out of CRCA sheet 1.2 mm thick powder coated fitted with DIN Channel neutral link and double door type . Inner door fixed on spring loaded hinges with locking arrangement & outer door openable hinged with locking arrangement having IP-43 protection complete all as specified and directed. |
| 174 | S & F in repair for MCB DB's 6 Way TPN, 415 volts for mounting MCB as incomer and MCB SP/TP as outgoint as per IS specification of factory made fabricated out of CRCA sheet 1.2 mm thick powder coated fitted with DIN Channel neutral link and double door type . Inner door fixed on spring loaded hinges with locking arrangement & outer door openable hinged with locking arrangement having IP-43 protection complete all as specified and directed. |
| 175 | S & F in repair for MCB DB's 8 Way TPN, 415 volts for mounting MCB as incomer and MCB SP/TP as outgoint as per IS specification of factory made fabricated out of CRCA sheet 1.2 mm thick powder coated fitted with DIN Channel neutral link and double door type . Inner door fixed on spring loaded hinges with locking arrangement & outer door openable hinged with locking arrangement having IP-43 protection complete all as specified and directed. |
| 176 | S & F in repair for MCB DB's 8 Way SPN, 240 volts for mounting MCBs/RCBO's ELCB's etc. as per IS specification of factory made fabricated out of CRCA sheet 1.2 mm thick powder coated fitted with DIN Channel neutral link and 200 Amps rated bus bar.The DB's shall double door type . Inner door fixed on spring loaded hinges with locking arrangement & outer door openable hinged with locking arrangement having IP-43 protection complete all as specified and directed. |
| 177 | Supply and fixing in repair 415V 'C' curve MCCB of 100 Amps TPN, 16 KA and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed. |
| 178 | S & F in repair for MCB TPN 63 Amps 415 Volts B Curve 10 KA complete all as specified and directed. |
| 179 | S & F in repair for MCB SPN 50 Amps 240 Volts 'C' Curve 10 KA complete all as specified and directed. |
| 180 | S & F in repair for MCB SP 40 Amps 240 Volts B Curve 10 KA complete all as specified and directed. |
| 181 | S & F in repair for MCB SP 10 Amps 240 Volts 'C' Curve 10 KA complete all as specified and directed. |
| 182 | S & F in repair Sub main wiring with approved colour coding as per IS with two runs of single core PVC insulated cable FRLS with Multi Strand copper conductor of size 4 Sq. mm and drawing into PVC conduit including one run of PVC insulated 4 sqmm stranded copper conductor earth wire complete all as directed. |
| 183 | S&F in repair, Sub main wiring with approved colour coding as per IS with four runs of single core PVC insulated cable FRLS with Multi Strand copper conductor of size 6 Sq. mm and drawing into PVC conduit including One run of PVC insulated 6 sqmm stranded copper conductor earth wire complete all as directed. |
| 184 | M&L in repair of Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 185 | M & L for taking down window/split type AC of any capacity by disconnecting the existing cable connection, kept in store and re-fiixing by connecting with AC metal box/Socket after wall panelling of the room including testing of AC at the satisfactory level of Engr-in-Charge. Note : AC metal box/Socket will be measured and paid separately |
| 186 | Fixing only Exhaust fan any type any make any capacity after taking down complete all as specified and directed. |
| 187 | M&L in repair for painting of Exhaust fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed. |
| 188 | Schedule of credit amount of Rs. 1,97,588.00 to be deducted during AOC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 26 daysOct 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 33 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender