Tender For Repair/Maintenance Of Electric Installation, Lt Panels, Fountain Panels And Allied Works At National War Memorial.
Tender Value
35 Lakhs
Estimated cost
Bid Submission
18 Sep 2026
7 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maintenance Of Electric Installation, Lt Panels, Fountain Panels And Allied Works At National War Memorial.
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority:Executing Agency, NWM&M, HQ IDS Name of Work :Repair/Maintenance of Electric installation, LT Panels, fountain panels and allied works at National War Memorial. Contract No: PD/EANWMM/……./2026-2027 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE 'A' (BoQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge. |
| 3 | Returning filling including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed. |
| 4 | Removing excavated soil from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Dy Project Director. |
| 5 | Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified. |
| 6 | S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Dy Project Director. |
| 7 | M & L for servicing of DG set 250 KVA capacity of by taking out unserviceable spares,cleaning by brushing to remove dust including cleaning of filter,checking of all nuts, bolts tightening wherever necessary,check up engine oil level, coolant level and labour for top up if necessary, adjustment belt tension,tuning of engine, adjustment of speed, alternator voltage, frequency etc, greasing, oiling and checking for smooth functioning of DG Set complete all as specified and directed. Make- Cumins JacksonNote :- 1. Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured and paid for separately under respective items.2. Minor spares like nuts,bolts etc costing each shall be deemed included in the rate quoted above |
| 8 | M&L for re-painting of DG set outer body/canopy, exhaust silencer, Fuel tanks and base of DG set with 2 coats of super enamel paint over a coat of red-oxide with spary gun as directed. |
| 9 | Supply and fixing in repair lube oil filter element (3401544) for DG set 250KVA. |
| 10 | Supply and fixing in repair oil filter element (A041R279) for DG set 250KVA. |
| 11 | Supply and fixing in repair Air filter element (A041R273) for DG set 250KVA. |
| 12 | Supply and fixing foil sealed test strip CC2602B for DG set 250 KVA. |
| 13 | Supply and filling engine oil volvoline premium blue 7800 plus 1/20ltr for DG set 250 KVA. |
| 14 | Taking out and repairing of battery charger 0 to 24 volts suitable for 24 volts with 100 AH battery for DG set 250 KVA and refixing the same after rectification the defect complete all as specified |
| 15 | Supply and fixing in repair fuel filter element (3973232) for DG set 250KVA. |
| 16 | Supply and fixing in repair fuel filter element (3973233) for DG set 250KVA. |
| 17 | Supply and filling of premix coolant inhibitor corrosion 10 ltr complete all as specified. Make Fleetguard |
| 18 | Disconnecting electrically and mechanically outdoor transformers upto 200 KVA capacity carefully, opening of top cover for checking of leakage from LT and HT side, repalcement of old gaskit, testing and refixng the same after rectification the leakage complete all as specified and directed. |
| 19 | Taking out for Complete Rewinding, Drying, Testing & Commissioning of 200 KVA, 11KV/433V, 3 Phase, 50Hz,Delta/Star connected Oil Filled Distribution Transformer including dismantling, core inspection, supply of all new materials, assembly, oil filling, at site and carrying out the following work complete all as specified and directed :- (a) Draining of existing Transformer Oil and safe storage for reuse.(b) Dismantling of all attachment viz breather assembly, conservator, oil temperature gauge, HT/LT bushing etc and keeping aside for reuse..(c) Lifting of Core & Winding assembly from tank. Core opening and winding removal.(d) Core cleaning, Core Loss testing & Core lamination re-stacking with new insulation paper(e) Cleaning of complete transformer tank oil fins, removing of sludge, and making the inside surface of tank dry by blowing of hot air (f) Supply of new Insulating materials: Pressboard, Crepe Paper, Spacers, Blocks, Tapes(g) Coil pressing, HV-LV connection, Tapping arrangement as per original. |
| 20 | M&L for ON load Centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine of 11/0.433 KV transformer installed at various site on plinth/4/6 pole structure of 200 KVA capacity and topping up deficient transformer oil including testing of samples before and after dehydration and filteration complete all as specified and directed.Note :- Deficient quantity of Transformer oil required for top up shall be measured and paid separately under item No 20 here-in -after as supply only. |
| 21 | Supply and filling of transformer oil of approved quality as per IS having dielectric strength of 45-60 KV in 2.5mm gap for filling in transformer or for topping up as required and directed by Dy Project Director |
| 22 | Supply and fixing in repair, Porcelain Transformer bushing on LT ( 440V) side, including brass stems conical bush and gasket after disconnecting indoor/outdoor transformer of capacity upto 200 KVA and connecting electrically and mechanically, testing complete all as specified and directed. |
| 23 | Supplying and fixing in repair, Porcelain Transformer bushing on HT (11 KV) side, including brass stems conical bush and gasket after disconnecting indoor/outdoor transformer of capacity upto 200 KVA and connecting electrically and mechanically, testing complete all as specified and directed. |
| 24 | Supply and fixing in repair Silica Gel Breather assembly and Silica Gel for indoor/outdoor transformers, capacity upto 200 KVA complete all as specified and directed. |
| 25 | Material & Labour for painting of transformer installed on plinth/4/6 pole structures at various site of capacity upto 200 KVA with existing colour, with spraying machine, after cleaning, preparation of outer surface of transformer, including writing of SM No, MES and capacity of transformer complete all as specified and directed. |
| 26 | M&L for re-painting of LT Panels/feeder pillars of approx size 2 to 4 Sqm with 2 coats of super enamel paint over a coat of red-oxide with spary gun including writing of feeder pillar numbers in appropriate size of letters as directed. |
| 27 | All as per item No 25 above but of approx size upto 1.90 Sqm |
| 28 | Material and labour for spreading of stone aggregate of nominal size not more than 25 mm to 40mm surounding area of outdoor transformer manually without damaging any equipments, cable or parts , spreading & levelling of finished gravel uniformaly in layers n. ecc. 15 cm thick watered and rammed to true surface all as specified and directed |
| 29 | Supply and fixing in repair of HT Cable baksa kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 150 Sqmm 3 core. |
| 30 | Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for 25-50 Sqmm x 3.5 core/ 4 core cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed |
| 31 | All as per item No 29 here in before but 70-120 Sqmm x 3.5 core cable |
| 32 | Supplying, Laying, Testing and Connecting in repair XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of 70 Sqmm 3.5 core sizes, laid in trenches or on poles or in protection pipe or under floors / roads complete all as specified and as directed by Dy Project Director.Note- Necessary excavation and earth work, sand cushioning, protective covering and protection pipe shall be measured and paid for separately under respective items of this schedule. |
| 33 | All as per item No 31 here in before but 50 Sq mm 3.5 core cable |
| 34 | All as per item No 31 here in before but 35 Sq mm 3.5 core cable |
| 35 | All as per item No 31 here in before but 25 Sqmm 3.5 core cable |
| 36 | Supplying, Laying, Testing and Commissioning PVC insulated, PVC sheathed, galvanised steel strip or wire armoured cable, with stranded copper conductor, 1100 Volts grade of size 2.5 Sqmm 3 core , laid in trenches or on poles or in protection pipe or under floors / roads complete all as specified and as directed by Dy Project Director.Note - Necessary excavation and earth work, sand cushioning, protective covering and protection pipe shall be measured and paid for separately under respective items of this schedule. |
| 37 | All as per item No 31 here in before but 1.5 Sqmm 3 core |
| 38 | Supply and fixing in repair MCCB 400 amps FP 415 volt with breaking cap 36 KA . Make - L&T/ABB/Schenider |
| 39 | Supply and fixing in repair MCCB 3 phase 415 volt FP 250 amps with breaking cap 36 KA.Make- Havells/ABB/Schenider/L&T |
| 40 | Supply and fixing in repair MCCB 3 phase 415 volt FP 160 amps with breaking cap 36 KA.Make- Havells/ABB/Schenider/L&T |
| 41 | Supply and fixing in repair three Pole MCCB 415 volt of capacity 125 Amp with breaking cap 16KA Make L&T DU125H /Havellls/ABB/Schenider/L&T |
| 42 | Supply and fixing in repair MCB TPN 415 volt of capacity 16-32 Amp with breaking cap 10KA Make- Havells/ABB/Schenider/L&T |
| 43 | Supply and fixing in repair Four Pole MCB/TPN 415 volt of capacity 40-100 Amp with breaking cap 10KA Make- Havells/ABB/Schenider/L&T |
| 44 | Supply and fixing in repair MCB TP 415 volt of capacity 25-63 Amp with breaking cap 10KA Make- Havells/ABB/Schenider/L&T |
| 45 | Supplying and fixing 40 amp rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make- Havells/ABB/Schenider/L&T |
| 46 | Supply and fixing in repair MCB DP 10 Amps with breaking cap 10KA Make- Havells/ABB/Schenider/L&T |
| 47 | Supply and fixing in repair MCB DP 20 Amps with breaking cap 10KA Make- Havells/ABB/Schenider/L&T |
| 48 | Supply and fixing in repair MCB SP 6 amps with breaking cap 10KA Make- Havells/ABB/Schenider/L&T |
| 49 | Supply and fixing in repair 3 phase control Panel Incomer with MCBs and Neutral Link complete all as specified |
| 50 | Supply and fixing in repair of resin cast/tape wound CTs of ratio 200/5A to 600/5A for APFC and electric/fountain panels for measurement and PF correction complete with mounting hardware, wiring and testing complete all as specified |
| 51 | Supply and fixing in repair of 3 Pole power contactors 240V AC MNX-12 type mounted on any type control/feeder panel Make L&T or equivalent approved make. |
| 52 | Supply and fixing in repair of 3 Pole power contactors 240V AC MNX-18 type mounted on any type control/feeder panel Make L&T or equivalent approved make. |
| 53 | Supply and fixing in repair of 3 Pole power contactors 240V AC MO C5- C20 type mounted on any type control/feeder panel Make L&T or equivalent approved make. |
| 54 | Supply and fixing in repair of 3 Pole power contactors for capacitor switching UA16-30-10RA 220-230V 50Hz/230-240V 60Hz type mounted on any type control/feeder panel Make ABB or equivalent approved make. |
| 55 | Supply and fixing in repair of 4 Pole front mounted auxiliary contact block CA5-22E type mounted on any type control/feeder panel Make ABB or equivalent approved make. |
| 56 | Supply and fixing in repair supernova relay range 6.3 -10A complete all as specified. Make L&T or equivalent approved make. |
| 57 | Supply and fixing in repair Astronomical time switch complete all as specified. Make L&T cat No T2DDT7 or equivalent approved make. |
| 58 | Supply and fixing in repair fiber Auto/manual selector switch complete all as specified. Make L&T or equivalent approved make. |
| 59 | Supply and fixing in repair RYB phase indicating lamps complete all as specified. Make AE/L&T/Legrand |
| 60 | Supply and fixing in repair analog volt meter 0-500 volt complete all as specified.. Make AE/L&T/Legrand |
| 61 | Supply and fixing in repair analog Ampere meter 0-500 volt complete all as specified.. Make AE/L&T/Legrand |
| 62 | Supply and fixing in repair Stainless steel light stand 1 way 25 mm in SS 304 for submersible LED ight fitting complete all as specified and directed by Dy Project Director. |
| 63 | Supply and fixing in repair Stainless steel light stand 1 way 40 mm in SS 304 for submersible LED ight fitting complete all as specified and directed . |
| 64 | Supply and fixing in repair 2x1.5 Sqmm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 65 | Supply and fixing in repair 2x2.5 Sqmm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 66 | Supplying and fixing in repair 6 Amp one way modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 67 | Supplying and fixing in repair Socket, 6A - 2/3 pin combined 2 module on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 68 | Supplying and fixing in repair Modular switch 1 way 16A,1 module on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 69 | Supplying and fixing in repair Socket 6A/16A - 2/3 pin combined 2 module on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 70 | Supplying and fixing in repair 3 Module base & cover plate on existing modular metal boxes etc. as required. |
| 71 | Supplying and fixing in repair 6 Module base & cover plate on existing modular metal boxes etc. as required. |
| 72 | supply and fixing in repair Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal |
| 73 | supply and fixing in repair Switch socket combination 2 in 1, 3 pin,6 Amp flush type universal Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysSep 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender