Tender For Addn/Altn Including Sunken Treatment To Bathroom Of Bldg No P-1015 And P-1016 Of 83 Armd Regt Under Ge Hisar At Mil Stn Hisar
Tender Value
34 Lakhs
Estimated cost
Bid Submission
16 Sep 2026
1 days left
EMD
68000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hisar → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addn/Altn Including Sunken Treatment To Bathroom Of Bldg No P-1015 And P-1016 Of 83 Armd Regt Under Ge Hisar At Mil Stn Hisar
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling roof tiles, single layer on roofs complete all as speified & directed. |
| 2 | Demolition of mud in roofs, any thicknes, including plastering and leeping (whether full thickness removed or only or part thereof) complete all as speified & directed. |
| 3 | M&L for PCC 1:2:4 (Type B1 using 20 mm graded aggregate) levelling course average thick 40 mm, to match the undulations of roof complete all as specified and directed. |
| 4 | M&L 10 mm thick cement screed in CM 1:3 mixed with water proofing compound of approved make over RCC roof slab/concrete surface/brick tiles and vertical surface, finished even and smooth by using steel trowel complete all as specified and directed. (Note :- WPC shall be measured and paid separately.) |
| 5 | M&L for APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150 gms /sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 ltr/Sqm by forced application method complete all as specified and directed and described as under. Four course roof treatment consists of as under :- (a) Applying one coat of bituminous primer conforming to IS-3384 @ 0.30 Ltr per sqm.(b) Laying of APP based membrane as specified thickness and weight.(c) Applying one coat of bitumin grade 85/25 @ 1.2 Kg/Sqm.(d) Applying two coat of aluminium paint @ 200ml/sqm.Note :- APP membrane work shall be excuted by athorised applicator of APP as approved by GE. |
| 6 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid and beeded and pointed any cement mortar complete all as specified and directed. |
| 7 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20 mm thick screed beed in CM 1:6 complete all as specified and directed. |
| 8 | M&L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed over and including provision of 10 mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 9 | Taking up or down 15mm bore steel / composite / UPVC tubing and connection from any position concealed / exposed including cleaning for refixing or removal to store complete all as specified and directed. |
| 10 | S&F 15 mm dia steel water GI tube medium grade with all fittings / connections & MS clamps / clips and necessary screwing as reqd and fixed with or without concealed to walls & surface of roof slab with and including making good to required surfaces by using white cement complete all as specified and directed. |
| 11 | Re-fixing old 15mm dia steel water GI tube medium grade with all fittings / connections & MS clamps / clips and necessary screwing as reqd in new or old position and fixed with or without concealed to walls, ceilings or laid in floors complete all as specified and directed. |
| 12 | Supply & Laying of 3-layer PP-R Polypropylene random copolymer) concealed pipes 20mm outer dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etccomplete all as specified and directed. |
| 13 | Taking up or down 20mm bore steel / composite / UPVC tubing and connection from any position concealed / exposed including cleaning for refixing or removal to store complete all as specified and directed. |
| 14 | S&F 20 mm dia steel water GI tube medium grade with all fittings / connections & MS clamps / clips and necessary screwing as reqd and fixed with or without concealed to walls, ceilings or laid in floors complete all as specified and directed. |
| 15 | S&F in repair CP angle valves (chromium plated fancy type) 15 mm dia, cast copper alloy, screwed down, high pressure with crutch screwed both end for iron pipe or for unions complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F 15 mm dia PVC connections, 450 mm long with PTMT nuts of suitable size at two end complete all as specified and directed. |
| 17 | S&F in repair 15 mm bib tap ( fancy type) long body, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 18 | S&F brass chromium plated shower roses of size 125mm with or without swivel joints, any size, including shower arm 15mm size, 195mm long bend of 45degree with flange of CP fixing to steel pipe or union complete all as specified and directed. |
| 19 | S&F in repair pillar cock, swan neck 15mm dia mixture for hot and cold, CP fency type long screwd shank complete all as specified and directed. |
| 20 | S&F Wash hand basin, Vitreous China ovel shaped, first quality, white colour, of size 560x430x195mm under counter fixed in granite with sutaible arrangement with 750mm long PVC waste pipe 32mm dia, CP waste coupling with long screwed shanks and fly nuts complete all as specified and directed. |
| 21 | S&F in repair vitreous China, squatting pan, Orissa Pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) with PTMT trap of suitable size (P or S type) including connection to trap and to flushing pipe, anti syphonic pipe etc complete including provision of cement concrete bedding & making good to floor complete all as specified and directed. |
| 22 | S&F in repairs vitreous china urinal, Half stall type white, with grating and union etc complete all as specified and directed. |
| 23 | S&F brass chromium plated urinal spreader with brass CP connector complete all as specified and directed. |
| 24 | S&F in repairs for brass chromimum plated two way bib cock fancy type, 15mm bore ( min Wt. 550 grams) of approved make by EIC/ GE etc.complete all as specifed and as directed. |
| 25 | S&F in Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 26 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white with P or S trap with and including plastic water closet seat cover , connection to trap, flushing pipe & anti -syphonage pipe etc including necessary materials for fittings & making good to floor complete all as specified and directed by Engr-in-Charge. |
| 27 | S&F in repairs 10 Ltr capacity PVC valveless syphonic action type flushing cistern low level white, with inlet, ball valve, float and handle including PVC flush pipe and brackets complete fixed in wall and floor to trap of WC as reqd complete all as specified and directed. |
| 28 | Re-fixing old serviceable 15mm bore CP bib tap/ angle cock/ pillar tap, concealed stop cock, CP mixture valve, shower with all fittings after repair by suitable size of brass head and other materials as required in new or old position and fixed with or without concealed to walls with and including making good disturbed surfaces by using white cement and cement mortar (1:4) mixed with pigment to match the existing surface complete to the entire satisfaction of Engineer-in-charge. |
| 29 | S&F in repair single/multi PVC (SWR) floor trap 75mm dia, palin with grating including joining to waster pipe, fixed in cement concrete type B-1 (1:2:4) using 20mm graded broken stone aggregate co,mplete all as specified and directed. |
| 30 | M&L Granite black colour dark shade, 18 to 20 mm thick machine cut laid over cement screed as in floor and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the granite stone including cutting and polishing with and including 15mm thick screed bed or bedding in cement mortar 1:6 complete all as specified and directed. |
| 31 | M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. |
| 32 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 33 | M&L non skid ceramic tiles coloured pattern as required of 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:4) compete all as specified and directed. |
| 34 | M&L glazed ceramic coloured, designer & pattern (dark & light shade combination) tiles in 450 x 300 x 7 to 8 mm thick on vertical surfaces such as dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match over with and including 10mm thick backing coat in CM 1:3 and d complete all as specified and directed. |
| 35 | M&L for PCC 1:2:4 type B1 40mm thick (using 20mm graded aggregate) as in levelling course to match the undulations of floor complete all as specified and directed. |
| 36 | Taking down chowkats or frames with shutter (without taking off shutter from the frames) n. exc 1.50 Sqm each complete all as specified and directed. |
| 37 | S&F factory made mild steel windows (Box Type ) with side hung shutters including glazing bars to receive glass, dovetailed or welded with and including necessary welding, reveting, tower bolt, hanlde, holdfast, hinges and steel peg stay as per Drg No. CEJZ/TD-2013/01 sheet (1/3, 2/3, 3/3) complete all as specified and directed. |
| 38 | S&F factory made mild steel windows (Box Type ) with side hung shutters without glazing bars but including sash bars to receive wire gauge, dovetailed or welded with and including necessary welding, reveting, tower bolt, hanlde, holdfast, hinges and steel peg stay as per Drg No. CEJZ/TD-2013/01 sheet (1/3, 2/3, 3/3) complete all as specified and directed. |
| 39 | S&F in replacement aluminium anodized powder coated ventilator using rectangular tube of size 63.5 x 25 x 1.5mm with 4mm thick design glass louvers etc., complete all as specified and directed. |
| 40 | S&F Factory made single extruded WPC (WoodPolymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 41 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 42 | Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm n.exc 4.00 Sqm each complete all as specified and directed. |
| 43 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. specification & drawing complete all as specified and directed. |
| 44 | M&L 30mm thick factor made 2nd class hard wood glazed and skelton shutters open rebated and prepared to receie glass guaze etc. edges of framing plain chamered or rounded fitted with cut and mitered beads for securing glass etc. all as specified and directed. |
| 45 | S&F 30mm flush door shutters, soild core construction, with block board core and plywood face panels, commercial type both sides complete all as specified and directed. |
| 46 | S&F stainless steel butt hinges medium weight of size 100 mm fixed with stainless screws complete all as specified and directed. |
| 47 | S&F 200mm size aluminium anodised, barrel tower bolt of extruded section complete all as specified and directed. |
| 48 | S&F extruded aluminium alloy handles 150 mm long fabricated type anodised complete all as specified and directed. |
| 49 | S&F in repair 250 mm long aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed by Engr-in-Charge. |
| 50 | S&F in repair 140 mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door complete all as specified and directed. |
| 51 | M&L preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 52 | S&F in stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engr-in-Charge. |
| 53 | Taking down shutter of any description area exc. 1 Sqm and n.exc. 2 Sqm complete all a specified and diredted. |
| 54 | Re-fixing of shutter after repair of any description of area exc 1.00 sqm but not exc 2.00 Sqm complete all as specified and directed. |
| 55 | S&F plain glass 4.00 mm thick, pin head type and glazing with oil putty & necessary screwing / cliping in squares/rectangle exc 0.5 Sqm in each pane complete all as specified and as directed and directed. |
| 56 | Demolition of brickwork or stone/ boulder masonry, pcc block masonary built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc. complete all as specified and as directed. |
| 57 | M&L for old size bricks with fly ash bricks straight or curved on plan exc. 6m mean radius and setting in cement mortar 1:6 etc. complete all as specified as directed. |
| 58 | Taking down cement plaster of any description upto three storeys including necessary scaffoldings including raking out joints, hacking for key, scrubbing down with water etc. from wall & ceiling surfaces complete all as specified and directed. |
| 59 | M&L 10mm thick rendering on fair faces of brick/conc surfaces in CM 1:4 finished even & fair complete all as specified and directed. |
| 60 | M&L for preparation of newly plastered surfaces of walls and applying two coat of distemper oil emulsion over a coat of primer and avg 3mm wall care putty complete all as specified and directed. |
| 61 | M&L 5mm thick rendering on fair faces of conc surfaces of ceiling in CM 1:3 finished even & smooth without using extra cement complete all as specified and directed. |
| 62 | M&L for preparation of new plastered surfaces of wall/ceiling and applying three coat of white wash complete all as specified and directed. |
| 63 | M&L 15 mm thick rendering on fair faces of brick work or concrete surfaces intwo coats (first coat 10 mm thick incm 1:4 and second coat 5 mm thick cement mortar 1:4, using liqud water proofing compound, finished fair & even w/o using extra cement at any height including all necessary scafolding etc. complete as directed.(Note - WPC shall be measured and paid seaperatly.) |
| 64 | Spply only liquid water proofing compound complete all as specified and directed. |
| 65 | M&L for preperation of newly plastered surface applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces at any height including necessary scafolding etc complete all as specified and directed. |
| 66 | Material & Labour for complete removel of existing paint from wall and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10bsqm over 2 mm putty at any height including necessary scafolding etc complete all as specified and directed. |
| 67 | M&L for preparing old plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer and 2mm wall putty of same make with and including complete removal of existing treatment of any layer of wall by sanding with internal dust extraction system for clean environment and complete all as specified and directed. |
| 68 | M&L preparing old plastered or unplastered surfaces of walls and applying two coats of white wash on old decorated surface with and including complete removal of existing treatment of any layer of wall complete all as specified and directed. |
| 69 | M&L for preparing old plastered or unplastered surfaces of ceiling and applying two coats of white wash on old decorated surface with and including complete removal of existing treatment of any layer of ceiling surfaces complete all as specified and directed. |
| 70 | S&F 600 x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 71 | S&F chromium plated Tubular towel rail, 18/20mm dia, D type, 60cm long between flanges, fixed withl screws complete all as specified and directed. |
| 72 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed. |
| 73 | S&F 110 mm bore PVC (SWR) pipes 3mm thick SN-4, single socketed, in any length with rubber ring joints, fixed to walls & floors with necessary MS clamps complete all as specified and directed. |
| 74 | S&F 75 mm bore PVC (SWR) pipes 3mm thick SN-4, single socketed, in any length with rubber ring joints, fixed to walls & floors with necessary MS clamps complete all as specified and directed. |
| 75 | S&F 110 mm PVC (SWR) bends (with acess door) any radius complete all as specified and directed. |
| 76 | S&F 75 mm PVC (SWR) bends (with access door) any radius complete all as specified and directed. |
| 77 | S&F 110mm PVC (SWR) junction single,(Single T) equal or unequal provided complete all as specified and directed. |
| 78 | S&F 75mm PVC (SWR) junction single,(Single T) equal or unequal provided complete all as specified and directed. |
| 79 | S&F 75mm PVC (SWR) branch piece, single (single Y) equal or unequal provided complete all as specified and directed. |
| 80 | S&F 110mm PVC (SWR) branch piece, single (single Y) equal or unequal provided complete all as specified and directed. |
| 81 | M&L for preparation of old painted steel or iron surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 82 | M&L preparation of old wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 83 | S&F curtain rod, 20mm dia, CP with and including fency type CP bracket 2 Nos of each opening and side stopper fency type powder coated of required shape and size 2 Nos of each opening complete all as specified and directed. |
| 84 | Demolition and breaking up drain pipes (salt glazed ware or RCC or PVC) set in cement mortar 200mm dia complete all as specified and directed. |
| 85 | M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 200mm dia pipe complete all as specified and directed. |
| 86 | S&F high-stiffness (8 kN/m²) underground drainage/sewer pipe, typically Double Wall Corrugated (DWC) HDPE or smooth PVC, designed for heavy loads under roads and in urban areas, featuring high crush resistance, durability, and flow efficiency, often meeting standards like IS 16098 and available in 200mm dia with secure joint systems including all fittings complete all as specified and directed. |
| 87 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 88 | M&L TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips confirming to grade of steel Fe 500D complete all as specified and directed. |
| 89 | M&L TMT bars 5mm dia and over up to and including 10 mm dia cut to length bend to shape required including cranking, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia as in stirrups, spacers and binders complete all as specificed and as directed. |
| 90 | Providing and fixing water tight centering & shuttering and Scaffolding including bolting, strutting, propping etc. including removal of form work from column, beam , slab etc. complete as per site requirement and directions of Engineer-in-charge. |
| 91 | Supply and apply a ready to use non shrink, cementitious free flow micro-concrete (<100 mm) using Product: SikaRep® Microcrete-4 + adequate coarse aggregate, Yield: approx 17 Ltr/bag (30 Kg) (depending on the size and quantity of coarse aggregate added), Product : SikaRep® Microcrete-4 or equivalent make in Fosroc / Thermax as approved by GE, Product requirements: compressive strength > 60 N/Sqmm (28 days) according to ASTM C 1107-99 complete all as specified and directed. |
| 92 | M&L for chipping of loose/ damaged /cracked / previously repaired / delaminated or weak concrete by chieseling to expose the sound core concrete where ever required and to expose rusted reinforcement upto depth n.exc 50mm and disposal of rubbish off the premises to a distance not exc 50 mtrs including cleaning of reinforced concrete surface by air compressor complete all as specified and directed. |
| 93 | Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using product: Rustoff-100 of Sika or equivalent make in Fosroc/ Thermax as approved by GE, with density 1.01 Kg/ltr at 30 degree celsius and consumption : 0.2 Kg/Sqm/coat complete all as specified and directed.Note : The mtrl to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar. |
| 94 | Supply and apply a cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and Product requirements: carbonation resistance: 2 mm of SikaTop Armatec®-108 of Sika or equivalent make in Fosroc / Thermax as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N / Sqmm according to ASTM C 882-78 complete all as specified and directed.Note: The mtrl to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar. |
| 95 | M&L for Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer's specification including prepartaion of surface throughly and cleaning complete where ever required with using Product: Sikadur®-32 LP of Sika or equivalent in Fosroc / Thermax as approved by GE with Consumption: 0.4 kg/Sqm and Product requirements: Complies with ASTM C 881-78, Type II Grade 2 Class B+C complete all as specified and directed. |
| 96 | M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete surface in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions complete all as specified and directed. |
| 97 | S&F welded steel wire fabric n exc 4 Kg/Sqm fixed with necessary nails/fasteners and mild steel wire not less than 0.9 mm dia etc at wall/floor/slab etc complete all as specified and directed. |
| 98 | M&L for treatment of sunken floor slab comprising of the following specifications given below with and including demolition of sunken floors complete all as specified and directed :-(i) Cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. S&F of 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout. |
| 99 | (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with and including integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc / Thremax as approved by GE @ 0.2% by wt of cement consumed including filling it with water to check dampness and seepage and where dampness / seepage is noticed, nozzles shall be fixed and grouting carried out.(iii) All junctions points of side walls where CI/GI/PVC pipes are passing through shall be sealed with epoxy putty Sikaguard 694 F(I) or equivalent make in Fosroc / Thremax as approved by GE.(iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. |
| 100 | (v) Applying two coats of polymer modified cementious water proof coating with Sika Topseal 107 or or equivalent make in Fosroc / Thermax as approved by GE in two coats @ 3kg/sqm to sanwiched with glass fibre reinforcemnt: Sika Fab-1 or or equivalent make in Fosroc / Thermax as approved by GE over base coat as per mnaufacturer's instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion. |
| 101 | (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound SIKA plastocreat plus or equivalent make in Fosroc / Thermax as approved by GE @ 0.2% by wt of cement consumed as per manufacturer's specification including rounding of corners and injuctions sloping towards spout.(vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint. |
| 102 | (viii) The sunken floor shall be filled with lean concrete 1:4:8. Notes :- (i) Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of WPT chemicals. Cost of testing and all M&L is included in the rates quoted above.(ii) For payment purpose, the plan area of sunken floor shall be measured and paid. |
| 103 | S&F for Pipe Supporting Clamping for Single pipe of dia 110 mm (4\\") down take pipe fixing done with Clamping System consists of Rain Water Bracket Set with Pipe Support Channel + U Bolt Rubber Sleeve mounted System running vertically with wall distance 75 mm (3\\"): Pipe Support Clamping shall be made up of : 1. Rain Water Bracket Set with pipe support channel for 110 mm pipe having Wall Distance 75 mm (3\\") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROPD) Steel (IS:1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanised + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 2000 hrs. 2. U bolt Rubber Sleeve mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Rain Water Bracket Set with pipe support channel for 110 mm pipe; Wall distance 75 mm (3\\") - 1 Nos. ; 2. U bolt Rubber Sleeve mounted for 4\\" (110 mm) PVC Pipe Dia. - 1 No.; and 3. Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2\\") - 2 nos. Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in Chief Engineer Jodhpur Zone Technical Drawing (TD) of Factory Made Pipe Supporting System : CEJZ/TD/102. Make: Shaivi or equivalent as approved by GE. |
| 104 | S & F for Pipe Supporting Clamping for Single pipe of dia 75 mm (3\\") down take pipe fixing done with Clamping System consists of Rain Water Bracket Set with Pipe Support Channel + U Bolt Rubber Sleeve mounted System running vertically with wall distance 75 mm (3\\"): Pipe Support Clamping made of: 1. Rain Water Bracket Set with pipe support channel for 75 mm (3\\") Pipe Dia. having Wall Distance 75 mm (3\\") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 2000 hrs. 2. U bolt Rubber Sleeve mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Rain Water Bracket Set with pipe support channel for 75 mm pipe; Wall distance 75 mm (3\\") - 1 Nos. ; 2. U bolt Rubber Sleeve mounted for 75 mm (3\\") Pipe Dia. - 1 No.; and 3. Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2\\") - 1 nos. Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in Chief Engineer Jodhpur Zone Technical Drawing (TD) of Factory Made Pipe Supporting System : CEJZ/TD/102. Make: Shaivi or equivalent as approved by GE. |
| 105 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out soft and loose soil and returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 106 | PCC 1:3:6 Type C-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 107 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction but welded tubes conforming to IS- 1161-1979 grade St-240 including errection and fabrication complete all as specified and directed. |
| 108 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 109 | M&L painting, two coats with synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description over 10cm width or girth including preparation of surfaces and priming with red oxide complete all as specified and directed. |
| 110 | Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed. |
| 111 | M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including concealed PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc including modular press steel with cover plate and frame, complete, all as specified & directed. |
| 112 | All as per item No 107 (here-in-before) but one Fan/exhaust fan point controlled by one Number one way switch complete all as specified and directed. |
| 113 | All as per item No. 107 (here-in-before) but for one 6 Amp socket outlet on independent board controlled by one Number one way switch on independent board. |
| 114 | All as per srl item No. 107 (here-in-before) but for 16 Amp socket out let by using 2.50 sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed. |
| 115 | S&F modular type switch piano, flush type, single pole, one way, 6 Amp, 230 Volts all as specified & directed. |
| 116 | S&F modular type switch piano flush type, single pole, one way, 16 Amp, 230 Volts complete all as specified and directed. |
| 117 | S&F modular type socket outlet multipurpose 3 Pin 6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed. |
| 118 | S&F modular type socket outlet multipurpose 3 Pin 16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed. |
| 119 | S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed. |
| 120 | S&F LED light fitting 10 W, regal batten for LED including ultra bright glass LED Tubelight with very high efficacy, single / double side connection all as specified and directed. |
| 121 | S&F in repair of MCB single pole, 240 volts, 10 Amps to 32 Amp breaking capacity 10KA complete all as specified and directed. |
| 122 | S&F in repair of MCB SPN, 240 Volts, 40-63 Amps breaking capacity 10 KA complete all as specified and directed. |
| 123 | S&F in repair of sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 having door earthing complete all as specified and directed. |
| 124 | S&F sub main wiring using two runs of single core 6 sqmm FRLS PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing PVC conduit of dia note more than 25mm alonwith accessories like bends, tee, etc. and connecting to earth dolly and including one run of 6.0 sqmm earth wire, PVC insulated & unsheathed complete all as specified and directed.Note:- Two runs main wire, one run of earth wire and one run of PVC conduit shall be measured and paid as one unit. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 daySep 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender