Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #57244446

Tender For Comprehensive Maintenance B/R And E/M Works Of Certain Md Accn In Zone ‘C Area At Nda Khadakwasla

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
34.98 Lakhs
Estimated cost
Bid Submission
16 Sep 2026
17 days left
EMD
69960
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Comprehensive Maintenance B/R And E/M Works Of Certain Md Accn In Zone ‘C Area At Nda Khadakwasla

BOQ

Name of Work:- COMPREHENSIVE MAINT B/R AND E/M WORKS OF CERTAIN MD ACCN IN ZONE ‘C AREA AT NDA KHADAKWASLA
Sl. No. Item Description
1M&L for precast cement concrete block masonry with solid blocks exc 10cm thick,1:3:6 type C-1 (using 20 mm graded stone aggregate), of size 300mm x 100mm x 200mm and setting in cement mortar 1:4, complete all as specified and directed.
2M & L for providing Reinforced cement concrete (1:2:4) type B-1 Nominal Mix using 20 mm graded stone aggregate as in slab supported on walls ,beams and columns in floors,roofs,landings, kitchen slabs etc complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately.)
3Cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, lintels, shelves etc, and cutting chases for concealed water tubing or concealed conduit wiring etc, and making good on brick walls, cutting not exc. 10 cm in girth complete all as specified and directed .
4M&L for Walling of squared rubble, regular coursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
5M&L 16-18 mm thick granite (Z Black) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms, counter basins and like laid over and including screed bed 15 mm thick in CM 1:4 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and complete all as specified and directed. (Note:- Granite to be used in treads shall be one piece with nosing at front and cutting two grooves along with nosing. Exposed edges to be made half round. Colour shall be of Lakha red, flamed granite or telephonic black as approved.)
6M&L for rough finished flat formwork to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exc. 200 mm thick (horizontal or sloping) work as rough finished surfaces of concrete complete all as specified and directed.
7M&L for rough finished flat Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls floor and roofs not exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or slopping and similar work work exc 10cm but n exc 20cm Wide rough finished surface of concrete complete all as specified and directed.
8S & F of 2nd class Hard wood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails sectional area exc 13 but not exc. 25 sqcm complete all as specified and directed.
9S&F 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints including making rebate for fixing second shutter as per site requirement complete all as specified and directed.
10S & F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (with sash bars), edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass/gauze etc. conforming to IS 1003 Pt-I & II : size of members of shutters as specified in SSR Part-1, section 8, clause 8.24 (b) kiln seasoned and chemically pressure treated (Size of stiles 75 mm wide) complete all as specified and directed.
11S & F 30 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers), edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc. size of members of shutters as specified in SSR Part-1, section 8, clause 8.24 (a) kiln seasoned and chemically pressure treated complete all as specified and directed.
12S&F 35 mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
13Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
14Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
15Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each complete all as specified and directed.
16S & F 30 mm thick (style thickness) factory made solid panel PVC shutter consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheets beading and joined together with solvent cement as per specification and drawing given on MES schedule Part – II (2020) complete all as specified and directed.
17S & F factory made Solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain coloured PVC sheet reinforced with mild steel square tube as per specification and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
18S&F 150 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
19S&F 75 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
20Supply and fix 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed.
21S & F 75 mm long medium weight, cold rolled mild steel Butt hinges with screws complete all as specified and directed.
22S & F 100 mm long medium weight, cold rolled mild steel Butt hinges with screws complete all as specified and directed.
23S & F Continuous (Piano) hinges, Brass, bright finished or electro galvanized, width of flaps (When open) 30 mm complete all as specified and directed.
24S & F in repairs 300 mm long ordinary rat tail pattern springs including roller and roller plate complete all as specified and directed.
25S&F 100 mm Aluminium handles cast type, anodised and fixed complete all as specified and directed.
26S & F 125 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
27S&F in repair stainless steel towel rail ‘D’ type 600 mm long between flanges of brass chromium plated fixed with and including chromium plated brass screws and wooden / plastic cleat complete all as specified and directed.
28S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed.
29S&F in repairs Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed.
30M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
31M&L anodised Aluminium frame for door, window, Cup board and ventilator with one or more rebates including jointing cleats for fixing etc complete all as specified and directed.
32S&F Powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
33S&F for Aluminium powder coated door shutters, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges anodised alumnium snap beading, screws etc complete all as specified and directed.
34M & L in repairs 25 mm thick Block boards, grade 2 quality, interior grade, decorative type, with decorative face veneer on both face fixed with screws to cupboard shutters and shelves complete all as specified and directed.
35M&L for rough dressed sahabad stone slab flooring 30 mm thick, jointed in cement mortar 20mm thick 1:6 and pointed in cement mortar 1:3 complete all as specified and directed.
36M&L machine cut kota stone slab flooring 20-25 mm (minimum) thick as in flooring laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab and including rubbing and mirror polishing and laid over 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
37M&L 75 mm thick, PCC 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) finished even and smooth without using extra cement as in plinth protection/path laid in alternate panels not more than 3 mtr in length, laid to slope 1:30 including forming joints 10 mm wide and upto full depth of PCC and filled with bituminous mastic 1:3 ( one part bitumen 85/25 grade and three part sand)to be given at every 3M interval and corners of buildings complete all as specified and directed.
38M&L 75 mm thick, PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub floor, sub base of floor, paving, path etc including formwork complete all as specified and directed.
39M&L for 25 mm thick PCC 1:2:4 type B1 (using 20 graded stone aggregate) in floorings including finishing the surface even and fair to receive floor finishes complete all as specified and directed.
40M&L Coloured glazed ceramic tiles 300x200x7mm / 300x 450x 7 mm thick in vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick backing with cm 1:4 complete all as specified and directed.
41M&L Joint free Non Skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc.0.06 sqm but n. Exc. 0.11 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed 15 mm thick in CM 1:6 finish even and rough complete all as specified and directed.
42M&L joint free Non Skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed 15 mm thick in CM 1:6 finish even and rough complete all as specified and directed.
43M&L Joint free Non Skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm, as in skirting/dado on vertical surfaces over etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed 10 mm thick in CM 1:4 complete all as specified and directed.
44M&L joint free Non Skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.18 sqm but n. exc. 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed 15 mm in cement mortar 1:6 complete all as specified and directed.
45M&L joint free Non Skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.18 sqm but n. Exc. 0.38 sqm, as in skirting/dado on vertical surfaces over etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including backing 10 mm in cement mortar 1:4 complete all as specified and directed.
46Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
47M&L machine cut cudappah 20-25mm thick over cement screed base, laid set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
48M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished the surface even and smooth without using extra cement complete all as specified and directed.
49M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth complete all as specified and directed.
50M&L for rendering 10 mm thick in CM 1:3 on ceiling finished even and smooth without using extra cement complete all as specified and directed.
51Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
52M & L for painting the new WALL surface complete all as specified and directed as follows :- (a) Surface Preparation- Preparation of newly plastered or previously untreated surfaces of walls (b) Putty application- Applying a thin layer of wall care putty to obtain smooth and even finish after rubbing with emery paper (c) Priming surface- Applying one coat of alkali resistant primer (d) Painting- Applying two coats of oil bound distemper.
53M & L for painting the NEW CEILING surface complete all as specified and directed as follows :- (a) Surface Preparation- Preparation of newly plastered or previously untreated surfaces of ceiling. (b) Putty application- Applying a thin layer of wall care putty and achieve smooth surface after sanding. (c) Priming surface- Applying one coat of alkali resistant primer (d) Painting- Applying two coats of oil bound distemper.
54M & L for painting the new wall surface white or tinted including scaffolding arrangement, trestles and ladders etc complete all as specified and directed as follows :- (a) Surface Preparation- Preparation of newly plastered or previously untreated surfaces of walls (b) Putty application- NIL (c) Priming surface- NIL (d) Painting- Applying two coats of cement base paint.
55M & L for painting the old wall surface complete all as specified and directed as follows :- (a) Surface Preparation- Preparation of old plastered or previously untreated surfaces of walls (b) Putty application- NIL (c) Priming surface- NIL (d) Painting- Applying one coats of cement base paint.
56M & L for painting the old wall surface complete all as specified and directed as follows :- (a) Surface Preparation- Complete removal of existing old plastered or previously untreated surfaces of wall. (b) Putty application- Applying a thin layer of wall care putty to achieve smooth surface after sanding. (c) Priming surface- NIL (d) Painting- Applying two coats of 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work.
57M & L for painting the old ceiling surface complete all as specified and directed as follows :- (a) Surface Preparation- Complete removal of existing old plastered or previously untreated surfaces of ceiling. (b) Putty application- Applying a thin layer of wall care putty to achieve smooth surface after sanding. (c) Priming surface- NIL (d) Painting- Applying two coats of 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work.
58Raking out joints/ pointing to squared rubble masonry, coursed or uncoursed built in cement mortar complete all as specified and directed.
59M&L for raised pointing to random or polygonal rubble masonry, uncoursed brought upto courses in cement mortar 1:4 complete all as specified and directed.
60M&L for flush pointing to squared rubble masonry, coursed or uncoursed brought upto courses in cement mortar 1:4 complete all as specified and directed.
61M&L for providing a thin layer of water proof cement base putty over prepared old plastered / old painted wall surface to prepare the surface even and smooth upto desired finishes by manually / mechanical means etc complete all as specified and directed.
62M&L for providing a thin layer of water proof cement base putty over prepared old plastered / old painted ceiling surface to prepare the surface even and smooth upto desired finishes by manually / mechanical means etc complete all as specified and directed.
63S & F Sheet glass 3.0 mm thick, ordinary quality and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane glazed with putty or fixed with beads complete all as specified and directed.
64S & F 4 mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed .
65Hacking out old broken glass (any thickness, size, quality or description) from steel/wooden frames or stones, concrete or brick surrounds glazed with oil putty or fixed with beads complete all as specified and directed.
66M & L for painting the new wood surface complete all as specified and directed as follows :- (a) Surface preparation- Preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth (b) Priming surface- Applying one coat of pink primer (c) Painting- Applying two coat of synthetic enamel paint.
67M & L for painting the old wooden surface complete all as specified and directed as follows :- (a) Surface preparation- Preparation of old wooden surfaces of any description, not otherwise described over 10 cm width or girth (b) Priming surface- NIL (c) Painting- Applying one coats of synthetic enamel paint.
68M & L for painting the old steel surface complete all as specified and directed as follows :- (a) Surface preparation- Preparation of old steel surfaces of any description, not otherwise described over 10 cm width or girth (b) Priming surface- NIL (c) Painting- Applying one coats of synthetic enamel paint.
69Taking up or down 15 mm dia steel tubing and connections, complete all as specified and directed.
70Taking up or down 20 mm bore steel tubing and connections, complete all as specified and directed.
71S&F 15 mm bore galvanised steel water tubing medium grade and including necessary GI fitting (such as bends, elbows, tees etc. and fixed to wall / ceiling or laid in / on floor with clip, hooks and saddles complete all as specified and directed.
72S&F 20 mm bore galvanised steel water tubing medium grade and including necessary GI fitting (such as bends, elbows, tees etc. and fixed to wall / ceiling or laid in / on floor with clip, hooks and saddles complete all as specified and directed.
73Supply and laying of CPVC Pipes 16 mm outer dia SDR-11 & plain CPVC SDR 11 fittings (incl all fittings like brass FTA, MTA, elbow, Tee, union, adaptor etc) (concealed type) on wall /ceiling or laying in floor complete all as specified and as directed
74Supply and laying of CPVC Pipes 20 mm outer dia SDR-11 & plain CPVC SDR 11 fittings (incl all fittings like brass FTA, MTA, elbow, Tee, union, adaptor etc) (concealed type) on wall /ceiling or laying in floor complete all as specified and as directed
75S & F in repair 15 mm bore bib tap chromium plated, fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
76S&F in repairs pillar tap 15 mm bore,fancy type, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without lettered “hot\\" or “cold” with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
77S&F in repairs Sink mixer, brass, chromium plated, for mixing hot and cold water, with 450 mm Long Braided Hoses, screwed down for 15 mm bore pipe complete all as specified and directed.
78S & F in repair 15 mm bore stop valve / angle valve fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions including CP nipple and socket and wall flange complete all as specified and directed. Make Cera F8040204 or equivalent
79S & F in repair 15 mm bore stop valve, fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed including dismantling of old one complete all as specified and directed.
80S&F in repair Bib tap 15mm dia standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms/20mm-125gms) complete all as specified and directed.
81S& F in repair Stop valve 15mm dia of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/ 20mm- 92gms) complete all as specified and directed.
82S & F in repairs 32 / 40mm Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms / 40mm-60gms) complete all as specified and directed.
83S & F in repairs Grating doom 100 mm dia of PTMT. (Minimum weight 25gms) complete all as specified and directed.
84S & F in repairs Grating doom 100/125 mm dia with waste hole of PTMT. (Minimum weight 40gms) complete all as specified and directed.
85S&F in repairs PVC connections 15 mm size with PTMT nuts, of length 450 mm & suitable for hot water supply complete all as specified and directed.
86S&F in repair PVC connections 15 mm size with PTMT nuts, of length 600 mm & suitable for hot water supply complete all as specified and directed.
87Dismantling 75/100/150 mm dia CI pipes including tee, branch piece, bend at any position (wall or laid in trench) complete all as specified and directed.
88S & F in repairs of ringfit PVC (SWR) pipe 75 mm bore, type B, single socketed, in any length with rubber ring, one end socketed and other plain duly fixed with cement solvent etc, fixed to walls complete all as specified and directed.
89S & F in repairs of ringfit PVC (SWR) pipe 110 mm bore, type B, single socketed, in any length with rubber ring, one end socketed and other plain duly fixed with cement solvent etc, fixed to walls complete all as specified and directed.
90S & F 75 mm bore PVC (SWR) bends of any radius, fixed with cement solvent, with oval access door complete all as specified and directed.
91S & F 110 mm bore PVC (SWR) bends of any radius, fixed with cement solvent, with oval access door complete all as specified and directed.
92S & F 75 mm bore PVC (SWR) branch piece single, (single Y) equal or unequal, with oval access door complete all as specified and directed.
93S & F 110 mm bore PVC (SWR) branch piece single, (single Y) equal or unequal, with oval access door complete all as specified and directed.
94S&F 75 mm bore PVC (SWR) vent cowl complete all as specified and directed.
95S&F 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
96S&F 75 mm bore PVC (SWR) floor trap, plain with grating and including jointing with solvent cement complete all as specified and directed.
97S&F in repairs sink without drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495 x 420mm bowl size 410 x 330 x 160 mm and including 32 mm waste pipe & coupling complete all as specified and directed.
98S&F in repairs sink without drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915 x 460mm bowl size 405 x 355 x 178 mm and including 32 mm waste pipe & coupling complete all as specified and directed.
99S&F in repairs vitreous China European water closet pan (pedestal pattern) white in colour with fixing bolts and flush pipe, connection to and including P or S trap CI/PVC as per existing and connecting flushing cistern and all joints, including plastic water closet seat cover white, closed pattern with flat bottom and cover and mild steel CP hinges complete all as specified and directed.
100S&F in repairs vitreous China water closet squatting pan, \\"Orissa pattern\\" white, size 580 x 440 mm with integral foot rest, including 'P' or 'S' trap CI/PVC as per existing and including connection to trap and to flushing pipe including provn of line concrete holding CI anti -syphonage pipe complete all as specified and directed.
101S&F in repairs PVC low level flushing cistern of 10 litres capacity, valve less, syphonic action type, white body, with inlet ball valve, float and handle including brackets complete all as specified and directed.
102S&F in repairs swivel shower rose size 125 mm of brass chromium plated any colour (minimum weight 40 gms) for fixing with 15mm dia steel pipe complete all as specified and directed.
103S&F for Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern including necessary cutting to floor tiles and connection to WC complete all as specified and directed.
104S&F in repairs, wash hand basins vitreous China flat back 450mmx300mm size white, first quality, with and including chromium plated waste grating 32mm size, waste coupling 32mm size ,PVC waste pipe 25mm bore heavy duty China and plug and porcelain stopper, brackets of Mild Steel angle iron (35mmx35mmx5mm) of suitable size including two coat of synthetic enamel paint over a coat of primer over angle iron brackets complete to walls complete all as specified and directed.
105S&F in repairs 600 mm x 450 mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs/PVC rawel plug with chromium plated brass screw and cup washer complete all as specified and directed.
106S&F in repairs soap dish, with metal dish brass chromium plated fixed to plugs complete all as specified and directed.
107S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
108Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed.
109Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar complete all as specified and directed.
110Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
111Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
112S&F in replacement 15 mm bore gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
113S&F in replacement 20 mm bore gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
114S& F in repair Pillar taps 15mm dia of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-110gms) complete all as specified and directed.
115Repair / maintenance of internal light fitting of any type like tube lights / wall bracket light fittings / ceiling lights / bulk head light / mirror lights etc in its position, testing all the components / parts, wiring etc, identifying and replacing the defective components like tube rod, side holders, holders, lamps etc complete all as specified and directed. Note: (i) The rate against the above mentioned item is deemed for cost of labour only. (ii) Cost of spares like capacitor, lamp holder, connector, connection wire etc. replaced against above mentioned item will be measured & paid separately under respective items of Sch 'A' here-in-below. (iii) The contractor's representative (supervisor) will report to concerned JE E/M at 0900hrs daily to collect the list of complaints and will submit the completion report on the same day before 1700hrs to the JE E/M. (iv) The contractor shall address all the given complaints within 24 hours from the time the list of complaints is handed over to him / his rep by the concerned JE E/M. In case the complaint is not addressed for whatsoever reason within the specified time limit (48 hrs), an amount of Rs 100/- per such complaint per day will be recovered from the amount due to him through RAR / Final Bill.The contractor shall engage separate team of technicians / repairer for each at SQN AREA B Zone (04 x teams). (v) The contractor shall maintain proper record of repair / maint in a binded compliant register and complaint slip books duly signed by the user and bringing out the details of spares replaced and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of light fittings with the concerned JE E/M against the supply only items here-in-below. (vii) During the contract period, if the same complaint is repeated, it will be regarded as a single complaint, and no additional payment will be made for addressing the repeated issue.
116M&L repair of point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for One light/Fan point controlled by one way switch 6 Amps 240 volts complete all as specified and directed.
117M&L repair of point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for one 3 / 6 Amps socket outlet point on independent board complete all as specified and directed.
118M&L repair of point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for one 3 / 6 Amps socket outlet point on same board complete all as specified and directed.
119M&L repair of point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for one light point controlled by two 2 way switch complete all as specified and directed.
120M&L repair of point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type one bell/ buzzer point controlled by one push button on the same board with other switches or independent complete all as specified and directed.
121M&L repair of point wiring with 2.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLSH cable size 2.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for one 15 Amps socket outlet point on independent board complete all as specified and directed.
122M & L for sub main wiring with 2 runs of 1.5 sqmm main wire along with 1 run of 1.5 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit/casing caping (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
123M & L for sub main wiring with 2 runs of 2.5 sqmm main wire along with 1 run of 2.5 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit/casing caping (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
124M & L for sub main wiring with 2 runs of 4.00 sqmm main wire along with 1 run of 4.00 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit/casing caping (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
125M & L for sub main wiring with 2 runs of 10.00 sqmm main wire along with 1 run of 10.00 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit/casing caping (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
126Supply only switch piano flush type SP one way, 5 / 6 Amps, 240 volt complete all as specified and directed.
127Supply only switch piano flush type SP one way, 15 Amps, 240 volt complete all as specified and directed.
128Supply only Socket outlet 5/6 Amps 3/5 pin flush type complete all as specified and as directed.
129Supply only Socket outlet 5/15 Amps 3/5 pin multipurpose flush type complete all as specified and as directed.
130Supply only switch socket combination 2 in 1 , 3/5 pin , 5 and 15 amps flush type multipurpose complete all as specified and directed.
131Supply only switch socket combination with box, 2 in 1 , 3/5 pin , 6 and 16 amps multipurpose flush type complete all as specified and directed.
132Supply only switch socket combination 5 pin 6 Amp, 5 pin, multipurpose, flush type complete all as specified and directed.
133Supply only switch socket combination 5 pin 5/6 Amp, flush type with box complete all as specified and directed.
134Supply only switch piano modular type one way, 10 Amps, 240 volt complete all as specified and directed.
135Supply only switch piano modular type one way 01 module, with neon indicator, 20 Amps, 240 volt complete all as specified and directed.
136Supply only switch piano modular type two way one module, 10 Amps independent, 240 volt complete all as specified and directed.
137Supply only modular type Bell push,10 A with neon indicator , 1 module complete all as specified and directed.
138Supply only modular type Bell push 5A complete all as specified and directed.
139Supply only socket outlet modular type 2/3 pin 6 Amps, 240 volts combined 2 module complete all as specified and directed.
140Supply only socket outlet modular type 2/3 pin, combined 2 module, 6/16 Amps, 240 volts complete all as specified and directed.
141Supply only 1 module blanking plate complete all as specified and directed.
142Supply only electronic modular fan regulator, stepped type( 5 step), white 120 W - 2 module complete all as specified and directed.
143Supply only ceiling rose, surface bakelite 65 x 50 mm three terminal complete all as specified and directed.
144Supply only PVC/polycarbonate lamp holder batten/angle type complete all as specified and directed.
145Supply only stepped type electronic fan regulator two module, with 5 step, AC 50 Hz 240 Volts grade 100 W complete all as specified and directed.
146Supply only Door Bell, Ding Dong AC. 230 volts, single pole completed all as specified and directed.
147S&F in replacement LED white light fitting mirror type surface and wall mounted with high out put diffuser 2 feet, 12 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
148Supply only PVC unbreakable surface boxes of size 4”x4” completed all as specified and directed.
149Supply only PVC unbreakable surface boxes of size 6”x6” completed all as specified and directed.
150Supply only PVC unbreakable surface boxes of size 4”x7” completed all as specified and directed.
151Supply only PVC unbreakable surface boxes of size 6”x8” completed all as specified and directed.
152Supply only PVC unbreakable surface boxes of size 8”x10” completed all as specified and directed.
153Supply only white cover plate with frame 1 or 2 module complete all as specified and directed.
154Supply only white cover plate with frame 3 module complete all as specified and directed.
155Supply only white cover plate with frame 4 module complete all as specified and directed.
156Supply only white cover plate with frame 6 module complete all as specified and directed.
157Supply only white cover plate with frame 8 module complete all as specified and directed.
158Supply only white cover plate with frame 12 module complete all as specified and directed.
159Supply only PVC unbreakable surface boxes suitable for modular switches 1 or 2 module complete all as specified and directed.
160Supply only PVC unbreakable surface boxes suitable for modular switches 3 module complete all as specified and directed.
161Supply only PVC unbreakable surface boxes suitable for modular switches 4 module complete all as specified and directed.
162Supply only PVC unbreakable surface boxes suitable for modular switches 6 module complete all as specified and directed.
163Supply only PVC unbreakable surface boxes suitable for modular switches 8 module complete all as specified and directed.
164Supply only PVC unbreakable surface boxes suitable for modular switches 12 module complete all as specified and directed.
165Supply and fixing in replacement 1100 volts grade heavy duty service cable 4 Sqmm two core PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed including PVC Conduit ISI Marked 20mm including all necessary bends, couplings, tees, and other accessories.Surface Saddling of PVC Conduit on Wall using approved saddles and fixing screws. Spacing as per specifications ( 1-meter intervals) complete all as specified and directed.
166Supply and fix in replacement 20 watt,230V 3 IN 1 surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper conductor cable from ceiling rose complete all as specified and directed.
167Supply and fix in replacement of recess type LED Downlight lights 12 W with ceiling cut out of dia 92 mm, Environmental friendly, energy saving, recess mounted downlighter with electronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully complete all as specified and directed..
168Supply and fix in replacement Surface mounted LED Downlight lights 12 W Environmental friendly, energy saving, recess mounted downlighter with electronic driver with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully complete all as specified and directed.
169Supply and fix in replacement COB light 12W LED Tiltable surface mounting and Environmental friendly, new generation, energy saving, decorative IP 66 complete all as specified and directed.
170Supply and fix in replacement Decorative wall mounting teakwood finish Wall Lamp with B22 LED 9W and connecting up with twin core twisted flexible copper conductor cable from ceiling rose complete all as specified and directed.
171Supply and fix in replacement surface/recess mounted 2' x 2' LED Panel lights 40 W LED 5700K, 240Volts and glare free symmetrical illumination suitable for Armstrong/Grid ceiling, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully complete all as specified and directed. Note: The quoted price shall include the cost of Light and its driver.
172M&L for securing loose wiring and repair to point wiring with necessary rigid non metallic PVC casing caping double lock type/ PVC conduit ISI mark of size not less than 25 mm inclusive of all accessories complete all as specified and directed.
173S&F in replacement of flexible conduit pipe ivory grey in colour of dia not less than 25 mm complete all a specified and directed.
174Taking down exhaust fan 200 mm to 450 mm sweep of any make sealing cable ends, dismantling blades ,and applying one coat painting with synthetic enamel paint(smoke grey) by spraying after cleaning thoroughly with kerosene oil or burning by blow lamp including filling cavities with filler etc, refixing the same in original position including provision of cable from ceiling rose or connector to fan, complete all as specified and directed. Note:-Cost of repairs / rewinding of motor will be measured and paid separately.
175Taking down Air circulator/Pedastal fan 450/600mm sweep of any make sealing cable ends, dismantling blades ,and applying one coat painting with synthetic enamel paint (Grey) by spraying after cleaning thoroughly with kerosene oil or burning by blow lamp including filling cavities with filler etc, refixing the same in original position including provision of cable from ceiling rose or connector to fan, complete all as specified and directed. Note:-Cost of repairs / rewinding of motor will be measured and paid separately.
176Supply and fixing in repair of Plug Top with indicator 3 pin 15/16 Amp AC 230 Volts complete all as specified and directed.
177Supply and fix in replacement indoor Profile LED strip of 12 watts/m linear flex , with separate electronic drivers of suitable and IP 65 protection complete ,Single phase, with aluminium profile including mounting on the ceiling as reqd at the site complete all as specified and directed. Note : Cost of electronic driver will be measured & paid for separately under respective items of BOQ.
178Supply and fix in replacement outdoor LED strip LED strip of 220 V linear flex, with fixing tape and end cap of suitable and IP 68 protection complete ,Single phase, mounting on the ceiling/ wall/ pillar as required at the site complete all as specified and directed. Note:- Cost of electronic driver and aluminium profile will be measured and paid for separately under respective items of BOQ.
179Supply and fix in replacement aluminium profile with accessories including mounting on the ceiling/wall as reqd at the site complete all as specified and directed.
180Supply and fix in replacement connector outdoor LED strip of 220 V mounting on the ceiling/wall/piller as reqd at the site complete all as specified and directed.
181Supply and fixing in replacement GI pipe bracket of 25 mm dia 1 mtr long bend to shape for street light fitting made out of 25 mm dia GI light grade pipe fixed on building/pole using suitable FI clamp including necessary new nut, bolt and washer complete all as specified and directed.
182Supply and fix in replacement Electronic Drivers, suitable for 9W, 10W, 20W, 30W, and 40W LED light/security light fittings, of compatible specifications and make as existing, including all necessary connections, testing, and commissioning, complete all as specified and directed.
183Supply and fix in replacement Electronic Drivers 2 to 30Amp for indoor/outdoor LED strip suitable and IP 68 protection complete,Single phase,with aluminium profile including mounting on the ceiling as required complete as specified and directed .
184Supply and fix in replacement factory made epoxy powder coated Distribution Board TP & N 4 way double door (VTPN MCCB DB ) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified . Note:MCBs/ MCCBs will be measured and paid separately under respective Sch A item in the schedule
185Supply and fix in replacement MCB DB 12 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size along with its accessories by removing from existing circuits and re-fixing the new DBs and circuits complete all as specified and directed. Note - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced.
186Dittto all as per item no 185 above but 08 way SPN DB (Double door)
187Dittto all as per item no 185 above but 04 way SPN DB (Single door)
188Dittto all as per item no 185 above but 04 way SPN DB (Double door)
189Supply and fix in replacement MCCB with rating of 100 Amps, 415Volts 3pole with 16kA breaking capacity,thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capacity(Icu).MCCB should be with suitable spreaders and phase barriers for each terminals complete all as specified and directed.
190Supply and fix in replacement MCCB with rating of 63 Amps, 415Volts 3pole with 16kA breaking capacity,thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capacity(Icu).MCCB should be with suitable spreaders and phase barriers for each terminals complete all as specified and directed.
191Supply only C Curve MCB SP 6-32 Amps working on 240 volts,50 Hz 10 KA all as specified and directed.
192Supply only C Curve MCB DP 6-32 Amps working on 240 volts,50 Hz 10 KA all as specified and directed.
193Supply only C Curve MCB SPN 40-63 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed.
194Supply only C Curve MCB TP 40-63 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed.
195Supply only C Curve MCB TPN 40-63 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed.
196Supply and fix in replacement sheet metal enclosures Single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volts complete with all accessories etc complete all as specified and directed.
197Supply and fix in replacement sheet metal enclosures Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amps, 240 volts complete with all accessories etc complete all as specified and directed.
198M&L in replacement of earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc complete all as specified and directed.
199Dismantling and removing rusted louvers suitable for 150/230/300/450/600 mm sweep exhaust fan S&F in repair of MS louvers duly painted gray coloured suitable for 150/230/300/450/600 mm heavy duty exhaust fan alongwith four number mounting bracket with bolts, nuts washers etc complete all as specified and directed.
200Supply and fix in replacement GI pipe ceiling fan down rod of 15 mm dia up to 3 feet long for ceiling fan made out of 15 mm dia GI heavy grade pipe fixed on ceiling using suitable clamp including necessary new nut, bolt and washer complete all as specified and directed.
201Taking down ceiling fan/exhaust fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing,etc, reassembling and hanging up/fixing back at its original position, connecting up and testing complete all as specified and directed.
202Supply only capacitor of 2.5/4 mfd for ceiling fan/exhaust fan complete all as specified and directed. Make:Tibcon/Epcos/Havells
203Supply only bearing No.6201/6202/6203 or any other No matching to the existing size and suitable for exhaust fan/wall mounted fan complete all as specified and directed.
204S&F in replacement LED building sensor security light fitting 24 W, IP-65 protection made up of die-cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment complete all as specified and directed.
205Disconnecting and taking down existing unserviceable geyser of 25/50/100 litrs capacity of any make /brand,taking it into civil workshop for repairing.Opening the geyser and dismantling all parts and taking out inner tank/container, removing dents making to shape including welding/brazing the leakage portion,filling the portion between inner tank and out casing of geyser with new glass wool heat insulating material.Reassembling and painting the outer casing of geyser with two coats of superior quality synthetic enamelled paint and refixing to original place complete all as specified and directed.Note:1.Cost spares such as Thermostate,heating element etc will be measured and paid for separately under respective item of BOQ as supply only.
206Supply only thermostat and cutout set electronic type,temperature adjustable from 0-80 degree Celsius suitable for geyser of 25 to 100 ltrs capacity complete all as specified and directed.
207Supply only heating element of capacity 2/3 KW of any type and shape suitable for Existing 25 to 100 ltrs capacity geysers complete all as specified and directed.
208Supply only flow unit (inner pipe assembly) suitable for geyser of 25 ltrs of capacity and for vertical/horizontal type including rubber ring/gasket complete all as specified and directed.
209Supply only metallic flexible hot water connection 600/900 mm long including necessary washers suitable for geysers of 25 to 100 ltr capacity complete all as specified and directed.
210Supply only NRV valve of size 15 mm dia of brass complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57244446
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 34.98 Lakhs
LAST DATE 16-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Comprehensive Maintenance B/R And E/M Works Of Certain Md Accn In Zone ‘C Area At Nda Khadakwasla
Basic Detail
Tender No 8095/E8
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 27 Aug 2026
Submission Date 16 Sep 2026
Open Date 18 Sep 2026
Finance
Tender Value 34.98 Lakhs
Tender Fee 500
EMD 69960
Exemption Available
Document List
6a392fb9-e3f8-4eaf-9518-343dca9140f5.html
8095.pdf
BOQ_881538.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Sep 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

6a392fb9-e3f8-4eaf-9518-343dca9140f5.html

pdf

8095.pdf

xls

BOQ_881538.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders