Tender for Provision Of Deficient Stp And Allied Works At Hisar Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Lump sum price worked out by the contractor for \\"BUILDING WORKS\\" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 2 | Lump sum price worked out by the contractor for \\"INTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 3 | Lump sum price worked out by the contractor for \\"INTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-III\\" representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 4 | Lump sum price worked out by the contractor for \\"ROAD, PATH AND CULVERT\\" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 5 | Lump sum price worked out by the contractor for \\"AREA DRAINAGE\\" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 6 | Lump sum price worked out by the contractor for \\"SECURITY WALL & FENCING\\" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 7 | Lump sum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 8 | Lump sum price worked out by the contractor for \\"EXTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 9 | Lump sum price worked out by the contractor for \\"DG SET\\" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 10 | Lump sum price worked out by the contractor for \\"TREATED WATER SUPPLY\\" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 11 | Lump sum price worked out by the contractor for \\"SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK\\" as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 12 | Sch 'A' Part-XII MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XI (SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK schedule). |
| 13 | INTERNAL ELECTRIFICATION |
| 14 | S & F for Highly efficient LED Bulbs, 9 watts complete all as specified and directed. |
| 15 | EXTERNAL WATER SUPPLY |
| 16 | M&L for Making trench hole instead of trench upto 50mm dia G.I/D.I pipe by hand bocky (manually) below butumineous road/concrete road/WBM road in soft/hard soil and disposal of surplus soil from the trench complete as per direction of Engineer-in-Charge (Action portion of trenchesless hole shall be paid) |
| 17 | Making Connection with Existing pipe line of 50mm dia including cutting of pipe with including necessary fittings like tee, socket, reducer etc. Making goods complete with necessary items nothing will be paid separatly. |
| 18 | EXTERNAL ELECTRIFICATION |
| 19 | Supply and fix SMC street light control box of size 300X200X105mm including aluminium bus bar of adequate capacity and one number MCB SP 16 Amps 230 volts including connecting up with electrical connections and fixing and clamping including taking out old unsv junction box complete and all as directed |
| 20 | Supply of 400 KVA Outdoor type Compact Substation consisting of Transformer,HT switchgear and LT Switchgear and confirming to IEC-62227. a) Transformer: 400 KVA Copper wound 11KV /433 V DYn11, Dry Cast resin type Transformer with tapping range +10 to -10% @ 2.5% ( with tolerance), class F , with surge restorers, Digital WTI, IS1171 as per b) HT Compartment: 11KV, 21kA for 3 Sec . 630 A 50 Hz, gas insulated VCB in SS tank in sheet enclosure having provision for one no. direct connection of Incoming supply cable upto 300sq mm and one no. VCB( Manually charging & closing) in series with LBS between VCB and Transformer, Self Powered Relay 3 O/C +1 E/F Relay type CSPR-V5, mechanical ON/OFF indicator, trip coil , Manual Close & Trip PB, live cable indicator, mechanical interlocks, pad locking facility, SF6 gas manometer, cable boots, 3 nos. CTs with Ratio -/1A, Cl: 5P10, 2.5 VA for protection c) LV side compartment : one no. MCCB of 630A, 36kA, 4Pole, Microprocessor based release with arrangement for bottom cable termination Add extra Rs 9000/- for integrated steel cubical panel IP 54 to house upto 03 Nos additional outgoing switchgears with proper rating busbar drop,supports etc with arrangment for cable termination etc. (switchgears is not included in this) Add extra steel cubical panel IP 54 to house upto 03 Nos additional outgoing switchgears with proper rating busbar drop,supports etc with arrangment for cable termination etc.(switchgears is not included in this), complete all as specified and directed. |
| 21 | Providing and fixing mechanical ISI Marked Foam (AFFF) type Fire Extinguisher 135 ltrs. capacity IS:16018 mounted on trolley wheels conforming to IS: 14951 fitted with Forged Brass squeeze lever discharge valve, conforming to IS:15683:2006, complete with initial refill consisting of ISI Marked CO2 gas cartridge of 120 gms capacity conforming to IS:4947 and ISI Marked AFFF conforming to IS:4989, suitable for operating between + 5 C to + 55 C, Fire Rating Class-3A & 34B, complete all as specified and directed. |
| 22 | Providing and fixing Carbon-di-oxide fire extinguishers of capacity 22.5 kg, ISI Marked, consisting of Seamless M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, trolly mounted, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge, complete all as specified and directed.Note: Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied. |
| 23 | Providing and fixing Carbon-di-oxide fire extinguishers of capacity 4.5 kg, ISI Marked, consisting of Seamless MS cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge, complete all as specified and directed. Note: Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied. |
| 24 | Providing and fixing ABC MAP 90 (ISI marked) fire extinguishers of capacity 4.5 kg, conforming to IS:15683, consisting of welded SS 304 cylindrical body squeeze lever discharge valve 30 cm long high pressure discharge hose, discharge nozzle suspension bracket ISI marked finished externally with red enamel paint and fixed to wall with brackets complete with internal charger, complete all as specified and directed. |
| 25 | Providing and fixing of self illuminated / auto glow Fire signages printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, for Exit, extinguishers and warning signs etc. suspended from ceiling or fixed to the walls with accessories as required at site, complete all as specified and directed. |
| 26 | DG SET |
| 27 | Supply, installation,test and commissioning Silent diesel driven engine generating set , 4 cylinder, Bore x stroke 105 x 125, 415 Volts ,3 Phase 4 wire, 50 Hz , 0.8PF, 250 KVA speed variation of engine 1500 RPM, continuous rating directly coupled alternator at 1500 RPM,water cooled turbo charged ,with common base plate frame flexible coupling ,electronic control panel for engine ,control panel having meter and sound proof canopy as per CPCB norms-IV(+), displaying battery voltage, coolant water temperature ,lubricating oil pressure engine speed and engine hours ,safety trip and indication for high water temperature, low lubricating oil pressure and over speed, alternator self excited, self regulated brushless excitation. Voltage regulation (+/-1%)of related voltage from no load to full load, including AMF Panel indoor type, acoustic enclosure, Fuel piping ,Exhaust piping ,control wiring cable from engine to control panel ,all as specified and as directed by Engineer-in-charge.The generator set shall be Skid mounting type base frame fabricated from suitable MS channel suitably machined to ensure perfect alignment of the engine & alternator with rigid construction & necessary reinforcement to ensure minimum vibrations. AVM Pads: Suitable number of AVM pads shall be supplied with Silent DG Set. |
| 28 | (a) Diesel Engine: The Engine as per IS : 10001/10002, shall be vertical 4 cylinder (1500 PM. Radiator water cooled ,turbo charged /naturally not less than 90 BHP @ at 1500 RPM under NTP conditions of BS: 5514. The engine shall be provided with electrical starting arrangement & shall give the electrical output of 100 KVA/80 KW at 0.8 power factor, 415 volts at the alternator terminal.(i) A1 class Governor(ii) Battery charging Alternator(iii) Fuel filter.(iv) Lube oil filter(v) Air cleaner(vi) Engine safety sensors (LLOP & HWT)(vii) Radiator Assembly, Radiator cooling fan ,water pump ,thermostat.(viii) RPM/Hour meter.(ix) Water Temp gauge, Oil pressure gauge, Oil temp gauge. (x) Fuel hoses.(xi) Protection Guard for safety of person from moving/rotating parts of generating set coupling Please Enable Macros to View BoQ information |
| 29 | (a) Diesel Engine: The Engine as per IS : 10001/10002, shall be vertical 4 cylinder (1500 PM. Radiator water cooled ,turbo charged /naturally not less than 90 BHP @ at 1500 RPM under NTP conditions of BS: 5514. The engine shall be provided with electrical starting arrangement & shall give the electrical output of 100 KVA/80 KW at 0.8 power factor, 415 volts at the alternator terminal.(i) A1 class Governor(ii) Battery charging Alternator(iii) Fuel filter.(iv) Lube oil filter(v) Air cleaner(vi) Engine safety sensors (LLOP & HWT)(vii) Radiator Assembly, Radiator cooling fan ,water pump ,thermostat.(viii) RPM/Hour meter.(ix) Water Temp gauge, Oil pressure gauge, Oil temp gauge. (x) Fuel hoses.(xi) Protection Guard for safety of person from moving/rotating parts of generating set coupling Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 31 daysOct 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 33 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender