Tender For Repair And Maintenance Of Internal Wiring Fitting, Mcbs Service Cable And Other Connected Works At Chinta, Chnichora And Jai Ghati Area At Bhalra Mil Stn Under Age (I) Bhalra (Nit No. 60 Of 2026-27)
Tender Value
10 Lakhs
Estimated cost
Bid Submission
17 Sep 2026
17 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nagrota → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Internal Wiring Fitting, Mcbs Service Cable And Other Connected Works At Chinta, Chnichora And Jai Ghati Area At Bhalra Mil Stn Under Age (I) Bhalra (Nit No. 60 Of 2026-27)
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants,regulators, sockets, MCBs, DB etc. to be measured separately), removing materials to store for kepping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc. all as specified and directed. |
| 2 | M&L for point wiring complete with cable PVC insulated, unsheathed, 1100V grade conforming to IS for one way SP, 5A with 1.5 Sqmm of cable of nominal area multistranded copper conductor FRLS drawn through and including 20 mm PVC Casing Capping including accessories on wall/floor/ceiling (on surface) etc with PVC terminal box for mounting switch, socket outlet etc complete with all accessories/fittings including PVC insulated continuous muli standred copper earth wire (1.5 Sqmm) and connected to common earth dolly complete for the following :-(a) One light/holder point or one fan point / bell point controlled by one switch. |
| 3 | All as per item No 02 here-in-before but one 3/5 pin socket otutlet, 5 amps, on same board , with cables 1.5 sq mm size with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing specified and directed. |
| 4 | All as per item No 02 here-in-before but one 3/5 pin socket otutlet, 5 amps, on independent board , with cables 1.5 sq mm size with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing specified and directed. |
| 5 | All as per item No 02 here-in-before but One 5 pin socket out let, 15 Amps, on independent board ,with cables 2.5 sq mm size with 2.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing specified and directed. |
| 6 | M&L for point wiring complete with cable PVC insulated, unsheathed, 1100V grade conforming to IS for one way SP, 5A with 1.5 Sqmm of cable of nominal area multistranded copper conductor FRLS drawn through and including PVC Conduit including accessories on wall/floor/ceiling (on surface) etc with 16G MS pressed steel terminal box with 3mm thick laminated sheet cover for mounting switch, socket outlet etc complete with all accessories/fittings including PVC insulated continuous muli standred copper earth wire (1.5 Sqmm) and connected to common earth dolly complete for the following :-(a) One light/holder point or one fan point/ bell point controlled by one switch. |
| 7 | All as per item No 06 here-in-before but one 3/5 pin socket otutlet, 5 amps, on same board , with cables 1.5 sq mm size with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing specified and directed. |
| 8 | All as per item No 06 here-in-before but one 3/5 pin socket outlet, 5 amps, on independent board , with cables 1.5 sq mm size with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing specified and directed. |
| 9 | All as per item No 06 here-in-before but One 5 pin socket out let, 15 Amps, on independent board, with cables 2.5 sq mm size with 2.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing specified and directed. |
| 10 | Supply and fix of LED tube light fittings 1 x 20 watts with LED tube complete, fixinh on recess/surfaces etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible cable of 0.75sqmm 3 core copper conductor from ceiling rose to light fittings complete all as specified and as directed. (Make:- Philips/Havells/Bajaj/ Crompton Greaves |
| 11 | S & F in replacement 9 Watt LED bulb all as specified and directed. Make :- Havells /Philips/Cropmton Greaves/Syska. |
| 12 | S & F in replacement 7 W LED bulb all as specified and directed. Make: Havells /Philips/Cropmton/Syska |
| 13 | Supply and fix of LED Recess mounting 2x2 feet low glare luminaire 30 watt with decorative performance for metalic false ceiling type armstrong/US gypsum or similar ceiling mounting system including LED light. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible cable of 0.75sqmm 3 core copper conductor from ceiling rose to light fittings complete all as specified and as directed. (Make:- Philips/Havells/Bajaj/ Crompton Greaves |
| 14 | S&F LED light fitting 1x9W/1x10W bulk head luminaires including LED light driver holder connercting up with three core flexible copper conductor cable of suitable size 230V,50 HZ all as specified and directed. |
| 15 | S & F in replacement switch piano type 5 A flush button single pole one way complete all as specified & directed. Make - Legrand/Havells/Anchor. |
| 16 | S & F in replacement socket 2 in 1, 5 Pin, 5 Amp complete all as specified & directed . Make - Legrand/Havells/Anchor. |
| 17 | S & F in replacement Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal complete all as specified & directed . Make - Legrand/Havells/Anchor. |
| 18 | S & F in replacement Switch socket combination 5 in 1, 3 pin, 5 and 15 amp flush type universal complete all as specified & directed . Make - Legrand/Havells/Anchor. |
| 19 | S & F in replacement ceiling rose, 3 phase/PVC/ Polycarbonate, isolated body complete all as specified & directed . Make - Legrand/Havells/Anchor. |
| 20 | S & F in replacement Bell buzzer ding dong AC 230 Volt, single pole Make - Legrand/Havells/Anchor. |
| 21 | S & F in replacement bell switch flush type 5 A flush button single pole one way.Make - Legrand/Havells/Anchor. |
| 22 | S&F in replacement MCB 6-32 Amps SP 'C' series 240 V, 50 Hz, breaking capacity 10 KA suitable for lighting and other domestic loads complete all as specified and directed. Make - ABB/siemens /Legrand/Havells/Scheinder |
| 23 | S&F in replacement MCB 40 Amps SP 'C' series 240 V, 50 Hz, breaking capacity 10 KA suitable for lighting and other domestic loads complete all as specified and directed. Make - ABB/siemens/Legrand/Havells/ Scheinder |
| 24 | S&F inreplacement MCB 32 Amps SPN 'C' series240 V, 50 Hz, breaking capacity 10 KA. Make - ABB/siemens/Legrand/Havells/Scheinder |
| 25 | S&F inreplacement MCB 40 -63 Amps SPN 'C' series240 V, 50 Hz, breaking capacity 10 KA. Make - ABB/siemens/Legrand/Havells/Scheinder |
| 26 | S & F in replacement MCB TPN/FP 16 to 32 Amps 415 V 50 Hz, breaking capacity 10 KA 'C' curvecomplete with connection testing and commissioning all as specified and directed. Make - ABB/siemens/Legrand/ Havells/Scheinder |
| 27 | S & F in replacement MCB TPN/FP 100 Amps 415 V 50 Hz, breaking capacity 10 KA 'C' curve complete with connection testing and commissioning all as specified and directed. Make - ABB/siemens/Legrand/Havells/ Scheinder |
| 28 | Supply and fix sheet metal enclosure DB SPN 240 volts 4 way single door type with 200 amps rated bus bar for fixing MCB complete all as specified and as directed. Make- Havells/Standard. |
| 29 | Supply and fix sheet metal enclosure DB SPN 240 volts 4 way double door type with 200 amps rated bus bar for fixing MCB complete all as specified and as directed. Make- Havells/Standard. |
| 30 | Supply and fix sheet metal enclosure DB SPN 240 volts 8 way single door type with 200 amps rated bus bar for fixing MCB complete all as specified and as directed. Make- Havells/Standard. |
| 31 | Supply and fix sheet metal enclosure DB SPN 240 volts 8 way double door type with 200 amps rated bus bar for fixing MCB complete all as specified and as directed. Make- Havells/Standard. |
| 32 | S & F Wiring for circuit/submain wiring in PVC casing caping of size 20/30 mm alongwith earth wire with 2 x 4.0 Sq mm + 1 x 4.0 Sq mm Earth wire in green colour sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required including taking down old UNSV submain wiring. |
| 33 | S & F Wiring for circuit/submain wiring in PVC casing caping of size 20/30 mm alongwith earth wire with 2 x 6.0 Sq mm + 1 x 6.0 Sq mm Earth wire in green colour sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required including taking down old UNSV submain wiring. |
| 34 | S&F 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire one twin core 10 sq mm solid conductor all as specified and directed by Engr- in - Charge. |
| 35 | S&F 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire one twin core 16 sq mm solid conductor all as specified and directed by Engr- in - Charge. |
| 36 | M&L Earthing complete with galvanised steel earth plate electrode, 600mmx 600mm x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level,connected to galvanised earth lead wire 4.0mm dia by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including taking out old UNSV earthing and all as specified and directed. |
| 37 | (a) Supply only PVC insulated multistranded FRLS copper conductor of size 1.5 sqmm single core |
| 38 | (b) all as per item 36 above but of size 2.5 sqmm |
| 39 | (c) all as per item 36 above but of size 4.0 sqmm |
| 40 | Supply only PVC casing capping of size 20 mm ISI marked medium grade all as specified & directed |
| 41 | all as per item 38 above but of size 25 mm |
| 42 | Supply and fixing (concealed flush to wall) factory made VTPN (Vertical type), 4 Way 415V, as per IEC 61439-3, DB (made out of CRCA sheet not less than 1.2mm thick, with bus bar rating of suitable capacity, with two neutral bar, 2 earth bar and cable tie for cable management, suitable for MCCB 4 pole upto 125Amp, as incomer and suitable for mounting MCBs as outgoing, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, The DBs shall be of IP-54 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.Note :- MCBs for outgoing shall be measured and paid separately under appropriate item of BOQ.directed. |
| 43 | Supply and fixing in repair MCCBs 125 Amp 4 pole 415 V , adjustable overload settings (0.8 to 1.0) to Ics=100% Icu short circuit setting fixed breaking capacity 25 KA complete all as specified and directed. |
| 44 | Supply and fixing Rechargeable Emergency inverter type with backup of 3 hrs, LED batten light fitting 20 Watts, compact type, LED cool light, 6500K, 2000lm with operating voltage 220 V-240 V, energy efficient, AC, minimum 3 feet long with decorative box linear, including 2 core flexible copper cable from ceiling rose to tubelight complete all as specified and directed by Engineer-in-Charge |
| 45 | S & F in replacement Switch socket combination with box 2 in 1, 5 pin, 5 Amp flush type universal complete all as specified & directed . Make - Legrand/Havells/ Anchor. |
| 46 | S & F in replacement Switch socket combination with box 5 in 1, 3 pin, 5 and 15 amp flush type universal complete all as specified & directed . Make - Legrand/ Havells/Anchor. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysSep 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender