Tender For Annual Maintenance Contract Of Traction & Psi For 11 Stations, One Depot And 2 Rss Of Navi Mumbai Metro Line-1 For 3 Years Extendable Up To 1 Year
Tender Value
8.07 Crore
Estimated cost
Bid Submission
28 Sep 2026
28 days left
EMD
4.03 Lakhs
Bank guarantee accepted
Document Fee
23600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thane → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Maintenance Contract Of Traction & Psi For 11 Stations, One Depot And 2 Rss Of Navi Mumbai Metro Line-1 For 3 Years Extendable Up To 1 Year
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 1: Preventive Maintenance for OHE for 1 Year |
| 2 | Maintenance of Cantilever assembly, OHE Structure, TTU, DA and allied OHE SPS and structures. |
| 3 | Maintenance of Catenary system (Contact wire, catenary wire, droppers, OPC, BEC, 1.1 KV RC, Current Collection Test) |
| 4 | Maintenance of all type of 25 KV OHE Jumpers |
| 5 | Maintenance of Anti Creep Centre (ACC), Anti Creep Anchor (ACA) and Fix Termination Anchor (FTA arrangement) |
| 6 | Maintenance of depot and Mainline Isolators, Interrupter, Voltage transformer |
| 7 | Maintenance of Overlaps (insulated and uninsulated} |
| 8 | Maintenance of Cross over & Turnouts |
| 9 | Maintenance of all type Section Insulator Assembly & Neutral Section assembly |
| 10 | Maintenance of BWA type Auto tension Device (ATD) |
| 11 | Maintenance of ITL |
| 12 | Maintenance of Earthing System with its whitewash/painting, grass cutting (as required), tree trimming (as required) & value writing in depot (YRLY) |
| 13 | Reconditioning of Earth pit with materials & when required |
| 14 | Current Collection Test |
| 15 | Breakdown Maintenance & other for Over Head Equipment of NMM |
| 16 | Breakdown attention by a gang for restoration of 25 KV OHE/PSI during accidents/unusual occurrence for checking OHE parameters. Breakdown attention gang shall be a part of CM/PM maintenance team. |
| 17 | Panto entanglement due to OHE component like Turn out, Overlap, non OHE zone, Jumper, Dropper, Cantilever steady arm & other component of Cantilever, Section insulator, Neutral Section, Foreign Material etc. |
| 18 | Erection of Catenary wire splicing or Contact wire splicing |
| 19 | Replacement / Re-erection of various types of insulators |
| 20 | Splicing of OPC |
| 21 | Replacement/ Re-erection of Section Insulator I(double rod type), Neutral Section assembly |
| 22 | Replacement / Re-erection BWT types of ATD, Interrupter/BM, VT, Isolator 'including loading & unloading' |
| 23 | Replacement/ Re-erection of Single/Double/Tripple bracketassembly Cantilever |
| 24 | CAD Weld from ITL to Rail. |
| 25 | Stencilling of OHE structure with materias |
| 26 | Repair of discharge rod without material |
| 27 | Supply & Erection of all types of boards |
| 28 | Rectification of leaning mast with material |
| 29 | Replacement of OHE light sensor aviator light/bulb indicator Red/Green |
| 30 | Schedule 2: Miscellaneous & consumable items including small tools etc. for OHE |
| 31 | Miscellaneous & consumable items including small tools, testing of equipment etc. and payment shall be made as per actual expenditure |
| 32 | Schedule 3: Part -I - Preventive Maintenance for Power Supply (RSS. ASS & Switching Post) |
| 33 | Preventive Maintenance of 25MVA, 220/33 KV Transformers |
| 34 | Transformer oil filtration- 25 MVA transformer |
| 35 | Preventive Maintenance of 10MVA, 33/27.5 KV Transformers |
| 36 | Transformer oil filtration- 10 MVA transformer |
| 37 | Maintenance of 220 KV GIS for 2 Bay out of 5 |
| 38 | Maintenance of 33 KV GIS |
| 39 | Maintenance of 25 KV GIS |
| 40 | Maintenance of 33kV/415V Dry Type Transformer |
| 41 | Maintenance of ACDB |
| 42 | Maintenance of DCDB |
| 43 | Maintenance of Battery Charger |
| 44 | Maintenance of Battery Bank |
| 45 | Maintenance of Earthing System with its whitewash/paintinG & value writina |
| 46 | Maintenance of Burried Rail |
| 47 | UPS ( 6KVA ) |
| 48 | UPS ( 5 KVA ) |
| 49 | Preventive Maintenance activities for ASS Equipments |
| 50 | Maintenance of 33 KV RMU |
| 51 | Maintenance of Dry type Transformer |
| 52 | Maintenance of Battery Charger |
| 53 | Maintenance of Battery Bank |
| 54 | Maintenance of ACDB |
| 55 | Maintenance of DCDB |
| 56 | Maintenance of IGBT |
| 57 | Transportation charge including driver and all fuel charges, 24x7 monthly services up to 2,000 KMs per month (Camper Yoddha), including all maintenance charges. Any additional kilometers beyond 2,000 KMs shall be charged on a pro-rata basis. |
| 58 | Switching Post & Viaduct Light |
| 59 | Viaduct Lighting and Power sockets as & when required |
| 60 | Schedule 3: Part- Il - Breakdown Maintenance activities |
| 61 | 33kV and 25kV cable end termination jointing work (Jointing kit will be provided by Maha-Metro & Contractor has to provide certified jointer by OEM) |
| 62 | 33kV and 25kVcable straight through joint on site (Jointing kit will be provided by Maha-Metro & Contractor has to provide certified jointer by OEM) |
| 63 | Breakdown maintenance for 220 KV GIS By OEM |
| 64 | Breakdown maintenance for 33 KV GIS by OEM |
| 65 | Breakdown maintenance for 25 kv GIS by OEM |
| 66 | Breakdown maintenance for 33 KV RMU by OEM |
| 67 | Breakdown Maintenance for 25MVA Auxiliarry trafo by OEM |
| 68 | Breakdown Maintenance for 25MVA Auxiliarry trafo NIFPS by OEM |
| 69 | Breakdown Maintenance for 10MVA Traction Trafo |
| 70 | Breakdown Maintenance for 10MVA Traction Trafo NIFPS |
| 71 | Breakdown Maintenance of 220/33/25 KV CRP/SAS by OEM |
| 72 | Breakdown Maintenance of OCC SCADA/RTU by OEM |
| 73 | Breakdown Maintenance of IGBT by OEM |
| 74 | Replacement & Laying of 33&25kV Cable on Viaduct |
| 75 | Replacement & Laying of 33&25kV Cable in ground |
| 76 | Laying of Control & LT Cable upto 70 Sq.mm. |
| 77 | Hire charge of diesdel Truck-9Tonne for shifting of matrial form store to site( As & when required ) |
| 78 | SF6 Gas multi analyser |
| 79 | Breakdowan maintenance of 33KV DTT (ABB) |
| 80 | Semi skilled worker ( as when required) |
| 81 | Supply of 245kV CGL make condenser bushing |
| 82 | Supply of 36kV porcelain bushing with metal part assembly |
| 83 | Supply of 52kV CGL make condenser bushing |
| 84 | Supply of 36kV porcelain bushing with metal part assembly |
| 85 | Schedule 4: Miscellaneous & consumable items including small tools etc. for PSI |
| 86 | Provisional Sums: Miscellaneous & consumable items and payment shall be made as per actual expenditure Schedule 1: Preventive Maintenance for OHE for 1 Year Part (I) - Preventive Maintenance for Over Head Equipment (OHE) of NMM SN Description of Work Unit ofMeasurement Total Qty of Assets Rate in INR(incl GST) Amount in INR (incl. GST) 1.1 Maintenance of Cantilever assembly, OHE Structure, TTU, DA and allied OHE SPS and structures. Nos. 2312.0 677.71 1566865.52 1.2 Maintenance of Catenary system (Contact wire, catenary wire, droppers, OPC, BEC, 1.1 KV RC, Current Collection Test) Per TKM 122.0 4066.28 496086.16 1.3 Maintenance of all type of 25 KV OHE Jumpers Nos. 161.0 655.76 105577.36 1.4 Maintenance of Anti Creep Centre (ACC), Anti Creep Anchor (ACA) and Fix Termination Anchor (FTA arrangement) Nos. 89.0 1639.4 145906.6 1.5 Maintenance of depot and Mainline Isolators, Interrupter, Voltage transformer No. 84.0 1639.4 137709.6 1.6 Maintenance of Overlaps (insulated and uninsulated} No. 26.0 1639.4 42624.4 1.7 Maintenance of Cross over & Turnouts Nos. 40.0 4066.28 162651.2 1.8 Maintenance of all type Section Insulator Assembly & Neutral Section assembly Nos. 42.0 4066.28 170783.76 1.9 Maintenance of BWA type Auto tension Device (ATD) Nos. 84.0 2033.12 170782.08 1.1 Maintenance of ITL Nos. 22.0 546.46 12022.12 1.11 Maintenance of Earthing System with its whitewash/painting, grass cutting (as required), tree trimming (as required) & value writing in depot (YRLY) Nos. 51.0 498.27 25411.77 1.12 Reconditioning of Earth pit with materials & when required Nos. 51.0 1626.51 82952.01 1.13 Current Collection Test Per TKM 22.4 1062.6 23802.24 Part (II) - Breakdown Maintenance & other for Over Head Equipment of NMM 3.1 Breakdown attention by a gang for restoration of 25 KV OHE/PSI during accidents/unusual occurrence for checking OHE parameters. Breakdown attention gang shall be a part of CM/PM maintenance team. Nos. 3.0 17582.35 52747.05 3.2 Panto entanglement due to OHE component like Turn out, Overlap, non OHE zone, Jumper, Dropper, Cantilever steady arm & other component of Cantilever, Section insulator, Neutral Section, Foreign Material etc. Nos. 4.0 12857.45 51429.8 3.3 Erection of Catenary wire splicing or Contact wire splicing Nos. 4.0 17582.35 70329.4 3.4 Replacement / Re-erection of various types of insulators Nos. 6.0 6428.72 38572.32 3.5 Splicing of OPC Nos. 4.0 4853.75 19415.0 3.6 Replacement/ Re-erection of Section Insulator I(double rod type), Neutral Section assembly Nos. 2.0 25975.88 51951.76 3.7 Replacement / Re-erection BWT types of ATD, Interrupter/BM, VT, Isolator 'including loading & unloading' Nos. 4.0 80396.56 321586.24 3.8 Replacement/ Re-erection of Single/Double/Tripple bracketassembly Cantilever Nos. 4.0 6555.55 26222.2 3.9 CAD Weld from ITL to Rail. Nos. 10.0 8251.49 82514.9 3.1 Stencilling of OHE structure with materias Nos. 100.0 448.4 44840.0 3.11 Repair of discharge rod without material Nos. 100.0 109.74 10974.0 3.12 Supply & Erection of all types of boards Nos. 10.0 1475.0 14750.0 3.13 Rectification of leaning mast with material Nos. 1.0 10938.6 10938.6 3.14 Replacement of OHE light sensor aviator light/bulb indicator Red/Green Nos. 6.0 1475.0 8850.0 Total of Schedule (1) 3948296.09 Schedule 2: Miscellaneous & consumable items including small tools etc. for OHE SN Description of Work Unit ofMeasurement Total Qty. of Assets 1.1 Miscellaneous & consumable items including small tools, testing of equipment etc. and payment shall be made as per actual expenditure Lump Sum 1.0 236000.0 236000.0 Total of Schedule (2) 236000.0 Grand Total (Schedule 1 + Schedule 2) 4184296.09 Schedule 3: Part -I - Preventive Maintenance for Power Supply (RSS. ASS & Switching Post) SN Description of Work Unit of Measurement Total Qty. of Assets Rate in INR(incl GST) Amount in INR (incl. GST) A Preventive Maintenance activities for RSS Equipments 1.1 Preventive Maintenance of 25MVA, 220/33 KV Transformers Nos 2.0 318600.0 637200.0 1.2 Transformer oil filtration- 25 MVA transformer Per ltr 47200.0 3.54 167088.0 1.3 Preventive Maintenance of 10MVA, 33/27.5 KV Transformers Nos 4.0 265500.0 1062000.0 1.4 Transformer oil filtration- 10 MVA transformer Per ltr 24000.0 3.54 84960.0 1.5 Maintenance of 220 KV GIS for 2 Bay out of 5 Nos 2.0 2006000.0 4012000.0 1.6 Maintenance of 33 KV GIS Verticals 25.0 33040.0 826000.0 1.7 Maintenance of 25 KV GIS Verticals 12.0 33040.0 396480.0 1.8 Maintenance of 33kV/415V Dry Type Transformer Nos. 2.0 4982.6 9965.2 1.9 Maintenance of ACDB Nos. 2.0 2491.28 4982.56 1.1 Maintenance of DCDB Nos. 2.0 2491.28 4982.56 1.11 Maintenance of Battery Charger Nos. 2.0 2491.28 4982.56 1.12 Maintenance of Battery Bank Nos. 4.0 4982.6 19930.4 1.13 Maintenance of Earthing System with its whitewash/paintinG & value writina Nos. 35.0 498.25 17438.75 1.14 Maintenance of Burried Rail Nos. 2.0 4982.6 9965.2 1.15 UPS ( 6KVA ) Nos 4.0 2832.0 11328.0 1.16 UPS ( 5 KVA ) Nos 1.0 2360.0 2360.0 1.17 RTU Nos 13.0 1711.0 22243.0 Preventive Maintenance activities for ASS Equipments 2.1 Maintenance of 33 KV RMU Nos. 27.0 30680.0 828360.0 2.2 Maintenance of Dry type Transformer Nos. 26.0 3278.75 85247.5 2.3 Maintenance of Battery Charger Nos. 13.0 1660.84 21590.92 2.4 Maintenance of Battery Bank Nos. 13.0 1660.84 21590.92 2.5 Maintenance of ACDB Nos. 13.0 1245.64 16193.32 2.6 Maintenance of DCDB Nos. 13.0 1245.64 16193.32 2.7 Maintenance of IGBT Nos 12.0 1793.6 21523.2 2.8 Transportation charge including driver and all fuel charges, 24x7 monthly services up to 2,000 KMs per month (Camper Yoddha), including all maintenance charges. Any additional kilometers beyond 2,000 KMs shall be charged on a pro-rata basis. month 12.0 107022.0 1284264.0 Switching Post & Viaduct Light 3.1 Viaduct Lighting and Power sockets as & when required Nos 1800.0 498.27 896886.0 Schedule 3: Part- Il - Breakdown Maintenance activities 4.1 33kV and 25kV cable end termination jointing work (Jointing kit will be provided by Maha-Metro & Contractor has to provide certified jointer by OEM) Nos 6.0 3597.0 21582.0 4.2 33kV and 25kVcable straight through joint on site (Jointing kit will be provided by Maha-Metro & Contractor has to provide certified jointer by OEM) Nos 6.0 3597.0 21582.0 4.3 Breakdown maintenance for 220 KV GIS By OEM Man -days 5.0 169920.0 849600.0 4.4 Breakdown maintenance for 33 KV GIS by OEM Man -days 5.0 44840.0 224200.0 4.5 Breakdown maintenance for 25 kv GIS by OEM Man -days 5.0 44840.0 224200.0 4.6 Breakdown maintenance for 33 KV RMU by OEM Man -days 5.0 42480.0 212400.0 4.7 Breakdown Maintenance for 25MVA Auxiliarry trafo by OEM Man -days 5.0 70800.0 354000.0 4.8 Breakdown Maintenance for 25MVA Auxiliarry trafo NIFPS by OEM Man -days 5.0 38350.0 191750.0 4.9 Breakdown Maintenance for 10MVA Traction Trafo Man -days 5.0 70800.0 354000.0 4..10 Breakdown Maintenance for 10MVA Traction Trafo NIFPS Man -days 5.0 38350.0 191750.0 4.11 Breakdown Maintenance of 220/33/25 KV CRP/SAS by OEM Mandays 40.0 59472.0 2378880.0 4.12 Breakdown Maintenance of OCC SCADA/RTU by OEM Mandays 20.0 49560.0 991200.0 4.13 Breakdown Maintenance of IGBT by OEM Perday 3.0 17700.0 53100.0 4.14 Replacement & Laying of 33&25kV Cable on Viaduct mtr 20.0 177.0 3540.0 4.15 Replacement & Laying of 33&25kV Cable in ground mtr 20.0 708.0 14160.0 4.16 Laying of Control & LT Cable upto 70 Sq.mm. mtr 300.0 54.28 16284.0 4.17 Hire charge of diesdel Truck-9Tonne for shifting of matrial form store to site( As & when required ) Perday 2.0 5192.0 10384.0 4.18 SF6 Gas multi analyser Perday 1.0 56404.0 56404.0 4.19 Breakdowan maintenance of 33KV DTT (ABB) Perday 2.0 29500.0 59000.0 4..20 Semi skilled worker ( as when required) man/day 35.0 779.95 27298.25 4.21 Supply of 245kV CGL make condenser bushing nos 1.0 1486800.0 1486800.0 4.22 Supply of 36kV porcelain bushing with metal part assembly nos 1.0 318600.0 318600.0 4.23 Supply of 52kV CGL make condenser bushing nos 1.0 791308.0 791308.0 4.24 Supply of 36kV porcelain bushing with metal part assembly nos 1.0 318600.0 318600.0 Total of Schedule 3 19656377.66 Schedule 4: Miscellaneous & consumable items including small tools etc. for PSI SN Description of Work Unit of Measurement Total Qty. of Assets Rate in INR(incl GST) Amount in INR (incl. GST) 1.1 Provisional Sums: Miscellaneous & consumable items and payment shall be made as per actual expenditure Lump Sump 1.0 1770000.0 1770000.0 Total of Schedule 4 Grand Total (Schedule 3 + Schedule 4) 21426377.66 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 28 daysSep 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 29 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender