Drinking Water Supply and Sanitation Local Bodies Closing in 1 days TDR #57240312

Tender For Repair And Maintance Work At New Busstand Hdpe Pipe And Chamber Arrangements In North Zone Thoothukudi City Municipal Corporation

Issued by Local Bodies · Tuticorin, Tamil Nadu
Tender Value
8.60 Lakhs
Estimated cost
Bid Submission
11 Sep 2026
1 days left
EMD
8600
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tuticorin → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintance Work At New Busstand Hdpe Pipe And Chamber Arrangements In North Zone Thoothukudi City Municipal Corporation

BOQ

Name of Work:- Repair and Maintance work at New Busstand HDPE pipe and Chamber Arrangements in North Zone Thoothukudi City Municipal Corporation
Sl. No. Item Description
1Dismantling the existing RCC including all labour and cleaning away from the site etc, complete as per standard specification
2Supply and delivery of 180MM HDPE pipes for sewerage PE 100 PN 6 conforming to IS : 14333/1996 (amended in 2009)
3Earth work excavation and depositing on bank with initial lead of 10m and lift of 2m narrow trenches for laying of pipes for water supply in the following type of soils as directed by the departmental officers sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandy loam and ordinary soil.
4Lowering HDPE pipes and specials to trench and laying to proper grade and alignment and as directed by the TWAD Officers (180mm TO 250mm dia) HDPE Pipe
5Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part 2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by TWAD Board Officers.(180mm)
6Refilling with excavated earth in layer of 30cm watered well rammed and consolidated conforming to standard specification including labour charges as directed by engineering incharge.(for 110mm)
7Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.
8Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means
9Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
10Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steelreinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire)
11Brick work in following Cement Mortar using best quality Fly ash Brick of size 230x110x75mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.
12Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc., complete complying with standard specification and as directed by the departmental officers.
13Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers.50mm thick slab (using 20mm HBGS Jelly) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57240312
AUTHORITY Local Bodies
TENDER VALUE 8.60 Lakhs
LAST DATE 11-09-2026
Authority
Authority Name Municipal Adminitration And Water Supply Department
Work Description Tender for Repair And Maintance Work At New Busstand Hdpe Pipe And Chamber Arrangements In North Zone Thoothukudi City Municipal Corporation
Basic Detail
Tender No E3/2323/2026
Bidding Type Tender
Location
City Tuticorin
State Tamil Nadu
Key Dates
Publish Date 29 Aug 2026
Submission Date 11 Sep 2026
Open Date 11 Sep 2026
Finance
Tender Value 8.60 Lakhs
Tender Fee Ref. Documents
EMD 8600
Exemption Not Available
Document List
a9c1c4e0-cf14-4b24-9441-1755203f755b.html
BOQ_840605.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Sep 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

a9c1c4e0-cf14-4b24-9441-1755203f755b.html

xls

BOQ_840605.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders