Tender For Day To Day Electrical / Mechanical Maintenance At Smq Area Under Ge (Af) Srinagar
Tender Value
30 Lakhs
Estimated cost
Bid Submission
17 Sep 2026
16 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Day To Day Electrical / Mechanical Maintenance At Smq Area Under Ge (Af) Srinagar
BOQ
| Sl. No. | Item Description |
| 1 | Repairing of unserviceable light point, Fan point, socket point 5A / 15A, switches, sockets or regulator, light fixtures any type any type MCBs, replacement of connected wire from ceiling rose to fitting etc in day to day / door to door maintenance and making it serviceable in all respect with provision of adhesive tape and screws & washers etc. Work shall also include to check & removal of breakages in service connection / sub main of houses as and when directed, complete all as specified and directed. (All items such as switch / socket / switch socket combination / light fitting / regulator / MCBs, connection wire etc required to be replaced for this job will be measured seperately and paid under ser Item No 2.00 to 42.00 as supply only.) |
| 2 | Note : (a) Contractors representative/engineer will report to JE E/M/Engr-in-charge daily at forenoon and afternoon to collect routine/urgent works related to internal electric supply till completion of contract. The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, galvanised screws, nuts, bolts, washers etc required to accomplish the job including every type of requisite T&P items to his trades man. All routine/urgent jobs received on job slip will be repaired & got signature of user's and will be deposited to JE E/M with in 24hrs. In case of any delay in attending the complaint more than 8 hrs after handing over of routine and 2 hrs for urgent works, the contractor shall be liable to pay the penalty as described in penalty clause given here as under. |
| 3 | (b) The penalty shall be applicable to the contractor if the delay is noticed by the EIC more than 12 hrs after handing over works of urgent nature to the contractor. The Engr-In-Charge / JE E/M shall handover the slip containing specification of work to the contractor. The contractor shall attend the job immediately and report to Engr-In-Charge within 12hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12 hrs then the facts shall be brought to the notice of the GE / Engr-in-charge and the period for the working to the complaint shall be decided by the GE / EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50.00 (Rs fifty only) per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW –2249 and shall be treated as interim condition of the contract and shall enforceable as and delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer is this regard shall be final and binding. |
| 4 | (c) One Complaints slip to be treated as One Complaint irrespective of No. of Repairs mentioned in the same.(d) Contractor to keep his Electrician ready for Urgent Complaints, During odd hours (0600 Hrs to 0900 Hrs and 1700 Hrs to 2200 Hrs) Other than the Regular complaints during working Hrs (0900 Hrs to 1700 Hrs) (e) Procurement of Security gate passes of the Electrician , will be sole responsibility of the Contractor.(f) If the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the govt. |
| 5 | Supply only Switch piano flush type SP, one way 5 Amps 230 Volt. |
| 6 | Supply only Switch piano flush type SP, one way 15 Amps, 230 Volt. |
| 7 | Supply only Switch socket combination 2 in1, 5 Amps, flush type, 230 Volt. |
| 8 | Supply only Switch socket combination 2 in1, 5 Amps / 15 Amps, flush type, 230 Volt. |
| 9 | Supply only Socket outlet 2 in 1, 5 pin, 5 Amps |
| 10 | Supply only Socket outlet, 2-in-1, 5 pin, 5 and 15 Amps flush |
| 11 | Supply only Switch piano flush type SP, two way 5 Amps 230 Volt. |
| 12 | Supply only Ceiling rose, surface type, 3 terminals. |
| 13 | Supply only Fan electronic dimmers 230 V flush type. |
| 14 | Supply only Angle lamp holder Polycarbonate with back plate. |
| 15 | Supply only Bell push 230 volts, AC |
| 16 | Supply only Call bell ding-dong 230 volts. |
| 17 | Supply only Switch modular type, 1 module, 6 Amps one way. |
| 18 | Supply only Switch modular type, 1 module, 16 Amps one way. |
| 19 | Supply only Socket outlet modular type, 2 module, 3 pin, 6 Amps. |
| 20 | Supply only Socket outlet, modular type, 2 module, 2-in-1, 6 / 16 Amps combined. |
| 21 | Supply only Two way switch modular type, 1 module, 6 Amps. |
| 22 | Supply only Bell push with indicator modular type, 1 module, 6A. |
| 23 | Supply only Fan regulator modular type, 2 module, step type,120 watts. |
| 24 | Supply only MCB Single Pole, 230 Volt, B-Series, Raiting 6 to 32 Amps. |
| 25 | Supply only MCB Single Pole and Neutral , 230 Volt, B-Series, Rating 40 A. |
| 26 | Supply only MCB Single Pole and Neutral, 230 Volt, B-Series, Rating 63A. |
| 27 | Supply only MCB Three Pole and Neutral, 230 Volt, Rating 63 A. |
| 28 | Supply only LED tube light fitting 20 W Batten LED (Warm white / white), Housing made of extruded PC with lumen O/P should not be less than 100 lum / watt. |
| 29 | Supply only LED tube light fitting 10 W Batten LED (Warm white / white), Housing made of extruded PC with lumen O/P should not be less than 100 lum / watt. |
| 30 | Supply only LED 10 watt Bulk Head Light energy saving with IP65 with opal diffuser, pressure die cast aluminium housing. |
| 31 | Supply only Driver for 36 watt LED 600 x 600 Panel light. |
| 32 | Supply only Fan Capacitor 2.5 / 3.15 mfd AC, 230 volt. |
| 33 | Supply only Modular plate 1 module |
| 34 | Supply only Modular plate 2 module |
| 35 | Supply only Modular plate 3 module |
| 36 | Supply only Modular plate 4 module |
| 37 | Supply only Modular plate 6 module |
| 38 | Supply only Modular plate 8 module |
| 39 | Supply only PVC flexible cable twisted two core wire of size 14/76 complete |
| 40 | Supply only 0.50 watt LED lamp retrofit Green / Red colour. |
| 41 | Supply only LED Bulb capacity 10 Watt Warn white. |
| 42 | Supply only LED 06 Watt Recess Mounting, light fitting round / squre type, Housing made of extruded PC with lumen O/P should not be less than 100 lum / watt including electronic driver. |
| 43 | Supply only LED 12 Watt Recess Mounting, light fitting round / squre type, Housing made of extruded PC with lumen O/P should not be less than 100 lum / watt including electronic driver. |
| 44 | Supply only LED 15 Watt Recess Mounting, light fitting round / squre type, Housing made of extruded PC with lumen O/P should not be less than 100 lum / watt including electronic driver. |
| 45 | Supply only LED 15 Watt Surface Mounting light fitting round / squre type, Housing made of extruded PC with lumen O/P should not be less than 100 lum / watt including electronic driver. |
| 46 | Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point ,socket point or power point including fixture and fitting such as switches , ceiling roses, pendants , regulators , sockets , light fitting etc. removing material to store for keeping in safe custody or for taking credit( credit for above items should be made as per conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surface and finishing the surfaces as per existing, complete all as specified and directed. |
| 47 | M&L for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC casing & caping on surface of wall, not less than 25mm width confirming to IS 9537 (Part-III) 1983, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including pressed steel sunken box thickness not less than 1.8 mm with 3 mm thick laminated cover for mounting of piano / flush type switches, switch sockets, fan regulator etc, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate, complete all as specified and directed. (Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green) |
| 48 | All as per Ser item No 44.00 here in above but light / fan point controlled by two way switch 6 amps 240 volts on independent Board. |
| 49 | All as per Ser item No 44.00 here in above but 3 pin 6 Amps socket outlet point controlled by one switch on same board. |
| 50 | All as per Ser item No 44.00 here in above but 3 pin 6 Amps socket outlet point controlled by one switch on independent Board. |
| 51 | All as per Ser item No 44.00 here in before but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 Amps power point. |
| 52 | M&L for concealed Point wiring for one light point controlled by one switch with 1.5 sqmm PVC insulated FRLHS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade in and including not less than 2.00 mm thick and 20 mm dia Non metallic Rigid PVC conduit for Concealed wiring ( ISI marked ) and 1.25 mm thick mild steel terminal boxes (Modular Type) concealed in walls for fixing of modular switches/sockets/ regulator etc along with PVC insulated and unsheathed FRLHS 1.5 Sqmm multi stranded copper conductor cable (green color) as earth lead, & connected to common earth and earthdolly, making good the disturbed surface to match with the existing specification, complete all as specified and directed. |
| 53 | All as per Ser item No 49.00 here in above but light / fan point controlled by two way switch 6 amps 240 volts on independent Board. |
| 54 | All as per Ser item No 49.00 here in above but 3 pin 6 Amps socket outlet point controlled by one switch on same board. |
| 55 | All as per Ser item No 49.00 here in above but 3 pin 6 Amps socket outlet point controlled by one switch on independent Board. |
| 56 | All as per Ser item No 49.00 here in before but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 Amps power point. |
| 57 | S&F Modular switch 1 way, 6 Amp, 230 volts ,1 Module, complete all as specified and directed. |
| 58 | S&F Modular switch 2 way, 6 Amp, 230 volts ,1 Module, complete all as specified and directed. |
| 59 | S&F Modular switch 1 way, 16 Amp, 240 volts ,1 Module, complete all as specified and directed. |
| 60 | S&F modular Socket 6 Amp, 230 volts, 5 Pin universal, 2 Module, complete all as specified and directed. |
| 61 | S&F Modular socket 6/16 Amp, 250 volts, 2 Module, complete all as specified and directed. |
| 62 | S&F modular step type fan regulator suitable for 120 watt 250 volts, 2 Module, complete all as specified and directed. |
| 63 | S&F piano type one way switch 6 Amp, 240 volts, complete all as specified and directed. |
| 64 | S&F piano type two way switch 6 Amp, 240 volts, complete all as specified and directed. |
| 65 | S&F piano type one way switch 16 Amp, 240 volts, complete all as specified and directed. |
| 66 | S&F piano type 6 Amp socket suitable for 240 volts, complete all as specified and directed. |
| 67 | S&F piano type switch 16 Amp suitable for 240 volts, complete all as specified and directed. |
| 68 | S&F piano type step type fan regulator suitable for 120 watt 250 volts, complete all as specified and directed. |
| 69 | S&F Ceiling rose, surface bakelite 65 x 50 mm, 3 terminals fixed on PVC Round Block, complete all as specified and directed. |
| 70 | Sub main wiring with two runs of single core PVC insulated multistranded un-sheathed FRLS cable of size 10.0 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including PVC conduit of requisite dia and accessories) with one run of continuous PVC insulated multistranded unsheathed FRLS cable earth wire of size 10.0 Sqmm (in green volour) including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Note :2 runs of 10 sqmm copper cable & 1 run of 10 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit. |
| 71 | Sub main wiring with two runs of single core PVC insulated multistranded un-sheathed FRLS cable of size 6.0 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including PVC conduit of requisite dia and accessories) with one run of continuous PVC insulated multistranded unsheathed FRLS cable earth wire of size 6.0 Sqmm (in green volour) including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Note :2 runs of 6 sqmm copper cable & 1 run of 6 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit. |
| 72 | Sub main wiring with two runs of single core PVC insulated multistranded un-sheathed FRLS cable of size 4.0 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including PVC conduit of requisite dia and accessories) with one run of continuous PVC insulated multistranded unsheathed FRLS cable earth wire of size 4.0 Sqmm (in green volour) including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Note :2 runs of 4 sqmm copper cable & 1 run of 4 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit. |
| 73 | S&F in repairs Sheet metal enclosure MCB distribution board single pole & neutral, 240 volts, 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar, neutral link and earth bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification, complete all as specified and directed. |
| 74 | S&F in repairs Sheet metal enclosure MCB distribution board single pole & neutral, 240 volts, 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar, neutral link and earth bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification, complete all as specified and directed. |
| 75 | S&F in repairs Sheet metal enclosure MCB distribution board single pole & neutral, 240 volts, 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar, neutral link and earth bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification, complete all as specified and directed. |
| 76 | S&F in repairs sheet metal enclosure distribution board, double door type, as per IEC 61439-3 (CRCA sheet) dust and vermin proof MCB DB, TPN 4 way with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification, complete all as specified and directed. |
| 77 | S&F in repairs sheet metal enclosure epoxy powder coated or polysterene insulated material double door type, vertical triple pole & neutral (VTPN) 4 Way with in built MCCB 63 Amps, 16 KA with 200 Amp rated bus bar flush /surface mounting double door, complete all as specified and directed. |
| 78 | S&F in repairs MCB of single poles and current carrying capacity 6 to 32 Amp, 240V, 10 KA 'B' curve, in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. |
| 79 | S&F in repairs MCB single pole and neutral ISI marked `B' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 40 Amps 10 KA breaking capacity etc all as specified and directed. |
| 80 | S&F in repairs MCB single pole and neutral ISI marked `B' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 63 Amps 10 KA breaking capacity etc all as specified and directed. |
| 81 | S&F in repairs MCB triple pole and neutral ISI marked, C series, working on 415 volts 50HZ AC supply for incoming and outgoing controlling system capacity 63 Amps, 10 KA breaking capacity, complete all as specified and directed. |
| 82 | S&F in repairs 100 Amps MCCB, 3 pole 16 KA working on 415 Volts 50 HZ AC supply, complete all as specified and directed. |
| 83 | M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 metre deep below ground level) vertically, with top edge of the plate not less than 1.25 mtr below normal ground level, connected to galvanized iron wire 4mm dia by means of nuts, bolts, washers of GI steel all as shown on electrical plate No 3 of MES Schedule Part I connected to earthing test point and testing on completion with and including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment/substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm gradedcrushed stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 15 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe including taking down old one, complete all as specified and directed.Note: (i) The unit rate includes main earthing lead/strip from earth electrode to test point up to 7.5 meter (ii) In case measured value of earth resistance is recorded more than 1.0 ohms then the earthing shall be re done by the contractor without any extra cost to the department. |
| 84 | Supply, laying or Fixing or passing through pipe 1100 volts grade heavy duty cable with PVC insulated, stranded aluminium conductor served with an inner sheating of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 6 Sqmm 2 core nomial cross section in service connection including taking down of oldunserviceable cable, complete all as directed by Engr-in-charge. |
| 85 | S&F in repairs 25mm dia GI tubing, light grade, with all fittings fixed on walls / poles, laid in trenches for protection of cable, complete all as specified and directed. |
| 86 | S&F in repairs building security light LED 25 Watt with Lumen O/P 1800 with driver with rated voltage 240 V, 50Hz, including mounting GI (made out of 25 mm dia light grade pipe 0.8m bent two shape including FI clamps nut bolts etc.), complete all as specified and directed. |
| 87 | S&F in repairs LED decorative wall light fixture made up of polycarbonate and including LED 15/18 W Lamp and making all connection using flexible cable of suitable size from ceiling rose to fitting, complete all as specified and directed. |
| 88 | S&F in repairs decorative wall mounting light fitting, SS finish fixture with opal glass diffuser including 12 W retrofit LED bulb and making all connection using flexible cable of suitable size from ceiling rose to fitting, complete all as specified and directed. |
| 89 | S&F in repairs decorative wall light made up of high grade engineering plastic material including retrofit LED Bulb 10 watt and making all connection using flexible cable of suitable size from ceiling rose to fitting, complete all as specified and directed. |
| 90 | S&F in repairs decorative wall light fitting, Champagne gold finish fixture with plastic body including 12 Watt retrofit LED Bulb and making all connection using flexible cable of suitable size from ceiling rose to fitting, complete all as specified and directed. |
| 91 | S&F in repairs decorative wall light fiiting, fixture made up of polycarbonate, including 12 Watt retrofit warm LED Bulb and making all connection using flexible cable of suitable size from ceiling rose to fitting, complete all as specified and directed. |
| 92 | S&F in repairs metal clad plug & socket board single pole and neutral enclosure with 3 pin and earth plugs and socket complete with one single pole 20 Amps MCB, 415 Volts, C type, complete all as specified and directed. |
| 93 | S&F in repairs 10 Watt 2 way modern cylinder light round shape warm white shade colour, 220 Volts (AC) waterproof up light down light wall mount, removable fixture type metal enclosure material, complete all as specified and directed. |
| 94 | Deduction to be made from BOQ for Schedule 'A' Part-II (Credit Schedule from dismantling / taking down items) worth Rs 80,405.00 during AOC. (Note :- Tenderers shall not quote for this Schedule) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 17, 2026
17:00 IST