Educational and Research Institute Government Departments Closing in 7 days TDR #57231284

Bids Are invited for Laparoscopic Hand Instruments Set - Reducer 11/5 Mm , Clickline Plastic Handle, Style Ratchet, With Larger Contact Area At The Finger Ring, With Connector Pin For Unipolar Coagulation , Three Piece Laparoscopic Croce-Olmi Graspin

Issued by Government Departments · Nadia, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Sep 2026
7 days left
EMD
1.32 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nadia → West Bengal
EMD Exemption
Available
Quantity
1

Project Description

Bids Are invited for Laparoscopic Hand Instruments Set - Reducer 11/5 Mm , Clickline Plastic Handle, Style Ratchet, With Larger Contact Area At The Finger Ring, With Connector Pin For Unipolar Coagulation , Three Piece Laparoscopic Croce-Olmi Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet Metal Outer Sheath, Insulated Forceps Insert,Three Part Dismantel. , Three Piece Laparoscopic Croce-Olmi Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, With Ratchet & Metal Outer Sheath, Insulated Forceps Insert,Three Part Dismantel. , Three Piece Laparoscopic Croce-Olmi Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 43 Cm Consisting Of: Plastic Handle, Without Ratchet Metal Outer Sheath, Insulated Forceps Insert,Three Part Dismantel. , Three Piece Laparoscopic Croce-Olmi Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 43 Cm Consisting Of: Plastic Handle, With Ratchet Metal Outer Sheath, Insulated Forceps Insert,Three Part Dismantel. , Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Uni Polar Coagu- Lation, Size 5 Mm, Length 3 6 Cm, Right Angled, Double Action Jaws, Consisting Of: Plastic Handle, Wit Hout Ratchet, With Larger Contact Area , Three Piece Laparoscopic Kelly Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 43 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. , Three Piece Laparoscopic Kelly Dissecting And Grasping Forcep, Rotating, With Connector Pin Fo R Unipolar Coagulation, Size 5 Mm, Lengt H 36 Cm, Long, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area , Three Piece Laparoscopic Reddick-Olsen Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Heavy, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Outer Tube Insulated Forceps Insert,Three Part Dismantel. , Three Piece Laparoscopic Reddick-Olsen Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 43 Cm, Heavy, Double Action Jaws, Consisting Of: Plastic Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert,Three Part Dismantel. , Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm And Length 43 Cm, With Alligator Double-Action Jaws, Consisting Of A Plastic Handle Without Ratchet With A Larger Contact Area, An Insulated Outer Tube, And A Forceps Insert. , Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm And Length 43 Cm, With Alligator Double-Action Jaws, Consisting Of A Plastic Handle With Ratchet With A Larger Contact Area, An Insulated Outer Tube, And A Forceps Insert. , Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Fenestrated, Single Action Jaws, Having An Ergonomic Metal Handle With Plastic Finger Rings With Larger Contact Area At The Finger Ring To Avoid Pressure Sores , Debakey Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Atraumatic, Double-Action Jaws, Size 5 Mm, Length 36 Cm, Consisting Of A Plastic Handle With Ratchet And A Larger Contact Area, An Insulated Outer Tube, And A Forceps Insert. , The Electrode Should Be L-Shaped And Suitable For Coagulation And Dissection In Laparoscopic Procedures. It Should Have A Diameter Of 5 Mm And A Working Length Of 43 Cm. The Instrument Should Be Compatible With Standard Unipolar Electrosurgical Units And Designed For Precise Tissue Dissection And Effective Coagulation. , The Retractor Should Be Of Cuschieri Type, Suitable For Laparoscopic Procedures, With A Diameter Of 5 Mm And A Working Length Of 36 Cm. It Should Consist Of An Insert, An Outer Sheath, And A Compatible Handle, Designed To Provide Effective Retraction And Optimal Visualization During Surgical Procedures. , The Retractor Should Be Of Cuschieri Type With A Large Contact Surface, Suitable For Laparoscopic Procedures, With A Diameter Of 10 Mm And A Working Length Of 36 Cm. It Should Consist Of An Insert, An Outer Sheath, And A Compatible Handle, Designed To Provide Stable Tissue Retraction And Enhanced Surgical Field Exposure. , Dismantling Fan Retractor, Distendable, Size 10 Mm, Length 36 Cm. , The Needle Holder Should Be Of Koh Macro Type With An Ergonomic Axial Handle And A Disengageable Ratchet, With Ratchet Release On The Right Side. It Should Have Straight Jaws With Tungsten Carbide Inserts For Enhanced Durability And Grip. The Instrument Should Have A Diameter Of 5 Mm And A Working Length Of 43 Cm, Suitable For Laparoscopic Suturing Procedures. , The Needle Holder Should Be Of Koh Macro Type With Tungsten Carbide Inserts And An Ergonomic Pistol Handle With A Disengageable Ratchet, With Ratchet Positioned On The Left Side. It Should Have Jaws Curved To The Left, With A Diameter Of 5 Mm And A Working Length Of 33 Cm. The Instrument Should Be Suitable For Use With Suture Materials Ranging From 0-0 To 7/0 And Compatible With Needle Types Such As Bv, Sh, Or Ct-1, Ensuring Precise And Secure Suturing In Laparoscopic Procedures. , The Knot Tier Should Be Suitable For Extracorporeal Knotting In Laparoscopic Procedures, With A Diameter Of 5 Mm And A Working Length Of 36 Cm. The Instrument Should Be Designed To Facilitate Smooth And Secure Knot Advancement, Ensuring Precise Ligation And Ease Of Handling During Minimally Invasive Surgeries. , Berci Fascial Closure Instrument For Sub Cutaneous Ligature Of Trocar Incisions, Ening , Hook Scissors, Rotating Type, Size 5 Mm With A Working Length Of Approximately 43 Cm, Featuring Single-Action Jaws For Precise Dissection, Comprising A Plastic Handle Without Ratchet With A Large Contact Area, Insulated Outer Tube, And Hook Scissors Insert. , Grasping Forceps Rotating, With A Connector Pin For Unipolar Coagulation. It Should Have A Diameter Of 5 Mm And A Working Length Of 36 Cm, With Single-Action Jaws Featuring Multiple Teeth And A Jaw Width Of Approximately 4.8 Mm For Secure Tissue Handling. The Instrument Should Consist Of A Plastic Handle Without Ratchet With A Larger Contact Area, An Insulated Outer Tube, And A Compatible Forceps Insert, Ensuring Precision And Reliability In Laparoscopic Procedures. , Grasping Forceps Rotating, With A Connector Pin For Unipolar Coagulation. It Should Have A Diameter Of 5 Mm And A Working Length Of 43 Cm, With Single-Action Jaws Featuring Multiple Teeth And A Jaw Width Of Approximately 4.8 Mm For Secure Tissue Handling. The Instrument Should Consist Of A Plastic Handle Without Ratchet With A Larger Contact Area, An Insulated Outer Tube, And A Compatible Forceps Insert, Ensuring Precision And Reliability In Laparoscopic Procedures. , The Trocar Should Have A Pyramidal Tip And Be Provided With An Insufflation Stopcock For Controlled Gas Flow During Laparoscopic Procedures. It Should Have A Diameter Of 13.5 Mm And A Working Length Of 15 Cm, With Appropriate Color Coding For Easy Identification. The Trocar System Should Consist Of A Cannula, Trocar Obturator, And A Multifunctional Valve, Ensuring Secure Access, Minimal Gas Leakage, And Reliable Performance During Surgery. , The Trocar Should Have A Pyramidal Tip And Be Equipped With An Insufflation Stopcock For Controlled Gas Flow During Laparoscopic Procedures. It Should Have A Diameter Of 15 Mm And A Working Length Of 12 Cm. The System Should Consist Of A Cannula Without Valve, A Trocar Obturator, And An Automatic Valve, Ensuring Secure Access, Effective Sealing, And Minimal Gas Leakage During Surgical Procedures. , The Trocar Should Be Specifically Designed For Use In Obese Patients, With A Diameter Of 6 Mm And Appropriate Color Coding For Easy Identification. It Should Feature A Pyramidal Tip For Smooth And Controlled Entry And Be Provided With An Insufflation Stopcock For Gas Management. The System Should Include A Cannula Without Valve With An Extended Working Length Of Approximately 15 Cm, A Trocar Obturator, And A Multifunctional Valve, Ensuring Secure Access, Effective Sealing, And Reliable Performance During Laparoscopic Procedures. , Nathanson Liver Retractor, Small Surface Area, Dia 5 Mm. , Nathanson Liver Retractor, Medium Surface Area, Dia 5 Mm. , Nathanson Liver Retractor, Large Surface Area, Dia 5 Mm. , Articulated Stand , With Rotation Socket, To Cl On The Operating Table And Cl Ing Jaw, Metal, Cl Ing Range 16.5 Up To 23 Mm, , The Rotation Socket Should Be Designed For Secure Cl Ing Onto The Operating Table And Should Be Compatible With Standard Rails. It Should Be Provided With A Pre-Mounted Butterfly Nut For Easy Fixation And Include A Lateral Cl Ing Mechanism To Allow Precise Height And Angle Adjustment Of The Articulated Stand. The Design Should Ensure Stable Positioning, Ease Of Use, And Reliable Performance During Surgical Procedures. , The Cl Ing Jaw Should Be Made Of Metal And Provide A Cl Ing Range Of Approximately 4.8 Mm To 12.5 Mm. It Should Be Equipped With A Quick-Release Coupling System (Male Type) Compatible With Kslock Or Equivalent Mechanism. The Device Should Be Suitable For Use With Instrument And Telescope Sheaths, Ensuring Secure Fixation, Quick Attachment And Detachment, And Stable Performance During Surgical Procedures. , Debakey Grasping Forceps Rotating Type, With A Connector Pin For Unipolar Coagulation. It Should Be Atraumatic With Double-Action Jaws, Having A Diameter Of 5 Mm And A Working Length Of 43 Cm. The Instrument Should Consist Of A Plastic Handle Without Ratchet With A Larger Contact Area, An Insulated Outer Tube, And A Compatible Forceps Insert, Ensuring Precise, Atraumatic Tissue Handling And Reliability In Laparoscopic Procedures. , Dissecting And Grasping Forceps Rotating, With A Connector Pin For Unipolar Coagulation. It Should Have Double-Action Jaws Designed For Effective Tissue Dissection And Grasping, With Atraumatic Or Serrated Jaw Profile As Per Clinical Requirement. The Instrument Should Be Of 5 Mm Diameter With A Working Length Of Approximately 36 Cm. It Should Include An Ergonomic Handle With Ratchet Mechanism For Secure Grip, An Insulated Outer Tube, And A Compatible Forceps Insert. , The Instrument Should Be A Modular Dissecting Electrode System Suitable For Laparoscopic Procedures, With An L-Shaped Electrode Tip For Precise Dissection And Coagulation. It Should Be Compatible With Standard Unipolar Electrosurgical Units And Provided With A Connector Pin For Unipolar Coagulation. The Instrument Should Have A Diameter Of 5 Mm And A Working Length Of Approximately 36 Cm. It Should Consist Of An Insulated Outer Tube For Patient Safety, An Ergonomic Plastic Handle For Comfortable Grip And Control, And A Detachable L-Shaped Electrode Tips. The Design Should Ensure Effective Energy Transmission, Precise Tissue Dissection, And Safe, Reliable Performance During Minimally Invasive Surgeries. , The Electrodes Should Be L-Shaped And Suitable For Use In Laparoscopic Dissection And Coagulation Procedures. They Should Be Compatible With Standard Unipolar Electrosurgical Instruments And Designed To Ensure Precise Energy Delivery And Effective Tissue Handling. The Electrodes Should Be Supplied In A Sterile Or Non-Sterile Package Of Six Units, Suitable For Repeated Or Single-Use Applications As Per Clinical Requirements. , The Light Adapter Should Have A Diameter Of 4.8 Mm And Be 90° Angled, With A Freely Rotatable Design For Ease Of Handling. It Should Be Compatible With Standard Laparoscopic Scopes And Ensure Secure And Efficient Light Transmission During Surgical Procedures. , The Needle Holder Should Be Of Koh Type With A Dismantlable Design, Featuring An Ergonomic Pistol Grip Handle With A Disengageable Ratchet And Ratchet Release On The Left Side. It Should Have Straight Jaws With Tungsten Carbide Inserts For Enhanced Durability And Secure Grip. The Instrument Should Have A Diameter Of 5 Mm And A Working Length Of 33 Cm. It Should Consist Of A Handle, An Outer Tube, And A Compatible Insert, Ensuring Precision, Reliability, And Ease Of Use During Laparoscopic Suturing Procedures. , Grasping Forceps Should Be Of Debakey Type, Rotating, With A Connector Pin For Unipolar Coagulation. It Should Have A Diameter Of 5 Mm And A Working Length Of 36 Cm, With Narrow And Curved Atraumatic Double-Action Jaws For Precise Tissue Handling. The Instrument Should Consist Of A Plastic Handle With A Hemostat-Style Ratchet And A Larger Contact Area, An Insulated Outer Tube, And A Compatible Forceps Insert, Ensuring Controlled Grip, Precision, And Reliability In Laparoscopic Procedures. , Coagulating And Dissecting Electrode, L-Shaped, With Suction Channel, The Electrode Should Be L-Shaped And Suitable For Laparoscopic Coagulation And Dissection, With An Integrated Channel For Use With Suction And Irrigation Handles. It Should Have A Diameter Of 5 Mm And A Working Length Of 36 Cm. The Instrument Should Be Compatible With Standard Unipolar Electrosurgical Units And Designed To Enable Simultaneous Tissue Dissection, Coagulation, And Fluid Management, Ensuring Efficiency And Precision During Minimally Invasive Procedures. , The Irrigation Adaptor Should Be Suitable For Use With 5 Mm Coagulating And Dissecting Electrodes Equipped With A Suction Channel. It Should Be Provided With A Standard Luer-Lock Connector For Secure And Leak-Proof Connection To Irrigation Systems. The Adaptor Should Be Designed To Ensure Efficient Fluid Delivery, Compatibility With Standard Laparoscopic Instruments, And Reliable Performance During Surgical Procedures. , The Trocar Should Have A Pyramidal Tip And Be Equipped With An Insufflation Stopcock For Controlled Gas Flow During Laparoscopic Procedures. It Should Have A Diameter Of 11 Mm And A Working Length Of 10.5 Cm. The System Should Consist Of A Cannula Without Valve, A Trocar Obturator, And An Automatic Valve, Ensuring Secure Access, Effective Sealing, And Minimal Gas Leakage During Surgical Procedures. , The Trocar Should Have A Pyramidal Tip And Be Equipped With An Insufflation Stopcock For Controlled Gas Flow During Laparoscopic Procedures. It Should Have A Diameter Of 6 Mm And A Working Length Of 10.5 Cm. The System Should Consist Of A Cannula Without Valve, A Trocar Obturator, And An Automatic Valve, Ensuring Secure Access, Effective Sealing, And Minimal Gas Leakage During Surgical Procedures. , Fiber Optic Light Cable Diameter 4.8 Mm Length 300 Cm With Straight Connector Extremely Heat- Resi Stant Enhanced Light Transmission

BOQ

Sl. No. Item TitleItem Description
1Reducer 11/5 mmReducer 11/5 mm
2CLICKLINE Plastic Handle, style ratchet, with larger contact area at the finger ring, with connector pin for unipolar coagulationCLICKLINE Plastic Handle, style ratchet, with larger contact area at the finger ring, with connector pin for unipolar coagulation
3Three piece laparoscopic CROCE-OLMI Grasping Forceps, rotating, dismantling, insulated, with connector pin for unipolar coagulation, with LUER-Lock connector for cleaning, single action jaws, atraumatic, fenestrated, curved, size 5 mm, length 36 cm consisting of: Plastic Handle, without ratchet Metal Outer Sheath, insulated Forceps Insert,three part dismantel.Three piece laparoscopic CROCE-OLMI Grasping Forceps, rotating, dismantling, insulated, with connector pin for unipolar coagulation, with LUER-Lock connector for cleaning, single action jaws, atraumatic, fenestrated, curved, size 5 mm, length 36 cm consisting of: Plastic Handle, without ratchet Metal Outer Sheath, insulated Forceps Insert,three part dismantel.
4Three piece laparoscopic CROCE-OLMI Grasping Forceps, rotating, dismantling, insulated, with connector pin for unipolar coagulation, with LUER-Lock connector for cleaning, single action jaws, atraumatic, fenestrated, curved, size 5 mm, length 36 cm consisting of: Plastic Handle, with ratchet & Metal Outer Sheath, insulated Forceps Insert,three part dismantel.Three piece laparoscopic CROCE-OLMI Grasping Forceps, rotating, dismantling, insulated, with connector pin for unipolar coagulation, with LUER-Lock connector for cleaning, single action jaws, atraumatic, fenestrated, curved, size 5 mm, length 36 cm consisting of: Plastic Handle, with ratchet & Metal Outer Sheath, insulated Forceps Insert,three part dismantel.
5Three piece laparoscopic CROCE-OLMI Grasping Forceps, rotating, dismantling, insulated, with connector pin for unipolar coagulation, with LUER-Lock connector for cleaning, single action jaws, atraumatic, fenestrated, curved, size 5 mm, length 43 cm consisting of: Plastic Handle, without ratchet Metal Outer Sheath, insulated Forceps Insert,Three part dismantel.Three piece laparoscopic CROCE-OLMI Grasping Forceps, rotating, dismantling, insulated, with connector pin for unipolar coagulation, with LUER-Lock connector for cleaning, single action jaws, atraumatic, fenestrated, curved, size 5 mm, length 43 cm consisting of: Plastic Handle, without ratchet Metal Outer Sheath, insulated Forceps Insert,Three part dismantel.
6Three piece laparoscopic CROCE-OLMI Grasping Forceps, rotating, dismantling, insulated, with connector pin for unipolar coagulation, with LUER-Lock connector for cleaning, single action jaws, atraumatic, fenestrated, curved, size 5 mm, length 43 cm consisting of: Plastic Handle, with ratchet Metal Outer Sheath, insulated Forceps Insert,Three part dismantel.Three piece laparoscopic CROCE-OLMI Grasping Forceps, rotating, dismantling, insulated, with connector pin for unipolar coagulation, with LUER-Lock connector for cleaning, single action jaws, atraumatic, fenestrated, curved, size 5 mm, length 43 cm consisting of: Plastic Handle, with ratchet Metal Outer Sheath, insulated Forceps Insert,Three part dismantel.
7Three piece laparoscopic Dissecting and Grasping Forceps, rotating, with connector pin for uni polar coagu- lation, size 5 mm, length 3 6 cm, right angled, double action jaws, consisting of: Plastic Handle, wit hout ratchet, with larger contact areaThree piece laparoscopic Dissecting and Grasping Forceps, rotating, with connector pin for uni polar coagu- lation, size 5 mm, length 3 6 cm, right angled, double action jaws, consisting of: Plastic Handle, wit hout ratchet, with larger contact area
8Three piece laparoscopic KELLY Dissecting and Grasping Forceps, rotating, with connector pin for unipolar coagulation, size 5 mm, length 43 cm, double action jaws, consisting of: Plastic Handle, without ratchet Outer Tube, insulated Forceps Insert, Three part dismantel.Three piece laparoscopic KELLY Dissecting and Grasping Forceps, rotating, with connector pin for unipolar coagulation, size 5 mm, length 43 cm, double action jaws, consisting of: Plastic Handle, without ratchet Outer Tube, insulated Forceps Insert, Three part dismantel.
9Three piece laparoscopic KELLY Dissecting and Grasping Forcep, rotating, with connector pin fo r unipolar coagulation, size 5 mm, lengt h 36 cm, long, double action jaws, consisting of: Plastic Handle, without ratchet, with larger contact areaThree piece laparoscopic KELLY Dissecting and Grasping Forcep, rotating, with connector pin fo r unipolar coagulation, size 5 mm, lengt h 36 cm, long, double action jaws, consisting of: Plastic Handle, without ratchet, with larger contact area
10Three piece laparoscopic REDDICK-OLSEN Dissecting and Grasping Forceps, rotating, with connector pin for unipolar coagulation, size 5 mm, length 36 cm, heavy, double action jaws, consisting of: Plastic Handle, without ratchet, Outer Tube insulated Forceps Insert,Three part dismantel.Three piece laparoscopic REDDICK-OLSEN Dissecting and Grasping Forceps, rotating, with connector pin for unipolar coagulation, size 5 mm, length 36 cm, heavy, double action jaws, consisting of: Plastic Handle, without ratchet, Outer Tube insulated Forceps Insert,Three part dismantel.
11Three piece laparoscopic REDDICK-OLSEN Dissecting and Grasping Forceps, rotating, with connector pin for unipolar coagulation, size 5 mm, length 43 cm, heavy, double action jaws, consisting of: Plastic Handle, with MANHES style ratchet Outer Tube, insulated Forceps Insert,Three part dismantel.Three piece laparoscopic REDDICK-OLSEN Dissecting and Grasping Forceps, rotating, with connector pin for unipolar coagulation, size 5 mm, length 43 cm, heavy, double action jaws, consisting of: Plastic Handle, with MANHES style ratchet Outer Tube, insulated Forceps Insert,Three part dismantel.
12Dissecting and Grasping Forceps, rotating, with connector pin for unipolar coagulation, size 5 mm and length 43 cm, with alligator double-action jaws, consisting of a plastic handle without ratchet with a larger contact area, an insulated outer tube, and a forceps insert.Dissecting and Grasping Forceps, rotating, with connector pin for unipolar coagulation, size 5 mm and length 43 cm, with alligator double-action jaws, consisting of a plastic handle without ratchet with a larger contact area, an insulated outer tube, and a forceps insert.
13Dissecting and Grasping Forceps, rotating, with connector pin for unipolar coagulation, size 5 mm and length 43 cm, with alligator double-action jaws, consisting of a plastic handle with ratchet with a larger contact area, an insulated outer tube, and a forceps insert.Dissecting and Grasping Forceps, rotating, with connector pin for unipolar coagulation, size 5 mm and length 43 cm, with alligator double-action jaws, consisting of a plastic handle with ratchet with a larger contact area, an insulated outer tube, and a forceps insert.
14Three piece laparoscopic Grasping Forceps, rotating, with connector pin for unipolar coagulation, size 5 mm, length 36 cm, atraumatic, fenestrated, single action jaws, having an ergonomic metal handle with plastic finger rings with larger contact area at the finger ring to avoid pressure soresThree piece laparoscopic Grasping Forceps, rotating, with connector pin for unipolar coagulation, size 5 mm, length 36 cm, atraumatic, fenestrated, single action jaws, having an ergonomic metal handle with plastic finger rings with larger contact area at the finger ring to avoid pressure sores
15DeBAKEY Grasping Forceps, rotating, with connector pin for unipolar coagulation, atraumatic, double-action jaws, size 5 mm, length 36 cm, consisting of a plastic handle with ratchet and a larger contact area, an insulated outer tube, and a forceps insert.DeBAKEY Grasping Forceps, rotating, with connector pin for unipolar coagulation, atraumatic, double-action jaws, size 5 mm, length 36 cm, consisting of a plastic handle with ratchet and a larger contact area, an insulated outer tube, and a forceps insert.
16The electrode should be L-shaped and suitable for coagulation and dissection in laparoscopic procedures. It should have a diameter of 5 mm and a working length of 43 cm. The instrument should be compatible with standard unipolar electrosurgical units and designed for precise tissue dissection and effective coagulation.The electrode should be L-shaped and suitable for coagulation and dissection in laparoscopic procedures. It should have a diameter of 5 mm and a working length of 43 cm. The instrument should be compatible with standard unipolar electrosurgical units and designed for precise tissue dissection and effective coagulation.
17The retractor should be of CUSCHIERI type, suitable for laparoscopic procedures, with a diameter of 5 mm and a working length of 36 cm. It should consist of an insert, an outer sheath, and a compatible handle, designed to provide effective retraction and optimal visualization during surgical procedures.The retractor should be of CUSCHIERI type, suitable for laparoscopic procedures, with a diameter of 5 mm and a working length of 36 cm. It should consist of an insert, an outer sheath, and a compatible handle, designed to provide effective retraction and optimal visualization during surgical procedures.
18The retractor should be of CUSCHIERI type with a large contact surface, suitable for laparoscopic procedures, with a diameter of 10 mm and a working length of 36 cm. It should consist of an insert, an outer sheath, and a compatible handle, designed to provide stable tissue retraction and enhanced surgical field exposure.The retractor should be of CUSCHIERI type with a large contact surface, suitable for laparoscopic procedures, with a diameter of 10 mm and a working length of 36 cm. It should consist of an insert, an outer sheath, and a compatible handle, designed to provide stable tissue retraction and enhanced surgical field exposure.
19Dismantling Fan Retractor, distendable, size 10 mm, length 36 cm.Dismantling Fan Retractor, distendable, size 10 mm, length 36 cm.
20The needle holder should be of KOH macro type with an ergonomic axial handle and a disengageable ratchet, with ratchet release on the right side. It should have straight jaws with tungsten carbide inserts for enhanced durability and grip. The instrument should have a diameter of 5 mm and a working length of 43 cm, suitable for laparoscopic suturing procedures.The needle holder should be of KOH macro type with an ergonomic axial handle and a disengageable ratchet, with ratchet release on the right side. It should have straight jaws with tungsten carbide inserts for enhanced durability and grip. The instrument should have a diameter of 5 mm and a working length of 43 cm, suitable for laparoscopic suturing procedures.
21The needle holder should be of KOH macro type with tungsten carbide inserts and an ergonomic pistol handle with a disengageable ratchet, with ratchet positioned on the left side. It should have jaws curved to the left, with a diameter of 5 mm and a working length of 33 cm. The instrument should be suitable for use with suture materials ranging from 0-0 to 7/0 and compatible with needle types such as BV, SH, or CT-1, ensuring precise and secure suturing in laparoscopic procedures.The needle holder should be of KOH macro type with tungsten carbide inserts and an ergonomic pistol handle with a disengageable ratchet, with ratchet positioned on the left side. It should have jaws curved to the left, with a diameter of 5 mm and a working length of 33 cm. The instrument should be suitable for use with suture materials ranging from 0-0 to 7/0 and compatible with needle types such as BV, SH, or CT-1, ensuring precise and secure suturing in laparoscopic procedures.
22The knot tier should be suitable for extracorporeal knotting in laparoscopic procedures, with a diameter of 5 mm and a working length of 36 cm. The instrument should be designed to facilitate smooth and secure knot advancement, ensuring precise ligation and ease of handling during minimally invasive surgeries.The knot tier should be suitable for extracorporeal knotting in laparoscopic procedures, with a diameter of 5 mm and a working length of 36 cm. The instrument should be designed to facilitate smooth and secure knot advancement, ensuring precise ligation and ease of handling during minimally invasive surgeries.
23BERCI Fascial Closure Instrument for sub cutaneous ligature of trocar incisions, eningBERCI Fascial Closure Instrument for sub cutaneous ligature of trocar incisions, ening
24Hook Scissors, rotating type, size 5 mm with a working length of approximately 43 cm, featuring single-action jaws for precise dissection, comprising a plastic handle without ratchet with a large contact area, insulated outer tube, and hook scissors insert.Hook Scissors, rotating type, size 5 mm with a working length of approximately 43 cm, featuring single-action jaws for precise dissection, comprising a plastic handle without ratchet with a large contact area, insulated outer tube, and hook scissors insert.
25Grasping Forceps rotating, with a connector pin for unipolar coagulation. It should have a diameter of 5 mm and a working length of 36 cm, with single-action jaws featuring multiple teeth and a jaw width of approximately 4.8 mm for secure tissue handling. The instrument should consist of a plastic handle without ratchet with a larger contact area, an insulated outer tube, and a compatible forceps insert, ensuring precision and reliability in laparoscopic procedures.Grasping Forceps rotating, with a connector pin for unipolar coagulation. It should have a diameter of 5 mm and a working length of 36 cm, with single-action jaws featuring multiple teeth and a jaw width of approximately 4.8 mm for secure tissue handling. The instrument should consist of a plastic handle without ratchet with a larger contact area, an insulated outer tube, and a compatible forceps insert, ensuring precision and reliability in laparoscopic procedures.
26Grasping Forceps rotating, with a connector pin for unipolar coagulation. It should have a diameter of 5 mm and a working length of 43 cm, with single-action jaws featuring multiple teeth and a jaw width of approximately 4.8 mm for secure tissue handling. The instrument should consist of a plastic handle without ratchet with a larger contact area, an insulated outer tube, and a compatible forceps insert, ensuring precision and reliability in laparoscopic procedures.Grasping Forceps rotating, with a connector pin for unipolar coagulation. It should have a diameter of 5 mm and a working length of 43 cm, with single-action jaws featuring multiple teeth and a jaw width of approximately 4.8 mm for secure tissue handling. The instrument should consist of a plastic handle without ratchet with a larger contact area, an insulated outer tube, and a compatible forceps insert, ensuring precision and reliability in laparoscopic procedures.
27The trocar should have a pyramidal tip and be provided with an insufflation stopcock for controlled gas flow during laparoscopic procedures. It should have a diameter of 13.5 mm and a working length of 15 cm, with appropriate color coding for easy identification. The trocar system should consist of a cannula, trocar obturator, and a multifunctional valve, ensuring secure access, minimal gas leakage, and reliable performance during surgery.The trocar should have a pyramidal tip and be provided with an insufflation stopcock for controlled gas flow during laparoscopic procedures. It should have a diameter of 13.5 mm and a working length of 15 cm, with appropriate color coding for easy identification. The trocar system should consist of a cannula, trocar obturator, and a multifunctional valve, ensuring secure access, minimal gas leakage, and reliable performance during surgery.
28The trocar should have a pyramidal tip and be equipped with an insufflation stopcock for controlled gas flow during laparoscopic procedures. It should have a diameter of 15 mm and a working length of 12 cm. The system should consist of a cannula without valve, a trocar obturator, and an automatic valve, ensuring secure access, effective sealing, and minimal gas leakage during surgical procedures.The trocar should have a pyramidal tip and be equipped with an insufflation stopcock for controlled gas flow during laparoscopic procedures. It should have a diameter of 15 mm and a working length of 12 cm. The system should consist of a cannula without valve, a trocar obturator, and an automatic valve, ensuring secure access, effective sealing, and minimal gas leakage during surgical procedures.
29The trocar should be specifically designed for use in obese patients, with a diameter of 6 mm and appropriate color coding for easy identification. It should feature a pyramidal tip for smooth and controlled entry and be provided with an insufflation stopcock for gas management. The system should include a cannula without valve with an extended working length of approximately 15 cm, a trocar obturator, and a multifunctional valve, ensuring secure access, effective sealing, and reliable performance during laparoscopic procedures.The trocar should be specifically designed for use in obese patients, with a diameter of 6 mm and appropriate color coding for easy identification. It should feature a pyramidal tip for smooth and controlled entry and be provided with an insufflation stopcock for gas management. The system should include a cannula without valve with an extended working length of approximately 15 cm, a trocar obturator, and a multifunctional valve, ensuring secure access, effective sealing, and reliable performance during laparoscopic procedures.
30Nathanson liver retractor, small surface area, dia 5 mm.Nathanson liver retractor, small surface area, dia 5 mm.
31Nathanson liver retractor, Medium surface area, dia 5 mm.Nathanson liver retractor, Medium surface area, dia 5 mm.
32Nathanson liver retractor, Large surface area, dia 5 mm.Nathanson liver retractor, Large surface area, dia 5 mm.
33Articulated Stand , with ROTATION SOCKET, TO CLAMP ON THE OPERATING TABLE and CLAMPING JAW, METAL, CLAMPING RANGE 16.5 UP TO 23 MM,Articulated Stand , with ROTATION SOCKET, TO CLAMP ON THE OPERATING TABLE and CLAMPING JAW, METAL, CLAMPING RANGE 16.5 UP TO 23 MM,
34The rotation socket should be designed for secure clamping onto the operating table and should be compatible with standard rails. It should be provided with a pre-mounted butterfly nut for easy fixation and include a lateral clamping mechanism to allow precise height and angle adjustment of the articulated stand. The design should ensure stable positioning, ease of use, and reliable performance during surgical procedures.The rotation socket should be designed for secure clamping onto the operating table and should be compatible with standard rails. It should be provided with a pre-mounted butterfly nut for easy fixation and include a lateral clamping mechanism to allow precise height and angle adjustment of the articulated stand. The design should ensure stable positioning, ease of use, and reliable performance during surgical procedures.
35The clamping jaw should be made of metal and provide a clamping range of approximately 4.8 mm to 12.5 mm. It should be equipped with a quick-release coupling system (male type) compatible with KSLOCK or equivalent mechanism. The device should be suitable for use with instrument and telescope sheaths, ensuring secure fixation, quick attachment and detachment, and stable performance during surgical procedures.The clamping jaw should be made of metal and provide a clamping range of approximately 4.8 mm to 12.5 mm. It should be equipped with a quick-release coupling system (male type) compatible with KSLOCK or equivalent mechanism. The device should be suitable for use with instrument and telescope sheaths, ensuring secure fixation, quick attachment and detachment, and stable performance during surgical procedures.
36DeBAKEY Grasping Forceps rotating type, with a connector pin for unipolar coagulation. It should be atraumatic with double-action jaws, having a diameter of 5 mm and a working length of 43 cm. The instrument should consist of a plastic handle without ratchet with a larger contact area, an insulated outer tube, and a compatible forceps insert, ensuring precise, atraumatic tissue handling and reliability in laparoscopic procedures.DeBAKEY Grasping Forceps rotating type, with a connector pin for unipolar coagulation. It should be atraumatic with double-action jaws, having a diameter of 5 mm and a working length of 43 cm. The instrument should consist of a plastic handle without ratchet with a larger contact area, an insulated outer tube, and a compatible forceps insert, ensuring precise, atraumatic tissue handling and reliability in laparoscopic procedures.
37Dissecting and Grasping Forceps rotating, with a connector pin for unipolar coagulation. It should have double-action jaws designed for effective tissue dissection and grasping, with atraumatic or serrated jaw profile as per clinical requirement. The instrument should be of 5 mm diameter with a working length of approximately 36 cm. It should include an ergonomic handle with ratchet mechanism for secure grip, an insulated outer tube, and a compatible forceps insert.Dissecting and Grasping Forceps rotating, with a connector pin for unipolar coagulation. It should have double-action jaws designed for effective tissue dissection and grasping, with atraumatic or serrated jaw profile as per clinical requirement. The instrument should be of 5 mm diameter with a working length of approximately 36 cm. It should include an ergonomic handle with ratchet mechanism for secure grip, an insulated outer tube, and a compatible forceps insert.
38The instrument should be a modular dissecting electrode system suitable for laparoscopic procedures, with an L-shaped electrode tip for precise dissection and coagulation. It should be compatible with standard unipolar electrosurgical units and provided with a connector pin for unipolar coagulation. The instrument should have a diameter of 5 mm and a working length of approximately 36 cm. It should consist of an insulated outer tube for patient safety, an ergonomic plastic handle for comfortable grip and control, and a detachable L-shaped electrode tips. The design should ensure effective energy transmission, precise tissue dissection, and safe, reliable performance during minimally invasive surgeries.The instrument should be a modular dissecting electrode system suitable for laparoscopic procedures, with an L-shaped electrode tip for precise dissection and coagulation. It should be compatible with standard unipolar electrosurgical units and provided with a connector pin for unipolar coagulation. The instrument should have a diameter of 5 mm and a working length of approximately 36 cm. It should consist of an insulated outer tube for patient safety, an ergonomic plastic handle for comfortable grip and control, and a detachable L-shaped electrode tips. The design should ensure effective energy transmission, precise tissue dissection, and safe, reliable performance during minimally invasive surgeries.
39The electrodes should be L-shaped and suitable for use in laparoscopic dissection and coagulation procedures. They should be compatible with standard unipolar electrosurgical instruments and designed to ensure precise energy delivery and effective tissue handling. The electrodes should be supplied in a sterile or non-sterile package of six units, suitable for repeated or single-use applications as per clinical requirements.The electrodes should be L-shaped and suitable for use in laparoscopic dissection and coagulation procedures. They should be compatible with standard unipolar electrosurgical instruments and designed to ensure precise energy delivery and effective tissue handling. The electrodes should be supplied in a sterile or non-sterile package of six units, suitable for repeated or single-use applications as per clinical requirements.
40The light adapter should have a diameter of 4.8 mm and be 90° angled, with a freely rotatable design for ease of handling. It should be compatible with standard laparoscopic scopes and ensure secure and efficient light transmission during surgical procedures.The light adapter should have a diameter of 4.8 mm and be 90° angled, with a freely rotatable design for ease of handling. It should be compatible with standard laparoscopic scopes and ensure secure and efficient light transmission during surgical procedures.
41The needle holder should be of KOH type with a dismantlable design, featuring an ergonomic pistol grip handle with a disengageable ratchet and ratchet release on the left side. It should have straight jaws with tungsten carbide inserts for enhanced durability and secure grip. The instrument should have a diameter of 5 mm and a working length of 33 cm. It should consist of a handle, an outer tube, and a compatible insert, ensuring precision, reliability, and ease of use during laparoscopic suturing procedures.The needle holder should be of KOH type with a dismantlable design, featuring an ergonomic pistol grip handle with a disengageable ratchet and ratchet release on the left side. It should have straight jaws with tungsten carbide inserts for enhanced durability and secure grip. The instrument should have a diameter of 5 mm and a working length of 33 cm. It should consist of a handle, an outer tube, and a compatible insert, ensuring precision, reliability, and ease of use during laparoscopic suturing procedures.
42Grasping Forceps should be of DeBAKEY type, rotating, with a connector pin for unipolar coagulation. It should have a diameter of 5 mm and a working length of 36 cm, with narrow and curved atraumatic double-action jaws for precise tissue handling. The instrument should consist of a plastic handle with a hemostat-style ratchet and a larger contact area, an insulated outer tube, and a compatible forceps insert, ensuring controlled grip, precision, and reliability in laparoscopic procedures.Grasping Forceps should be of DeBAKEY type, rotating, with a connector pin for unipolar coagulation. It should have a diameter of 5 mm and a working length of 36 cm, with narrow and curved atraumatic double-action jaws for precise tissue handling. The instrument should consist of a plastic handle with a hemostat-style ratchet and a larger contact area, an insulated outer tube, and a compatible forceps insert, ensuring controlled grip, precision, and reliability in laparoscopic procedures.
43Coagulating and Dissecting Electrode, L-shaped, with suction channel, The electrode should be L-shaped and suitable for laparoscopic coagulation and dissection, with an integrated channel for use with suction and irrigation handles. It should have a diameter of 5 mm and a working length of 36 cm. The instrument should be compatible with standard unipolar electrosurgical units and designed to enable simultaneous tissue dissection, coagulation, and fluid management, ensuring efficiency and precision during minimally invasive procedures.Coagulating and Dissecting Electrode, L-shaped, with suction channel, The electrode should be L-shaped and suitable for laparoscopic coagulation and dissection, with an integrated channel for use with suction and irrigation handles. It should have a diameter of 5 mm and a working length of 36 cm. The instrument should be compatible with standard unipolar electrosurgical units and designed to enable simultaneous tissue dissection, coagulation, and fluid management, ensuring efficiency and precision during minimally invasive procedures.
44The irrigation adaptor should be suitable for use with 5 mm coagulating and dissecting electrodes equipped with a suction channel. It should be provided with a standard LUER-Lock connector for secure and leak-proof connection to irrigation systems. The adaptor should be designed to ensure efficient fluid delivery, compatibility with standard laparoscopic instruments, and reliable performance during surgical procedures.The irrigation adaptor should be suitable for use with 5 mm coagulating and dissecting electrodes equipped with a suction channel. It should be provided with a standard LUER-Lock connector for secure and leak-proof connection to irrigation systems. The adaptor should be designed to ensure efficient fluid delivery, compatibility with standard laparoscopic instruments, and reliable performance during surgical procedures.
45The trocar should have a pyramidal tip and be equipped with an insufflation stopcock for controlled gas flow during laparoscopic procedures. It should have a diameter of 11 mm and a working length of 10.5 cm. The system should consist of a cannula without valve, a trocar obturator, and an automatic valve, ensuring secure access, effective sealing, and minimal gas leakage during surgical procedures.The trocar should have a pyramidal tip and be equipped with an insufflation stopcock for controlled gas flow during laparoscopic procedures. It should have a diameter of 11 mm and a working length of 10.5 cm. The system should consist of a cannula without valve, a trocar obturator, and an automatic valve, ensuring secure access, effective sealing, and minimal gas leakage during surgical procedures.
46The trocar should have a pyramidal tip and be equipped with an insufflation stopcock for controlled gas flow during laparoscopic procedures. It should have a diameter of 6 mm and a working length of 10.5 cm. The system should consist of a cannula without valve, a trocar obturator, and an automatic valve, ensuring secure access, effective sealing, and minimal gas leakage during surgical procedures.The trocar should have a pyramidal tip and be equipped with an insufflation stopcock for controlled gas flow during laparoscopic procedures. It should have a diameter of 6 mm and a working length of 10.5 cm. The system should consist of a cannula without valve, a trocar obturator, and an automatic valve, ensuring secure access, effective sealing, and minimal gas leakage during surgical procedures.
47Fiber Optic Light Cable Diameter 4.8 Mm Length 300 Cm With straight connector extremely heat- resi stant enhanced light transmissionFiber Optic Light Cable Diameter 4.8 Mm Length 300 Cm With straight connector extremely heat- resi stant enhanced light transmission

AI Tender Summary

OUR REF NO 57231284
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 18-09-2026
Authority
Authority Name All India Institute Of Medical Sciences
Work Description Bids Are invited for Laparoscopic Hand Instruments Set - Reducer 11/5 Mm , Clickline Plastic Handle, Style Ratchet, With Larger Contact Area At The Finger Ring, With Connector Pin For Unipolar Coagulation , Three Piece Laparoscopic Croce-Olmi Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet Metal Outer Sheath, Insulated Forceps Insert,Three Part Dismantel. , Three Piece Laparoscopic Croce-Olmi Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, With Ratchet & Metal Outer Sheath, Insulated Forceps Insert,Three Part Dismantel. , Three Piece Laparoscopic Croce-Olmi Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 43 Cm Consisting Of: Plastic Handle, Without Ratchet Metal Outer Sheath, Insulated Forceps Insert,Three Part Dismantel. , Three Piece Laparoscopic Croce-Olmi Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 43 Cm Consisting Of: Plastic Handle, With Ratchet Metal Outer Sheath, Insulated Forceps Insert,Three Part Dismantel. , Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Uni Polar Coagu- Lation, Size 5 Mm, Length 3 6 Cm, Right Angled, Double Action Jaws, Consisting Of: Plastic Handle, Wit Hout Ratchet, With Larger Contact Area , Three Piece Laparoscopic Kelly Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 43 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. , Three Piece Laparoscopic Kelly Dissecting And Grasping Forcep, Rotating, With Connector Pin Fo R Unipolar Coagulation, Size 5 Mm, Lengt H 36 Cm, Long, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area , Three Piece Laparoscopic Reddick-Olsen Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Heavy, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Outer Tube Insulated Forceps Insert,Three Part Dismantel. , Three Piece Laparoscopic Reddick-Olsen Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 43 Cm, Heavy, Double Action Jaws, Consisting Of: Plastic Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert,Three Part Dismantel. , Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm And Length 43 Cm, With Alligator Double-Action Jaws, Consisting Of A Plastic Handle Without Ratchet With A Larger Contact Area, An Insulated Outer Tube, And A Forceps Insert. , Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm And Length 43 Cm, With Alligator Double-Action Jaws, Consisting Of A Plastic Handle With Ratchet With A Larger Contact Area, An Insulated Outer Tube, And A Forceps Insert. , Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Fenestrated, Single Action Jaws, Having An Ergonomic Metal Handle With Plastic Finger Rings With Larger Contact Area At The Finger Ring To Avoid Pressure Sores , Debakey Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Atraumatic, Double-Action Jaws, Size 5 Mm, Length 36 Cm, Consisting Of A Plastic Handle With Ratchet And A Larger Contact Area, An Insulated Outer Tube, And A Forceps Insert. , The Electrode Should Be L-Shaped And Suitable For Coagulation And Dissection In Laparoscopic Procedures. It Should Have A Diameter Of 5 Mm And A Working Length Of 43 Cm. The Instrument Should Be Compatible With Standard Unipolar Electrosurgical Units And Designed For Precise Tissue Dissection And Effective Coagulation. , The Retractor Should Be Of Cuschieri Type, Suitable For Laparoscopic Procedures, With A Diameter Of 5 Mm And A Working Length Of 36 Cm. It Should Consist Of An Insert, An Outer Sheath, And A Compatible Handle, Designed To Provide Effective Retraction And Optimal Visualization During Surgical Procedures. , The Retractor Should Be Of Cuschieri Type With A Large Contact Surface, Suitable For Laparoscopic Procedures, With A Diameter Of 10 Mm And A Working Length Of 36 Cm. It Should Consist Of An Insert, An Outer Sheath, And A Compatible Handle, Designed To Provide Stable Tissue Retraction And Enhanced Surgical Field Exposure. , Dismantling Fan Retractor, Distendable, Size 10 Mm, Length 36 Cm. , The Needle Holder Should Be Of Koh Macro Type With An Ergonomic Axial Handle And A Disengageable Ratchet, With Ratchet Release On The Right Side. It Should Have Straight Jaws With Tungsten Carbide Inserts For Enhanced Durability And Grip. The Instrument Should Have A Diameter Of 5 Mm And A Working Length Of 43 Cm, Suitable For Laparoscopic Suturing Procedures. , The Needle Holder Should Be Of Koh Macro Type With Tungsten Carbide Inserts And An Ergonomic Pistol Handle With A Disengageable Ratchet, With Ratchet Positioned On The Left Side. It Should Have Jaws Curved To The Left, With A Diameter Of 5 Mm And A Working Length Of 33 Cm. The Instrument Should Be Suitable For Use With Suture Materials Ranging From 0-0 To 7/0 And Compatible With Needle Types Such As Bv, Sh, Or Ct-1, Ensuring Precise And Secure Suturing In Laparoscopic Procedures. , The Knot Tier Should Be Suitable For Extracorporeal Knotting In Laparoscopic Procedures, With A Diameter Of 5 Mm And A Working Length Of 36 Cm. The Instrument Should Be Designed To Facilitate Smooth And Secure Knot Advancement, Ensuring Precise Ligation And Ease Of Handling During Minimally Invasive Surgeries. , Berci Fascial Closure Instrument For Sub Cutaneous Ligature Of Trocar Incisions, Ening , Hook Scissors, Rotating Type, Size 5 Mm With A Working Length Of Approximately 43 Cm, Featuring Single-Action Jaws For Precise Dissection, Comprising A Plastic Handle Without Ratchet With A Large Contact Area, Insulated Outer Tube, And Hook Scissors Insert. , Grasping Forceps Rotating, With A Connector Pin For Unipolar Coagulation. It Should Have A Diameter Of 5 Mm And A Working Length Of 36 Cm, With Single-Action Jaws Featuring Multiple Teeth And A Jaw Width Of Approximately 4.8 Mm For Secure Tissue Handling. The Instrument Should Consist Of A Plastic Handle Without Ratchet With A Larger Contact Area, An Insulated Outer Tube, And A Compatible Forceps Insert, Ensuring Precision And Reliability In Laparoscopic Procedures. , Grasping Forceps Rotating, With A Connector Pin For Unipolar Coagulation. It Should Have A Diameter Of 5 Mm And A Working Length Of 43 Cm, With Single-Action Jaws Featuring Multiple Teeth And A Jaw Width Of Approximately 4.8 Mm For Secure Tissue Handling. The Instrument Should Consist Of A Plastic Handle Without Ratchet With A Larger Contact Area, An Insulated Outer Tube, And A Compatible Forceps Insert, Ensuring Precision And Reliability In Laparoscopic Procedures. , The Trocar Should Have A Pyramidal Tip And Be Provided With An Insufflation Stopcock For Controlled Gas Flow During Laparoscopic Procedures. It Should Have A Diameter Of 13.5 Mm And A Working Length Of 15 Cm, With Appropriate Color Coding For Easy Identification. The Trocar System Should Consist Of A Cannula, Trocar Obturator, And A Multifunctional Valve, Ensuring Secure Access, Minimal Gas Leakage, And Reliable Performance During Surgery. , The Trocar Should Have A Pyramidal Tip And Be Equipped With An Insufflation Stopcock For Controlled Gas Flow During Laparoscopic Procedures. It Should Have A Diameter Of 15 Mm And A Working Length Of 12 Cm. The System Should Consist Of A Cannula Without Valve, A Trocar Obturator, And An Automatic Valve, Ensuring Secure Access, Effective Sealing, And Minimal Gas Leakage During Surgical Procedures. , The Trocar Should Be Specifically Designed For Use In Obese Patients, With A Diameter Of 6 Mm And Appropriate Color Coding For Easy Identification. It Should Feature A Pyramidal Tip For Smooth And Controlled Entry And Be Provided With An Insufflation Stopcock For Gas Management. The System Should Include A Cannula Without Valve With An Extended Working Length Of Approximately 15 Cm, A Trocar Obturator, And A Multifunctional Valve, Ensuring Secure Access, Effective Sealing, And Reliable Performance During Laparoscopic Procedures. , Nathanson Liver Retractor, Small Surface Area, Dia 5 Mm. , Nathanson Liver Retractor, Medium Surface Area, Dia 5 Mm. , Nathanson Liver Retractor, Large Surface Area, Dia 5 Mm. , Articulated Stand , With Rotation Socket, To Cl On The Operating Table And Cl Ing Jaw, Metal, Cl Ing Range 16.5 Up To 23 Mm, , The Rotation Socket Should Be Designed For Secure Cl Ing Onto The Operating Table And Should Be Compatible With Standard Rails. It Should Be Provided With A Pre-Mounted Butterfly Nut For Easy Fixation And Include A Lateral Cl Ing Mechanism To Allow Precise Height And Angle Adjustment Of The Articulated Stand. The Design Should Ensure Stable Positioning, Ease Of Use, And Reliable Performance During Surgical Procedures. , The Cl Ing Jaw Should Be Made Of Metal And Provide A Cl Ing Range Of Approximately 4.8 Mm To 12.5 Mm. It Should Be Equipped With A Quick-Release Coupling System (Male Type) Compatible With Kslock Or Equivalent Mechanism. The Device Should Be Suitable For Use With Instrument And Telescope Sheaths, Ensuring Secure Fixation, Quick Attachment And Detachment, And Stable Performance During Surgical Procedures. , Debakey Grasping Forceps Rotating Type, With A Connector Pin For Unipolar Coagulation. It Should Be Atraumatic With Double-Action Jaws, Having A Diameter Of 5 Mm And A Working Length Of 43 Cm. The Instrument Should Consist Of A Plastic Handle Without Ratchet With A Larger Contact Area, An Insulated Outer Tube, And A Compatible Forceps Insert, Ensuring Precise, Atraumatic Tissue Handling And Reliability In Laparoscopic Procedures. , Dissecting And Grasping Forceps Rotating, With A Connector Pin For Unipolar Coagulation. It Should Have Double-Action Jaws Designed For Effective Tissue Dissection And Grasping, With Atraumatic Or Serrated Jaw Profile As Per Clinical Requirement. The Instrument Should Be Of 5 Mm Diameter With A Working Length Of Approximately 36 Cm. It Should Include An Ergonomic Handle With Ratchet Mechanism For Secure Grip, An Insulated Outer Tube, And A Compatible Forceps Insert. , The Instrument Should Be A Modular Dissecting Electrode System Suitable For Laparoscopic Procedures, With An L-Shaped Electrode Tip For Precise Dissection And Coagulation. It Should Be Compatible With Standard Unipolar Electrosurgical Units And Provided With A Connector Pin For Unipolar Coagulation. The Instrument Should Have A Diameter Of 5 Mm And A Working Length Of Approximately 36 Cm. It Should Consist Of An Insulated Outer Tube For Patient Safety, An Ergonomic Plastic Handle For Comfortable Grip And Control, And A Detachable L-Shaped Electrode Tips. The Design Should Ensure Effective Energy Transmission, Precise Tissue Dissection, And Safe, Reliable Performance During Minimally Invasive Surgeries. , The Electrodes Should Be L-Shaped And Suitable For Use In Laparoscopic Dissection And Coagulation Procedures. They Should Be Compatible With Standard Unipolar Electrosurgical Instruments And Designed To Ensure Precise Energy Delivery And Effective Tissue Handling. The Electrodes Should Be Supplied In A Sterile Or Non-Sterile Package Of Six Units, Suitable For Repeated Or Single-Use Applications As Per Clinical Requirements. , The Light Adapter Should Have A Diameter Of 4.8 Mm And Be 90° Angled, With A Freely Rotatable Design For Ease Of Handling. It Should Be Compatible With Standard Laparoscopic Scopes And Ensure Secure And Efficient Light Transmission During Surgical Procedures. , The Needle Holder Should Be Of Koh Type With A Dismantlable Design, Featuring An Ergonomic Pistol Grip Handle With A Disengageable Ratchet And Ratchet Release On The Left Side. It Should Have Straight Jaws With Tungsten Carbide Inserts For Enhanced Durability And Secure Grip. The Instrument Should Have A Diameter Of 5 Mm And A Working Length Of 33 Cm. It Should Consist Of A Handle, An Outer Tube, And A Compatible Insert, Ensuring Precision, Reliability, And Ease Of Use During Laparoscopic Suturing Procedures. , Grasping Forceps Should Be Of Debakey Type, Rotating, With A Connector Pin For Unipolar Coagulation. It Should Have A Diameter Of 5 Mm And A Working Length Of 36 Cm, With Narrow And Curved Atraumatic Double-Action Jaws For Precise Tissue Handling. The Instrument Should Consist Of A Plastic Handle With A Hemostat-Style Ratchet And A Larger Contact Area, An Insulated Outer Tube, And A Compatible Forceps Insert, Ensuring Controlled Grip, Precision, And Reliability In Laparoscopic Procedures. , Coagulating And Dissecting Electrode, L-Shaped, With Suction Channel, The Electrode Should Be L-Shaped And Suitable For Laparoscopic Coagulation And Dissection, With An Integrated Channel For Use With Suction And Irrigation Handles. It Should Have A Diameter Of 5 Mm And A Working Length Of 36 Cm. The Instrument Should Be Compatible With Standard Unipolar Electrosurgical Units And Designed To Enable Simultaneous Tissue Dissection, Coagulation, And Fluid Management, Ensuring Efficiency And Precision During Minimally Invasive Procedures. , The Irrigation Adaptor Should Be Suitable For Use With 5 Mm Coagulating And Dissecting Electrodes Equipped With A Suction Channel. It Should Be Provided With A Standard Luer-Lock Connector For Secure And Leak-Proof Connection To Irrigation Systems. The Adaptor Should Be Designed To Ensure Efficient Fluid Delivery, Compatibility With Standard Laparoscopic Instruments, And Reliable Performance During Surgical Procedures. , The Trocar Should Have A Pyramidal Tip And Be Equipped With An Insufflation Stopcock For Controlled Gas Flow During Laparoscopic Procedures. It Should Have A Diameter Of 11 Mm And A Working Length Of 10.5 Cm. The System Should Consist Of A Cannula Without Valve, A Trocar Obturator, And An Automatic Valve, Ensuring Secure Access, Effective Sealing, And Minimal Gas Leakage During Surgical Procedures. , The Trocar Should Have A Pyramidal Tip And Be Equipped With An Insufflation Stopcock For Controlled Gas Flow During Laparoscopic Procedures. It Should Have A Diameter Of 6 Mm And A Working Length Of 10.5 Cm. The System Should Consist Of A Cannula Without Valve, A Trocar Obturator, And An Automatic Valve, Ensuring Secure Access, Effective Sealing, And Minimal Gas Leakage During Surgical Procedures. , Fiber Optic Light Cable Diameter 4.8 Mm Length 300 Cm With Straight Connector Extremely Heat- Resi Stant Enhanced Light Transmission
Basic Detail
Tender No GEM/2026/B/7909959
Bidding Type Tender
Location
City Nadia
State West Bengal
Key Dates
Publish Date 28 Aug 2026
Submission Date 18 Sep 2026
Open Date 18 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 1.32 Lakhs
Exemption Available
Document List
46939b0b-049a-4d39-b98b-54e6ec768af4.pdf
1786534474.xlsx
laparo_spec_2026-08-12-16-20-10_c2661ea1ee1721aa4759d01764bdb204.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Sep 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
pdf

46939b0b-049a-4d39-b98b-54e6ec768af4.pdf

xlsx

1786534474.xlsx

pdf

laparo_spec_2026-08-12-16-20-10_c2661ea1ee1721aa4759d01764bdb204.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail