Tender For Supply, Installation, Testing And Commissioning Of 1000 Kva Distribution Transformer, Ht Breaker And Distribution Panel Board At Csir Neist, Jorhat
Tender Value
80.81 Lakhs
Estimated cost
Bid Submission
22 Sep 2026
25 days left
EMD
1.61 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jorhat → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Installation, Testing And Commissioning Of 1000 Kva Distribution Transformer, Ht Breaker And Distribution Panel Board At Csir Neist, Jorhat
BOQ
| Sl. No. | Item Description |
| 1 | Schedule of Quantities NIT No. NEIST-29(501)/WE-2024 Supplying,installation, testing and commissioning of 1000 kVA Distribution Transformer,HT Breaker and Distribution Panel Board at CSIR-NEIST, Jorhat Sl No. Particulars of the item Unit Qnty Rate in figures Rates in words Amount in Rs. A B C D E F G=D*E |
| 2 | Supply, installation, testing and commissioning of 1000 kVA, 11/0.415 kV copper wound oil cooled indoor type floor mounted distribution transformer complete with all accessories, connection including first filled transformer oil, earthing complete as required. |
| 3 | Supply, installation, testing and commissioning of 1250 A indoor type floor mounted 11 kV drawout VCB panel of 1 incoming 5 outgoing (1+5) ways, 230Volts AC spring charging motor, 110/24VDC closing coil, 110/24VDC shut trip coil aux contact complete with all accessories including PT/CT, earthing etc as required. |
| 4 | Supply of 1.1 kV grade single core 630 sq.mm. size aluminium strainded armourd XLPE power cable complete with as required. |
| 5 | Supply of 11 kV grade 3 x 120 sq.mm. size aluminium strainded armourd XLPE power cable complete with as required. |
| 6 | Supply of 1.1 kV grade 3.5 x 240 sq.mm. size aluminium strainded armourd XLPE power cable complete with as required. |
| 7 | Supply of 1.1 kV grade 3.5 x 120 sq.mm. size aluminium strainded armourd XLPE power cable complete with as required. |
| 8 | Supply, installation, testing and commissioning of 1200 A capacity medium voltage 415V, CPRI approved, GI sheet/Polycarbonate cubical distribution panel board complete with ACB, automatic changeover switch, OG MCCBs, ammeters, voltmeters, indicating lamps, earthing complete with all necessary connection as required. |
| 9 | Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing mansonary enclosure with cover pale having locking arrangement and watering pipe of 2.7 Mtr long etc with charcola/coke and salt as required. |
| 10 | Supplying and laying 25 mm x 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc as required ( Jointing shall be done by operlapping and with 2 sets of brass nut bolt and spring washer spaced at 50 mm) |
| 11 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in the existing masonary open duct as required i Upto 120 sq.mm Mtr 50.0 |
| 12 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in the existing masonary open duct as required i Above 95 sq.mm and upto 185 sq.mm Mtr 110.0 |
| 13 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size 3 core XLPE aluminium conductor cable of 11 kV grade required i 120 sq.mm Each 6.0 |
| 14 | Supplying and making straight through joint with heat shrinkable jointing kit complete with all accessories including lugs suitable for following sizes of XLPE aluminium conductor cable of 1.1 kV grade required i 3.5 x 120 sq.mm Each 5.0 |
| 15 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of 630 sq.mm size single core cable in the existing masonary open duct as required |
| 16 | Supplying and fixing required sizes of ring type aluminium cable lugs with proper sizes of brass compression gland, cable end termination and proper crimping with the help of machine including necessary connection as required i 3.5 x 240 sq.mm Set 4.0 ii 3.5 x 120 sq.mm Set 5.0 iii 1 C x 630 sq.mm. Set 8.0 |
| 17 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 18 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 19 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan). including dressing of sides and ramming of bottoms. lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 20 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 1:6 (/cement6 coarse sand) |
| 21 | Providing and laying in position cement concrete of speci ied grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement 3 coarse sand (zone-Ill) derived from natural sources 6 graded stone aggregate 20 mm nominal size derived from natural sources. |
| 22 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanical Treated bars of grade Fe-5000 or more |
| 23 | Centering and shuttering including strutting. propping etc. And removal of form for all heights Lintels beam,plinth beam,griders, bressumers and cantilivers |
| 24 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering. shuttering. finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources |
| 25 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1cement : 4 coarse sand) |
| 26 | Supplying and filling in pinth with sand under floors, including water, ramming,consolidating and dressing complete |
| 27 | Half brick mansonary with common burnt clay FPS (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement morter 1:4 (1 cement: 4 coarse sand) |
| 28 | Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement,20 mm cement plaster. |
| 29 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement 5 coarse sand finished with a top layer 6 mm thick cement plaster 1 6 (1 cement 6 fine sand). |
| 30 | Providing and applying white cement based putty of average thickness 1 mm, of pproved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 31 | Wall painting with premium acrylic emulsion paint of intenor grade Sqm having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture. including applying additional coats wherever required to achieve even shade and colour. Two coats. |
| 32 | Finishing walls with Acrylic Smooth exterior paint of required shade :Sqm New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 33 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. |
| 34 | Providing corrugated G.S. sheet roofing including vertical / curvedSqm surface fixed with polymer coated J or L hooks. bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zink coating not less than 275 gm/m |
| 35 | Supplying and fixing rolling shutters of approved make. made ofSqm required size M.S. laths. interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover |
| 36 | Providing and fixing aluminium work for doors, windows, ventilators Kg and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 37 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) Total quoted amount in Rs. Rupees ..........…........................................................................................................................................................................................ ….............................................................................................................................................only NB Above rates are inclusive of all government levies. No alternation or editing of the itemes are acceptable. Name of the Quoted firm : Firm GSTIN No. Seal & Signature |
AI Tender Summary
Tender Timeline
Aug 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 25 daysSep 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender