Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #57229126

Tender For Repair/Replacement Of Lt Switch Gears, Acbs, Lt Pannels, Feeder Pillar Boxes And Connected Works At Af Stn Dalhousie

Issued by Statutory Bodies & Commissions/Committees · Pathankot, Punjab
Tender Value
35 Lakhs
Estimated cost
Bid Submission
18 Sep 2026
21 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Lt Switch Gears, Acbs, Lt Pannels, Feeder Pillar Boxes And Connected Works At Af Stn Dalhousie

BOQ

Name of Work:- Repair/Replacement of LT switch gears, ACBs, LT pannels, feeder pillar boxes and connected works at AF Stn Dalhousie
Sl. No. Item Description
1Supplying including laying testing and connecting in replacement of XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electrical cable with aluminium conductor, 1100 volts grade, cross-sectional area with suitable lugs of following sizes:.(a) 16 sqmm 2 core
2(b) 25 sqmm 2 core
3(c) 35 sqmm 3.5 core
4(d) 50 sqmm 3.5 core
5(e) 70 sqmm 3.5 core
6(f) 95 sqmm 3.5 core
7(g) 120 sqmm 3.5 core
8(h) 240 sqmm 3.5 core
9M&L for excavation in trenches in any type of soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, laying of cables and getting out complete all as specified & as directed by Engineer-in-charge.
10M&L for returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm each layer all as specified.
11M&L for removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified.
12M&L for sand cushioning to under ground cable 8 cm thick layer below the cable and 15cm thick above the cable complete and all as directed & specified.
13M&L for brick protection with well burnt sub class ‘B’ brick a butting each other( width wise) across the cable laid in trenches complete and all as specified.
14Supply and install in replacement ACB 4 Pole, 50 KA, 415 volt with thermal magnetic release, adjustable, manual fixed type of capacity 630 Amp complete all as specified and directed by Engr-in-Charge.
15S&F in replacement of single core copper multistrandred conductor flexible PVC Insulated heavy duty Industrial cable (unsheathed) 1100 volts size 16 sqmm ( per 100 RM roll)
16S&F in replacement of MCCB 4 Pole 415 Volts with rupturing capacity 16 KA 100 Amps fixed type complete all as specified and directed by Engr-in-charge.
17S&F in replacement of MCCB 4 Pole 415 Volts with rupturing capacity 16 KA 125 Amps fixed type all as specified and directed by Engr-in-charge.
18S&F in replacement of MCCB 4 Pole 415 Volts with rupturing capacity 35/36 KA 160 Amps Adjustable type thermal Megnatic release all as specified and directed by Engr-in-charge.
19S&F in replacement of MCCB 4 Pole 415 Volts with rupturing capacity 35/36 KA 250 Amps Adjustable type thermal Megnatic release all as specified and directed by Engr-in-charge.
20Scraping of old paint from the street light pole with out removing accessories and preparation of surfaces for repainting. Repainting the electric pole with one coat of alternative black and yellow (existing colour) straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint, repainting the remaining pole and iron parts i.e U clamps, chanels etc above 1.5 mtr height by applying one coat of alumn paint including writing Pole Nos. with Black paint all as per specified at site and directed by Engineer-in-Charge.
21S&F in replacement of street light pole box suitable for fixing on LT pole size 200x160x98 mm 25 sqmm Terminal block 4 Nos, 4 sqmm Earth terminal 1 No with suitable gland , door and locking arrangment and suitable for terminal single phase including MCB 6-10A SP and fixing in position with nut, bolt, clamp, disconnection and reconnection of service wire/UG cabel in box incl dismentling old street pole box all as specified and directed. Make Hensell,Sintax and Anchor
22M&L in replacement of tubing GI light grade 50 mm bore for cable protection laid in ducts, fixed to wall or poles including fixing arrangement all as required and directed by Engineer-in-Charge.
23All as per srl item No 15 here-in-before but of size 40 mm bore.
24M&L in replacement of earthing complete with galvanized cast iron earth plate electrode 600x600x6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below ;normal ground level ) with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to galvanized iron strip 32x6 mm as earth lead by means of bolts, nuts washers and check nuts of steel/GI duly protected with 40 mm bore light grade pipe upto main board , 20mm bore watering pipe light grade with CI/MS funnel and wire mesh including excavation , earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, add charcoal dust and common salt after mixing with BFC (Back Fill Compound) inadeqate quantity as recommended by the manufacturer or as diirectred by the Engr-in-charge all as shown in electrical plate No. 03 of SSR part-I 2009 having pit in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for CI cover of required size, funnel with wire mesh complete and all as specified and as directed by Engr-in-charge. Note : If the earth result of the earthing found more than 4 Ohms then new earthing will be executed by the contractor without any extra cost for the result upto 4 ohms
25S&F in replacement of onload change overswitch 125 Amps, 4 pole, 415 V including making necessary connections on wall/LT panels etc with suitable size of thimbles, cable glands and jointing material etc all as specified and directed by the Engr-in-charge.
26All as per item no 18, but size 100 Amps complete.
27S&F in replacement of Automatic Transfer Switch Four Pole, AC-31A, 50 Hz, 415 V Automatic/Manual with complete protection of size 200 Amps, including making necessary connections on wall/LT panels etc with suitable size of thimbles, cable glands and jointing material etc all as specified and directed by the Engr-in-charge. Make : Havells Euroload or equivalent
28M&L in replacement of LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66protection, with impact and corrosion resistant complete with driver and lampcomplete all as specified and directed by the Engr-in-charge.
29M&L in replacement street light fitting, powder coated, pressure die cast aluminium IP 66, 90 watt with 100Lm/watt compact LED light with heat resistant toughened glass with lens, complete and making connection from junction box to fitting in PVC conduit by using PVC cable with copper conductor of size 2.5 Sqmm 3 core,fixing in existing brackets with required addition/alteration if any complete all as directed and specified
30Supply only PVC insulation LT tape of size 15M x 1.8cm x 0.125 mm
31M&L for fabrication, installation and testing of LT feeder piller box floor mounted dust/vermin proof outdoor type, powder coated of size 0.60x0.85x0.50 mtr factory fabricated, made out of MS sheet of thickness 2mm mounted on angle iron legs made out of angle iron of size 40x40x6mm withn friont & rear opening with locking arrangement, powder coated, contain bus bar chamber to accommodate 3phase & 1 nutral copper busbar of size 20 x 10mm fixed on epoxy based insulators in horizontal position(steped manner) in feeder pillar including necessary excavation and PCC work 1:2:4 complete all as specified and directed by Engr-in-charge (Note) All accessories pre wired with suitable size copper conductor cable including making necessary arrangements for fixing all as required at site or directed.
32Fabrication, installation and testing in replacement of LT panel floor mounted dust/vermin proof outdoor type double door, powder coated of size as suitable for given items, factory fabricated, made out of MS sheet of thickness 2mm mounted on angle iron legs made out of angle iron of size 40x40x6mm withn friont & rear opening with locking arrangement, powder coated, contain bus bar chamber to accommodate 3phase & 1 neutral copper busbar of size 40 x 10mm fixed on hydroscopic based insulators in horizontal position(steped manner) in upper part of panel; In middle part of panel provide seprate chambers for 01 No. incomming MCCB and 03 Nos. for Outgoing MCCBs connected to busbar by copper strip of size 20 x 5mm; bottom part acoommodate connections of Cables complete all as required on site and as directed by Engineer-incharge including the Following :-(a) MCCB 125 Amps TPN 35 Ka (adjustable type) . I/C - 01 No. (b) MCCB 63 Amps TPN 35 Ka (adjustable type) . O/G - 03 No. (c) Digital Multi-function meter – 01 No (d) Set of selecor switches - 01 Set (e) Indicator lamps (R, Y. B) – 01 Set. ( Note ) All accessories pre wired with suitable size copper conductor cable including making necessary arrangements for fixing all as required at site or directed.
33Fabrication, installation and testing in replacement of LT panel floor mounted dust/vermin proof outdoor type double door, powder coated of size as suitable for given items, factory fabricated, made out of MS sheet of thickness 2mm mounted on angle iron legs made out of angle iron of size 40x40x6mm withn friont & rear opening with locking arrangement, powder coated, contain bus bar chamber to accommodate 3phase & 1 neutral copper busbar of size 40 x 10mm fixed on hydroscopic based insulators in horizontal position(steped manner) in upper part of panel; In middle part of panel provide seprate chambers for 01 No. incomming MCCB and 03 Nos. for Outgoing MCCBs connected to busbar by copper strip of size 20 x 5mm; bottom part acoommodate connections of Cables complete all as required on site and as directed by Engineer-incharge including the Following :-(a) MCCB 250 Amps TPN 35 Ka (adjustable type) . I/C - 01 No. (b) MCCB 160 Amps TPN 35 Ka (adjustable type) . I/C - 01 No for DG set (c) MCCB 125 Amps TP 35 Ka (adjustable type) . O/G - 01 No. (d) MCCB 100 Amps TP 35 Ka (adjustable type) . O/G - 03 No. (e) Changeover switch 250 Amps 4 pole - 01 Nos.(O/G) (f) Digital Multi-function meter – 01 No (g) Set of selecor switches - 01 Set (h) Indicator lamps (R, Y. B) – 01 Set. ( Note ) All accessories pre wired with suitable size copper conductor cable including making necessary arrangements for fixing all as required at site or directed.
34S&F 1100 volts grade heavy duty cable PVC insulated aluminium staranded conductor , served with inner sheathed PVC tape and overall PVC sheathed in service connection one twin core flat or circular of size 10 sqmm x 2core complete all as specified Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57229126
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 35 Lakhs
LAST DATE 18-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Lt Switch Gears, Acbs, Lt Pannels, Feeder Pillar Boxes And Connected Works At Af Stn Dalhousie
Basic Detail
Tender No GE/PAF-81/2026-27
Bidding Type Tender
Location
City Pathankot
State Punjab
Key Dates
Publish Date 27 Aug 2026
Submission Date 18 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value 35 Lakhs
Tender Fee 500
EMD 70000
Exemption Available
Document List
BOQ_881572.xls
ef0bbc2f-b580-43aa-9195-3e91455448a0.html
Tender81.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_881572.xls

html

ef0bbc2f-b580-43aa-9195-3e91455448a0.html

pdf

Tender81.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders