Tender For Repair/ Maintenance Of Flame Proof Fittings, Wiring And Connected Items In Certain Tech Bldgs At Af Stn Jodhpur
Tender Value
40 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
2 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of Flame Proof Fittings, Wiring And Connected Items In Certain Tech Bldgs At Af Stn Jodhpur
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/ aluminium point wiring of light, fan, socket or power complete including removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors etc. complete all as specified and as directed by Engineer-in-Charge. |
| 2 | M&L for cutting chases, pinning in brick wall, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and as directed. |
| 3 | M&L for cutting chases, pinning in concreate/ stone wall, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and as directed. |
| 4 | M&L for point wiring complete with 1.5 Sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade IS-694 (Phase - Red/ Blue/ Yellow, Netural -Black and earth continuity conductor 1.50 Sqmm Green) drawn through and including stove enameled steel conduit not less than 20mm x 12mm, ISI marked including accessories like bends, tees junction boxes, etc. fixed on wall or ceiling etc. including 1.5 Sqmm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size white sheet cover for mounting swiches, sockets, fan regulators etc. complete for one flame proof light point/ flame proof fans/ flame proof exhaust fans point controlled by one flame proof rotary switch 6/ 10/ 16 Amp complete all as specified and as directed.Note:- Necessary chases cuttings for concealed wiring and making a good of distrubed surfaces are measured and paid under relevant items. |
| 5 | All as per Item No. 04 above but with 2.5 Sqmm cable for independent one 6 pin 6/ 16/ 32 Amps socket outlet in and including 2.5 Sqmm PVC insulated copper conductor unsheathed 1100 V grade IS -694 FRLS cable for continuous earth wire. |
| 6 | M&L for point wiring for modular accessories with modular metal flush box and cover plate with frame of suitable size complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade, drawn through and including casing caping/ open conduit including 1.5 Sqmm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire terminated in new modular sunken boxes and modular metal flush box of required size at site including all connected accessories, box made from thickness not less than 1.6mm GI sheet, factory made for one 3 pin socket outlet, 5 Amps on independent board complete all as specified and as directed.Note:- Necessary chases cuttings for concealed wiring and making a good of distrubed surfaces are measured and paid under relevant items. |
| 7 | All as per Item No. 06 above but with cable of size 2.5 Sqmm PVC insulated cable on independent board for power plug 15 Amps. |
| 8 | S&F in repair modular switch, 01 way, 06 Amps, 240 Volts complete all as specified and as directed. |
| 9 | S&F in repair modular switch, 01 way, 16 Amps, 240 Volts complete all as specified and as directed. |
| 10 | S&F in repair modular socket, 02 module, 06 Amps, 240 Volts complete all as specified and as directed. |
| 11 | S&F in repair modular socket, 02 module, 16 Amps, 240 Volts complete all as specified and as directed. |
| 12 | S&F in repair flame proof rotary on/ off switch current rating : 10/ 16 Amps, 230 Volts with termination box for industrial use Number pole : two switch positions 5 to 8, 2 to 4 with IP 66 suitable at gasies/ fire hazardious areas complete all as specified and as directed. |
| 13 | S&F in repair industrial type flame proof switch plug and socket 16 Amps, 3 pin, electrical rating 16 Amp, 3 pin (2P+1E), weather proof alongwith IP 66 suitable at gasies/ fire hazardious areas, Gasket- 'O' ring endless neoprene, Material- cast aluminium alloy LM-6 complete all as specified and as directed. |
| 14 | S&F in repair industrial type flame proof switch plug and socket 32 Amps, 5 pin, electrical rating 32 Amps, 5 pin (4P+1E), weather proof alongwith IP 66 suitable at gasies/ fire hazardious areas, Gasket- 'O' ring endless neoprene, Material - cast aluminium alloy LM-6 complete all as specified and as directed. |
| 15 | M&L for submain wiring with two single core 10.0 Sqmm FRLS PVC insulated copper cable 1100 Vots grade multistrand, unseathed conductor drawn into suitabke size stove enamelled steel conduit and all necessary fittings including 10 Sqmm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dully complete including taking down old unserviceable sub main wiring of any size and making good disturbed surface complete all as specified and directed.Note:- Necessary chases cuttings for concealed wiring and making a good of distrubed surfaces are measured and paid under relevant items. |
| 16 | All as per Item No. 15 above but two single core 6.0 Sqmm for phase and neutral and 01 single core 6 Sqmm for earth wire. |
| 17 | All as per Item No. 15 above but two single core 4.0 Sqmm for phase and neutral and 01 single core 4 Sqmm for earth wire. |
| 18 | All as per Item No. 15 above but two single core 2.5 Sqmm for phase and neutral and 01 single core 2.5 Sqmm for earth wire. |
| 19 | All as per Item No. 15 above but two single core 1.5 Sqmm for phase and neutral and 01 single core 1.5 Sqmm for earth wire. Please Enable Macros to View BoQ information |
| 20 | All as per Item No. 15 above but two single core 1.5 Sqmm for phase and neutral and 01 single core 1.5 Sqmm for earth wire. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysSep 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender