Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #57229118

Tender For Repair/ Maintenance Of Flame Proof Fittings, Wiring And Connected Items In Certain Tech Bldgs At Af Stn Jodhpur

Issued by Statutory Bodies & Commissions/Committees · Jodhpur, Rajasthan
Tender Value
40 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
2 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance Of Flame Proof Fittings, Wiring And Connected Items In Certain Tech Bldgs At Af Stn Jodhpur

BOQ

Name of Work:- REPAIR/ MAINT OF FLAME PROOF FITTINGS, WIRING AND CONNECTED ITEMS IN CERTAIN TECH BLDGS AT AF STN JODHPUR
Sl. No. Item Description
1Taking down carefully copper/ aluminium point wiring of light, fan, socket or power complete including removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors etc. complete all as specified and as directed by Engineer-in-Charge.
2M&L for cutting chases, pinning in brick wall, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and as directed.
3M&L for cutting chases, pinning in concreate/ stone wall, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and as directed.
4M&L for point wiring complete with 1.5 Sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade IS-694 (Phase - Red/ Blue/ Yellow, Netural -Black and earth continuity conductor 1.50 Sqmm Green) drawn through and including stove enameled steel conduit not less than 20mm x 12mm, ISI marked including accessories like bends, tees junction boxes, etc. fixed on wall or ceiling etc. including 1.5 Sqmm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size white sheet cover for mounting swiches, sockets, fan regulators etc. complete for one flame proof light point/ flame proof fans/ flame proof exhaust fans point controlled by one flame proof rotary switch 6/ 10/ 16 Amp complete all as specified and as directed.Note:- Necessary chases cuttings for concealed wiring and making a good of distrubed surfaces are measured and paid under relevant items.
5All as per Item No. 04 above but with 2.5 Sqmm cable for independent one 6 pin 6/ 16/ 32 Amps socket outlet in and including 2.5 Sqmm PVC insulated copper conductor unsheathed 1100 V grade IS -694 FRLS cable for continuous earth wire.
6M&L for point wiring for modular accessories with modular metal flush box and cover plate with frame of suitable size complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade, drawn through and including casing caping/ open conduit including 1.5 Sqmm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire terminated in new modular sunken boxes and modular metal flush box of required size at site including all connected accessories, box made from thickness not less than 1.6mm GI sheet, factory made for one 3 pin socket outlet, 5 Amps on independent board complete all as specified and as directed.Note:- Necessary chases cuttings for concealed wiring and making a good of distrubed surfaces are measured and paid under relevant items.
7All as per Item No. 06 above but with cable of size 2.5 Sqmm PVC insulated cable on independent board for power plug 15 Amps.
8S&F in repair modular switch, 01 way, 06 Amps, 240 Volts complete all as specified and as directed.
9S&F in repair modular switch, 01 way, 16 Amps, 240 Volts complete all as specified and as directed.
10S&F in repair modular socket, 02 module, 06 Amps, 240 Volts complete all as specified and as directed.
11S&F in repair modular socket, 02 module, 16 Amps, 240 Volts complete all as specified and as directed.
12S&F in repair flame proof rotary on/ off switch current rating : 10/ 16 Amps, 230 Volts with termination box for industrial use Number pole : two switch positions 5 to 8, 2 to 4 with IP 66 suitable at gasies/ fire hazardious areas complete all as specified and as directed.
13S&F in repair industrial type flame proof switch plug and socket 16 Amps, 3 pin, electrical rating 16 Amp, 3 pin (2P+1E), weather proof alongwith IP 66 suitable at gasies/ fire hazardious areas, Gasket- 'O' ring endless neoprene, Material- cast aluminium alloy LM-6 complete all as specified and as directed.
14S&F in repair industrial type flame proof switch plug and socket 32 Amps, 5 pin, electrical rating 32 Amps, 5 pin (4P+1E), weather proof alongwith IP 66 suitable at gasies/ fire hazardious areas, Gasket- 'O' ring endless neoprene, Material - cast aluminium alloy LM-6 complete all as specified and as directed.
15M&L for submain wiring with two single core 10.0 Sqmm FRLS PVC insulated copper cable 1100 Vots grade multistrand, unseathed conductor drawn into suitabke size stove enamelled steel conduit and all necessary fittings including 10 Sqmm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dully complete including taking down old unserviceable sub main wiring of any size and making good disturbed surface complete all as specified and directed.Note:- Necessary chases cuttings for concealed wiring and making a good of distrubed surfaces are measured and paid under relevant items.
16All as per Item No. 15 above but two single core 6.0 Sqmm for phase and neutral and 01 single core 6 Sqmm for earth wire.
17All as per Item No. 15 above but two single core 4.0 Sqmm for phase and neutral and 01 single core 4 Sqmm for earth wire.
18All as per Item No. 15 above but two single core 2.5 Sqmm for phase and neutral and 01 single core 2.5 Sqmm for earth wire.
19All as per Item No. 15 above but two single core 1.5 Sqmm for phase and neutral and 01 single core 1.5 Sqmm for earth wire. Please Enable Macros to View BoQ information
20All as per Item No. 15 above but two single core 1.5 Sqmm for phase and neutral and 01 single core 1.5 Sqmm for earth wire. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57229118
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 15-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Of Flame Proof Fittings, Wiring And Connected Items In Certain Tech Bldgs At Af Stn Jodhpur
Basic Detail
Tender No 8504/E8
Bidding Type Tender
Location
City Jodhpur
State Rajasthan
Key Dates
Publish Date 27 Aug 2026
Submission Date 15 Sep 2026
Open Date 17 Sep 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
83fd693f-70c7-4f55-a3d3-ceac67f0242f.html
8504TENDER.pdf
BOQ_881608.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Sep 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

83fd693f-70c7-4f55-a3d3-ceac67f0242f.html

pdf

8504TENDER.pdf

xls

BOQ_881608.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders