Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #57229101

Tender For Repair/ Replacement Of Internal Wiring/ Electrical Fitting/ Fixtures Including Controls, Motion Sensor Lights & Repair / Servicing Of Fan And Geysers At Various Location At installation Shikra & Other Connected Area Under Ge (Nw) Nofra.

Issued by Statutory Bodies & Commissions/Committees · Mumbai, Maharashtra
Tender Value
49 Lakhs
Estimated cost
Bid Submission
14 Sep 2026
14 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement Of Internal Wiring/ Electrical Fitting/ Fixtures Including Controls, Motion Sensor Lights & Repair / Servicing Of Fan And Geysers At Various Location At installation Shikra & Other Connected Area Under Ge (Nw) Nofra.

BOQ

Name of Work:- REPAIR/ REPLACEMENT OF INTERNAL WIRING/ ELECTRICAL FITTING/ FIXTURES INCLUDING CONTROLS, MOTION SENSOR LIGHTS & REPAIR / SERVICING OF FAN AND GEYSERS AT VARIOUS LOCATION AT INS SHIKRA & OTHER CONNECTED AREA UNDER GE (NW) NOFRA.
Sl. No. Item Description
1Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators,sockets,light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engr in Charge.
2Material and Labour for point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC Casing caping of size not less than 20 / 25 mm dia including PVC bend, tee joints etc as per site requirement , ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes/ modular boxes surfacing on wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed by Engr in Charge.
3(a) One light point controlled by one switch SP one way.
4(b) One ceiling fan point controlled with one 5A switch
5(c) One exhaust fan point controlled with one 5A switch
6(d) One 3 pin socket outlet 5Amps on independant board.
7(e) One 3 pin socket outlet 5Amps on same board with other switches.
8All as per item No 2 above but for point wiring for 15 Amps socket complete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductor cable complete all as specified and directed.
9Supply and fix Modular Switch, 6Amp, One way, 1 module complete all as specified and directed by Engr in Charge.
10Supply and fix Modular switch 1 way 16A,1 module complete all as specified and directed by Engr in Charge.
11Supply and fix support function blank plate single, 1 module complete all as specified and directed.
12Supply and fix Modular type, electronic fan regulator (5 step), 450 Watts, 230 volts, 2 module complete all as specified and directed .
13Supply and fix ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified.
14Supply and fix Modular Socket oulet, 6 Amps, 2/3 pin combined, 2 module complete all as specified and directed by Engr in charge.
15Supply and fix Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed complete all as specified and directed by Engr in Charge.
16Supply and fix Modular white cover plate with Frame 2 Module complete all as specified and directed.
17Supply and fix Modular white cover plate with Frame 3 Module complete all as specified and directed.
18Supply and fix Modular white cover plate with Frame 4 Module complete all as specified and directed.
19Supply and fix Modular white cover plate with Frame 6 Module complete all as specified and directed.
20Supply and fix Modular white cover plate with Frame 8 Module complete all as specified and directed.
21Supply and fix Modular white cover plate with Frame 12 Module complete all as specified and directed.
22Supply and fix Modular metal flush box 2 module including cutting, chassing, filling putti & good make of distrubed surface and matching with existing colour complete all as specified and directed.
23All as per item No 17 but metal flux box 3 module.
24All as per item No 17 but metal flux box 4 module.
25All as per item No 17 but metal flux box 6 module.
26All as per item No 17 but metal flux box 8 module.
27All as per item No 17 but metal flux box 12 module.
28Supply and fix in repair Polymer extruded channel, with opaque diffuser for glare free light 1x18/20 WH 04 feet long accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size with all accessories complete all as specified and directed.
29Supply and fix Polymer extruded channel, with opaque diffuser for glare free light 1x10 WH 02 feet long accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size with all accessories complete all as specified and directed.
30Earthing complete with galvanized steel earth plate electrode 600x600x6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead strip of 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC 1:2:4 in pit with pre- cast RCC 1:2:4 cover reinforced with XPM not less than 4 Kg Sqm, test point etc. all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal to a distance not exc. 50m, testing on completion complete all as specified and directed by Engineer-in-Charge
31Supply and fixing Recess Mounting LED down lighter with pressure die cast aluminum heat sink and PC diffuser 22/24 Watt capacity (minumum lumen 120/watt) environment friendly , new generation, asthetically designed ultra modern, fully diffused, white powder coated complete with integrated driver incl all accessories suitable for Armstron/ Grid Ceiling all as specified and directed.
32Supply and fixing Recess Mounting LED down lighter with pressure die cast aluminum heat sink and PC diffuser 15 Watt capacity (minumum lumen 120/watt) environment friendly , new generation, asthetically designed ultra modern, fully diffused, white powder coated complete with integrated driver incl all accessories suitable for Armstron/ Grid Ceiling all as specified and directed.
33Supply and fixing Recess Mounting LED down lighter with pressure die cast aluminum heat sink and PC diffuser 9 Watt capacity (minumum lumen 120/watt) environment friendly , new generation, asthetically designed ultra modern, fully diffused, white powder coated complete with integrated driver incl all accessories suitable for Armstron/ Grid Ceiling all as specified and directed.
34Supply and fixing Recess Mounting LED down lighter with pressure die cast aluminum heat sink and PC diffuser 7 Watt capacity (minumum lumen 120/watt) environment friendly , new generation, asthetically designed ultra modern, fully diffused, white powder coated complete with integrated driver incl all accessories suitable for Armstron/ Grid Ceiling all as specified and directed.
35Supply and fix in rapair Plug and Socket enclosure, in sheet metal enclosure with MCB, SP 20 Amps 240 Volts complete with metal clad socket for window type air conditioners or geyser complete all as specified and directed by Engr in Charge.
36Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces complete all as specified and directed by Engr in Charge.
37Supply and fix submain wiring with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing and caping of suitable dia, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing. Note :- (i) Two runs of 4Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm cable shall be measured as 1 RM.(ii) Each submain wiring shall run in seperate PVC casing caping
38All as per item No 32 but 2.5 Sqmm sub main wiring complete all as specified and directed by Engr in Charge.
39All as per item No 32 but 1.5 Sqmm sub main wiring complete all as specified and directed by Engr in Charge.
40Supply and fix in repair sheet metal enclosure 12 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed by Engr in Charge.
41Supply and fix in repair sheet metal enclosure 8 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed.
42S&F in repair MCB SPN (DP) 40 to 63 Amps, 240 Volts, 'C' curve, 10 KA complete all as specified and directed by Engr in Charge.
43S&F in repair MCB SP 6 to 32 Amps, 240 Volts, 'C' curve, 10 KA complete all as specified and directed by Engr in Charge.
44S&F in repair MCB TPN (four pole) 40 to 100 Amps, 240 Volts, C curve, 10 KA complete all as specified and directed by Engr in Charge.
45Supply and fix in repair LED lamp suitable for 14 watts, 240 volts, single phase, 50 Hz, Lumen 1450 AC supply complete all as specified and directed.
46Material and Labour in repair for Lamp holder, PVC /Polycarbonate type with cord grip cap suitable for pendant fittings complete all as directed by Engineer-in-Charge.
47Supply and fixing in repair GI strip 32/6 for building earthing and sadling in high rise bldg wall (G+ 7 floor), cable trunch, building cable duct from the LT panel to DB up to height of 50 RM from ground and fix properly all as directed by Engr-in-Charge
48Supply and fix in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
49Supply and fix in repair driver for 2 x 2 feet led ceiling light 36 to 40 watt of suitable size and capacity as per existing make of light (Havells/Philips/Bajaj/Cromption/Wipro) complete all as specified and directed by Engr in Charge.
50Supply and fix in repair Linear Aluminium Baten, inbuilt sensor based on smart LED auto dimmable from 100% of rated wattage to 30% on sensing of movement/occupancy, baten 10W Aluminium Extruded Chanel Powder Coated with opaque diffuser for glare free light complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified.
51S&F in replacement PVC non-metallic double locked casing ISI marked upto 25 mm with accessories fixed in wall/ceiling/truss including cutting chases as per site requirement complete all as specified and directed by Engr in Charge.
52Supply and fix in repair single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 Sqmm in existing PVC casing caping/ new as per site requirement complete all as specified and directed by Engr in Charge.
53Supply and fix in repair single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 2.5 Sqmm in existing PVC casing caping/ new as per site requirement complete all as specified and directed by Engr in Charge.
54Refixing of existing PVC casing caping with suitable size of screws and making the disturbed surface good complete all as specified and directed by Engineer in charge.
55Supply and fixing in repair 1X50 sq mm copper conductor with 0.5 mm thick PVC sheathed cable complete all as directed by Engr-in Charge.
56S&F in repair Switch 5/6 Amps piano type, single pole 230 Volts complete all as specified and directed
57S&F in repair Switch socket combination 2 in 1, 6A flush type ISI marked complete all as specified and directed.
58S&F in repair Switch socket combination 3 pin 16A, flush type complete all as specified and directed.
59M & L for maintainance free enviroment friendly earth electrode set comprising of 17.2mm dia,3 mtrs long rod of low carbon steel molecular copper bounded for a thickness of 250 micro ohms, highly conductive ANSI/NSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 lbs) including taking down old earthing complete all as directed by Engr-in Charge.
60Supply and fixing in repair 120 WATT LED highbay/midbay intergral industrial high power LED High/midbaywith pressuredie cast alluminium housing anodrised aluminium reflector at any complete with all acessories.
61Supply and fixing in repair 150 WATT LED highbay/midbay intergral industrial high power LED High/midbaywith pressuredie cast alluminium housing anodrised aluminium reflector at any complete with all acessories.
62Supply and fix in repair LED 1 x 16/18 W flame proof fitting complete all as specified and directed by Engr in Charge.
63Supply and fix in repair flame proof switch rotary type 06 Amp single pole fix to wall complete all as specified and directed.
64Supply and fix in repair flame proof distribution board of size 275 mm x 275mm x 130 mm including MCB SPN 32 Amps - 01 Nos , MCB SP 6 -32 Amps -06 Nos at nearest site suitable for in coprating MCB SPN & SP Etc complete all as specified and directed by Engr in Charge.
65S&F in replacement PVC hylum sheet 3mm thick top cover of size 250 x 200 x 3 mm all as specified and as directed by Engineer-in charge.
66S&F in replacement PVC hylum sheet 3mm thick top cover of size 175 x 100 x 3 mm all as specified and as directed by Engineer-in charge.
67S&F in replacement PVC hylum sheet 3mm thick top cover of size 100 x 100 x 3 mm all as specified and as directed by Engineer-in charge.
68S&F in replacement flexible wire 2 core copper size 23/0.0076 sqmm complete all as specified and directed by Engineer-in charge.
69Supply and fix in repair PVC Round sheathed 50 sqmm 4 core bright annealed bare copper conductor heavy duty industrial flexible cable 1100 volts confirming to IS 694:2010 complete all as specifed and directd by Engr in Charge.
70Taking down unserviceable and Supply and fixing CPT Cirprotec CPT-L ESE lightning rod with stainless steel body Type Advance lightning protection system in compliance with standard NFC 17-102 & UNE 21186-96, working on the principle of Early Streamer Emission technology which will offer Level 1 protection for up to 30 Mtrs Mtrs radius when mounted on the RCC concrete base on Building at a height of 4.5 mtrs from the place to be protected complete all as directed by Engr-in Charge.
71Taking down unserviceable mounting str and Supply and fixing mounting structure of 4.5 mtrs height with base plate suitable for roof mounting on RCC concrete base on Building complete all as directed by Engr-in Charge
72Taking down Old Unserviceable battery and supply and fixing new SMF battery having 30 Miniuts backup 12 Volt 26 AH SMF batteries with battery links complete all as specifed and directed by Engr in Charge.
73Taking down Old Unserviceable battery and supply and fixing new SMF battery having 30 Miniuts backup 12 Volt 42 AH SMF batteries with battery links complete all as specifed and directed . Make Exide/Amron
74Supply and fix in repair Mild Steel Galvanized Coating Powder Coated Cable Tray with top cover single compartment of size 300 mm x 50 mm x 2.0 mm for carrying of LT cable of suitable size fixing on wall/ angle iron along with all necessary fixing accessories ( bracket, nut bolts, washer, fastner) all as spcified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information
75Supply and fix in repair Mild Steel Galvanized Coating Powder Coated Cable Tray with top cover single compartment of size 300 mm x 50 mm x 2.0 mm for carrying of LT cable of suitable size fixing on wall/ angle iron along with all necessary fixing accessories ( bracket, nut bolts, washer, fastner) all as spcified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57229101
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49 Lakhs
LAST DATE 14-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement Of Internal Wiring/ Electrical Fitting/ Fixtures Including Controls, Motion Sensor Lights & Repair / Servicing Of Fan And Geysers At Various Location At installation Shikra & Other Connected Area Under Ge (Nw) Nofra.
Basic Detail
Tender No GE (NW) NOFRA 8563
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 27 Aug 2026
Submission Date 14 Sep 2026
Open Date 16 Sep 2026
Finance
Tender Value 49 Lakhs
Tender Fee 500
EMD 98000
Exemption Available
Document List
52fb8642-098a-478d-b685-bf7f54bfd6db.html
BOQ_881550.xls
Tendernotice_1.pdf
TenderPages8563.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Sep 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

52fb8642-098a-478d-b685-bf7f54bfd6db.html

xls

BOQ_881550.xls

pdf

Tendernotice_1.pdf

pdf

TenderPages8563.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail