Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #57229098

Tender For Repair/Maintenance Of Internal Electrification, Security Light, Control Panel, Cable, High Mast Light And Distribution System For Security Light, Garden Light, Earthing And Lighting Arrester And Connected Items, Dg Set And Amf Panel Alongw

Issued by Statutory Bodies & Commissions/Committees · Thane, Maharashtra
Tender Value
22.50 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
14 days left
EMD
45000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thane → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maintenance Of Internal Electrification, Security Light, Control Panel, Cable, High Mast Light And Distribution System For Security Light, Garden Light, Earthing And Lighting Arrester And Connected Items, Dg Set And Amf Panel Alongwith Fire Fighting Equipments At Af Stn Madh Island Under Ge (Af) Thane

BOQ

Name of Work:- REPAIR/MAINTENANCE OF INTERNAL ELECTRIFICATION, SECURITY LIGHT, CONTROL PANEL, CABLE, HIGH MAST LIGHT AND DISTRIBUTION SYSTEM FOR SECURITY LIGHT, GARDEN LIGHT, EARTHING AND LIGHTING ARRESTER AND CONNECTED ITEMS, DG SET AND AMF PANEL ALONGWITH FIRE FIGHTING EQUIPMENTS AT AF STN MADH ISLAND UNDER GE (AF) THANE
Sl. No. Item Description
1Excavation in trenches n. exc. 1.5 M in width and 1.5 M in deep for laying of pipes and getting out in Soft / loose soil complete all as specified and directed by Engineer-In-Charge.
2Excavation in trenches n. exc. 1.5 M in width and 1.5 M in deep for laying of pipes and getting out in hard /dense soil complete all as specified and directed by Engineer-In-Charge.
3Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm complete all as specified and directed by Engineer-In-Charge.
4Removing excavated material n. exc. 50 M away, depositing as directed at level n. exc. 1.5 M above starting point complete all as specified and directed by Engineer-In-Charge.
5Supply and spreading in trenches clear dry sand for cable protection and punning down gently 10 cm below the cable and 15 cm above the cable all as specified and directed by Engineer-In-Charge.. Note :- Punning thickness only measured.
6Takingout old unreinforced precast concrete cable coverclass LV type1 flat size 250x150x40 mm during excavation of trenches complete all as specified and directed by Engineer-In-Charge.
7S&F unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm during excation of trenches all as specified and directed by Engineer-In-Charge.
8Taking down GI pipe laying in trenches for UG cable protection of any sizes pipe complete all as specified and as diercted by Engineer-In-Charge.
9Supply and lay in trenches / along the wall / floor pipes GI light grade of size 80 mm with and including all fittings and accessories complete all as specified and and directed for cable protection complete all as specified and directed by Engineer-In-Charge.
10Supply and lay in trenches / along the wall / floor pipes GI light grade of size 40 mm with and including all fittings and accessories for cable protection complete all as specified and directed by Engineer-In-Charge.
11Supply and lay 80 mm outer dia double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cables with all fittings. laid in trenches / road or fixed along wall. poles or laid under floor and making good to match with existing adjoining surface etc for cable protection all as specified complete all as specified and as directed by the Engineer-In-Charge.
12Taking down any sizes of of LT UG cable XLPE with aluminum conductor multistranded , PVC insulated and PVC sheeted heavy duty 1100 Volts grade under ground cable complete all as specified and as directed by Engineer-in-Charge.
13Supply and lay cable XLPE Insulated armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 10 sq mm 2 Core complete all as specified and directed. ,complete all as specified and as directed by the Engineer-In-Charge.
14Supply and lay cable XLPE Insulated armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 16 sq mm 2 Core complete all as specified and directed by Engineer-in-Charge.
15Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 16 sq mm 4 Core complete all as specified and directed by Engineer-in-Charge.
16Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 25 sq mm 4 Core complete all as specified and directed by Engineer-in-Charge.
17Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 35 sq mm 3.5 Core complete all as specified and directed by Engineer-in-Charge.
18Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 95 sq mm 3.5 Core complete all as specified and directed by Engineer-in-Charge.
19Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 70 sq mm 3.5 Core complete all as specified and directed by Engineer-in-Charge.
20Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 50 sq mm 3.5 Core complete all as specified and directed by Engineer-in-Charge.
21Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 120 sq mm 3.5 Core complete all as specified and directed by Engineer-in-Charge.
22S&F copper cable flexible PVC insulated 3 x 2.5 sqmm single core along with earth wire in PVC conduit from FRP box to flood light/street light fitting ,including aluminium flat clamp 25 X 4 mm with suitable nuts,bolts and washers etc all as specified and directed by Engineer-in-Charge.
23S&F copper cable PVC round sheathed (flexible) industrial cable 4 core x 10.0 sqmm for high mast lights/street light maintenance all as specified and directed by Engineer-in-Charge.
24M&L cable jointing kit for 1100 volts grade cable for straight through heat shrinkable type joint, complete with and including jointing material and accessories suitable for 3.5 core XLPE armoured aluminium cable of size 25 Sqmm to 50 Sqmm, also with and including connecting single ferrules/thimbles etc after disconnecting of electric supply including burnt out jointing kit etc, complete all as specified and directed by Engineer-in-Charge.
25M&L cable jointing kit 1100 volts grade cable for straight through heat shrinkable type joint, complete with and including jointing material and accessories suitable for 3.5 core XLPE armoured aluminium cable of size 70 Sqmm to 95 Sqmm, also with and including connecting single ferrules/thimbles etc after disconnecting of electric supply including burnt out jointing kit etc, complete all as specified and directed by Engineer-in-Charge.
26M&L for cutting existing road/hard standing not exc 50x60 cm in wide & depth getting out excavated material for laying GI tube , for passing through LT cable, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:1.5:3; including removal of surplus soil complete all as specified and directed by Engineer-in-Charge.
27Demolition of Cement concrete in ground floor and paving n.exc 15 cm thickness (below or above) ground level including removal all as specified and directed by Engineer-in-Charge.
28M&L for PCC (1:3:6) type C2 (using 20 mm graded stone aggregate as in sub base to floor 100 mm thick finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge).
29Taking down any type any breaking capacity MCCB complete all as specified and as directed by Engineer-in-Charge.
30S & F in replacement MCCB 415 volts grade with adjustable short circuit and over load of following rating :-
3163 Amps, 16 KA, 3 Pole, complete all as specified and as directed by Engineer-in-Charge.
32100 Amps, 16 KA, 3 Pole, complete all as specified and as directed by Engineer-in-Charge.
33125 Amps, 16 KA, 3Pole, complete all as specified and as directed by Engineer-in-Charge.
34160 Amps, 36 KA, 3 Pole, complete all as specified and as directed by Engineer-in-Charge.
35200 Amps, 36KA, 3 Pole, complete all as specified and as directed by Engineer-in-Charge.
36Supply and fixing in repairs/Replacement of the undermentioned items to be incorporated in street light fittings including taking down street light from pole and refixing it on pole after replacement of driver complete all as specified and directed by Engineer-in-Charge.
37LED Driver for 1 x 60 watt LED street light, complete all as specified and as directed by Engineer-in-Charge.
38LED Driver for 1 x 90 watt LED street light, complete all as specified and as directed by Engineer-in-Charge.
39LED Driver for 1 x100 watt LED flood light, complete all as specified and as directed by Engineer-in-Charge.
40LED Driver for 1 x200 watt LED flood light , complete all as specified and as directed by Engineer-in-Charge.
41S & F in replacement street light timer, single phase for 8 KW light load comprising of nature switch, contactor and MCB housed in a pole mountable enclosure complete all as specified and directed by Engineer-in-Charge.
42Supply and fixing in replacement LED street light fitting 90 Watt 230 V, surge protection 10 KVA, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer-in-Charge.
43Supply and fixing in replacement LED street light fitting 60 Watt 230 V, surge protection 10 KVA, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer-in-Charge.
44Supply and fixing in replacement post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.complete all as specified and directed , complete all as specified and as directed by Engineer-in-Charge.
45Supply & fixing in replacement LED land scape light/bollard light/garden light with excellent light output through its sleek PMMA window ensuring max illumination aspect in surrounding, 10W/9 W with 900mm height extruded aluminium cylindrical section housing IP-65 rated complete with base & log bolt grafite grey epoxy cationic powder coated all accessories including PCC foundation for fixing arrangement on ground complete all as specified. and directed . complete all as specified and directed by Engr-in-charge.
46S&F copper cable flexible PVC insulated 3 x 1.5 sqmm single core along with earth wire in PVC conduit from FRP box to street light fitting ,including aluminium flat clampt 25 X 4 mm -03 Nos with suitable nuts,bolts and washers etc all as specified and directed by Engineer-in-Charge.
47S&F copper cable PVC round sheathed (flexible) industrial cable 4 core x 6.0 sqmm for high mast lights/street light maintenance all as specified and directed by Engineer-in-Charge.
48Supply and fixing in replacement LED street light fitting 45 Watt 230 V, surge protection 10 KVA, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer-in-Charge.
49Supply & Fix in Replacement of GI Bracket made out of 40 mm dia medium grade GI tube up to 1.5 m long bend to shape 115 degree off set shape, fixed with 2 nos of suitable MS Flat clamp of size 40x5 mm with necessary nut bolts & washers and applying two coats of synthetic enameled paint over one coat of zinc oxide primer for clamp complete all as specified and directed by Engineer-in-Charge.
50Material and Labour for painting of Pre-stressed concrete pole 7.5 mtr long with one coat of white colour weatherproof snowsum paint including numbering of pole no with black oil paint ,incl 2 strips of white & yellow paint , alternate upto a height of 1.2 mtrs complete all as specified and directed by Engineer-in-Charge.
51Supply and fix in replacement FRP cable looping box of size 250mm x 150mm x 100mm With connector block 4 Way , 1 Nos of MCB SP 6 Amp 10KA, etc including suitable Brass gland, including provision for connecting earth continuity conductor etc. all as specified and directed by Engineer-in-Charge.
52Material and labour for lowering of LED light fiitings mounting ring 20 Mtr to 30 Mtrs height carefully with help of highly skilled electrician and labours to mannually/electrically, Servicing Repair and replacement of spares of forward/reverse operation induction motor 3 phase 415 volts 2 HP capacity including winding,greasing and oiling. Servicing of forward/reverse operation Gear box including greasing and oiling, dismantling and taking chain of motor to gear box, taking down unserviceable LED Light fittings and replacement of Suitable drivers of existing capacity/ Make its serviceable,supply and replace wire rope for lift side for suitable gauges/size,replacement of timer with power contactor three phese 415 volts AC 32 Amps capacity, After repairing of LED light fittings tesiting and make serviceable of all fittings and lifting of mounting rings to existing places, After repairing of LED light fittings tesiting and make serviceable of all fittings and lifting of mounting rings to existing places complete all as specified and directed by Engineer-in-Charge.
53Supply & Fix in replacement LED flood light fitting 210 Watts , 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant ,Pressure die cast aluminium housing, heat resistant toughened glass with frame, uniform distribution ,including fixing arrangments with angle iron and suitable nut,bolt,washer etc on wall /on pole complete all as specified and as directed by Engineer-in-Charge.
54Supply & Fix in replacement LED flood light fitting 120 Watts , 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant ,Pressure die cast aluminium housing, heat resistant toughened glass with frame, uniform distribution ,including fixing arrangments with angle iron and suitable nut,bolt,washer etc on wall /on pole complete all as specified and as directed by Engineer-in-Charge.
55Maintenance for DG Set 250 KVA, Make - Crompton Greaves, through authorised service agency of OEM , Location :(DG SET -1, Radar Area AFS Madh) complete all as directed Note :- Spares required for above maint will be measured and paid separately under relevent items involving the following scope of works :-
56(I) Scope of works :- (a) Check the sample of coolent concentration. (b) Check the fan belt for tension and replace if needed. (c) Check exhaust condensate drain and remove any debris or dust. (d) Examine the charge level of battery and check for any loose connection and de-scale carbon deposits if any on terminals and application petroleum jelly. (e) Check the air cleaner components and clean the dirt with air pressure. (f) Check and adjust the voltage level of the battery charger. (g) Drain out the water from the container of the bottom of the filter housing and fuel tank. (h) Check the control panel wiring, Instrumentation, contacts fuses, etc. (j) Check the specific gravity of battery every month and condition of Plates once in three months. (k) Check the service ability of safety controls of Engine. (l) Checking of all electricalconnectons for its proper tightness. (m) Check AVR connections & power cable connections for tightness. (n) Check RPM/Frequency and adjust it. (o) Checking of Load balancing of alternator/AMF panel output. (p) Check the condition wire breaded / nonbreaded hoses of engine. (II) In addition to above the following checks will be carried out by contractor in six monthly :- (a) Replace the fuel filter and oil filter. (b) Clean the crank case breather. (c) Check the radiator hoses. (III) In addition to above the following checks will be carried out by contractor annually :- (a) Greasing of Alternator Bearing. (b) Cleaning the diesel tank. (c) Check the installation. (d) Checking of exhaust back pressure. (e) Checking of temperature of exhaust. (f) Check the performance of radiator. (IV) Unit rates quoted shall be inclusive of the following : - (a) Checking of all rotary and stationery parts of engine and adjust/repair the defects as required for satisfactory running of DG set. (b) Cleaning and refitting the air cleaner. (c) Cleaning of fuel filter assembly and replacement of filter element along with rubber 'O' ring. (d) Replacement of 'V' belt for driving radiator fan/ water Pump/Battery charger alternator with proper adjustment. Repair to nozzle by replacement plunger & spring valves. Replacement of high pressure stainless steel tubing not less than 1 m length from FIP to nozzle including Benjoo bolts, copper washer etc. Replacement of upper gasket kit. (e) Renewal of oil filter elements including checking of serviceability of lubricants oil pump and repair where necessary for proper oil pressure. (f) Drain out the lub oil and refill new oil after proper cleaning. (g) Checking and adjustment of tappet clearance. Note :- (i) In case of any breakdown service engineer shall attend the break down immediately and make the DG Set Serviceable within 24 working hrs. (ii) Repair, if any must be carried by Contractor through authorised workshop of original manufacturer and Payment will be made to the contractor on Produce of Original Manufacturer's Bills/vouchers.
57Ditto - all as per item No -46 here-in-before but for 125 KVA DG Sets Power House DG -1 & Power House DG-2) complete all as directed by Engineer-in-Charge.
58Ditto --all as per item No -46 here-in-before but for 82.5 KVA DG Sets ( AFNET SUB station DG -1 & AFNET SUB station DG-2) complete all as directed by Engineer-in-Charge.
59Ditto --all as per item No -46 here-in-before but for 62.5 KVA DG Set ( Near SMC Hall station DG -1 ) complete all as directed by Engineer-in-Charge.
60Draining out the old sludgs oil from the DG set and replace with new oil as recommended by Mfg complete all as directed by Engineer-in-Charge.NOTE : Draining out of Oil shall be done twice in year each time reffiling/Top up )
61Supply and fixing for Industrial Battery of 12 Volt,180 AH capacity suitable for 82.5 to 250 KVA DG Sets heavy duty, 25 plates includidng removing existing unserviceable battery from existing places and cleaning of battery terminals and clamps properly and refixed and reconnected complete all as specified and directed by Engineer-in-Charge.
62Servicing of AMF Panel suitable for 62.5 KVA DG Set to 250 KVA DG Set including cleaning properly with blower, checking of control wiring , replacement of burnt out / damaged wiring connections, calibration of control relay, replacement of control fuses / MCBs complete all as specified and directed by Engineer-in-Charge.NOTE :- Spare parts shall be measured and paid sepretely in resppective item of this schedule if required.
63Supply only for LED type Indicator indication lamps R,Y,B) complete all as specified and directed by Engineer-in-Charge.
64Supply only for Push Buttons start on off switch with element complete all as specified and directed by Engineer-in-Charge.
65Supply only for Control relay 9/11 pin 12 /24 volt DC of suitable for 62.5 KVA to 125 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
66Supply only for Digital ammeter with bilt in selector switch complete all as specified and directed by Engineer-in-Charge.
67Supply only for CT of ratio upto 150 / 5 10 VA burdan complete all as specified and directed by Engineer-in-Charge.
68Supply only for HRC fuse 200 Amp complete all as specified and directed by Engineer-in-Charge.
69Supply only for PVC insulated & unsheathed singal core multi strandred copper cable of size 4 sq mm for control wiring complete all as specified and directed by Engineer-in-Charge.
70Supply only for PVC insulated & unsheathed singal core multi strandred copper cable of size 2.5 sq mm for control wiring complete all as specified and directed by Engineer-in-Charge.
71Supply only for PVC insulated & unsheathed singal core multi strandred copper cable of size 1.5 sq mm for control wiring complete all as specified and directed by Engineer-in-Charge.
72Material and Labour in repairs of Temperature gauge complete all as specified and directed by Engineer-in-Charge.
73Material and Labour for servicing of Turbo charger including Replacemnt of Turbo charger kit for capacity 250KVA /125 KVA/82.5KVA/62.5KVA complete all as specified and directed by Engineer-in-Charge.
74Material and Labour in Servicing of Self Starter 24 Volt DC for 250 KVA DG Set, dissmantling complete,& replacement of solenoid field coils. cleaning the cummutator strips including replacing the bearing, bends pinion re-assembling, connecting and testing complete all as specified and directed by Engineer-in-Charge.
75Ditto all as per item No 64 here-in- before but for capacity 125 KVA DG set c complete all as specified and directed by Engineer-in-Charge.
76Ditto all as per item No 64 here-in- before but for capacity 82.5 to 62.5 KVA DG set complete all as specified and directed by Engineer-in-Charge.
77Material and Labour for replacement of u/s contactor 415 V AC supply 4 pole suitable for 250 KVA DG Set including all accessories complete all as specified and directed by Engineer-in-Charge.
78Material and Labour for in repairs of Feed Pump for Aquastic DG set for capacity 62.5 to 82.5 KVA complete all as specified and directed by Engineer-in-Charge.
79Dis-connecting the alternator from the engine of capacity 250 KVA by removing the coupling & outgoing cable transporting the alternator to authorized maintenance service center for repairsCleaning the armature, applying one coat of varnish and heating and assembling the alternator at workshop and testing at NO load, transporting the same to the site , re-connecting the alternator to the engine after proper alignment including testing and commissioning complete all as specified and directed by Engineer-in-Charge.
80Ditto all as per item No 69 here-in- before but for 125/ 82.5 KVA DG Sets complete all as specified and directed by Engineer-in-Charge.
81Material and Labour in taking down carefully Old rusted silencer & exhaust pipe from engine scraping & cleaning in side & out side applying one coat of zink primer for out side silencer pipe & providing self adjestive Asbasto Rope 12 mm dia from engine to exhaust pipe and painting with 2 coat of syenthetic enameled paint for expose portation of exhaust complete all as specified and directed by Engineer-in-Charge.
82Material and Labour scraping the peeled paint of DG set, preparing the surfaces, cleaning the dust and dirt etc of (alternator and engine) applying 2 coats of synthetic enamel paint of approved shade and writing of MES/SM No on the set all as directed of capacity 250/125/82.5/62.5 KVA complete all as specified and directed by Engineer-in-Charge.
83Supply only solenoid Switch 12 Volt DC complete all as specified and directed by Engineer-in-Charge.
84Supply only Battery terminal Heavy duty made of brass with nut and bolt including washers suitable for 12 volt DC battary complete all as specified and directed by Engineer-in-Charge.
85Supply only Radiator Hose pipe as per existing set for 62.4/82.5 KVA complete all as specified and directed by Engineer-in-Charge.
86Supply only Door hinges assembly for Aquastic DG set complete all as specified and directed by Engineer-in-Charge.
87Supply only Heavy duty Automatic electronic battery charger suitable for 12/24 Volt DC complete all as specified and directed by Engineer-in-Charge.
88Supply only Ignition Switch for capacity up to 250,125,82.5 KVA DG set complete all as specified and directed by Engineer-in-Charge.
89Supply only solenoid Switch 24 Volt DC for 125/250 KVA DG Set as per existing complete all as specified and directed by Engineer-in-Charge.
90Supply only Coolant premix as manufafacture recommendations and required for top up for Accostic DG set complete all as specified and directed by Engineer-in-Charge.
91Supply only refilling of distilled water for top up battary 12 volt DC complete all as specified and directed by Engineer-in-Charge.
92Supply only Air Filter inside & out side for capacity 250 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
93Supply only Primary Fuel Filter for capacity 250 KVA DG set complete all as specified and directed by Engineer-in-Charge.
94Supply only Secondray Fuel Filter for capacity 250 KVA DG set complete all as specified and directed by Engineer-in-Charge.
95Supply only Lubricating Oil Filter for capacity 250 KVA DG set complete all as specified and directed by Engineer-in-Charge.
96Supply only Fuel pipes with benjo bolt and washers.For capacity 250 KVA DG set complete all as specified and directed by Engineer-in-Charge.
97Supply ony V- Belt as per existing size for capacity 250 KV DG set complete all as specified and directed by Engineer-in-Charge.
98Supply only Air Filter inside & out side for capacity up to 125 KVA DG set complete all as specified and directed by Engineer-in-Charge.
99Supply only Primary Fuel Filter for capacity up to 125 KVA DG set complete all as specified and directed by Engineer-in-Charge.
100Supply only Lubricating Oil Filter for capacity up to 125 KVA DG set complete all as specified and directed by Engineer-in-Charge.
101Supply only Primary Fuel Filter for capacity for 62.5/82.5 KVA DG set complete all as specified and directed by Engineer-in-Charge.
102Supply only Secondary fuel filter for capacity for 62.5/82.5 KVA DG set complete all as specified and directed by Engineer-in-Charge.
103Supply only lubricating Oil Filter for capacity 62.5/82.5 KVA DG set complete all as specified and directed by Engineer-in-Charge.
104Supply only super by pass oil filter for 125 KVA DG set complete all as specified and directed by Engineer-in-Charge.
105Supply only Fuel pipes for capacity up to 125 KVA DG set complete all as specified and directed by Engineer-in-Charge.
106Supply only Vee Belt as per existing size for capacity up to 125 KVA DG set complete all as specified and directed by Engineer-in-Charge.
107Supply only fuel governing controler for 250 KVA DG set complete all as specified and directed by Engineer-in-Charge.
108Supply only Coolant hose set suitable for 250 KVA DG set complete all as specified and directed by Engineer-in-Charge.
109Supply only Coolant hose set suitable for 125 KVA DG set complete all as specified and directed by Engineer-in-Charge.
110Supply only Coolant hose set suitable for 82.5 KVA DG set complete all as specified and directed by Engineer-in-Charge.
111Supply only Coolant hose set suitable for 62.5 KVA DG set complete all as specified and directed by Engineer-in-Charge.
112Supply only Fuel hose set suitable for 250 KVA DG set complete all as specified and directed by Engineer-in-Charge.
113Supply only Fuel hose set suitable for 82.5 KVA DG set complete all as specified and directed by Engineer-in-Charge.
114Supply only Fuel hose set suitable for 62.5 KVA DG set complete all as specified and directed by Engineer-in-Charge.
115M&L in repairs for Earth continuity conductor or main earthing lead fixed to wall on batten/saddles or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 4 mm GI Wire complete all as specified and directed by Engineer-in-Charge.
116Taking down old GI strip/Copper Strip of any type and size complete all as specified and directed by Engineer-in-Charge.
117M&L for Earth continuity conductor or main earthing lead fixed to wall on batten/saddles or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 32x6mm GI Strip complete all as specified and directed by Engineer-in-Charge.
118M&L for Earth continuity conductor or main earthing lead fixed to wall on batten/saddles or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 25x3 mm Aluminium Strip complete all as specified and directed by Engineer-in-Charge.
119M&L for Earth continuity conductor or main earthing lead fixed to wall on batten/saddles or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 32 x 6mm copper Strip complete all as specified and directed by Engineer-in-Charge.
120M&L for Earth continuity conductor or main earthing lead fixed to wall on batten/saddles or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 20 x 3 mm Copper Strip complete all as specified and directed by Engineer-in-Charge.
121Supply and fix in repairs Test point terminal block made up of gunmetal or phosphorus bronze 75mmx75mmx25mm drilled and screws including 8mm dia 25mm long hex head screws and connecting to earth strip complete all as specified and directed by Engineer-in-Charge.
122M & L Chemical earthing with copper pipe electrode 3 mtr long having outer dia 80 mm inner pipe dia 50 mm duly filled with highly conductive and anticorrosive compound of required quantity having chemical composition Bentonite 40%, Copper sulfate 10%, Gypsum 5% Graphite 10%, Alum 5% Zink sulfate 10%, Aluminum sulfate 10% buried in ground by digging a bore of 50 mm dia surrounded by soil friendly back fill compound not soluble in water including connection with galvanized earth strip 32x6 mm, making PCC pit of size 0.3 mtr x 0.3 mtr x 0.3 mtr (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B1, 40 mm thick cover reinforced with 6 mm dia MS bars 3 Nos both ways with lifting hook made out of 8 mm dia Bar and testing on completion to achieve value not more than 0.5 om complete all as specified and directed by Engineer-in-Charge. (Note – GI strip size 32 x 6 mm is up to 7.5 mtr length included in the item).
123M & L for Earth recharger/Earth resistance reducing compound of 6 KG per buckets comprising of ion and catalyser for reduction of earth resistance as well as retaining moisture in the earth pit with certified( ERDA, NABL, ROHS, IS3043, IEEE IS RULES) and without corroding the earth pit material suitable for all type of earth pit complete all as specified and directed by Engineer-in-Charge.Note-(a) Percentage reduction of earth resistance should be min 70 Percentage (b) Earth resistance value should be retain atleast 1.5 years.(c) contractor will submit earth resistance value before and after utilization of material.
124M&L for Brazing of copper strip joints for copper strips of any size complete all as specified and directed by Engineer-in-Charge.
125Supply and fix in repairs for the following items to be incorporated in repairs to earthings, complete all as specified and directed by Engineer-in-Charge.
126Charcoal
127Common Salt
128Funnel with wire Mesh
129Supply and fix in repairs Test point Air termination, single pointed, copper rod 12 mm dia and 300 mm long complete all as specified and directed by Engineer-in-Charge.
130Porcelain insulator with nut bolt and washer suitable for fixing copper/gi/aluminium strip on wall or ceiling, complete all as specified and directed by Engineer-in-Charge.
131M&L for PCC 1 : 3 : 6 type C1 with 20 mm stone aggregate for foundtation / concrete blocks / earthing chamber / chamber cover set in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
132Supply and fix sheet steel enclosure for test terminal block of size 150x150 mm made out of 2 mm thick dully Powder Coated CRCA sheet for fixing test terminal block complete all as specified and directed by Engineer-in-Charge.
133M&L in repairs fire alarm system conventional 4 zone FAP control panel complying complete all as specified and directed by Engineer-in-Charge.
134M&L in repairs fire alarm system conventional 16 zone FAP control panel complying complete all as specified and directed by Engineer-in-Charge.
135M&L in repairs MCP conventional ABS complete all as specified and directed by Engineer-in-Charge.
136M&L in repairs Electronic Hooter 24 Volts DC complete all as specified and directed by Engineer-in-Charge.
137M&L in repairs optical smoke detector complete all as specified and directed by Engineer-in-Charge.
138Supply and fixing PVC insulated heavy duty armoured copper conductor of size 2x1.5 sqmm cable for fire alarm complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information
139Supply and fixing PVC insulated heavy duty armoured copper conductor of size 2x1.5 sqmm cable for fire alarm complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57229098
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 22.50 Lakhs
LAST DATE 15-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance Of Internal Electrification, Security Light, Control Panel, Cable, High Mast Light And Distribution System For Security Light, Garden Light, Earthing And Lighting Arrester And Connected Items, Dg Set And Amf Panel Alongwith Fire Fighting Equipments At Af Stn Madh Island Under Ge (Af) Thane
Basic Detail
Tender No GE (AF) T- 39 OF 2026-27 (8646)
Bidding Type Tender
Location
City Thane
State Maharashtra
Key Dates
Publish Date 27 Aug 2026
Submission Date 15 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 22.50 Lakhs
Tender Fee 500
EMD 45000
Exemption Available
Document List
4a562958-e64c-48b0-be18-048e85dfff2f.html
BOQ_881578.xls
TD8646.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

4a562958-e64c-48b0-be18-048e85dfff2f.html

xls

BOQ_881578.xls

pdf

TD8646.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders