Educational and Research Institute Local Bodies Closing in 1 days TDR #57228808

Tender For Purchase Of Equipment , 3D Bioprinter , 1. General Requirements I. The Printer Must Consist Of Two Printhead Slots.,Ii. Two Printheads Compatible With 3D Printing Bioinks (Biomaterials And Cells) Must Be Supplied With The Instrument.Iii. The Sy

Issued by Local Bodies · Coimbatore, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Sep 2026
1 days left
EMD
21000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Purchase Of Equipment , 3D Bioprinter , 1. General Requirements I. The Printer Must Consist Of Two Printhead Slots.,Ii. Two Printheads Compatible With 3D Printing Bioinks (Biomaterials And Cells) Must Be Supplied With The Instrument.Iii. The System Must Support Attachment Of Various Volumes Of Temperature-Controlled Printheads. 2. Printhead Specifications System Should Support The Following Print-Heads I. Pneumatic Temperature-Controlled Printhead (3Cc),1) Syringe Volume Compatibility: 3Cc 2) Temperature Range: Room Temperature (Rt) To 60˚C,3) Temperature Precision: ±0.5˚C Or Better 4) In-Built Uv And Visible Light Photo-Crosslinking Modules Ii. Pneumatic Temperature-Controlled Printhead (5Cc),1) Syringe Volume Compatibility: 5Cc 2) Temperature Range: Rt To 60˚C,3) Temperature Precision: ±0.5˚C Or Better 4) In-Built Uv And Visible Light Photo-Crosslinking Modules Iii. Upgrade Option: User Must Be Able To Upgrade To 10Cc Syringe Configurations. Oem Shall Provide Proof Of Prior Installations. Iv. High Temperature Fdm Printhead,1) Compatible With Thermoplastics And Equivalent Materials 2) Temperature Range: Rt To 250˚C Or Higher,3) Interchangeable Nozzles: 0.2 Mm To 0.8 Mm,3. Build Platform I. X Axis: 120-130 Mm Or Better,Ii. Y Axis: 50-80 Mm Or Better,Iii. Z Axis: 50 Mm Or Better Iv. Backlash Control Mechanisms Must Be Included To Ensure Effective Movement On All Axes, With Proof Provided. V. Layer Resolution And Xy Resolution: 10 Microns,Vi. Must Allow Use Of Well Plates (Up To 12-Well), Petri Dishes (20 Mm And 60 Mm), And Glass Slides. 4. Bed Specifications I. Bed Temperature Range: Rt To 80˚C,Ii. Precision Control: ±0.5˚C Or Better,5. Accessories I. 3Cc Air Syringes With Tip Ends And End Caps - 50 Units,Ii. 3Cc Air Syringe Pneumatic Adapters - 2 Units Iii. Dispensing Needles (18, 20, 21, 22 Gauge) - 50 Units Each,Iv. Dispensing Tapered Tips (18-22 Gauge) - 50 Units Each 6. Safety Features - I. H14 Hepa Filter With Germicidal Uv Integrated Into Chassis Ii. Fail-Safe Mechanism For Faulty Uv Exposure To Ensure User Safety Iii. System Must Not Have An Inbuilt Compressor; A Separate 3L External Oil-Free Compressor Must Be Provided 7. Software I. Printer Must Be Compatible With Most Licensed And Freely Available Slicing Software For 3D Printers And Bioprinters. Ii. Oem Must Provide Licenses For Such Software. Iii. Printer Must Include Its Own Control Software With At Least Two Pre-Fed Designs: 1) One Oem-Defined Design 2) One User-Defined Design (Provided 30 Days Before Delivery) Iv. Oem Must Demonstrate Ability To Integrate User-Defined Designs Into Control Software. 8. Compliance I. Manufacturer Must Comply With Iso 9001:2015 Certification. 9. Warranty & Maintenance I. Warranty: Minimum Of 24 Months Comprehensive Warranty Covering All Parts, Labor, And Service. Ii. Preventive Maintenance: Oem Must Provide At Least Two Preventive Maintenance Visits Per Year During The Warranty Period. Iii. Service Support: 1) Oem Must Ensure Availability Of Spare Parts And For At Least 10 Years Post-Installation. 2) Response Time For Service Requests Must Not Exceed 72 Hours. Iv. Training: Oem Shall Provide On-Site Training For Operators And Technical Staff At The Time Of Installation. V. Extended Warranty: Option For Extended Warranty And Annual Maintenance Contract (Amc) Must Be Offered.

BOQ

Name of Work:- Purchase of Equipment
Sl. No. Item Description
13D Bioprinter
21. General Requirementsi. The printer must consist of two printhead slots.,ii. Two printheads compatible with 3D printing bioinks (biomaterials and cells) must be supplied with the instrument.iii. The system must support attachment of various volumes of temperature-controlled printheads.2. Printhead SpecificationsSystem should Support the Following Print-HeadsI. Pneumatic Temperature-Controlled Printhead (3CC),1) Syringe Volume Compatibility: 3CC2) Temperature Range: Room Temperature (RT) to 60˚C,3) Temperature Precision: ±0.5˚C or better4) In-built UV and visible light photo-crosslinking modulesII. Pneumatic Temperature-Controlled Printhead (5CC),1) Syringe Volume Compatibility: 5CC2) Temperature Range: RT to 60˚C,3) Temperature Precision: ±0.5˚C or better4) In-built UV and visible light photo-crosslinking modulesIII. Upgrade Option: User must be able to upgrade to 10CC syringe configurations. OEM shall provide proof of prior installations.IV. High Temperature FDM Printhead,1) Compatible with thermoplastics and equivalent materials2) Temperature Range: RT to 250˚C or higher,3) Interchangeable nozzles: 0.2 mm to 0.8 mm,3. Build PlatformI. X Axis: 120–130 mm or better,II. Y Axis: 50–80 mm or better,III. Z Axis: 50 mm or betterIV. Backlash control mechanisms must be included to ensure effective movement on all axes, with proof provided.V. Layer resolution and XY resolution: <10 microns,VI. Must allow use of well plates (up to 12-well), petri dishes (20 mm and 60 mm), and glass slides.4. Bed SpecificationsI. Bed Temperature Range: RT to 80˚C,II. Precision Control: ±0.5˚C or better,5. AccessoriesI. 3CC Air Syringes with tip ends and end caps – 50 units,II. 3CC Air Syringe Pneumatic Adapters – 2 unitsIII. Dispensing Needles (18, 20, 21, 22 Gauge) – 50 units each,IV. Dispensing Tapered Tips (18–22 Gauge) – 50 units each6. Safety Features - I. H14 HEPA filter with germicidal UV integrated into chassisII. Fail-safe mechanism for faulty UV exposure to ensure user safetyIII. System must not have an inbuilt compressor; a separate 3L external oil-free compressor must be provided7. SoftwareI. Printer must be compatible with most licensed and freely available slicing software for 3D printers and bioprinters.II. OEM must provide licenses for such software.III. Printer must include its own control software with at least two pre-fed designs:1) One OEM-defined design2) One user-defined design (provided 30 days before delivery)IV. OEM must demonstrate ability to integrate user-defined designs into control software.8. ComplianceI. Manufacturer must comply with ISO 9001:2015 certification.9. Warranty & MaintenanceI. Warranty: Minimum of 24 months comprehensive warranty covering all parts, labor, and service.II. Preventive Maintenance: OEM must provide at least two preventive maintenance visits per year during the warranty period.III. Service Support:1) OEM must ensure availability of spare parts and for at least 10 years post-installation.2) Response time for service requests must not exceed 72 hours.IV. Training: OEM shall provide on-site training for operators and technical staff at the time of installation.V. Extended Warranty: Option for extended warranty and annual maintenance contract (AMC) must be offered. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57228808
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 11-09-2026
Authority
Authority Name Department Of Higher Education
Work Description Tender For Purchase Of Equipment , 3D Bioprinter , 1. General Requirements I. The Printer Must Consist Of Two Printhead Slots.,Ii. Two Printheads Compatible With 3D Printing Bioinks (Biomaterials And Cells) Must Be Supplied With The Instrument.Iii. The System Must Support Attachment Of Various Volumes Of Temperature-Controlled Printheads. 2. Printhead Specifications System Should Support The Following Print-Heads I. Pneumatic Temperature-Controlled Printhead (3Cc),1) Syringe Volume Compatibility: 3Cc 2) Temperature Range: Room Temperature (Rt) To 60˚C,3) Temperature Precision: ±0.5˚C Or Better 4) In-Built Uv And Visible Light Photo-Crosslinking Modules Ii. Pneumatic Temperature-Controlled Printhead (5Cc),1) Syringe Volume Compatibility: 5Cc 2) Temperature Range: Rt To 60˚C,3) Temperature Precision: ±0.5˚C Or Better 4) In-Built Uv And Visible Light Photo-Crosslinking Modules Iii. Upgrade Option: User Must Be Able To Upgrade To 10Cc Syringe Configurations. Oem Shall Provide Proof Of Prior Installations. Iv. High Temperature Fdm Printhead,1) Compatible With Thermoplastics And Equivalent Materials 2) Temperature Range: Rt To 250˚C Or Higher,3) Interchangeable Nozzles: 0.2 Mm To 0.8 Mm,3. Build Platform I. X Axis: 120-130 Mm Or Better,Ii. Y Axis: 50-80 Mm Or Better,Iii. Z Axis: 50 Mm Or Better Iv. Backlash Control Mechanisms Must Be Included To Ensure Effective Movement On All Axes, With Proof Provided. V. Layer Resolution And Xy Resolution: 10 Microns,Vi. Must Allow Use Of Well Plates (Up To 12-Well), Petri Dishes (20 Mm And 60 Mm), And Glass Slides. 4. Bed Specifications I. Bed Temperature Range: Rt To 80˚C,Ii. Precision Control: ±0.5˚C Or Better,5. Accessories I. 3Cc Air Syringes With Tip Ends And End Caps - 50 Units,Ii. 3Cc Air Syringe Pneumatic Adapters - 2 Units Iii. Dispensing Needles (18, 20, 21, 22 Gauge) - 50 Units Each,Iv. Dispensing Tapered Tips (18-22 Gauge) - 50 Units Each 6. Safety Features - I. H14 Hepa Filter With Germicidal Uv Integrated Into Chassis Ii. Fail-Safe Mechanism For Faulty Uv Exposure To Ensure User Safety Iii. System Must Not Have An Inbuilt Compressor; A Separate 3L External Oil-Free Compressor Must Be Provided 7. Software I. Printer Must Be Compatible With Most Licensed And Freely Available Slicing Software For 3D Printers And Bioprinters. Ii. Oem Must Provide Licenses For Such Software. Iii. Printer Must Include Its Own Control Software With At Least Two Pre-Fed Designs: 1) One Oem-Defined Design 2) One User-Defined Design (Provided 30 Days Before Delivery) Iv. Oem Must Demonstrate Ability To Integrate User-Defined Designs Into Control Software. 8. Compliance I. Manufacturer Must Comply With Iso 9001:2015 Certification. 9. Warranty & Maintenance I. Warranty: Minimum Of 24 Months Comprehensive Warranty Covering All Parts, Labor, And Service. Ii. Preventive Maintenance: Oem Must Provide At Least Two Preventive Maintenance Visits Per Year During The Warranty Period. Iii. Service Support: 1) Oem Must Ensure Availability Of Spare Parts And For At Least 10 Years Post-Installation. 2) Response Time For Service Requests Must Not Exceed 72 Hours. Iv. Training: Oem Shall Provide On-Site Training For Operators And Technical Staff At The Time Of Installation. V. Extended Warranty: Option For Extended Warranty And Annual Maintenance Contract (Amc) Must Be Offered.
Basic Detail
Tender No C7/CRTD/Biotech/CMRG/2283
Bidding Type Tender
Location
City Coimbatore
State Tamil Nadu
Key Dates
Publish Date 27 Aug 2026
Submission Date 11 Sep 2026
Open Date 12 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 21000
Exemption Available
Document List
639e18e1-6e7b-48df-9d6e-dc6817cd4ef0.html
BOQ_839674.xls
Tendernotice_1 (13).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Sep 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

639e18e1-6e7b-48df-9d6e-dc6817cd4ef0.html

xls

BOQ_839674.xls

pdf

Tendernotice_1 (13).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders