Tender For Repairing And Cleaning Of Damaged & Chocked Sewer Line In Rispana River Fromrispana Bridge (Vidhan Sabha) To Rajeev Nagar Rispana Bridge Dehradun (M.H. No 3 To 13) (Phase-2) Due To Natural Calamity (Deviyaapda Year 2025-26) In Dehradun Cit
Tender Overview
Project Description
Tender for Repairing And Cleaning Of Damaged & Chocked Sewer Line In Rispana River Fromrispana Bridge (Vidhan Sabha) To Rajeev Nagar Rispana Bridge Dehradun (M.H. No 3 To 13) (Phase-2) Due To Natural Calamity (Deviyaapda Year 2025-26) In Dehradun City, Distt- Dehradun
BOQ
| Sl. No. | Item Description |
| 1 | Excavation of earth depth upto 1.5 mt. Below G.L. for laying of sewer manholes, Gully pits, Chambers, sumps etc. in ordinary soil(earth,sand loam and clay) joints, pits, trimming, dressing, levelling refilling of trenchesincluding cutting of in 20 cm layers,watering and ramming the same including removal of surplus earth or other dismantled material up to a distance of 50 meters from the center of trenches.Excavation in soil mixed with morum,shingle,kankar requaring use of specials T&P. |
| 2 | Excavation in soil mixed with morum, shingle, kankar requaring use of specials T&P. if required |
| 3 | 0 mt to 1.5 mt B.G.L |
| 4 | 1.5 mt to 3.00 mt B.G.L |
| 5 | Depth from 3.0 upto 4.5 m |
| 6 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry,cement concrete,wood work,steel work, including T&P and scaffolding wherever necessary,sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. |
| 7 | Reinforced Cement Concrete |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Foundations, footings, bases of columns, etc. for mass concrete |
| 9 | Plain/reinforced cement concrete in substructure completeas per drawings and technical specification (For height upto 5 m) |
| 10 | R.C.C grade M 20 |
| 11 | Sewer line cleaning DI K7 1000 mm to 1200 mm dia including dismantling of sewer line cleaning properly and relaying properly true to alingment. |
| 12 | 0 - 1.5 m depth |
| 13 | 1.5 - 3 m depth |
| 14 | 3.0 - 4.5 m depth |
| 15 | Cleaning of manhole chamber upto depth of 6 mtr. |
| 16 | R.C.C Manhole Cover Slab |
| 17 | 1500 mm R.C.C Manhole raising |
| 18 | Supply of all materials stainless steel (SS-316L)strip 60mmx5mm thick included Cartage of material,Fabrication ,erection,(fixing)etc. all complete |
| 19 | Shifting of domestic water supply house connection coming in the alignment of sewer line/mahnole chamber including excavation, refilling, supply of all material, pipes, specials etc., labour, T&P and making good complete as per entire satisfaction of engineer in charge. |
| 20 | 65 mm PVC Pipe |
| 21 | 110 mm PVC Pipe |
| 22 | providing and laying in position cement concrete specified grade |
| 23 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 24 | 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 25 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 26 | Design and drawing of structure (as per requirement) and vetting |
| 27 | Environment Monitoring (Pre-construction Stage) |
| 28 | Ambient Air Quality (PM2.5, PM10, SOX, NOX, CO) |
| 29 | Surface Water quality (IS 2294) |
| 30 | Noise Levels (Day time and night time noise level (max, min & Leq levels) |
| 31 | Environment Monitoring (Construction Stage) |
| 32 | Ambient Air Quality (PM2.5, PM10, SOX, NOX, CO) |
| 33 | Surface Water quality (IS 2294) |
| 34 | Noise Levels (Day time and night time noise level (max, min &Leq levels) |
| 35 | Provision of Mobile Toilets at Work Site including maintenance till Construction Period |
| 36 | Water sprinkling to suppress dust |
| 37 | (i) Supply and commissioning of mobile toilets on wheel/ prefab toilet (2 units each Toilet and bathroom) with proper water supply and drainage system, electric supply and safe access at work site locationslocations |
| 38 | (ii) Maintenance: Daily cleaning twice a day by engaging one permanent helper |
| 39 | (iii) Painting at every six months |
| 40 | Environmental Protection, Safety, IEC and Social & Environmental Trainings |
| 41 | ESMP and OHS Training at site (1 day) |
| 42 | Labour Laws Training at site (1 day) |
| 43 | Training on sensitization on Gender issues including SEA/SH Provisions |
| 44 | GRC Meeting/Stakeholder meeting |
| 45 | Community Meeting/Public Consultation & Community Health and Safty training |
| 46 | Awareness Training for HIV/AIDS and other STDs |
| 47 | Project Information boards as per direction of Engineering Encharge |
| 48 | Portable water Quality Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender