Tender For Supply Installation Testing And Commissioning Of Fire Hydrants System At Industrial Estate Zakura.
Tender Value
91.33 Lakhs
Estimated cost
Bid Submission
10 Sep 2026
12 days left
EMD
1.82 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Supply Installation Testing And Commissioning Of Fire Hydrants System At Industrial Estate Zakura.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Installation, Testing and Commissioning of MS C Black steel pipes IS 3589 (Heavy class)of below mentioned sizes. The Job further includes all fittings like anchor fasteners, couplings, bends, elbows, flange, tees, etc. Welded or flanged joints as required, including applying with one coat of ready-mix primer, wrapping the pipe with 4mm thick wrapping tape . The Job further includes laying the pipe so that the top of the pipe is at a depth of one meter below ground level including excavating trenches (Hard/Rocky Soil) and then refilling the soil in layers not exceeding 20 cms. in depth, consolidating each deposited layer by ramming, watering etc.1) 150mm dia |
| 2 | 2) 100mm dia |
| 3 | 3) 80mm dia |
| 4 | 4) 200mm dia |
| 5 | Supply ,Installation, Testing and Commissioning of Cast iron dual plate wafer type non return valves PN 1.6 including nuts, bolts, 1.5 mm thick gasket companion flanges of below mentioned diameters 1) 150mm dia |
| 6 | 2) 100mm dia |
| 7 | Supply ,Installation, Testing and Commissioning of Cast iron butterfly valves conforming to PN1.6 I.S.13095 with \\"Lever\\" or gear operated, bolts, nuts, 3 mm thick insertion rubber gasket complete including companion flange all complete of below mentioned diameters1) 150 mm dia lever operated |
| 8 | 2) 200 mm dia gear operated |
| 9 | 3) 100 mm dia gear operated |
| 10 | 4) 80 mm dia gear operated |
| 11 | Supply ,Installation, Testing and Commissioning of Resilient rubber neoprene lined single vibration elimination connection with unit control suitable for raw water up to 45 ° C temperature working pressure 20 kg/sqcm 1) 150mm dia |
| 12 | 2) 100 mm dia |
| 13 | Supply ,Installation, Testing and Commissioning of C.I. “Y” suction strainer with stainless steel perforated sheet screen,flanged ends installed outside water tanks 1) 150 mm dia |
| 14 | 2) 100 mm dia |
| 15 | Supply, Installation, Testing and Commissioning of Cast iron sluice valves of PN 1.6 rating flanged at both ends of following sizes complete with rubber insertion, nuts, bolts and washers etc. 1) 150mm dia |
| 16 | Air cushion tank made of minimum 6 mm thick M.S. 250 mm dia× 1 meter height dished top ,made of minimum 6 mm thick M.S pipe/ plate complete with 25 m dia brass air valve .pressure type 25 mm dia with brass stop cock nipple tees elbows and all accessories as required including fixing brackets |
| 17 | Supply, Installation, Testing and Commissioning of Air Vessel |
| 18 | Single headed, ISI marked oblique pattern hydrant landing valve with 80 mm dia flanged inlet and 63 mm dia instantaneous type female outlet complete with gunmetal cap and G.I. chain, twist release type plug and all accessories as per IS:5290-1983 (Type 'A') |
| 19 | Controlled Percolating (CP) Hose ISI marked (IS:8423) 63 mm dia x 15 M long complete with instantaneous type gunmetal 63 mm dia. IS marked Male and female couplings (IS:903) bound and riveted to hose pipe with copper rivets and 1.5 mm copper wire. |
| 20 | 63mm dia short size branch pipes with 20 mm dia nozzles with 63mm instantaneous coupling ISI marked (IS: 903). |
| 21 | MS cabinet (to enclose above, draw-out/fire brigade inlet connections) fabricated from 16 g sheet with full front glass door and locking arrangement duly painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and suitably mounted on a raised masonry platform as required (Approx.0.6 m x 0.6 m x 0.45 m ) |
| 22 | Gun-metal 4-way fire brigade inlet connection of 4 nos. 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per I.S:904. (to be connected to static tank). |
| 23 | Providing and fixing of 4-way Gun-metal Fire Brigade Connection consisting of 63mm dia instantaneous type male coupling with built in check in valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per I.S:904-1983. |
| 24 | Supply, of Main electric fire Pump of capacity 1620 LPM The pump shall be single/ multi stage horizontal centrifugal type with volute bronze impeller connected to a TEFC induction motor suitable for 410/440 volts, 3 phase , 50 cycles AC supply 30 HP or as required, RPM : 2900. Motor shall be TEFC induction motor suitable for 415+10% Volts, 3 phase, 50 cycles ac supply with B class insulation and shall be designed for 35 degrees Celsius ambient temperature,75 mtr Head |
| 25 | Supply, of Diesel Engine Driven Pump of capacity 1620 LPM . The pump shall be Multi cylinder, heat exchanger cooled Diesel Engine Driven Fire Pump. The pump shall be single/ multi stage horizontal centrifugal type with pressure reducing valve complete. Head : 75 M, Capacity : 2280 LPM, HP : 55 HP or as required, No. of stages : Single/multi·RPM : 1450 (Pump and Engine), Mover : Diesel Engine |
| 26 | Supply, of Jockey Pump of capacity 180 LPM . The pump shall be single/ multi stage horizontal centrifugal type with volute bronze impeller connected to a TEFC induction motor suitable for 410/440 volts, 3 phase , 50 cycles AC supply 15HP or as required, RPM : 2900. Motor shall be TEFC induction motor suitable for 415+10% Volts, 3 phase, 50 cycles ac supply with B class insulation and shall be designed for 35 degrees Celsius ambient temperature, 75 mtr Head |
| 27 | Supply, Installation, Testing and Commissioning of Vibration elimination pads for below mentioned pumps 1) Type A (for Jockey pumps) |
| 28 | 2) Type B ( Main fire pumps) |
| 29 | 3) Type C (for diesel pump) |
| 30 | Supply, Installation, Testing and Commissioning of Diesel engine driven pump exhaust made of M.S pipe class 'A' 150 mm dia including fitting like flanges, bends, reducers ,etc. The Job includes providing and fitting of 50 mm thick glass wool insulation, aluminum cladding 22 gauge thick, fixing of silencer connection at engine exhaust necessary supports ,backfilling ,cutting and making good bird proof and weather proof flap complete in all respects as directed by site In charge |
| 31 | Designing, Supply, of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications.\\"Incomings250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-630 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 400Amps\\"OutgoingAll outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.(02 Sets)\\"\\"Jockey Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.\\"Diesel Engine Control for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required |
| 32 | Providing and fitting of Earthing with Copper earth plate 600mmx600mmx6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc including charcoal or coke and salt etc |
| 33 | Copper strip / wire of following sizes as required at site 25 x 6 mm G.I. Strip |
| 34 | Supply, Laying, Testing and Commissioning of XLPE insulated PVC inner sheathed steel armoured Al Cable of Havells make incl making of necessary connections with proper size of Al Thimbles dully crimped with crimping tool in cable trench incl excavation and refilling back with a layer of b Class bricks and sand layer on cable.1) 25 Sq mm 3.5C |
| 35 | 2) 70 Sq mm 3.5C |
| 36 | Providing and fitting of 300mm width x 50mm depth x 2mm thick perforated M.S. cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S suspenders and including painting etc. |
| 37 | Supply ,Installation, Testing and Commissioning of Dial type pressure gauge with isolation cock and connecting piping, bleed & block valve of below mentioned Dial diameter 150 mm calibration 0- 20 kgf/ sq.cm. |
| 38 | Supply ,Installation, Testing and Commissioning of Pressure switches suitable for operating with fire hydrant systems for working pressure of 0-20 Kg/cm² including electrical control wiring with suitable copper conductor PVC insulated and sheathed control cable upto control panel, connections etc |
| 39 | Supply ,Installation, Testing and Commissioning of Foot Valve1) 150mm dia |
| 40 | 2) 100 mm dia |
| 41 | Laying of piping trench of clear size 2'x 3', by way of dismantling of existing RCC path, excavation and casting of concrete block (1:2:4) and floor in 1:4:8 , |
| 42 | Providing and fixing single acting air release valve with screwed inlet 25mm dia. |
| 43 | Providing and fixing ball valve (full bore type) with plastic coated lever and screwed female ends tested to 20kg/sq.cm |
| 44 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead up to 50 meters and lift up to 1.5 m, as directed by Engineer-in-Charge. All kinds of soil :1x22’-0”x22’-0”x10’-0”=4840.00cft or 137.07³m |
| 45 | Providing and laying of stone soling hand packed including all carriage complete job.1x22’-0”x22’-0”x0’x6”=242.00 cft or 6.85³m |
| 46 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work up to plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)1x22’-0”x22’-0”x0’x4”=159.72cft or 4.52³m |
| 47 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) up to plinth levelRaft 1x21’-0”x21’-0”x0’x9”=330.75 cftWalls 2(20’-0”+18’-0”)x1’-0”x10’-0”=760.00 cftSlab 1x20’-0”x20’-0”x0’x9”=300.00 cft |
| 48 | FORM WORK Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, slab etc. for mass concrete.2x(20’-0”x20’-0”)10’-0”=800 sft2x(18’-0”x18’-0”)10’-0”=720 sft |
| 49 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more39.38@90kg/cm |
| 50 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand)2x(20’-0”x20’-0”)10’-0”=800 sft or74.34²m |
| 51 | Providing and fixing Ist quality ceramic glazed wall/floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colors, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.1x(20’-0”x20’-0”)=400 sft2x(20’-0”+20’-0”)10’-0=800sft |
| 52 | Brick work with common burnt clay bricks of class designated 75mm in super structure in 1:4 mix2x(20’-o”+18’-0”)0.9”x10’=577.50 cftD/d 2x6’-0”x5’-0”x0.9”=45 cft1x 7’-0”x4’-0”x0.9”=21.00 =66.00 cftNAD=511.50 cft or 14.57 cum |
| 53 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) above plinth levelBeam 2x20’+18’)1’x1’=76.00Lintel beam 2x20’+18’)0.9”x0.9”=42.75Slab 1x20’x20’x0.6”=200 =318.75 cft |
| 54 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more9.02cm@120kg/cum |
| 55 | Centering shuttering including shuttering propping and removal of the same2x2(20’-0”+18’-0”)1’=152 sft1x20’-0”x20’-0=400 sft =552.00 sft |
| 56 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required diameter and length (hold fast lugs or with dash fasteners shall be paid for separately): ist class imported wood2(18’-0”+20’-0”) 76 x3”x5”= 7.92 cft1(7’+7’+4’-6”)=18.50x3”x5”=1.93cftT=9.85 cft |
| 57 | Providing and fixing of door window shutters2x2x3’-6”x1’-6”=21 sft2x1x3’-6”x2’-6”=17.50 sft1x7’-0”x3’-0”=21 sft |
| 58 | Providing and fixing of 3.5mm glass panes including beading complete2x1’x6’x5’=60.00 sft |
| 59 | Providing and applying of cement sand plaster in 1:4 mixInside 2(20’-0”+18’-6”)10’-0”=770.00 sft2(20’-0”+20’-0”)10’=800.00 sft =1570 sft or 145.91 m² |
| 60 | Providing and applying of 2mm thick wall putty on plastered surfaceQty vide item no. 8 i.e.145.91 m² |
| 61 | Providing and fixing of electrification a) Lighting point |
| 62 | b) Heating point |
| 63 | c) Panel board |
| 64 | Providing and laying of cement concrete flooring in 1:2:4 mix1x20’x20’=400.00 sft or 37.17 m² |
| 65 | Providing and fixing of structure steel work for truss, purlin, rafter post including cutting welding and placing in position including one coat of red oxide. |
| 66 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender